Abstract
In the present study, hollow precast concrete wall (PC Double Wall) for staircase construction was developed. Comparing the conventional walls, the PC Double Wall can be reduced the lift weight using hollow core and improves the integrity between the PC members. The cross-section and re-bar details of the PC Double Wall were developed considering precast concrete manufacturing, constructability, and the structural safety. Particularly, a form system was developed to manufacture thin and hollow core PC wall efficiently. A mock-up test for a staircase using the PC Double wall was performed to verify the constructability and integrity of the PC walls. The test result verified that joint deformation and cracking did not occur as showing good constructability.
Keywords
precast concrete; PC double wall; staircase construction method; mock-up;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Kim OJ, Kim LB. RC Core Sequential Construction Method by Using PC Stairs. Journal of Architectural Institute of Korea. 2005 Mar;49(2):100-8.
2 Yoon YH, Chun YS, Park JY, Jang IH, Kim SB, An HK. System Steel Stairs for RC Structures. Journal of the Korea Concrete Institute. 2003 Sep;15(9):61-6.   과학기술학회마을
3 Rhim HC, Kim OJ, Cho HD, Song JY. Analysis of PC Stairways for Improved Performance Based on Construction Cases. Journal of the Korea Institute of Building Construction. 2008 Jun;24(6):153-62.   과학기술학회마을
4 Lee LH, Yi WH, Lim JH, Lee DN, Woo KS. Behavior of Wall-to-Floor Joint in Bearing Wall System with Double Precast Concrete Panel. Journal of Architectural Institute of Korea. 1997 Jan;13(1):165-72.   과학기술학회마을
5 Lee LH, Yi WH, Lim JH, Lee DN, Woo KS. Behavior of Wall-to-Wall Joint in Bearing Wall System with Double Precast Concrete Panel. Journal of Architectural Institute of Korea. 1997 Feb;13(2):181-86.   과학기술학회마을
6 N.H.Hamid, John B.Mander. A Comparative Seismic Performance Between Precast Hollow Core Walls and Conventional Walls Using Incremental Dynamic Analysis. Arabian Journal for Science and Engineering. 2012 May;37(7):1801-5.   DOI
7 Syspro(R)PART. The Technology behind the Wall. 1st ed. Freilassing: Christian Prilhofer Consulting; 1997. 146 p.
8 Kang SM, Oh JK, Kim OJ, Lee DB, Park HG. Development of a Precast Concrete Structural Wall Adopting Improved Connections in the Plastic Hinge Region. Journal of the Earthquake Engineering Society of Korea. 2010 Apr;14(2):15-26.   과학기술학회마을   DOI
9 Korea Concrete Institute. Concrete Design Code, Korea Concrete Institute. Seoul: Kimoondang Publishing Company; 2012. 600p.
10 Korea Architectural Institute. Korea Architectural Standard Specification. Seoul: Kimoondang Publishing Company; 2013. 1784p.
11 Korea Concrete Institute. Concrete Standard Specification. Seoul: Kimoondang Publishing Company; 2009. 366p.
12 Kang SM, Kim OJ. Domestic and Foreign Present Situation Analysis of a PC Method. DAELIM Technology Research Institute. 2006 Mar; 28-37.