• Title/Summary/Keyword: Stand-alone PV system

Search Result 75, Processing Time 0.028 seconds

Stand-Alone PV System by Parallel Operation Control of Current-Source Inverter without Battery (전류원 인버터의 병렬운전에 의한 축전지 없는 태양광 시스템의 구성)

  • 박성준;김종달
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.291-297
    • /
    • 2003
  • This paper presents a current-source-inverter based on a buck-boost configuration and its application for residential photovoltaic system. The proposed circuit has five switches. Among them, only one switch acts as chopping, and the other determine the polarity of output; therefore, it can reduce the switching loss. Because the input inductor current is operated on the discontinuous conduction mode, high power factor can be achieved without additional input current controller. So the overall system shows a simple structure. The operational modes are analysed in depth, and then it was verified through the experimental results using a 150 [W] prototype equipped with digital signal processor TMS320F241.

Implementation of a Stand-alone Photovoltaic Pumping System with Maximum Power Point Tracking

  • Zhengming Zhao;Kunlun Chen;Liqiang Yuan
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.635-638
    • /
    • 2001
  • Photovoltaic (PV) pumping systems with maximum power point tracking (MPPT) technique aims at obtaining the highest possible power to the pump under various insolation and temperature, thus overcomes the mismatch between the photovoltaic panel and the pumping load. A simple method of tracking the maximum power points and forcing the system to operate close to these points is presented in this paper. The MC68HC908GP32 micro control unit (MCU) is employed to implement the proposed MPPT controller. Experimental results will also show the performances of the photovoltaic pumping system with the MPPT technique.

  • PDF

Stand-alone PV System without Battery (축전지 없는 태양광 시스템의 구성)

  • Hong, Jeng-Pyo;Park, Sung-Jun;Kwon, Soon-Jae;Kim, Jong-Dal;Sohn, Mu-Heon;Kim, Gyu-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.149-153
    • /
    • 2003
  • This paper presents a current-source-inverter based on a buck-boost configuration and its application for residential photovoltaic system. The proposed circuit has five switches. Among them, only one switch acts as chopping, and the other determine the polarity of output; therefore, it can reduce the switching loss. Because the input inductor current is operated on the discontinuous conduction mode, high power factor can be achieved without additional input current controller. So the overall system shows a simple structure. The operational modes are analysed in depth, and then it was verified through the experimental results using a 150 [W] prototype equipped with digital signal processor TMS320F241.

  • PDF

Economic and Environmental Assessment of a Renewable Stand-Alone Energy Supply System Using Multi-objective Optimization (다목적 최적화 기법을 이용한 신재생에너지 기반 자립 에너지공급 시스템 설계 및 평가)

  • Lee, Dohyun;Han, Seulki;Kim, Jiyong
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.332-340
    • /
    • 2017
  • This study aims to propose a new optimization-based approach for design and analysis of the stand-alone hybrid energy supply system using renewable energy sources (RES). In the energy supply system, we include multiple energy production technologies such as Photovoltaics (PV), Wind turbine, and fossil-fuel-based AC generator along with different types of energy storage and conversion technologies such as battery and inverter. We then select six different regions of Korea to represent various characteristics of different RES potentials and demand profiles. We finally designed and analyzed the optimal RES stand-alone energy supply system in the selected regions using multiobjective optimization (MOOP) technique, which includes two objective functions: the minimum cost and the minimum $CO_2$ emission. In addition, we discussed the feasibility and expecting benefits of the systems by comparing to conventional systems of Korea. As a result, the region of the highest RES potential showed the possibility to remarkably reduce $CO_2$ emissions compared to the conventional system. Besides, the levelized cost of electricity (LCOE) of the RES-based energy system is identified to be slightly higher than conventional energy system: 0.35 and 0.46 $/kWh, respectively. However, the total life-cycle emission of $CO_2$ ($LCE_{CO2}$) can be reduced up to 470 g$CO_2$/kWh from 490 g$CO_2$/kWh of the conventional systems.

A Study on the Development of Charging Controller in Stand-Alone PV Power Generation System (독립형 태양광 발전 시스템 충전제어기 개발에 관한 연구)

  • 곽준호;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.916-921
    • /
    • 2004
  • This paper describes microprocessor-based control of photovoltaic power conditioning system. where the microprocessor is responsible for control of output power in accordance with the generated array DC power. The microprocessor includes the control algorithm of maximum power point tracking and converter control algorithm. In this power, we have designed a MPPT(Maximum Power Point Tracker) algorithm with environment factors and a PWM(Pulse Width Modulation) algorithm for high efficiency. The controller has been tested in the laboratory with the power conditioner and shows excellent performance.

