• Title/Summary/Keyword: Standard Schedule data-base

Search Result 6, Processing Time 0.025 seconds

A Review of Studies on Antibiotic Course and Antibiotic Resistance in Nasopharyngeal Pathogens in Primary Care Setting (일차진료 항생제 치료기간과 비인두 항생제 내성률에 대한 연구 고찰)

  • Shin, Hyang Hwa;Lee, Sun Haeng;Yun, Sung Joong;Chang, Gyu Tae
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.32 no.2
    • /
    • pp.64-71
    • /
    • 2018
  • Objectives The purpose of this study is to examine the correlation of antibiotics administration duration and antimicrobial resistance by reviewing domestic and foreign literatures. Methods We searched literatures dated up to 23 February, 2018 in PubMed and Cochrane Library using terms of "Anti-Bacterial Agents", "Carrier State", "Nasopharynx", "Drug Administration Schedule", and also searched via RISS (Research Information Service System), KISS (Koreanstudies Information Service System), DBpia (DataBase Periodical Information Academic) using terms of antibiotics, resistance, and dose. Results In comparison with shortened and standard antibiotic course, longer treatment duration is associated with greater antimicrobial resistance or non-significant difference, but we cannot find literature that shortened antibiotic course increases antimicrobial resistance on human nasopharyngeal flora. Conclusions Currently, there is no evidence that completing the standard antibiotic course reduces antimicrobial resistance. It can be a strategy for reducing antibiotic use to apply Korean medicine treatment, as well as short-course antibiotic therapy or delayed antibiotic prescription. Additional well-designed trials should be conducted in domestic and foreign settings about the appropriate duration of antibiotic therapy.

An Integrated Construction Management System Based on the Earned Value Concept (EV개념에 의한 통합건설공사관리시스템)

  • Chung Chul-Won;Lee Jeom-Su;Oh Kyu-Whan;Chang Jin-Sik;Lee Yu-Seop;Park Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.155-162
    • /
    • 2001
  • Recently, in Korea, a few construction companies have been tried to develop a management system, which is able to integrate schedule and cost. In spite of these attempts, however, advanced management techniques can be hardly applied under the BoQ based management system. In order to improve these problems, many studies have been peformed, but yet could not overcome practical limitations. Besides, the application of historical data is below the level since it is so difficult to accumulate and feed-back historical data under the unique character of construction industry. Consequently, lots of time and effort have being wasted to establish control criteria. The newly generated Information is not systematically managed as well. Therefore, this study suggests Integrated Construction Management System complemented the existing practical problems.

  • PDF

An Analysis of Electricity Consumption Profile based on Measurement Data in High-rise Apartment Complex (실측자료 기반의 공동주택 시간별 전력소비 패턴 분석 연구)

  • Im, Kyung-Up;Yoon, Jong-Ho;Shin, U-Cheul;Park, Jae-Sang;Kim, Kang-Sik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.127-132
    • /
    • 2011
  • Worldwide, the building energy simulation becomes inevitable step for predicting the energy consumption in building. In simulation process, the expertise is required for the accurate analysis results. In Korea, however, most of user use the inconsistent data with Korea circumstance. In this step, we need to construct the standard input data matched building in Korea. In this study, electricity consumption of apartments in Daejeon is analyzed. The yearly data of a apartment complexes of 2009 are analyzed as monthly, daily(week and weekend), timely, and completion year. With this result, we are able to predict the demand pattern of electricity in a house and make the schedule by demand pattern. The results of this study are followed. The averaged amount of electricity consumption in winter is higher than summer because of the high capacity of heating equipment. All of the house has electric base load from 0.26kWh to 0.5kWh. The average of the electricity consumption of month is shown as 326.7kWh. A week is seperated as 4 part such as week, weekend, Saturday and Sunday. During week, the average of timely electricity consumption is shown as 0.442kWh. The Saturday consumption is 0.453kWh. The Sunday is 0.461kWh.

  • PDF

A base technical development and standardization plan of Customer Premises (21C 댁내 정보화 기반조성을 위한 구내통신선로설비 기반기술개발 및 표준화 계획)

  • 최세하
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.4
    • /
    • pp.495-509
    • /
    • 1998
  • Telecommunication network has been constructed and developed to provide voice. data, and simple image communication service in accordance with the demand increase and the various service tendency according to the growth of social economy It is expected that various multimedia services are transmitted and received through a telecommunication media. First of all, for the sake of realization of these schemes in house, it is essential to make the customer premises networks to be higher level. Especially, the demand increment of customer services and the improvement of technology would be expected to be a result of a main-stream strategic industry. This paper briefly describes investigation results concerning technical development and standardization trends of advanced nation, and introduce technical development and standardization plan which the Government is presently carrying out. We also proposes the schedule of technical development and standardization plan related to international standard.

  • PDF

3D game animation production pipeline and application instance proposal (3D게임 애니메이션 제작 파이프라인 및 적용 사례 제안)

  • Han, Dong Hoon;Ryu, Seuc-Ho;Lee, Dong-Lyeor;Che, Te-June;Lee, Hung-Woo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.644-646
    • /
    • 2007
  • On-line game industry had accomplished much growths and development. One in pain of the game enterprises according to quality of on-line comes to be short Game production pipeline and it is suitable in quick production schedule and to be easy to the standard research of form by of 3D game character animations which are various the game production at the time of application is possible, operation by and type by in necessity. Element by model classification of the digital base game character which is used in game it set from the research which it sees and research it analyzed and the fundamental data which is necessary to 3D game character animation productions escape it tried. And the digital motioncapture it applies a cap department system and real picture of the character animation which is various at real-time the control research moving and it advances at the time when the effectiveness is short highly in game industry and digital contents industry application the character animation production process which is possible and production pipeline escape the reporter to do it does.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF