• Title/Summary/Keyword: Standard Manual

검색결과 505건 처리시간 0.024초

COMPARISON OF MONOMER RELEASE FROM PIT AND FISSURE SEALANT FOLLOWING VARIOUS SURFACE TREATMENT (치면열구전색제의 광중합 후 표면 처리 방법에 따른 미반응 모노머 용리 비교)

  • Lee, Sang-Woo;Lee, Ju-Hyun;Seo, Hyun-Woo;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제33권1호
    • /
    • pp.70-76
    • /
    • 2006
  • The aim of this study was comparison of effectiveness of surface treatment methods in reducing the oxygen-inhibited layer of a commercially available freshly polymerized, light cured dental sealant($concise^{TM}$, 3M, St Paul, USA). Surface treatment groups were consisted of no treatment(negative control group) and 3 experimental groups according to surface treatment of light-cured sealant. Experimental group I was 10 seconds' exposure to distilled water syringe, group II was 10 seconds' manual application using a cotton pellet wetted with 75% alcohol and group III was 10 seconds' prophylaxis with pumice/water slurry using rubber cup on a slow-speed handpiece. All specimens were immersed in 5ml distilled water and stored at 37c water bath for 10 minutes. All eluates were analyzed by HLPC for identification and quantitive analysis of monomers. The results of this study can be summarized as follows. 1. None of the chromatograms of the tested sealant displayed peaks with the same retention time as that of the standard solution, except for TEGDMA. 2. All surface treatment group had a statistically significant decrease of monomer release in comparison with no treatment group. 3. Removal effects of unreacted monomer in group III was statistically significant in comparison with group I and group II. These results revealed that mechanical method using pumice and rubber cup is the most effective in removing residual monomer and may be valuable to be used effectively in clinic.

  • PDF

Automatic Left Ventricle Segmentation by Edge Classification and Region Growing on Cardiac MRI (심장 자기공명영상의 에지 분류 및 영역 확장 기법을 통한 자동 좌심실 분할 알고리즘)

  • Lee, Hae-Yeoun
    • The KIPS Transactions:PartB
    • /
    • 제15B권6호
    • /
    • pp.507-516
    • /
    • 2008
  • Cardiac disease is the leading cause of death in the world. Quantification of cardiac function is performed by manually calculating blood volume and ejection fraction in routine clinical practice, but it requires high computational costs. In this study, an automatic left ventricle (LV) segmentation algorithm using short-axis cine cardiac MRI is presented. We compensate coil sensitivity of magnitude images depending on coil location, classify edge information after extracting edges, and segment LV by applying region-growing segmentation. We design a weighting function for intensity signal and calculate a blood volume of LV considering partial voxel effects. Using cardiac cine SSFP of 38 subjects with Cornell University IRB approval, we compared our algorithm to manual contour tracing and MASS software. Without partial volume effects, we achieved segmentation accuracy of $3.3mL{\pm}5.8$ (standard deviation) and $3.2mL{\pm}4.3$ in diastolic and systolic phases, respectively. With partial volume effects, the accuracy was $19.1mL{\pm}8.8$ and $10.3mL{\pm}6.1$ in diastolic and systolic phases, respectively. Also in ejection fraction, the accuracy was $-1.3%{\pm}2.6$ and $-2.1%{\pm}2.4$ without and with partial volume effects, respectively. Results support that the proposed algorithm is exact and useful for clinical practice.

