• Title/Summary/Keyword: Standard Manual

Search Result 505, Processing Time 0.033 seconds

Anthropometric Characteristic of Female Student in Model Dpt. (모델 전공 여대생의 인체측정학적 특성)

  • Yoo, Young-June
    • Fashion & Textile Research Journal
    • /
    • v.9 no.4
    • /
    • pp.450-454
    • /
    • 2007
  • The purpose of this study was to offer objective information about standard of selecting and training fashion models by verifying anthropometric characteristics and comparing with general women. Total forty eight fashion models (M=20.08yr ; SD=1.7) were recruited by convenience sampling. Thirty eight items of participants were measured by manual of International Society for the Advancement of Kinanthropometric (ISAK). Mean and standard deviation of 38 items and also factor of somatotype (endomorph, mesomorph, ectomorph) were calculated. In the result, somatotype of fashion model was endomorphic ectomorphy, less muscle and taller height. Conclusionally, this study indicated that there is less mesomorphy rating related to muscle quantity, bone mass in somatoplot. However, it is necessary to provide the program enhancing the physical activity with model department.

Mass measuremeant of soilid density standard using weight exchanger (분동교환기를 이용한 고체밀도기준물의 질량측정)

  • 이용재;장경호;오재윤;정상덕
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1659-1662
    • /
    • 2003
  • The mass measurement of solid density standards using weight exchanger is described. KRISS(Korea Research Institute od Standards and Science) has several solid density standards. Their mass have been measured manually only using a mass comparator(Mettler, 1kg - 0.01mg). However, the uncertaity of the manual mass measurement is up to 300 microgarm much more than 32 microgram of advanced NMIS(National Metrology Institutes) for 1 kg silicon sphere which is primary density standards due to an eccentric error and buoyancy correction error. The new system with a weight exchanger is designed and built to improve the measurement accuracy. It comprises a weight exchager, a mass comparator, air density instruments, and application program for automatic measurement. It is evaluated by measuring several elements in an air tight chamber to verify the performance of it.

  • PDF

-The Development of a Computer Aided System for Robot Work Measurement- (로봇 작업측정을 위한 컴퓨터 지원 시스템의 개발)

  • 권규식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.24 no.62
    • /
    • pp.49-58
    • /
    • 2001
  • In recent years, a number of robot work measurement systems have been developed. This study discusses CARS (Computer Aided Romum System) which is to computerize the existed manual version ROMUM (RObot Modularization of the Unit Motion) method as the predetermined time system for robot work measurement. The ROMUM was developed to establish the standard time of work through modularize the unit motions in robot tasks. The CARS is designed on a menu driven form by computer assist for user interface and then interacts with user effectively. Therefore, the system can provide the convenience of use and minimization of analysis time and degree of judgement for establishing standard time.

  • PDF

A Study for the Message Exchange of the EVSE Communication Controller using XML Schema Transformation

  • Un, Koaunghi;Jang, Hyuksoo;Kim, Myongsoo;Kim, Hwimin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.71-81
    • /
    • 2016
  • An EVSE and the EV exchange XML formatted communication messages with each other, whose structure is described by the V2G CI schema in the ISO/IEC 15118 international standard, and the EVSE and the power grid exchange messages based on SCL file with each other, whose structure is described by SCL schema in the IEC 61850 international standard. Because XML files can be restructured by XSLT, V2G messages can be transformed to/from SCL files using XSLT. In this study, the two schemas are analyzed and compared in order for the restructuring of the two differently structured XML instances. As a result, two XSL scripts can be produced for the transformation between XML files conforming ISO/IEC 15118 V2G CI schema and IEC 61850 SCL schema respectively to avoid manual data mapping which can happen in every application development cases.

Development and Application of Internet Remote Calibration System in the field of DC and LF (직류 저주파 분야 인터넷 원격교정시스템의 개발과 활용)

  • Jung, Jae-Kap;Kim, Kyu-Tae;Park, Seung-Nam;Song, Yang-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2020-2021
    • /
    • 2003
  • Korea Research Institute of Standards and Science (KRISS) has developed a Web-based, remote, Internet calibration system to calibrate the Fluke 5700A/5720A calibrator using a transportable standard: specifically, multifunction transfer standard 4950. Although the uncertainty for the Internet calibration is up to two times larger than that using conventional manual calibration, it has many advantages: no need to transport the customer equipment, a reduction in the calibration service time, a directly enforced traceability to the national standards, convenience, and ease of use for the customers.

  • PDF

The Clinical Study on 2 Cases of Poly neuropathy or Myopathy estimated Patients (다발성 신경병증 및 근병증으로 추정되는 환자의 치료 2례에 대한 증례보고)

  • Lee, Tae-Ho;Hwang, Hee-Sang;Chang, So-Young;Cha, Jung-Ho;Jung, Ki-Hoon;Lee, Eun-Young
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.2 no.1
    • /
    • pp.59-67
    • /
    • 2007
  • Objective : Poly neuropathy is disease that reveals musle relaxation or sensory disorder, and Myopathy is disease that reveals musle weakness, wasting, pain. These diseases occur in the lower or upper limbs. This is the clinical report about Poly neuropathy or Myopathy estimated patients. Method : Patients were treated by acupuncture, herb medicine, bee venom herbal-acupuncture, moxibustion. We evaluated the improvement of symptoms with ROM(Range of Motion) and MCR(Medical Research Council) standard. Result : Symptoms that patients have at admission improved and disappered gradually with oriental medicine therapy. Observing the change of ROM and MCR standard, they indicated us improvement of disease. Conclusion : We achived a desirable result from treatment of peripheral neuropathy or myopathy estimated patients. However, further studies are required to prove the effect of oriental medicine treatment.

