• Title/Summary/Keyword: Staircase safety

Search Result 26, Processing Time 0.029 seconds

Evaluating Staircase Safety Using BIM-based Virtual Simulation: Focusing on the Elderly in the Republic of Korea

  • Yang, Hyuncheul;Jeong, Kwangbok;Kim, Sohyun;Lee, Jaewook
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1146-1153
    • /
    • 2022
  • As the population is aging, accidents involving elderly people are also increasing (2014:11,667 persons; 2018: 11,797 persons). In the case of the elderly population, falling accidents are the primary direct or indirect causes of death; in particular, they face an elevated risk of staircase falls. This study proposes a method of evaluating the safety of staircases using Building Information Modeling (BIM)-based virtual simulation. By making a virtual user with the behavioral characteristics of the elderly respond to a staircase in a BIM model, its safety performance can be evaluated. The evaluation criteria were derived from regulations, elements, and characteristics relevant to the safety of staircases. To validate the proposed method, safety evaluation tests were simulated on actual staircases. The evaluation result of the test simulation shows the safety scores of 1.97 points for the elderly user and 2.95 points for the average male adult user against a required safety score of a minimum of 2 points. That is, safety is relative to users as the safety of the same staircase can be different depending upon the different behavioral characteristics of users. The study suggests that the risk of staircase-related fall accidents to the elderly can be reduced by improving staircase designs through the proposed method.

  • PDF

Vestibule Smoke Control Considering the Stack Effect and the Opening of the Outside Door (굴뚝효과와 외부출입문 개방을 고려한 부속실 제연)

  • Yongkwang Kim;Zudal Son;Seoyoung Kim;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.15-24
    • /
    • 2024
  • The purpose of this study is to improve the stack effect of the staircase and the failure to take into account the opening of the outside door of the staircase, which are the disadvantages of the existing smoke control only vestibule. As a result of the study, the new vestibule and the staircase simultaneous smoke control are equipped with an exhaust flap damper with an effective opening area of about 0.25 m2 in the upper part of the staircase, and a ventilator-type air supply fan of about 5 m3/s in the lower part, and take measures to prevent overpressure in the staircase. If you use the new simultaneous smoke control method of the vestibule and staircase, you can achieve the following effects. First, it is possible to open the external entrance door. Second, it can reduce the stack effect. Third, the staircase door closes automatically without fail. And a new method of preventing overpressure was proposed for the vestibule.

A Study on the Design of Optimum Dimension of Staircase -Focused on the Minimum Dimension of Riser, Tread and Slope for Safety on Staircase- (계단의 적정치수 계획에 관한 연구 -계단에서의 안전을 위한 단높이, 단너비, 경사도의 최소치수를 중심으로-)

  • 김용환
    • Journal of the Korean housing association
    • /
    • v.14 no.5
    • /
    • pp.105-116
    • /
    • 2003
  • The purpose of this study is to suggest the method of prevention of staircase accidents, and to make housing environment better through researching the dimension of a housing staircase for Korean. The scope and method of this thesis is to investigate the dimension limits of a staircase (slope, minimum width of tread, maximum height of riser), and to analyze the characteristics of foot condition (jutting rate, foot angle, ball joint, nosing clearance, clearance distance) using the experiment which takes a photograph of foot motion during walking stairs. The results of this thesis are as follows. The slope of a staircase in house is $32.3^{\circ}$$^{\circ}$-$42.1^{\circ}$$^{\circ}$. The riser should be less than 190 mm. The minimum size of tread is 210 mm and proper size is 270 mm.

Evaluation of staircase accidents using 3D virtual simulation based on behavioral characteristics of the elderly (가상공간 시뮬레이션을 활용한 고령자 행동특성 기반 계단 낙상사고 평가)

  • Yang, Hyun-Cheul;Na, Sun-Cheol;Kim, Dong-Hyun;Lee, Jae-Wook
    • Journal of KIBIM
    • /
    • v.7 no.4
    • /
    • pp.21-30
    • /
    • 2017
  • Due to the rapidly aging population, the death rate of elderly people by safety accidents has been increasing. In particular, precautions are needed for falls prevention because they either directly or indirectly cause death. In the case of elderly people, most of the fall accidents occur in dense residential areas, and particularly, the staircase poses a risk of falling. Therefore, a safety assessment should be performed from the design phase. However, in general, staircases are designed using existing stair data or only aims to satisfy the installation criteria. Laws and regulations only define minimum requirements for safety, so it is not possible to prevent fall accidents even if they satisfy the requirements. Therefore, this study proposes a simulation-based method for evaluating the safety of staircases. The behavioral characteristics of the elderly are implemented to an virtual user in a virtual space including staircases, and fall accidents are evaluated by the evaluation logic related to the behavioral characteristics. The result shows that the safety of staircases can be preevaluated and reflected on the design to reduce the possibility of fall accidents of the elderly.

Reliability Analysis in Fatigue Strength of Connecting Rod (커넥팅 로드의 피로강도에 대한 신뢰성 해석)

  • Kim, Cheol-Su;Lee, Jun-Hyeong;Kim, Jeong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1651-1658
    • /
    • 2001
  • It is necessary to evaluate fatigue strength and reliability of the connecting rod which is core part in automotive engine to assure the high level of durability of automobile. For this purpose, the loading conditions in automotive engine is obtained by the dynamic analysis. Based on these results, the critical section was identified by the finite element analysis. The fatigue strength under constant amplitude was evaluated and the mean of the fatigue limit at R = -2.27 derived from the staircase method was 311.2MPa. And the failure probability( F$\sub$p/ ) derived from the strength-stress interference model is 0.0003% at the 99.99% confidence level and the mean factor of safety was 4.2.

