• Title/Summary/Keyword: Standard Atmosphere

Search Result 286, Processing Time 0.022 seconds

The stress positioning control method for slim CRTs glass design using FEM

  • Hwang, Yoing-Ik;Lee, Tae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.1053-1057
    • /
    • 2007
  • One of the important roles of glass is safety guarantee in CRTs. It is working under high vacuum and has to be maintained continuously for the atmosphere pressure, humidity, and excitation etc,. This paper propose to CRTs glass design method via the stress positioning control for slim CRTs using FEM to ensure the national safety standard and newly demanded safety standard by CRTs set makers.

  • PDF

국내 방폭전기 안전 기준 제정 배경 및 방폭지역 구분 요령

  • Jeong, Jae-Jong
    • Fire Protection Technology
    • /
    • s.15
    • /
    • pp.22-27
    • /
    • 1993
  • The classification of hazardous area is a method of analysing and classifying the environment where explosive gas or vapour atmosphere may be expected to be present. The object of area classification is to enable the proper selection and installation of electical apparatus and other equipments. This report is intended to serve a general reference about the classification procedure of hazardous area with explanations of related Korean Standard.

  • PDF

Variation of Tracer Distribution During the Antarctic Polar Vortex Breakup Shown in ILAS and ILAS-II Data (ILAS와 ILAS-II 자료에서 나타난 남극 와동 붕괴기간의 미량기체 분포변화)

  • Choi, Wookap;Lim, Kyungsoo
    • Atmosphere
    • /
    • v.20 no.3
    • /
    • pp.367-377
    • /
    • 2010
  • Variation of tracer distribution during the vortex-breakup period in the Antarctic region was observed by the data from the Improved Limb Atmospheric Spectrometer (ILAS) and ILAS-II. All four trace species including methane, nitrous oxide, ozone, and water vapor show similar patterns of vertical gradient in spite of different structures of zonal mean mixing ratio. Timings of vortex breakup on each level are estimated by two different methods, and they are compared with zonal standard deviations following the latitude circle of each trace species. Although the tracers have different chemical life times and sink/source, the zonal standard deviation patterns show remarkable similarities. The zonal standard deviation shown here to measure the zonal asymmetry of tracer distribution is believed to diagnose the timing of the Antarctic polar-vortex breakup reasonably well.

A Study on the Standard Durable Years of Pipe Framed Greenhouses (파이프 골조 온실 구조물의 표준내용연수 연구)

  • 남상운
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.1
    • /
    • pp.96-101
    • /
    • 2001
  • In designing the greenhouse structures, snow and wind loads must be estimated on the basis of the probability of occurrence of snow or wind storms of a given intensity. The recurrence interval chosen depends on the standard durable years and safety factors of the greenhouse. This study was carried out to find the standard durable years of pipe framed greenhouses. Bend test for metallic materials was conducted on samples of galvanized steel pipes being used in greenhouse frames. A secular change of collapse loads and flexural rigidity for galvanized steel pipes were analyzed with the parts buried in the ground and exposed in the atmosphere. From those experimental results and corrosion rate of galvanized film, the standard durable years for pipe framed greenhouses are estimated as follows ; the small scale pipe houses of movable type is 7∼8 years and the large scale pipe houses of fixed type is 14∼15 years.

  • PDF

Basic Study on Quality Assurance of Concrete Structure by using Odor Sensor (후각센서 사용에 의한 콘크리트 구조물의 품질평가에 관한 기초적 연구)

  • Shirokado, Yoshitsugu;Kagaya, Makoto;Lee, Sang-Hun
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.42-42
    • /
    • 2010
  • In order to assure the quality of concrete structure in construction process, the odor strength measured by using odor sensor was used to evaluate curing effect. Then, the compressive strength and odor strength in ordinary concrete N were shown in water curing(=standard curing), indoor and outdoor atmospheric curing condition. The difference between odor strength in the standard curing and that in each curing condition was defined as the difference in the odor strength. And the difference in odor strength in slag powder concrete BP cured in water curing(=standard curing) for different period before exposing in outdoor atmosphere in winter season were evaluated at the age of 14 days. A necessity to prolong the moisture curing for the slag powder concrete BP compared with the ordinary concrete N to obtain a required curing effect was shown by measuring the odor strength and long term compressive strength.

  • PDF

Comparative Experiment to Determine the Activation Factor of Lead dioxide by Kinds in Measuring the Concentration of Sulfur oxides in the Atmosphere by $PbO_2$ Cylinder Method (사용시약별로 본 이산화연법에 의한 대기중 황산화물의 비교측정및 자동측정 성적과의 비교)

  • 최덕일
    • Journal of Environmental Health Sciences
    • /
    • v.2 no.1
    • /
    • pp.29-31
    • /
    • 1975
  • This experiment Was carried out under two points of view, from May 1st to the end of 1973. One was the comparative determination of the activation factor of Lead dioxide by kinds in measuring of Sulfur oxides concentration by $PbO_2$ cylinder method, and the other was the comparison that result with the record of auto analyzer. Five measuring sites were selected out of Seoul City. Three kinds of Lead dioxide made in Japan (B,C and D) were compared with Standard $PbO_2$ (A for use in Determination of Sulphur in the atmosphere, purity 99% up) made in British Institution, and monthly measuring was conducted at every sampling site. The recording by auto analyzer (Beckman Model 906-A $SO_2$ Analyzer) was conducted once or twice a month for 24 hours at each sampling site during the same period. And some significant results were obtained. 1. In comparative experiments to determine the activation degree of three kinds of Lead dioxide (B,C and D), the obtained correction factor of B reagent was 1.09, 1.16 in C and 1.30 in D against Standard $PbO_2$ (A). Therefore, it should be in need of standardization or clear statement about the reagents for use, in determination sulfur oxides by $PbO_2$ cylinder method. 2. Generally, the concentration of Sulfur dioxide by wilkins' convertion method from $SO_3$ showed about 20-30% higher than those by Auto analyzer.

