• Title/Summary/Keyword: Standard Apartment House

Search Result 105, Processing Time 0.027 seconds

A Study on the Calculation of Thermal Consumption Unit of Apartment (공동주택의 열사용량원단위 산정에 관한 연구)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.388-393
    • /
    • 2014
  • Energy consumption unit in a building is classified according to uses of electricity, gas, and oil, and it has been studied steadily as a material for establishing policy standards for energy saving in buildings. Meanwhile, consumption unit in apartment house can be calculated differently according to its survey method and area standard. Therefore, with the necessity of reestablishing energy consumption unit, this study has researched thermal energy consumption, Supply dwelling area Exclusive dwelling area, completion year and housing type of 23,791 households of 31 complex in Daejeon. As a result, (1) there was about 20% difference between supply and exclusive dwelling areas. (2) On the basis of exclusive dwelling area, thermal energy consumption unit was calculated as $104.9kWh/m^2{\cdot}a$ in 2010, $104.6kWh/m^2{\cdot}a$ in 2011, and $107.7kWh/m^2{\cdot}a$ in 2012.

A numerical Study for Improvement of Indoor Air Quality of Apartment House (공동주택 단지의 실내 공기질 향상을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Hong, Ji-Eun;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.521-530
    • /
    • 2009
  • This study has been made to execute a research in order to lead the improvement of indoor air quality, examining the indoor ventilation characteristics by using a numerical analysis method. To this end an extensive parametric investigation are made according to various external flow variables such as main wind direction and wind speed by season, building layout design, and location of ventilators, etc. in Daedeok Techno Valley, one of large-scaled apartment in Daejeon. It is observed there was a significant difference of main wind direction between summer and winter. The main wind direction in summer was a south wind, and on the contrary the direction in winter is northnorthwest, which is similar to the average main wind direction for 10 years. One of the important calculation results is that the change of wind direction causes a significant effect on the apartment ventilation by the change of pressure difference around each complex of apartment. In case of favorable area of ventilation, the indoor ventilation rate can meet 0.7 ACH from the standard value only with natural ventilation. On the contrary, in other area the value was much lower than the standard value. If the calculation result applies to the design of layout apartment or placement of ventilators, it will be greatly helpful to the energy saving because it can be parallel with the natural ventilation to help securing ventilation rate, not much depending on the mechanical ventilation.

A Study on the Performance of Noise Level and Airflow Amount of a Kitchen Hood by the Different Conditions of Airflow Path. (레인지후드 덕트설치 조건에 따른 소음 및 풍량특성 연구)

  • Kim, Il-Ho;Kim, Youn-Jae;Lee, Yong-Jun;Lee, Kyu-Dong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.11-14
    • /
    • 2007
  • Noise level and Airflow amount of a kitchen hood are affected by the conditions of airflow path. Thus this study is expected to be used as a basic reference in designing airflow path of apartment housing throughout analysing changes in noise level and airflow amount from the various conditions of airflow path. Noise level generated by the kitchen hood is estimated in a kitchen and a living room of two constructed apartment houses, and an experiment is conducted in an half anechoic chamber to analyze noise level and airflow amount by the different length, diameter and number of windings of a round shaped soft duct which is connected to the kitchen hood. The measured results in apartment houses show that the noise level in both apartments exceeds the NC standard greatly in living spaces. In apartment A, a regular apartment house, the noise level was $NC-65{\sim}75$, $NC-45{\sim}60$ and NC-70, NC-45 in the kitchen and living room with an operation of kitchen hood in 1 and 3 stages. In apartment B, an apartment complex, the noise level was NC-55 and NC-60 in the kitchen and living room with an operation of kitchen hood in 3 stages. In particular, there was an increase of noise level at 125Hz-band resulted from an amplification of sound, which requires adequate measures in noise reduction. The results measured in Half anechoic chamber show 99% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 100mm to ${\Phi}$ 125mm, 37% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 125mm to ${\Phi}$ 150mm, and 173% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ l00mm to ${\Phi}$ 150mm. The noise level was lower than the level measured in apartment housing about 20 in NC-value and 11.4 in dB(A)-value, which was interpreted as the effect of the load by the pressure condition at the rear end of the duct. Also, an amplification of sound in 125Hz-band influenced NC-value considerably, therefore effective measure is needed.