The Evaluation of the Village Community Center in Aspects of Universal Design Principles - Focused on 25 Village Community Centers in Hwasoon Province - (농촌 마을회관의 유니버설디자인 적용성 평가 - 전남 화순군 25개 마을회관을 중심으로 -)

  • Moon, In-Young;Kim, Mi-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.1
    • /
    • pp.162-171
    • /
    • 2014
  • This study aimed to evaluate how universal design principles are embodied in the village community center. It will provide preliminary data on constructing a physical space of village community center as small community space in agricultural districts. To achieving the purpose in this study, the research conducted inspection using checklist to 25 village community centers at Hwasoon, Jeonnam province. The conclusion of this study is as follows: Living room and kitchen/dining room by supportive design urgently need installation of Western Style furniture and solutions of stair gap by accessible design, and also the evaluation is unsuited on a fire-gas alarm system and prevention of electric shook system on safety-oriented design. Entrance evaluated in principle for insufficient on safety handle by supportive design and spare chair by adaptable design, and also it unsuited on the solutions of door sill by accessible design and non-skid by safety-oriented design. Bathroom is insufficient lever handle and safety grip by supportive design, sink isn't suitable by adaptable design. Outdoor space information legislation staircase ramp installation and horizontal installation of the staircase was not built.

Inundation Simulation of Underground Space using Critical Dry Depth Scheme (임계 마름 수심기법을 이용한 지하공간 침수 모의)

  • Rhee, Dong Sop;Kim, Hyung-Jun;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.63-69
    • /
    • 2015
  • In this study, a 2D hydrodynamic model equipped with critical dry depth scheme was developed to reproduce the flow over staircase. The channel geometry of hydraulic experiment conducted by Ishigaki et al. was generated in the computational space, and the developed model was validated against flow properties such as discharge, velocity and momentum. In addition, the water surface profile and the velocity distribution evolved in flow over two layers staircases were analyzed. When the initial water depth at the upper floor was 0.3 m, the maximum velocity at lower floor was 4.2 m/s, and the maximum momentum was $1.2m^3/s^2$, and its conversion to force per unit width was 1.2 kN/m. This value was equivalent to the hydrostatic force with 50 cm water depth, and evacuation became difficult, as proposed by Ishigaki et al. For the flow over staircases connecting two layers, the maximum run-up height in flat part connecting two layers was approximately two times higher than the initial water depth in upper floor, and the rapid shock wave with sharp front and long tail was propagated.

Development of PC Double Wall for Staircase Construction (계단실 공사를 위한 PC Double Wall 공법 개발)

  • Suh, Jung-Il;Park, Hong-Gun;Hwang, Hyeon-Jong;Im, Ju-Hyuk;Kim, Yong-Nam
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.571-581
    • /
    • 2014
  • In the present study, hollow precast concrete wall (PC Double Wall) for staircase construction was developed. Comparing the conventional walls, the PC Double Wall can be reduced the lift weight using hollow core and improves the integrity between the PC members. The cross-section and re-bar details of the PC Double Wall were developed considering precast concrete manufacturing, constructability, and the structural safety. Particularly, a form system was developed to manufacture thin and hollow core PC wall efficiently. A mock-up test for a staircase using the PC Double wall was performed to verify the constructability and integrity of the PC walls. The test result verified that joint deformation and cracking did not occur as showing good constructability.

Comparison of Egress Modeling and Experiments for Joint Flow Rate in the Staircase (피난계단 합류 시 유동률에 대한 피난실험 및 모델링 비교)

  • Hwang, Eun-Kyoung;Woo, Sujin;Kim, Jong-Hoon;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.41-46
    • /
    • 2014
  • Junction at the staircase is one of key factors for building egress analysis. The most important factor is the congestion at the door or somewhere connecting from bigger area to smaller one. The other factor is the congestion in the staircase. It happens when people from upper floors meets people from the connecting floor. Especially egress situation at the high-rise building is worse. The simulation of the junction is only described by physical agent algorithms in egress model. For that reason, the description of phenomena will validate with the result of experiment and estimate the gap between modeling and experiment. In this research, the experiment of the junction and the simulation was conducted and validated. The gap between the experiment and the modeling was estimated. The flow rates of modeling were lower than the modeling.

How Visual-Field Obstruction from Fire Smoke Influences a Resident's Necessary Time to Reach Fire Escape and Evacuation Route in a High-rise Apartment Housing (연기발생으로 인한 시야장애가 초고층 공동주택 거주자의 피난계단실 진입시간과 피난경로에 미치는 영향)

  • Seo, Sang-Mok;Choi, Jun-Ho;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.103-110
    • /
    • 2008
  • The purpose of this study is to know how visual-field obstruction from fire smoke influences a resident's necessary time to reach fire escape and evacuation movement in a high-rise apartment housing. Generally, fire smoke not only gives visual-field obstruction and breath troubles to residents but interrupts their evacuation behavior. If a fire smoke layer is formed in the core department when evacuee enters at the evacuation staircase until, residents will be made to undergo a range of vision obstacle. In order to set a situation like that, participants wore eye bandage which had been made especially before the experiment. Also as a comparative standard, through no.1442 Japanese construction ministry notices about the building evacuation safety verification method, this study calculated smoke layer's dissent time and evacuation time. Then to compare with the former, the participants without an eye bandage joined a experiment once again. This study has understood how fire smoke effects on one's evacuation delay by analyzing residents' evacuation time to reach the staircase and movement route, however, in this study a toxic gas is not considered because it might threaten participants not to breathe.