• Title/Summary/Keyword: Stance Phase

Search Result 250, Processing Time 0.027 seconds

A Case Report on Gait Pattern Change of Unilateral Knee Pain Patient Treated by Korean Medicine: Focused on Gait Analysis Results. (편측 슬관절 통증을 호소하는 환자의 증상 개선에 따른 보행 척도의 변화 보고: 보행 분석을 중심으로)

  • Chu, Hong-Min;Kim, Kwang-Ho;Lee, Young-Ung;Park, Kyung-Tae;Jang, Jong-Won;Kim, Sun-Kyung;Lim, Hyeon-Seo;Kim, Cheol-Hyun;Lee, Sang-Kwan;Sung, Kang-Keyng
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.15 no.1
    • /
    • pp.147-155
    • /
    • 2020
  • Objectives : The aim of this study was to analyze changes in the gait pattern of a unilateral knee pain patient after treatment with Korean Medicine therapy. Methods : We conducted gait analysis 4 times over 11 days to analyze changes in gait parameters using gait analysis systems. Results : Velocity, cadence, step length, and stride length were all increased. On the collateral side, both stance phase and double support (%) decreased. These results are similar to those of hemiplegic patients with improvement patterns. Conclusions : Gait analysis could be used as a good evaluation tool for tracking improvements in knee pain.

A Study on the Design of the Keel in the Energy Storing Prosthetic Foot Using the Finite Element Analysis and the Taguchi Method (유한요소해석과 다구찌방법을 이용한 에너지 저장형 의족용골의 설계에 관한 연구)

  • Lee, Dong-Hui;Jang, Tae-Seong;Lee, Jeong-Ju;Yun, Yong-San
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.613-624
    • /
    • 2000
  • In this study, new design method of prosthetic foot was suggested which can evaluate the performance of prosthetic foot by implementing amputee's gait simulation using the finite element analysis. The basic shape of ESPF(Energy Storing Prosthetic Foot) was designed which is suitable for the below-knee amputee considering mechanical properties and kinematic properties. And, the performance evaluations were performed using the Taguchi method with orthogonal array L25. As a result, average main effect of factors for the ESPF's performance were calculated and then optimum condition of given shape was selected. Essential particulars for the performance evaluation from the simulation result were the quantity of external work needed in stance phase, the quantity of transferred energy from the ESPF through the knee, and the vertical displacement of knee at toe-off. Reasonable optimum condition was obtained from the using performance index. From this study, it was found that it is necessary for the design of ESPF to consider the geometrical data related to the magnitude of load on elastic material.

Gait Pattern Generation for Lower Extremity Exoskeleton Robot and Verification of Energy Efficiency (하지 착용형 외골격 로봇의 효율적 보행패턴 생성 및 에너지 효율성 검증)

  • Kim, Wan-Soo;Lee, Seung-Hoon;Ryu, Jae-Kwan;Baek, Joo-Hyun;Kim, Dong-Whan;Han, Jung-Soo;Han, Chang-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.3
    • /
    • pp.346-353
    • /
    • 2012
  • The purpose of this study is to verify the energy efficiency of the integrated system combining human and a lower extremity exoskeleton robot when it is applied to the proposed gait pattern. Energy efficient gait pattern of the lower limb was proposed through leg function distribution during stance phase and the dynamic-manipulability ellipsoid (DME). To verify the feasibility and effect of the redefined gait trajectory, simulations and experiments were conducted under the conditions of walking on level ground and ascending and descending from a staircase. Experiments to calculate the metabolic cost of the human body with or without the assistance of the exoskeleton were conducted. The energy consumption of the lower extremity exoskeleton was assessed, with the aim of improving the efficiency of the integrated system.

Characteristics of the Compensation for Gait of the Induced Knee Stiffness in Normal Subjects (정상인 보행에서 무릎관절의 유도된 강직에 따른 신체 보상 특성)

  • Woo, Byung-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.357-367
    • /
    • 2013
  • The purposes of this study were investigated physical compensation for gait on induced knee stiffness in normal subjects. Ten subjects were participated in the experiment(age: $26.0{\pm}6.3$ yrs, height: $175.5{\pm}5.3$ cm, weight: $69.1{\pm}6.1$ kg). The study method adopted 3D analysis with five cameras and ground reaction force with two force-plate. Induced knee stiffness level were classified as gait pattern on ROM of knee(free level, $30^{\circ}$ restriction level, fix level). The results were as follows; In angular displacement of hip joint, left hip joint was the more extended in mid-stance on induced right knee stiffness. In angular displacement of knee joint, there was no physical compensation on induced right knee stiffness, but free knee level gait was more flexed in swing phase of right knee joint. In angular displacement of ankle joint, right ankle joint was the more dorsiflexed on induced right knee stiffness, and $30^{\circ}$ restriction level and fix level gait were less plantarflexed in TO2. In trunk tilt, free and $30^{\circ}$ restriction level gait was more backward tilt on induced right knee stiffness. In ROM of each joint, right knee joint was more larger and trunk tilt was more lower on induced right knee stiffness. In GRF, Fx was more bigger lateral force in free and $30^{\circ}$ restriction level gait, and was more bigger medial force in fix level gait. Fy was more bigger propulsion force in free level gait, and was was more bigger braking force in $30^{\circ}$ restriction level gait. Left braking force in $30^{\circ}$ restriction level gait was more bigger. Fz was no significant.