  • PDF

A Study on Predication model for TVOC Emissions of Finishing material in Apartment House (공동주택 건축내장재의 TVOC 방출량에 관한 예측모델 연구)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.55-62
    • /
    • 2002
  • While cognition about an environment pollution becomes important recently, the intense pollution measures about an indoor air environment is required. In the case of building indoor environment, over 80% of modem people is living in building and these days an interest of building interior materials which becomes a reason for indoor environmental pollution in public house, office, is increasing. An experimental measurement method of this study is as follows. (1) American EPA TO-17, ASTMD5116-97, measurement method in VOCs experiment of Japanese closet industrial association (2) 2.4-DNPH cartridge method in HCHO experiment, based on American EPA TO-11 and measurement method of Japanese closet industrial association (3) standard compound is analyzed by using HPLC after solvent extraction process (4) paint and furniture are selected as measurement objects (5) we also made small chamber to grasp an emission characteristic of HCHO and VOCs and to get an environment-amicable forecast model through it, then we developed the model which can forecast emission rate by chamber experiment.

A Study on the Standardization of the System Kitchen by Utilizing Reference Plane (조립기준면을 활용한 시스템키친의 표준화 연구)

  • Lee, Ga-Kyung;Lim, Seok-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.43-52
    • /
    • 2010
  • It has applied the design method of face to face dimension, an MC (Modular Coordination) design method, at design steps of an apartment house for standardization of architecture. But It has been still using center line size. A construction limit isn't specific on these center line size, and dead space occurs with excessive gaps as size matching isn't performed well between structural sieve and parts. And above all, measurement before construction isn't to expect standardization, and to increase custom-made furniture. We investigate manufacture of a preferential domestic system kitchen and construction state, and we derive from a problem in viewpoints of standardization for this. And we utilized a reference plane, and we present construction document and design plan in order to solve these problems. And we analyze an effect got by application of the assembly basis aspect that we presented, and we can raise efficiency of standardization of housing and construction industry, and we light ultimately up.

A Study on the Interior Space of Apartment Housing applying Resident's Participation Designing Method (거주자참여방식을 적용한 공동주택의 실내공간계획에 관한 연구)

  • 박선희;문경하
    • Korean Institute of Interior Design Journal
    • /
    • no.25
    • /
    • pp.68-76
    • /
    • 2000
  • The application of Residents Participation Designing Method is to provide the resident with a chance of either participating in the planning process of the house or selecting other possible options. The multi-household apartments have so far been grown in quantity by means of mass production and hence have contributed in elevating its supply. However, this manner of supplying has a tendency of ignoring much of the individuals concern regarding space planning And has therefore repeatedly standardized and stereotyped ground planning which only concerns its economic profit and effectiveness. As the standard of living and personal wealth have improved over the years, residents have come to demand a more futuristic model designed to satisfy the individuals personal taste and lifestyle. Therefore, the purpose of this study is to suggest the planning method of multi-household apartments to correspond to resident's specific demand.

  • PDF

Study on the Test Methods and Performance Criterion of High Insulated Door (고기밀.고단열 문의 성능평가 및 기준설정에 관한 연구)

  • Kang, Jae-Sik;Choi, Gyoung-Seok;Kim, Kyoung-Woo;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.618-622
    • /
    • 2009
  • About a Structure is performance insulation include air-tight is fundamental performance for energy-saving. The Apartment house of permission balcony enlarged to increase the requirement of market of high-effective door. Since 2001 years the window and wall of insulation performance stronger frailty than keep up performance insulation that increase influence building energy generated heat loss at door. In study on presentation that high-insulation, air-tight door about experimental method and performance standard.