  • PDF

Moist Air Density Calculation for Air Condition (공기 상태량에 대한 습공기 밀도 계산)

  • Kim, Jong-Woo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.2
    • /
    • pp.105-111
    • /
    • 2014
  • Generally the lower part of the Earth's atmosphere, which is 20km above the ground, is called "air." The composition of this area is almost consistent consisting of nitrogen, oxygen, and other gases. Air density refers to the mass per unit volume of earth atmosphere. Though air is made of the mixed gases in a constant composition, the water vapor is one of the very changeable components. The density of moist air is lower than the dry one at the same temperature and pressure. As the density varies according to the pressure and temperature, this paper attempts to explore the main factors in the air quantity calculation by examining first the density calculation process according to the air property, and second the relation between the actual and standard air flow.

Influence of Diverse Atmospheric Conditions on Optical Properties of a Pulse Laser in a Time-of-Flight Laser Range Finder

  • Shim, Young Bo;Kwon, Oh-Jang;Choi, Hyun-Yong;Han, Young-Geun
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • We investigate the propagation characteristics of a pulse laser in a time-of-flight laser range finder (TOF-LRF) system with variations in atmospheric conditions, such as temperature, pressure, relative humidity, and the concentration of $CO_2$. The measurement error of distance related with the group velocity change in the TOF-LRF system is analyzed by considering the refractive index of the standard atmosphere with variations in atmospheric conditions. The dependence of the pulse width broadening induced by chromatic dispersion of the standard atmosphere on the operating wavelength and the initial pulse width of the light sources is discussed. The transmission of air with variations in the relative humidity or the concentration of $CO_2$ is analyzed by using different values of absorption coefficients depending on the operation wavelength of the light source in the TOF-LRF system.

Extraction of the atmospheric path radiance in relation to retrieval of ocean color information from the TM and SeaWiFS imageries

  • Ahn, Yu-Hwan;Shanmugam, P.
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.241-246
    • /
    • 2004
  • The ocean signal that reaches the detector of an imaging system after multiple interactions with the atmospheric molecules and aerosols was retrieved from the total signal recorded at the top of the atmosphere (TOA). A simple method referred to as 'Path Extraction' applied to the Landsat-TM ocean imagery of turbid coastal water was compared with the conventional dark-pixel subtraction technique. The shape of the path-extracted water-leaving radiance spectrum resembled the radiance spectrum measured in-situ. The path-extraction was also extended to the SeaWiFS ocean color imagery and compared with the standard SeaWiFS atmospheric correction algorithm, which relays on the assumption of zero water leaving radiance at the two NIR wavebands (765 and 865nm). The path-extracted water-leaving radiance was good agreement with the measured radiance spectrum. In contrast, the standard SeaWiFS atmospheric correction algorithm led to essential underestimation of the water-leaving radiance in the blue-green part of the spectrum. The reason is that the assumption of zero water-leaving radiance at 755 and 865nm fails due to backscattering by suspended mineral particles. Therefore, the near infrared channels 765 and 865nm used fur deriving the aerosol information are no longer valid for turbid coastal waters. The path-extraction is identified as a simple and efficient method of extracting the path radiance largely introduced due to light interaction through the complex atmosphere carried several aerosol and gaseous components and at the air-sea interface.interface.

  • PDF

Estimation of Particle Mass Concentration from Lidar Measurement (라이다 관측자료를 이용한 미세먼지 농도 산정)

  • Kim, Man-Hae;Yeo, Huidong;Sugimoto, Nobuo;Lim, Han-Cheol;Lee, Chul-Kyu;Heo, Bok-Haeng;Yu, Yung-Suk;Sohn, Byung-Ju;Yoon, Soon-Chang;Kim, Sang-Woo
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.169-177
    • /
    • 2015
  • Vertical distribution of particle mass concentrations was estimated from 8-year elastic-backscatter lidar and sky radiometer data, and from ground-level PM10 concentrations measured in Seoul. Lidar ratio and mass extinction efficiency were determined from aerosol optical depth (AOD) and ground-level PM10 concentrations, which were used as constraints to estimate particle mass concentration. The mean lidar ratio (with standard deviation) and mass extinction efficiency for the entire 8-year study period were $60.44{\pm}23.17$ sr and $3.69{\pm}3.00m^2g^{-1}$, respectively. The lidar ratio did not vary significantly with the ${\AA}ngstr{\ddot{o}}m$ exponent (less than ${\pm}10%$); however, the mass extinction efficiency decreases to $1.82{\pm}1.67m^2g^{-1}$ (51% less than the mean value) when the ${\AA}ngstr{\ddot{o}}m$ exponent is less than 0.5. This result implies that the particle mass concentration from lidar measurements can be underestimated for dust events. Seasonal variation of the particle mass concentration estimated from lidar measurements for the boundary layer, was quite different from ground-level PM10 measurements. This can be attributable to an inhomogeneous vertical distribution of aerosol in the boundary layer.