Study of Mechanical Characteristics of Electric Cupping Apparatus in Korea for Suggestion of its Assessment Guideline (국내 평가 가이드 라인 제시를 위한 전동식 부항기의 특성 조사에 관한 연구)

  • Yi, Seung-Ho;Kim, Eun-Jung;Shin, Kyung-Hoon;Nam, Dong-Woo;Kang, Jung-Won;Lee, Seung-Deok;Lee, Hye-Jung;Lee, Jae-Dong;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2010
  • Objectives : The mechanical properties of Korean electric cupping systems are studied via experimental measurements. The study aimed at establishing the fundamentals of industrialization and systemization of oriental medicine device industry, as well as improving the quality of life for many Koreans. Methods : We reviewed the studies on traditional cupping as well as modern one to fine necessary factors for electric cupping systems. To characterize the mechanical properties of Korean electric cupping systems, we measured the pressure characteristics of commercially available electric cupping system by using an automatic pressure acquisition system and a standard cup. The pumping capability was checked at 40 seconds, and the stability of the suction cup was checked at 600 seconds. We also acquired the noise level of each system in clinical setting. To check the portability of each system, we also measured its physical dimensions. We scrutinized system manuals provided by the system manufacturers. Results : It took less than 5 second to reach the pressure if the connection between the air hose and the vacuum valve of the cupping system was secure. Pressure diminished to no more than 10% for 600s for all systems. Noise levels were 55~70 dB. Increase in pressure was too fast to control for a designated vacuum level except for one product. Conclusions : The Pumping ability of the systems is impressive and reliable. Pressure retention ability of each cup is quite reliable and reproducible. Therefore, their mechanical performances were worthy of recommendation. Some of them had noise level higher than 60 dB and they were bothersome. It was also suggested that the control for low to middle pressure needed to be accomplished by the cupping system.

A Study on an acceptance of CDC guideline on practical emergency department planning -Focusing on comparison CDC guideline to Emergency Medical Service Act- (응급실에서의 감염관리 표준지침의 반영에 관한 연구 -응급실에서의 감염관리 표준지침과 응급의료에 관한 법률의 반영 비교를 중심으로-)

  • Yoon, Hyung Jin;Oh, Joon-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제16권11호
    • /
    • pp.7237-7243
    • /
    • 2015
  • Korea Centers for Disease Control and Prevention(CDC) has been provided not only manual of managing infectious patient but also functional requirement of space in emergency department(ED) by distributing "Guideline for infection control in emergency department(GICED)" in 2009. To understand how much the guideline enforces its functional requirement on ED planning practice, it is compared to Emergency Medical Service Act(EMSA) a basic standard for ED planning. As a result, it is clear that those have different focal point in functional program and don't share infection control issue. By reviewing target hospitals' EDs opened around 2009, all ED have satisfied with the EMSA requirement but guideline. Those are selectively adapted infection control related spaces CDC guideline suggested regardless of open year so that target EDs are not to be influenced by the guideline. This research can support as a reference research when the EMSA are going to be reinforced by infection contol issue.

A Case Study on the Management for Mid-to Senior Age Human Resources of Enterprises following the Extension of Retiring Age Law (정년연장 법제화에 대응하는 기업의 장년인력관리 사례연구)

  • Oh, Ji-hyun;Lee, Young-min
    • Journal of Practical Engineering Education
    • /
    • 제6권2호
    • /
    • pp.119-126
    • /
    • 2014
  • The purpose of this study is to take a look at the cases on managing the senior human resources of business enterprises following the significant number of retirement of baby-boom generation and obligatory retirement age of 60 years of age and present the implication points in policies. With respect to the implication of the company, it would urgently require the introduction of programs with long-term point of view for career management strategy from the time of employment to the resignation, settlement of company leave system called chulhyang, expansion of wage peak system, full-time job transfer support center within the enterprise for retirement management, expansion of various consulting, conversion of paradigm on senior human resource management of top management in the enterprise level. In the government level, it is considered as required for systematic supplementation of the chulhyang system, improvement of support system for employment encouragement fund, expansion of national work capability standard-based senior employment field as well as task development, support for innovation of personnel management system, supply of management manual and implementation of job transfer education for life-time conversion period in the government level.

