• Title/Summary/Keyword: Standard C/T

Search Result 695, Processing Time 0.027 seconds

Joint Shear Behavior Prediction for RC Beam-Column Connections

  • LaFave, James M.;Kim, Jae-Hong
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.1
    • /
    • pp.57-64
    • /
    • 2011
  • An extensive database has been constructed of reinforced concrete (RC) beam-column connection tests subjected to cyclic lateral loading. All cases within the database experienced joint shear failure, either in conjunction with or without yielding of longitudinal beam reinforcement. Using the experimental database, envelope curves of joint shear stress vs. joint shear strain behavior have been created by connecting key points such as cracking, yielding, and peak loading. Various prediction approaches for RC joint shear behavior are discussed using the constructed experimental database. RC joint shear strength and deformation models are first presented using the database in conjunction with a Bayesian parameter estimation method, and then a complete model applicable to the full range of RC joint shear behavior is suggested. An RC joint shear prediction model following a U.S. standard is next summarized and evaluated. Finally, a particular joint shear prediction model using basic joint shear resistance mechanisms is described and for the first time critically assessed.

Adequate Heparin-protamine Neutralization on using Blood Cardioplegic Solution during Extracorporeal Circulation (체외 순환시간의 경과에 따른 Heparin과 Protamine의 적정량에 관한 연구)

  • 변형섭
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.203-210
    • /
    • 1988
  • The clinical experience with the activated clotting time[A.C.T.] for the control of heparin and protamine therapy during cardiopulmonary bypass in 40 patients between April, 1987 and September, 1987 is reviewed retrospectively. All of patients used with cold blood potassium cardioplegia for myocardial protection under standard cardiopulmonary bypass, priming and perfusate techniques respectively. This study was divided into 2 groups of patients followed by cardiopulmonary bypass time. Twenty patients, within 60 minutes of cardiopulmonary bypass time[group A] were compared with twenty patients, from 60 to 120 minutes of cardiopulmonary bypass time[group B]. Using blood cardioplegia for myocardial protection, Author observed wide variation of A.C.T. in individual response to initial heparinization[2mg /kg] and no requirement of additional heparin during cardiopulmonary bypass until 120 minutes. Total heparin amount during cardiopulmonary bypass was not related to body weight and body surface area in the both groups. After cardiopulmonary bypass, amounts of protamine for neutralization of heparin were more required in group B.

  • PDF

ALC(Autoclaved Lightweight Concrete) Hardness Prediction Research By Multiple Regression Analysis (다중회귀분석을 이용한 ALC 경도예측에 관한 연구)

  • Kim, Gwang-Su;Baek, Seung-Hun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.117-137
    • /
    • 2012
  • In the ALC(Autoclaved lightweight concrete) manufacturing process, if the pre-cured semi-cake is removed after proper time is passed, it will be hard to retain the moisture and be easily cracked. Therefore, in this research, we took the research by multiple regression analysis to find relationship between variables for the prediction the hardness that is the control standard of the removal time. We study the relationship between Independent variables such as the V/T(Vibration Time), V/T movement, expansion height, curing time, placing temperature, Rising and C/S ratio and the Dependent variables, the hardness by multiple regression analysis. In this study, first, we calculated regression equation by the regression analysis, then we tried phased regression analysis, best subset regression analysis and residual analysis. At last, we could verify curing time, placing temperature, Rising and C/S ratio influence to the hardness by the estimated regression equation.

  • PDF

Application of AI models for predicting properties of mortars incorporating waste powders under Freeze-Thaw condition

  • Cihan, Mehmet T.;Arala, Ibrahim F.
    • Computers and Concrete
    • /
    • v.29 no.3
    • /
    • pp.187-199
    • /
    • 2022
  • The usability of waste materials as raw materials is necessary for sustainable production. This study investigates the effects of different powder materials used to replace cement (0%, 5% and 10%) and standard sand (0%, 20% and 30%) (basalt, limestone, and dolomite) on the compressive strength (fc), flexural strength (fr), and ultrasonic pulse velocity (UPV) of mortars exposed to freeze-thaw cycles (56, 86, 126, 186 and 226 cycles). Furthermore, the usability of artificial intelligence models is compared, and the prediction accuracy of the outputs is examined according to the inputs (powder type, replacement ratio, and the number of cycles). The results show that the variability of the outputs was significantly high under the freeze-thaw effect in mortars produced with waste powder instead of those produced with cement and with standard sand. The highest prediction accuracy for all outputs was obtained using the adaptive-network-based fuzzy inference system model. The significantly high prediction accuracy was obtained for the UPV, fc, and fr of mortars produced using waste powders instead of standard sand (R2 of UPV, fc and ff is 0.931, 0.759 and 0.825 respectively), when under the freeze-thaw effect. However, for the mortars produced using waste powders instead of cement, the prediction accuracy of UPV was significantly high (R2=0.889) but the prediction accuracy of fc and fr was low (R2fc=0.612 and R2ff=0.334).

