• Title/Summary/Keyword: Staggered

Search Result 500, Processing Time 0.022 seconds

An Analysis on Applicability of Geophysical Exploration Methods to Monitoring Polymer-flooding (물리탐사 기법들의 화학공법 모니터링 적용성 분석)

  • Cheon, Seiwook;Park, Chanho;Ku, Bonjin;Nam, Myung Jin;Son, Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.143-153
    • /
    • 2015
  • Polymer flooding for enhancing hydrocarbon production injects into a reservoir polymer solution that is viscous. It is very important to monitor the behavior pattern of the polymer solution in order to evaluate the effectiveness of polymer flooding. To monitor the distribution of polymer solution and thus fluid substitution within the reservoir, we first construct seismic and resistivity rock physics models (RPMs), which are functions of reservoir parameters such as rocks and type of fluid, fluid saturation. For the seismic and resistivity RPMs, responses of seismic and electromagnetic (EM) tomography are numerically simulated as polymer injection, using two dimensional (2D) staggered-grid finite difference elastic modeling and 2.5D finite element EM modeling algorithms, respectively. In constructing RPM for EM tomography, three different reservoir rocks are considered: clean-sand, dispersed shale-sand, and sand-shale lamination rocks. The polymer solution is assumed to have 2 wt% of polymer as normally generated, while water is freshwater or saltwater. Further, neutron logging is also considered to check its sensitivity to polymer flooding. The techniques discussed in the paper are important in monitoring not only hydrocarbon but also geothermal reservoirs.

Indepth Study of Numerical Heat Transfer and Fluid Flow for Energy Saving of Greenhouse (시설하우스 에너지 절감을 위한 열유동 수치 해석 심층 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Choi, Jun-Ho;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.466-471
    • /
    • 2007
  • The purpose of study is to obtain basic but important information for the operation of the greenhouse facility located in the suburb of town. Special emphasis is given on the aspect of energy saving method, which can be easilyapplicable in a practical sense. For this end numerical calculation has been made systematically in order to increase the energy efficiency by the evaluation of the temperature distribution in greenhouse. Major parameters considered are primarily the overall shape of greenhouse together with the various conditions of baffle installion inside greenhouse. Further, the performance of heating system is also carefully compared each other for a number of typical arrangements of heating duct. The performance of the computer program developed in this study is evaluated by the observation of the famous fluid trapping phenomenon occurred in staggered baffle condition in the enclosure of greenhouse. Based on the this study, a number of useful conclusions can be drawn, that is, the installation of baffles are quite effective in energy saving method with a minor modification of facility. Also, it is found that the change of the heating duct system can contribute significantly to the uniform temperature distribution in greenhouse. Further other findings obtained by numerical calculation were not only physically consistent and meaningful but also useful for the determination of optimum condition of practical operation of greenhouse.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