Validation on the Application of Bluetooth-based Inertial Measurement Unit for Wireless Gait Analysis (무선 보행 분석을 위한 블루투스 기반 관성 측정 장치의 활용 타당성 분석)

  • Hwang, Soree;Sung, Joohwan;Park, Heesu;Han, Sungmin;Yoon, Inchan
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.3
    • /
    • pp.121-127
    • /
    • 2020
  • The purpose of this paper is to review the validation on the application of low frequency IMU(Inertial Measurement Unit) sensors by replacing high frequency motion analysis systems. Using an infrared-based 3D motion analysis system and IMU sensors (22 Hz) simultaneously, the gait cycle and knee flexion angle were measured. And the accuracy of each gait parameter was compared according to the statistical analysis method. The Bland-Altman plot analysis method was used to verify whether proper accuracy can be obtained when extracting gait parameters with low frequency sensors. As a result of the study, the use of the new gait assessment system was able to identify adequate accuracy in the measurement of cadence and stance phase. In addition, if the number of gait cycles is increased and the results of body anthropometric measurements are reflected in the gait analysis algorithm, is expected to improve accuracy in step length, walking speed, and range of motion measurements. The suggested gait assessment system is expected to make gait analysis more convenient. Furthermore, it will provide patients more accurate assessment and customized rehabilitation program through the quantitative data driven results.

A Study of Motor Expertise about Kinematic and Kinetic Characteristics of Lower Extremity in the Seokmun Ilwol Martial Art Yin-yang Bo Gait Pattern (석문일월무예 음양보법의 숙련성에 따른 보행 패턴의 하지 운동학 및 운동역학적 특성)

  • Park, Bok-Hee;Kim, Ky-Hyoung
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.239-248
    • /
    • 2014
  • The purpose of this study was to quantify kinematic and kinetic characteristics of Yin-yang Bo gait according to their motor expertise, one of the Seokmun Ilwol martial art gait patterns. Yin-yang Bo gait pattern shows initial forefoot contact instead of heel contact, and increased time of stance phase time, internal-external rotation of ankle-knee-hip joints and pelvic. It aims to produce and store the more energy through continuous homeostasis of center of gravity (COG) and performance of stretch-shortening cycle. Some of these characteristics also were similar to the gait modification strategies for reducing knee adduction moment such as toe-out progression, medial thrust, internal rotation of hip joint. To identify the characteristics, four factors of expert Yin-yang Bo gait performance group were compared to that of none expert group; 1) angles of COG displacement and rotation 2) distal joint pre-rotation in internal-external rotation of ankle-knee-hip joints and pelvic, 3) invariability pelvic potential and pelvic segment total energy 4) knee abduction moment. Six healthy(three male) subjects participated in the experiment to perform Yin-yang gait pattern. Three-dimensional and force plate data were collected. Kinematic and kinetic data were compared between two groups using t-tests. Results showed that 1) the peak point of COG internal rotation angle was reduced in expert group, 2) kneeexternal and hip joint -internal and pelvic rotation angle peak frames were more near points in expert group.

Effects of Hoehn-Yahr Scale on the Activation of Lower-Extremity Muscles during Walking with Parkinson's Patients (파킨슨 환자들의 질병등급척도가 보행 시 하지의 근육활동에 미치는 영향)

  • Kim, Chang-Hwan;Kim, Mi-Young;Moon, Je-Heon;Lim, Bee-Oh
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.287-293
    • /
    • 2014
  • The purpose of this study was to investigate the effects of Hoehn-Yahr scale on the activation of lower-extremity muscles during walking. Electromyography (EMG) analysis was carried out on 36 patients with Parkinson's disease in the off phase of the medication cycle. We recorded EMG signals of the tibialis anterior (TA), medial gastrocnemius (MG), lateral gastrocnemius (LG), soleus (SOL), rectus femoris (RF), vastus lateralis (VL), semitendinosus (ST) and biceps femoris (BF) using Noraxon 16 channels EMG system during walking at preferred speed. Rectified EMG signals were normalized to reference voluntary contractions (RVC) over a gait cycle at the preferred speed, allowing for an assessment of how the activity was distributed over the gait cycle. Compared to the H & Y Scale 1, H & Y Scale 3 exhibited greater activation of the vastus lateralis during mid-stance and greater activation of the medial gastrocnemius during terminal swing. Compared to the H & Y Scale 1, H & Y Scale 2 and 3 exhibited less activation of the tibialis anterior during initial swing. We conclude that the more Hoen & Yahr Scale increase, the more abnormal lower-extremity muscles activation.