Design and Evaluation of stand alone PV Power system for the residential application (독립형 주택용 태양광 발전시스템의 설계 및 운전평가)

  • Ahn, Kyo-Sang;Seo, Hai-Kyung;Lim, Hee-Chun;Kim, Sin-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.352-354
    • /
    • 2003
  • 본 논문에서는 상용전력 계통이 어떠한 이유에 의하여 전력공급이 중단 되었을 때 최소의 전력공급을 위하여 독립형 시스템과 연계형 시스템을 일체화한 독립 연계형 겸용시스템의 적용 가능성을 도출하기 위하여, 설계.제작 하였다. 독립모드에서 부하는 저항부하를 사용하였으며, 300W, 600W, 900W, 1,200W의 부하시 전력품질을 측정하였으며. 1,200W의 부하시에 전압/전류 외율은 5.23% / 5.41%로 부하에 따라 변화하였으며, 연계형 시스템과 달리 전압 왜율이 부하증가에 따라 증가하는 특성을 보여 주었다.

  • PDF

The Development of Accurate GPS Module Using Discrete-Time $H_{\infty}$ Filter (이산형 $H_{\infty}$ 필터를 이용한 고정밀 GPS 모듈의 개발)

  • Hieu, Nguyen Hoang;Long, Nguyen Phi;Lee, Sang-Hoon;Park, Ok-Deuk;Kim, Hyun-Su;Kim, Han-Sil
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.351-353
    • /
    • 2006
  • In this paper, we present the traditional GPS Position- Velocity (PV) model to apply for both Discrete-Time Kalman Filter and Discrete-Time $H_{\infty}$ Filter. The positioning algorithms of both filters are proposed for a stand-alone low-cost GPS module to increase its accuracy. For disturbance cancellation, the Kalman Filter requires the statistical information about process and measurement noises while the $H_{\infty}$ Filter only requires that these noises are bounded. Experiments show that with the same measurement data, $H_{\infty}$ Filter gives us better positioning results compared with Least-Squared method and Kalman Filter.

  • PDF

A Study of Effective Power Management for Infrafree Variable Message Sign (인프라 독립형 가변안내표지판의 효율적 전력 운영 방안 연구)

  • Lim, Se-Mi;Lee, Ji-Hoon;Park, Jun-Seok;Kim, Byung-Jong;Kim, Won-Kyu;Son, Seung-Neo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.6
    • /
    • pp.53-62
    • /
    • 2011
  • Although the demand of Variable Message Sign(VMS) has become pervasive in fulfilling the ITS policy, there are still several unsolved problematic issues. The most critical ones of them are inequality and inefficiency of providing traffic information. This paper proposes the Infra-free Variable Message Sign in order to provide useful informations such as road condition, weather, and traffic of the area, where constructing the infrastructure of communication and power supply is relatively very hard. First of all, the characteristics of infra-free Variable Message Sign are studied and analyzed in deep because of differences between normal Variable Message Sign and Infra-free Variable Message Sign in the configuration and the operating method due to the nature of the Infra-free Variable Message Sign. Futhermore, for effective power management of operating Infra-free Variable Message Sign with limited power acquired through stand-alone PV system, new battery connection structure and dynamically variable power managements for the differently shown messages on Variable Message Sign are proposed. The proposed structure in this paper can be applied to not only power management for Infra-free Variable Message Sign but also power management for the various applications using parallel connection battery system.

Fuzzy Logic Based Energy Management For Wind Turbine, Photo Voltaic And Diesel Hybrid System

  • Talha, Muhammad;Asghar, Furqan;Kim, Sung Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.351-360
    • /
    • 2016
  • Rapid population growth with high living standards and high electronics use for personal comfort has raised the electricity demand exponentially. To fulfill this elevated demand, conventional energy sources are shifting towards low production cost and long term usable alternative energy sources. Hybrid renewable energy systems (HRES) are becoming popular as stand-alone power systems for providing electricity in remote areas due to advancement in renewable energy technologies and subsequent rise in prices of petroleum products. Wind and solar power are considered feasible replacement to fossil fuels as the prediction of the fuel shortage in the near future, forced all operators involved in energy production to explore this new and clean source of power. Presented paper proposes fuzzy logic based Energy Management System (EMS) for Wind Turbine (WT), Photo Voltaic (PV) and Diesel Generator (DG) hybrid micro-grid configuration. Battery backup system is introduced for worst environmental conditions or high load demands. Dump load along with dump load controller is implemented for over voltage and over speed protection. Fuzzy logic based supervisory control system performs the power flow control between different scenarios such as battery charging, battery backup, dump load activation and DG backup in most intellectual way.

Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level (스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구)

  • Yoon, Jong-Ho;Oh, Myung-Hwan;Kang, Gi-Hwan;Lee, Jae-Bum
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.