InAs 및 GaAs 웨이퍼를 이용한 Type-II InSb 나노 구조 형성

  • Lee, Eun-Hye;Song, Jin-Dong;Kim, Su-Yeon;Bae, Min-Hwan;Han, Il-Gi;Jang, Su-Gyeong;Lee, Jeong-Il
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.305-305
    • /
    • 2011
  • Type-II 반도체 나노 구조는 그것의 band alignment 특성으로 인해 광학 소자에 다양한 응용성을 가진다. 특히, 대표적인 Type-II 반도체 나노 구조인 InSb/InAs 양자점의 경우, 약 3~5 ${\mu}m$의 mid-infrared 영역의 spectral range를 가지므로, 장파장을 요하는 소자에 유용하게 적용될 수 있다. 또한, Type-II 반도체 나노 구조의 밴드 구조를 staggered gap 혹은 broken gap 구조로 조절함으로써 infrared 영역 광소자의 전자 구조를 유용하게 바꾸어 적용할 수 있다. 최근, GaSb wafer 위에 InSb/InAsSb 양자점을 이용하여 cutoff wavelength를 6 ${\mu}m$까지 연장한 IR photodetector의 연구도 보고되고 있다. 하지만, GaSb wafer의 경우 그것의 비용 문제로 인해 산업적 적용이 쉽지 않다는 문제가 있다. 이러한 문제를 해결하기 위해 GaAs wafer와 같은 비용 효율이 높은 wafer를 사용한 연구가 필요할 것이다. 본 연구에서는 Molecular Beam Epitaxy(MBE)를 이용하여 undoped InAs wafer 와 semi-insulating GaAs wafer 상에 InSb 양자 구조를 형성한 결과를 보고한다. InSb 양자 구조는 20층 이상의 다층으로 형성되었고, 두 가지 경우 모두 400${\AA}$ spacer를 사용하였다. 단, InAs wafer 위에 형성한 InSb 양자 구조의 경우 InAs spacer를, GaAs wafer 위에 형성한 양자 구조의 경우 InAsSb spacer를 사용하였다. GaAs wafer 위에 양자 구조를 형성한 경우, InSb 물질과의 큰 lattice mismatch 차이 완화 뿐 아니라, type-II 밴드 구조 형성을 위해 1 ${\mu}m$ AlSb 층과 1 ${\mu}m$ InAsSb 층을 GaAs wafer 위에 미리 형성해 주었다. 양자 구조 형성 방법도 두 종류 wafer 상에서 다르게 적용되었다. InAs wafer 상에는 주로 일반적인 S-K 형성 방식이 적용된 것에 반해, GaAs wafer 상에는 migration enhanced 방식에 의해 양자 구조가 형성되었다. 이처럼 각 웨이퍼에 대해 다른 성장 방식이 적용된 이유는 InAsSb matrix와 InSb 물질 간의 lattice mismatch 차이가 6%를 넘지 못하여 InAs matrix에 비해 원하는 양자 구조 형성이 쉽지 않기 때문이다. 두 가지 경우에 대해 AFM과 TEM 측정으로 그 구조적 특성이 관찰되었다. 또한 infrared 영역의 소자 적용 가능성을 보기 위해 광학적 특성 측정이 요구된다.

  • PDF

Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

  • Jeong Seung-Mi;Kang Dong-Wan;Wolf Christoph
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.243-249
    • /
    • 2001
  • Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.

  • PDF

Seismic Amplitude and Frequency Characteristics of Gas hydrate Bearing Geologic Model (가스 하이드레이트 지층 모델의 탄성파 진폭 및 주파수 특성)

  • Shin, Sung-Ryul;Lee, Sang-Cheol;Park, Keun-Pil;Lee, Ho-Young;Yoo, Dong-Geun;Kim, Young-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.116-126
    • /
    • 2008
  • In gas hydrate survey, seismic amplitude and frequency characteristics play a very important role in determining whether gas hydrate exists. According to the variation of source frequency and scatterer size, we study seismic amplitude characteristics using elastic modeling applied at staggered grids. Generally speaking, scattering occurs in proportion to the square of source frequency and the scatterer volume, which has an effect on seismic amplitude. The higher source frequency is, the more scattering occurs in gas hydrate bearing zone. Therefore, BSR is hardly observed in high frequencies. On the other side, amplitude blanking zone and BSR is clearly observed in lower frequencies although the resolution is poor as a whole. Seismic reflections traveling through free-gas layer below gas hydrate bearing zone decay so severely a high frequency component that a low frequency term is dominant. Amplitude anomaly of BSR result from high acoustic impedance contrast due to free-gas, which is a very crucial factor to estimate gas hydrate bearing zone. Seismic frequency analysis is carried out using wavelet transform method that frequency component could be decomposed with time variation. In application of wavelet transform to the seismic physical experiments data, we can observe that reflections traveling through air layer, which corresponds to the free-gas layer, decay a high frequency component.

Numerical Analysis on the Flow in Cannulae having Side Holes (사이드 홀을 가진 케뉼라에 관한 수치해석적 연구)

  • Park Joong Yull;Park Chan Young;Min Byoung Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.489-496
    • /
    • 2004
  • Insertion of cannulae into vessels may disturb the blood flow doing non-physiological load and stress on blood cells such that ADP may increase and result in hemolysis. Authors used the computational method to simulate the 3-dimensional blood flow inside of the cannula using numerical method. We limited the research to within the drainage cannulae with side holes inserted through the human vein. In this paper, 9 different cannulae with side holes categorized by the number of side holes of 4, 12, and 20, and also categorized by the array type of side holes of staggered array, in-line array, and alternative in-line array were studied and compared to the cannula with no side holes by using CFD analysis. We evaluated the flow rate, the wall shear stress, and the shear rate and compared them with one another to estimate the effect of the side holes. The flow rate is not proportional to the number of the side holes. However, larger number of side holes can reduce the mean shear rate. Both the number and the array type of side holes play an important role on the fluid dynamics of the blood flow in cannulae.