Relationship between Dimensionless Leg Stiffness and Kinetic Variables during Gait Performance, and its Modulation with Body Weight

  • Hyun, Seung Hyun;Ryew, Che Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.3
    • /
    • pp.249-255
    • /
    • 2016
  • Objective: This purpose of this study was to analyze the relationship between dimensionless leg stiffness and kinetic variables during gait performance, and its modulation with body weight. Method: The study sample consisted of 10 young women divided into 2 groups (Control, n=5 and Obese, n=5). Four camcorders (HDR-HC7/HDV 1080i, Sony Corp, Japan) and one force plate (AMTI., USA) were used to analyze the vertical ground reaction force (GRF) variables, center of pressure (COP), low limb joint angle, position of pelvis center and leg lengths during the stance phase of the gait cycle. Results: Our results revealed that the center of mass (COM) displacement velocity along the y-axis was significantly higher in the obese group than that in control subjects. Displacement in the position of the center of the pelvis center (Z-axis) was also significantly higher in the obese group than that in control subjects. In addition, the peak vertical force (PVF) and dimensionless leg stiffness were also significantly higher in the obese group. However, when normalized to the body weight, the PVF did not show a significant between-group difference. When normalized to the leg length, the PVF and stiffness were both lower in the obese group than in control subjects. Conclusion: In the context of performance, we concluded that increased dimensionless leg stiffness during the gait cycle is associated with increased velocity of COM, PVF, and the change in leg lengths (%).

The Effect of Arm Swing on Gait in Healthy Adults (팔 흔들기가 정상인의 보행에 미치는 영향)

  • Jung, Hwa-Su;Choi, Su-Hee;Park, Sun-Ja;Oh, Hye-Jin;Cho, Hwa-Young
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.451-459
    • /
    • 2014
  • This study was to performed to get the reference data of the kinetic parameters for normal subjects according to the arm swing type. Forty-five normal subjects($22.62{\pm}2.69years$) pariticpated in this study and preformed 4 sequence according to the arm swing type as follows; first procedure-normal arm swing, second procedure-one arm swing, thrid procedure-no arm swing, fourth procedure-fitness arm swing. There were significant differences according to the arm swing type in the kinetic parameters such as walking speed, hip power, ground reaction force of vertical in terminal stance phase(p<.05). These finding can be utilized (a) as a reference for kinetic data of gait analysis in normal subjects, and (b) as an aide in evaluating and treating patients who have problems relating to gait.

Evaluation of Biomechanical Stability of Newly Developed Revision Total Knee Arthroplasty through Strain and Stress Distribution Analysis within the Tibia: Finite Element Analysis (경골 내 변형률 및 응력 분포 특성 분석을 통한 새로이 개발된 재치환용 인공슬관절의 생체역학적 안정성 평가: 유한요소해석)

  • Han, Paul;Jang, Young-Woong;Yoo, Oui Sik;Kim, Jung Sung;Kim, Han Sung;Lim, Dohyung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.14-23
    • /
    • 2013
  • In this study, biomechanical stability of the newly developed revision total knee arthroplasty (rTKA) was evaluated through strain and stress distribution analysis within the implanted proximal tibia using a three-dimensional finite element (FE) analysis. 2000N of compressive load (about 3 times body weight) was applied to the condyle surface on spacer, sharing by the medial (60%) and lateral (40%) condyles simulating a stance phase before toe-off. The results showed that PVMS within the revision total knee arthroplasty and the proximal tibia were less than yield strength considering safe factor 4.0 (rTKA: less than 10%, Cortical bone: less than 70%, Cancellous bone: less than 70%). The materials composed of them and the strain and stress distributions within the proximal tibia were generally well matched with those of a traditional revision total knee arthoplasty (Scorpio TS revision system, Stryker Corp., Michigan, USA) without the critical damage strain and stress, which may reduce the capacity for bone remodeling, leading to bone degeneration. This study may be useful to design parameter improvement of the revision total knee arthoplasty in biomechanical stability point of view beyond structural stability of revision total knee arthoplasty itself.