  • PDF

Analysis of Technical Error of Manual Measurements (직접 측정한 인체치수의 기술적 오차 분석)

  • Park, Jinhee;Nam, Yun Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.4
    • /
    • pp.641-649
    • /
    • 2016
  • Highly precision body measurements represent basic data required by industry and researches who wish to utilize information about the human body. The proficiency and expertise of the measurers have a significant influence on the error and accuracy of data when various parts from multiple subjects' bodies are measured. Therefore, in order to measure accurate body measurements (when measuring bodies directly), it is necessary to conduct objective analyses on errors. This study calculated the Relative Technical Error of Measurement (%TEM) using data that measured each of 24 subjects and discussed errors and methods to reduce errors by conducting comparison analysis based on measured items and objects. The result of analysis indicated that the errors based on age and gender of the objects of measurement were minor; however, there were comparatively distinct differences in measured errors based on measured items. 'Right and left Shoulder Angle' for all measured subjects displayed the greatest errors and standard deviations. 'Height' dimension, Lateral Malleolus Height and Head Height had big errors; in addition, 'Circumference', Neck Base Circumference and Armscye Circumference also had big errors. More careful measurements of such items with big errors require additional educational plan such as a proposal for more objective and detailed measurement methods. Items with small errors but big standard deviations such as Waist Circumference, Calf Circumference, Minimum Leg Circumference, Chest Circumference, Hip Circumference and Waist Circumference confirmed that errors for them greatly decreased with repeated experiments and resultant measurers increased proficiency; consequently, repeated measuring experiments for these items greatly enhance accuracy.

Suggestion of the Domestic CCTV Inspection Sewer Pipe Defect Codeby Sewer Defect Frequency Analysis (국내 하수관로 결함빈도 분석을 통한 CCTV 조사 결함항목 코드 제안)

  • Son, Jooyoung;Lee, Jaehyun;Kim, Jungryul;Oh, Jeill;Yoon, Sungsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.623-634
    • /
    • 2016
  • Sewer condition assessment involves the determination of defective points and status of aged sewers by a CCTV inspection according to the standard manual. Therefore, it is important to establish a reliable and effective standard manual for identifying the sewer defect. In this study, analytic reviews of the CCTV inspection manuals of the UK, New Zealand, Canada and South Korea were performed in order to compare the defect codes and the protocols of condition assessment. Through this, we also established the standardized method for defect code and revised the calculation method of assigning the condition grade. Analyses of the types and frequencies of sewer defects that obtained by CCTV inspection of 7000 case results, showed that the joint defect and lateral defect were the most frequent defects that occurred in Korea. Some defect codes are found to be modified because those did not occur at all. This study includes a proposed new sewer defect codes based on sewer characteristics.

Automated 3D scoring of fluorescence in situ hybridization (FISH) using a confocal whole slide imaging scanner

  • Ziv Frankenstein;Naohiro Uraoka;Umut Aypar;Ruth Aryeequaye;Mamta Rao;Meera Hameed;Yanming Zhang;Yukako Yagi
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.4.1-4.12
    • /
    • 2021
  • Fluorescence in situ hybridization (FISH) is a technique to visualize specific DNA/RNA sequences within the cell nuclei and provide the presence, location and structural integrity of genes on chromosomes. A confocal Whole Slide Imaging (WSI) scanner technology has superior depth resolution compared to wide-field fluorescence imaging. Confocal WSI has the ability to perform serial optical sections with specimen imaging, which is critical for 3D tissue reconstruction for volumetric spatial analysis. The standard clinical manual scoring for FISH is labor-intensive, time-consuming and subjective. Application of multi-gene FISH analysis alongside 3D imaging, significantly increase the level of complexity required for an accurate 3D analysis. Therefore, the purpose of this study is to establish automated 3D FISH scoring for z-stack images from confocal WSI scanner. The algorithm and the application we developed, SHIMARIS PAFQ, successfully employs 3D calculations for clear individual cell nuclei segmentation, gene signals detection and distribution of break-apart probes signal patterns, including standard break-apart, and variant patterns due to truncation, and deletion, etc. The analysis was accurate and precise when compared with ground truth clinical manual counting and scoring reported in ten lymphoma and solid tumors cases. The algorithm and the application we developed, SHIMARIS PAFQ, is objective and more efficient than the conventional procedure. It enables the automated counting of more nuclei, precisely detecting additional abnormal signal variations in nuclei patterns and analyzes gigabyte multi-layer stacking imaging data of tissue samples from patients. Currently, we are developing a deep learning algorithm for automated tumor area detection to be integrated with SHIMARIS PAFQ.

A Development of Railroad R&D Project Performance Analysis Method (철도사업 성과분석 표준매뉴얼 개발)

  • Jin, Il-Kyoung;Yoo, Jae-Kyun;Byun, Ji-Young
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.472-476
    • /
    • 2011
  • Railway R&D technology development projects for the economic value of technology development does not mention the estimated economic impact on future policies must reflect the issues that are raised. In the research phase of technology development by providing value and economic effects can increase the utilization of technology development are considered. However, some items in some way to analyze and quantify its effect on what the procedures are not standardized, not as needed by individual researchers and analysis by providing a variety of reliability problems can occur. Therefore, the development of technologies to measure the value and economic impact analysis and the development of a standardized manual is needed. In this paper, development of railway technology R & D performance (technical, economic) to be estimated by an objective analysis of standardized and that man should aim to create. And the standard manual of the national economic effect in the development of technologies (production inducement effect, the effect of import substitution industries, including analysis using the taxable year), due to technology development and economic benefits (investment in railways in the handbook and the feasibility of the proposed railway project to produce various ally standards), technology development, and on which to base the valuation will.

  • PDF