Implementation of Barcelona Basic Model into TOUGH2-MP/FLAC3D (TOUGH2-MP/FLAC3D의 Barcelona Basic Model 해석 모듈 개발)

  • Lee, Changsoo;Lee, Jaewon;Kim, Minseop;Kim, Geon Young
    • Tunnel and Underground Space
    • /
    • 제30권1호
    • /
    • pp.39-62
    • /
    • 2020
  • In this study, Barcelona Basic Model (BBM) was implemented into TOUGH2-MP/FLAC3D for the numerical analysis of coupled thermo-hydro-mechanical (THM) behavior of unsaturated soils and the prediction of long-term behaviors. Similar to the methodology described in a previous study for the implementation of BBM into TOUGH-FLAC, the User Defined Model (UDM) of FLAC based on the Modified Cam Clay Model (MCCM) and the FISH function of FLAC3D were used to extend the existing MCCM module in FLAC3D for the implementation of BBM into TOUGH2-MP/FLAC3D. In the developed BBM module in TOUGH2-MP/FLAC3D, the plastic strains due to change in suction increase (SI) in addition to mean effective stress are calculated. In addition to loading-collapse (LC) yield surface, suction increase (SI) yield surface is changed by hardening rules in the developed BBM module. Several numerical simulations were conducted to verify and validate the implementation of BBM: using an example presented in the FLAC3D manual for the standard MCCM, simulation results using COMSOL, and experimental data presented in SKB Reports. In addition, the developed BBM analysis module was validated by simultaneously performing a series of modeling tests that were performed for the validation of the Quick tools developed for the purpose of effectively deriving BBM parameters, and by comparing the Quick tools and Code_Bright results reported in a previous study.

Water Supply Change Outlook for Geum River Basin Considering RCP Climate Change Scenario (RCP 기후변화 시나리오를 고려한 금강유역의 미래 용수공급 변화전망)

  • No, Sun-Hee;Jung, Kwan Sue;Park, Jin Hyeog;Ryoo, Kyong Sik
    • Journal of Korea Water Resources Association
    • /
    • 제46권5호
    • /
    • pp.505-517
    • /
    • 2013
  • In this study, water supply for Geum River Basin was calculated by regulating the future water supply of Dam with the future expected discharges. HadGEM2-AO, which is the climate change prediction model that KMA (Korea Meteorological Administration) recently introduced was used for this study. The data of weather stations within the Geum River basin was extracted with the new Greenhouse Gas RCP scenario. The runoff of Geum river basin was simulated using the ArcSWAT for the 1988~2010 period. After validating the model, the similarity of results between simulation and observation at the Yongdam Dam and Daecheong Dam was 92.25% and 95.40%, respectively, which shows a good agreement with observed data. As the result of analysis for the discharges, the discharges would increase 47.76% under the RCP4.5 scenario and 36.52% under the RCP8.5 scenario. Water balance analysis was conducted by the KModSim for predicting the water supply under the runoff variation. We analyzed the volume of water intake with national standard of water supply 95% by Dam Operation Manual. By the analysis under RCP4.5 scenario, $9.41m^3/s$, $24.82m^3/s$ of additional water supply is available on Yongdam Dam and Daecheong Dam. By the analysis under the RCP8.5 scenario, $6.48m^3/s$, $21.08m^3/s$ of additional water supply is available on Yongdam Dam and Daecheong Dam.

Monitoring of the mortalities in the aquaculture farms of South Korea (한국 주요 양식종의 수산동물 폐사피해 모니터링)