Analysis of the Process Capability Index According to the Sample Size of Multi-Measurement (다측정 표본크기에 대한 공정능력지수 분석)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.1
    • /
    • pp.151-157
    • /
    • 2019
  • This study is about the process capability index (PCI). In this study, we introduce several indices including the index $C_{PR}$ and present the characteristics of the $C_{PR}$ as well as its validity. The difference between the other indices and the $C_{PR}$ is the way we use to estimate the standard deviation. Calculating the index, most indices use sample standard deviation while the index $C_{PR}$ uses range R. The sample standard deviation is generally a better estimator than the range R. But in the case of the panel process, the $C_{PR}$ has more consistency than the other indices at the point of non-conforming ratio which is an important term in quality control. The reason why the $C_{PR}$ using the range has better consistency is explained by introducing the concept of 'flatness ratio'. At least one million cells are present in one panel, so we can't inspect all of them. In estimating the PCI, it is necessary to consider the inspection cost together with the consistency. Even though we want smaller sample size at the point of inspection cost, the small sample size makes the PCI unreliable. There is 'trade off' between the inspection cost and the accuracy of the PCI. Therefore, we should obtain as large a sample size as possible under the allowed inspection cost. In order for $C_{PR}$ to be used throughout the industry, it is necessary to analyze the characteristics of the $C_{PR}$. Because the $C_{PR}$ is a kind of index including subgroup concept, the analysis should be done at the point of sample size of the subgroup. We present numerical analysis results of $C_{PR}$ by the data from the random number generating method. In this study, we also show the difference between the $C_{PR}$ using the range and the $C_P$ which is a representative index using the sample standard deviation. Regression analysis was used for the numerical analysis of the sample data. In addition, residual analysis and equal variance analysis was also conducted.

Bioequivalence Assessment of Acephyll® Capsule to Surfolase® Capsule (Acebrophylline HCl 100 mg) by Liquid Chromatography Tandem Mass Spectrometry

  • Nam, Kyung-Don;Seo, Ji-Hyung;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.5
    • /
    • pp.309-315
    • /
    • 2011
  • A sensitive and specific liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the analysis of ambroxol (active moiety of acebrophylline). After acetonitrile precipitation of proteins from plasma samples, ambroxol and the domperidone (internal standard, IS) were eluted on a C18 column. The isocratic mobile phase was consisted of 10 mM ammonium acetate and methanol (10 : 90, v/v), with flow rate at 0.2 mL/min. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z 379.2${\rightarrow}$264.0 and the m/z 426.2${\rightarrow}$175.1 transitions for ambroxol and the IS, respectively. Twenty four healthy Korean male subjects received two capsules (100 mg ${\times}$ 2) of either the test or the reference formulation of acebrophylline HCl in a 2 ${\times}$ 2 crossover study, this was followed by a 1week washout period between either formulation. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were acceptable range of log 0.8 to log 1.25 (e.g., log 0.8964 - log 0.9910 for $AUC_{0-t}$ log 0.8690 - log 1.0750 for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of Korea Food and Drug Administration for bioequivalence indicating that Acephyll$^{(R)}$ capsule (test) is bioequivalent to Surfolase$^{(R)}$ capsule (reference).

Low System Complexity Bit-Parallel Architecture for Computing $AB^2+C$ in a Class of Finite Fields $GF(2^m)$ (시스템 복잡도를 개선한 $GF(2^m)$ 상의 병렬 $AB^2+C$ 연산기 설계)

  • 변기령;김흥수
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.6
    • /
    • pp.24-30
    • /
    • 2003
  • This study focuses on the arithmetical methodology and hardware implementation of low system-complexity A $B^2$+C operator over GF(2$^{m}$ ) using the irreducible AOP of degree m. The proposed parallel-in parallel-out operator is composed of CS, PP, and MS modules, each can be established using the array structure of AND and XOR gates. The proposed multiplier is composed of (m+1)$^2$ 2-input AND gates and (m+1)(m+2) 2-input XOR gates. And the minimum propagation delay is $T_{A}$ +(1+$\ulcorner$lo $g_2$$^{m}$ $\lrcorner$) $T_{x}$ . Comparison result of the related A $B^2$+C operators of GF(2$^{m}$ ) are shown by table, It reveals that our operator involve more lower circuit complexity and shorter propagation delay then the others. Moreover, the interconnections of the out operators is very simple, regular, and therefore well-suited for VLSI implementation.