  • PDF

A study on the Plan Modular Establishment for the Development of Wooden Dwelling Model - Focused on the Post & Beam Structure - (목조주택 모형개발을 위한 평면모듈 설정에 대한 연구 - 기둥-보 방식 구조를 중심으로 -)

  • Kang, Man-Ho;Joo, Seok-Joong;Kim, Jae-Deok
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.141-148
    • /
    • 2007
  • In this research, to develope wooden house model with post & beam structure which is commensurate with domestic environment, we analyzed the size and module of a unit space and space organization of existing habitation, then, based on the result, we tried to suggest general wood house modules. For this, we investigated 98 floor plans for 30 pyeong apartment in Seoul, Gyounggi-do, Gwangju, and Jeolla-do. The results are showed as follows. 1) It has shown that 7 posts distances are available in 2 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, and 4.8 m. 2) It has shown that 8 posts distances are available in 3 bay floor plan type - 3.0 m, 3.3 m, 3.6 m, 3.9 m, 4.2 m, 4.5 m, 4.8 m, and 5.1 m. It was concluded as follows, applying the standard of regulations of horizontal modular coordination design, from $\ulcorner$the standard of modular coordination design in architecture(KSF 1525)$\lrcorner$. 1) The available widths are 3.0 m, 3.3 m, 3.6 m, 4.2 m, and 4.8 m, and the available depths are 3.0 m, 3.3 m, 3.6 m, and 4.2 m. 2) To guarantee a space through post module of a room combination, we can use a module of 3.6 m, 4.2 m, 4.8 m except 3.0 m, 3.3 m among available modules. The module investigated in post & beam structure wooden house is applied in basic 6 floor plans as follows. 1) When organize the room on the basis of tile module of 3.6 m, 4.2 m, it was possible to organize the floor plan. 2) After arranging main room, making practical application of variableness which is advantage of post & beam structure, putting to practical use of extra space that becomes the combination of atypical room such as kitchen, dining room, and bathroom, it was possible to organize the floor plan of the residence. 3) It is possible to organize whole rooms through the plan module from 3.6 m to 4.2 m, that decides the floor plan of a wooden house.

Energy Load according to the Units of Apartment House (공동주택 세대 위치에 따른 에너지 부하량)

  • Kim, Sung-Hoon;Lee, Jun-Gi;Kim, Yong-Tae;Lee, Kyung-Hee
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.78-83
    • /
    • 2015
  • In Korea, multi-housing in one of the most common types of residential space due to its easy management and convenience. In particular, south-facing plate-type(一) multi-housing has attracted a great deal of public interest because it consumes less energy compared with other types of multi-housing, making it advantageous from an energy-saving perspective. Although there have been many studies on the annual energy consumption of multi-housing in relation to building shape and area of window, there have not been sufficient research on the annual energy consumption of multi-housing in relation to individual units of the multi-housing. The purpose of this study is to propose a strategy for reducing energy consumption in plate-type(一) multi-housing, taking the units with the lowest energy consumption as the standard. The result, Standard Models's energy load was as 4000 ~ 5600kWh, and Passive Houses's energy load was less than Stand Models at the 1600kWh.

A study on the Plumbing system noise of closet bowl by water supply pressure (급수압에 따른 대변기 설비소음에 관한 연구)

  • Kim, Hang;Choi, Eun-Suk;Ko, Kwang-Pil;Gl, No-Gab;Lee, Tai-Gang;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.11-16
    • /
    • 2006
  • It appraises that use an indoor noise standard, a NC value which is a noise appraisal, a dB(A) value, a N value in foreign country because it doesn't yet ready an appraisal standard in domestic. Also, It appraises that the supply and drainage noise which could change water supply pressure, $4kg/cm^2,\;3kg/cm^2,\;2kg/cm^2,\;1.5kg/cm^2,\;1kg/cm^2$, bring about a noise and inquires how does noise level indicates according to each instruments. In case of a water supply pressure standard, $3kg/cm^2$, a C-605is $3{\sim}5dB(A)$ lower than another instruments in directly overhead stories. It appears that all of them is similar to level in directly under level except c-407(2)Analyzed the NC value, c-605is the lowest level, NC-50, of a water supply pressure, $4.0kg/cm^2$, c-407 is the highest level, NC-55.(3) In case of N value, which is one of water supply methods in Japan, it is the lowest level, N-55, of a water supply pressure, $4.0kg/cm^2$ same as NC value and C-407is the highest level, N-60.(4) In case of water supply that is likely to noise level, It appears 6dB(A) level gap each instruments, and C-605 is the lowest level, 63.9dB(A).

  • PDF