Effect on the Flow and Heat Transfer of Endwall by Installation of Cut Pin in Front of Pin-fin Array of Turbine Blade Cooling Passage (가스터빈 블레이드 핀-휜 내부 냉각 유로에 분절핀 설치에 따른 바닥면 유동 및 열전달 특성)

  • Choi, Seok Min;Kim, Su Won;Park, Hee Seung;Kim, Yong Jin;Cho, Hyung Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.5
    • /
    • pp.43-55
    • /
    • 2020
  • The effect of cutted pin in front of pin-fin array was analyzed for increasing the cooling performance of gas turbine blade. The numerical simulations were conducted to figure out the flow and thermal characteristics. The base case which is staggered pin-fin array, cut pin case 1 which has X2/Dp=1.25 cut pin and cut pin case 2 which has X3/Dp=1.75 cut pin were compared. The results showed that cut pin increases the strength of the horseshoe vortex which occurred at the leading edge of pin-fin array. Furthermore, the wake effect is reduced at the trailing edge of pin-fin array. As a result, the heat transfer distribution on the endwall increases. However, the friction factor increases owing to the installation of cut pin, but the thermal performance factor is increased maximum 23.8% in cut pin case 2. Therefore, installation of cut pin will be helpful for increasing the cooling performance of pin-fin array of gas turbine blade.

Full mouth rehabilitation in partially edentulous patient with an unstable mandibular position (불안정한 하악위를 가진 부분 무치악 환자에서 전악 수복 증례)

  • Donghwi Yook;Younghoo Lee;Seoung-Jin Hong;Ahran Pae;Kwantae Noh;Hyeong-Seob Kim;Kung-Rock Kwon;Janghyun Paek
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.308-315
    • /
    • 2023
  • In the case of a patients who have lost the centric stop and have a staggered occlusion of the residual teeth, various movements occur when the denture is loaded. Implant placement is necessary to reinforce the retention, support, and stabilization elements to reduce denture movement. However, in this case, considering the patient's age, aversion to surgery, and bone loss, implants were not placed and restoration was performed with a removable partial denture. In this case, it is important to set the correct mandibular position for restoration because the patient has a habit of chewing with the remaining teeth. In this case, a stable mandibular position was established using a gothic arch tracing, and good results were obtained by restoring with partial dentures, so this is reported.

Acceleration of computation speed for elastic wave simulation using a Graphic Processing Unit (그래픽 프로세서를 이용한 탄성파 수치모사의 계산속도 향상)

  • Nakata, Norimitsu;Tsuji, Takeshi;Matsuoka, Toshifumi
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.98-104
    • /
    • 2011
  • Numerical simulation in exploration geophysics provides important insights into subsurface wave propagation phenomena. Although elastic wave simulations take longer to compute than acoustic simulations, an elastic simulator can construct more realistic wavefields including shear components. Therefore, it is suitable for exploration of the responses of elastic bodies. To overcome the long duration of the calculations, we use a Graphic Processing Unit (GPU) to accelerate the elastic wave simulation. Because a GPU has many processors and a wide memory bandwidth, we can use it in a parallelised computing architecture. The GPU board used in this study is an NVIDIA Tesla C1060, which has 240 processors and a 102 GB/s memory bandwidth. Despite the availability of a parallel computing architecture (CUDA), developed by NVIDIA, we must optimise the usage of the different types of memory on the GPU device, and the sequence of calculations, to obtain a significant speedup of the computation. In this study, we simulate two- (2D) and threedimensional (3D) elastic wave propagation using the Finite-Difference Time-Domain (FDTD) method on GPUs. In the wave propagation simulation, we adopt the staggered-grid method, which is one of the conventional FD schemes, since this method can achieve sufficient accuracy for use in numerical modelling in geophysics. Our simulator optimises the usage of memory on the GPU device to reduce data access times, and uses faster memory as much as possible. This is a key factor in GPU computing. By using one GPU device and optimising its memory usage, we improved the computation time by more than 14 times in the 2D simulation, and over six times in the 3D simulation, compared with one CPU. Furthermore, by using three GPUs, we succeeded in accelerating the 3D simulation 10 times.