Dischatge Loads of Nonpoint Source Pollutant in the Upper Watershed of Inigation Reservoir - Case Study of the Goseong Reservoir - (농업용 저수지 상류유역의 비점원오염 유출부하량 산정 - 고성저수지를 대상으로 -)

  • Kim, Jin-Ho;Han, Kuk-Heon;Ryu, Jong-Soo;Jung, Goo-Bok;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.324-331
    • /
    • 2007
  • This study was conducted to evaluate the influence of pollutant loads on the water quality in the Goseong reservoir from May 2005 to October 2006. Annual total runoff at the Goseong-cheon watershed was 968.0 mm in 2005, 382.6 mm in 2006, respectively. The mean concentration of BOD, COD and SS in the stream were 2.28, 6.03, 46.97 mg/L in rainy seasons and 0.95, 2.14, 6.05 mg/L in dry seasons at SWT C sub-watershed. Total-N concentrations ranged from 2.60 to 3.18 mg/L at SWT C sub-watershed, which was generally higher than the quality standard of agricultural water (1.0 mg/L). Total-P concentrations ranged from 0.044 to 0.130 mg/L at SWT C sub-watershed. Measured pollutant loads in the SWT C sub-watershed were 36.7 kg/day of BOD, 72.3 kg/day of T-N and 2.3 kg/day of T-P in 2005 at SWT C sub-watershed, 63.9 kg/day of BOD, 82.8 kg/day of T-N and 1.1 kg/day of T-P in 2006 at SWT C sub-watershed, respectively. In the analysis of the effluent characteristics for NPS pollutants, it appeared that the loading rates of effluent from SWT C watershed were, respectively, BOD 62.3%, T-N 69.6%, T-P 71.1%, SS 70.1% during the rainy season in 2006. The calculated T-N daily pollutant loadings by the unit loading factor method from each sub-watershed were much greater than observed, but the calculated T-P daily pollutant loadings much lesser than observed.

The Study of Hierarchical Transmission Method for Additional Service of Advanced T-DMB (차세대 T-DMB 방송의 부가서비스 제공을 위한 계층적 전송방식에 대한 연구)

  • Kim, Min-Hyuk;Park, Tae-Doo;Kim, Nam-Soo;Jung, Ji-Won;Lee, Seong-Ro;Choi, Myeong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12C
    • /
    • pp.997-1005
    • /
    • 2008
  • In this paper, we proposed advanced T-DMB system which is based on Eureka-147 using UEP coding methods and hiererchical modulation for providing additional services while maintaining BER performance. We simulated the proposed advanced T-DMB system using unequal l6QAM modulation scheme combined with various bit split methods and coding methods such as double binary turbo code of DVB-RCS standard and LDPC code of DVB-S2 standard. In the simulation results, double binary turbo code and LDPC code of proposed advanced T-DMB system have coding gain of 2dB and 3.5dB compared to conventional T-DMB system respectively.

DVB-S2-based T4 class common data link performance improvement plan for UAV system application (무인기 체계 적용을 위한 DVB-S2 기반 T4급 공용데이터링크 성능 개선방안)

  • Bae, Jongtae;Baek, Seongho;Oh, Jimyung;Lee, Sangpill;Song, Choongho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.12
    • /
    • pp.1846-1854
    • /
    • 2022
  • The sophistication and diversification of mission equipment for surveillance and reconnaissance is leading to a demand for large-capacity public data links. Overseas, a T4 class(274Mbps) common data link was applied to the Global hwak, a high-altitude unmanned aerial vehicle, and various research and development are being conducted in Korea. In this paper, we propose a structure in which pilot is additionally applied to improve SNR performance while minimizing data transmission rate loss in the DVB-S2 frame structure, which is a european satellite broadcasting standard, for high-capacity transmission of T4 class or higher in the common data link. For the performance evaluation of the proposed structure, the performance of the DVB-S2 was compared and analyzed by simulating the UAV data link channel environment. As a result of simulation, 0.15% of transmission rate loss occurred at T4 class transmission rate compared to DVB-S2 in the proposed structure, but improved SNR reception performance of 0.2~0.3dB was confirmed in the UAV channel environment.