  • Kim, Jin Woo;Lee, Han Na;Jee, Bo Young;Woo, Sung Ho;Kim, Young Jae;Lee, Mu Kun
    • Journal of fish pathology
    • /
    • 제25권3호
    • /
    • pp.271-277
    • /
    • 2012
  • The practical monitoring was performed to survey the mortalities in aquaculture farms of olive flounder, rockfish, rainbow trout, Japanese eel, white shrimp and abalone in South Korea from May to November, 2011. The aquatic organism disease inspectors, who have the national licenses for the diagnosis and prevention of aquatic disease and have close relationship with the farms, investigated the rates and causes of mortalities according to the standard manual. In 70 flounder farms, the cumulative mortalities rate was 27.9%, and the mortalities were caused by scuticociliatosis, streptococcosis, VHS, non-infectious loss, vibriosis and gliding bacterial disease. The moralities rate of 30 rockfish farms was 13.6%, and those were mainly contributed by gill flukes and streptococcosis. Most of mortalities of rainbow trout were caused by non-infectious loss and protozoan white spot disease. The mortalities rate of Japanese eel was 0.6% by edwardsiellosis, protozoan white spot disease and gill flukes. The loss rate of white shrimp was 71.2%, and most of them was related with non-infectious ones, such as carnivalization, transportation loss, and the rest was caused by viral white spot disease. The mortalities rate in the abalone farms was 10.7% and all of them were related with non-infectious loss.

A CDMA Network-based Wireless System for Measuring Lap Time on a Ski Slope (CDMA 망에 기반한 스키장 슬로프의 무선 구간 기록 측정 시스템)

  • Lee, Hyung-Bong;Park, Lae-Jeong;Moon, Jung-Ho;Chung, Tae-Yun
    • The KIPS Transactions:PartD
    • /
    • 제16D권1호
    • /
    • pp.133-138
    • /
    • 2009
  • This paper introduces a pilot CDMA network-based wireless lap time measurement system set up on a ski slope of Yongpyong Ski Resort. The wireless lap time measurement system is one output of U-Sports Project of Gangwon Province, which is intendended for promoting local strategic business and preparation for hosting 2018 Winter Olympic Games at Pyeongchang. A pair of laser sensors is installed at the entry and exit points of a section requiring lap time measurement on a ski slope. Each laser sensor is connected to a sensor node via wire so that the sensor node can detect the time when a skier enters or exits the section. Also each sensor node is connected to a CDMA network via a modem and receives a standard time from a NTP server. Each node executes the NTP algorithm to synchronize its local time to the received server time. As a result of the time synchronization, the sensor nodes maintain its local time within a resolution of at least 10 miliseconds and transmit the time of detection to a central control center. While the wireless lap time measurement system introduced in the paper does not need expensive measurement equipment, the system allows the central control center to provide lap time records in a more convenient manner compared to conventional manual lap time measuremnt methods.

Adaptation of Isolation Guidelines for Health Care Settings (수용개작방법을 활용한 의료기관의 격리주의지침 개발)

  • Ryu, Jae Geum;Jeong, Jae Sim;Jeong, Ihn Sook;Kim, Jeong Hye;Hong, Eun-Young;Kim, Hyang Sook;Jung, Young Sun;Kwon, Jeong Soon;Lee, Ji Young;Choi, Ji Youn;Kim, Kyung Sug;Kim, Eun Hyun;Cha, Gyeong Suk;Kim, Eun Jin;Park, Kyung Hee;Seo, Hyun Ju
    • Journal of Korean Clinical Nursing Research
    • /
    • 제24권2호
    • /
    • pp.209-226
    • /
    • 2018
  • Purpose: This purpose of this study was to develop evidence-based practice guideline for isolation in health care settings to prevent transmission of infectious diseases utilizing guideline adaption process. Methods: The process of guideline adaptation was performed according to the Korean hospital nurses association's guideline adaptation manual which consisted of three main phases, 9 modules, and 24 steps. Results: The adapted isolation guideline consisted of introduction, overview of isolation guideline, summary of recommendations, recommendations, references, and appendices. The guideline includes 224 recommendations in 4 sections which are organizational administration, standard precautions, transmission-based precautions, and education/counselling. Conclusion: The adapted isolation guideline is recommended to be disseminated and utilized by nurses and clinicians nationwide to improve the isolation practices for infected or colonized patients with communicable diseases and to decrease the transmission of infections in the healthcare settings.