• Title/Summary/Keyword: Stage efficiency

Search Result 2,430, Processing Time 0.031 seconds

Electrostatic 2-axis MEMS Stage with a Large Area Platform for Probe-based Storage Devices (대면적 플랫폼을 갖는 Probe-based Storage Device(PSD)용 정전형 2축 MEMS 스테이지)

  • Chung, Il-Jin;Jeon, Jong-Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.9 s.186
    • /
    • pp.179-189
    • /
    • 2006
  • Recently the electrostatic 2-axis MEMS stages have been fabricated f3r the purpose of an application to PSD (Probe-based Storage Device). However, all of the components (platform, comb electrodes, springs, anchors, etc.) in those stages are placed in-plane so that they have low areal efficiencies such as a few percentage, which is undesirable as data storage devices. In this paper, we present a novel structure of an electrostatic 2-axis MEMS stage that is characterized by having a large areal efficiency of about 25%. For obtaining large area efficiency, the actuator part consisting of mainly comb electrodes and springs is placed right below the platform. The structure and operational principle of the MEMS stage are described, followed by a design and analysis, the fabrication and measurement results. Experimental results show that the driving ranges of the fabricated stage along the x and y axis were 27$\mu$m, 38$\mu$m at the supplied voltages of 65V, 70V, respectively and the natural frequencies along x and y axis were 180Hz, 310Hz, respectively. The total size of the stage is about 5.9$\times$6.8mm$^2$ and the platform size is about 2.7$\times$3.6mm$^2$.

An objective assessment of the impact of tendon retraction on sleep efficiency in patients with full-thickness rotator cuff tears: a prospective cohort study

  • Ashley E. MacConnell;William Davis;Rebecca Burr;Andrew Schneider;Lara R Dugas;Cara Joyce;Dane H. Salazar;Nickolas G. Garbis
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.2
    • /
    • pp.169-174
    • /
    • 2023
  • Background: Sleep quality, quantity, and efficiency have all been demonstrated to be adversely affected by rotator cuff pathology. Previous measures of assessing the impact of rotator cuff pathology on sleep have been largely subjective in nature. This study was undertaken to objectively analyze this relationship through the use of activity monitors. Methods: Patients with full-thickness rotator cuff tears at a single institution were prospectively enrolled between 2018 and 2020. Waist-worn accelerometers were provided for the patients to use each night for 14 days. Sleep efficiency was calculated using the ratio of the time spent sleeping to the total amount of time that was spent in bed. Retraction of the rotator cuff tear was classified using the Patte staging system. Results: This study included 36 patients: 18 with Patte stage 1 disease, 14 with Patte stage 2 disease, and 4 patients with Patte stage 3 disease. During the study, 25 participants wore the monitor on multiple nights, and ultimately their data was used for the analysis. No difference in the median sleep efficiency was appreciated amongst these groups (P>0.1), with each cohort of patients demonstrating a generally high sleep efficiency. Conclusions: The severity of retraction of the rotator cuff tear did not appear to correlate with changes in sleep efficiency for patients (P>0.1). These findings can better inform providers on how to counsel their patients who present with complaints of poor sleep in the setting of full-thickness rotator cuff tears.

Effect of Rice Straw Treatment and Nitrogen Split Application on Nitrogen Uptake by Direct Seeding on Dry Paddy Rice (벼 건답직파 재배시 볏짚처리 및 질소분시가 질소 흡수에 미치는 영향)

  • Lee, Kyeong-Bo;Kim, Sun-Kwan;Kang, Jong-Gook;Lee, Deog-Bae;Kim, Jong-Gu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.4
    • /
    • pp.309-313
    • /
    • 1997
  • Field experiments were conducted on Jeonbug series (Fine silty, mesic family of Aeric Fluventic Haplaquepts), to study the effect of split application of N fertilizer in combination with rice straw on N use efficiency of dry-soil-direct seeded paddy rice. Treatments involved conventional application of N (in three splits; 40% at planting, 30% at five leaf stage and at heading stage) without rice straw, all basal application of N with straw application (5000 kg/ha), N application in two splits (70% at planting and 30% at heading stage) with rice straw application and N application in three splits (40% at planting, 30% at five leaf stage, 30% at heading stage) with application of rice straw. There was Zero N plot too for the estimation of N use efficiency. Seeding was done on dry soil and the filed was flooded 32 days after seeding. The fertilizer application rates were 160, 70, and 80 kg/ha of N, $P_2O_5$ and $K_2O$, respectively. The experiment was conducted for two years, in the same filed. The apparent use efficiency of fertilizer N by rice tended to be higher under the application of rice straw when N was applied in three splits. This, however, did not increase the yield of rice significantly. Even under the application of rice straw, the apparent N use efficiency was lower when N fertilizer was applied in one dose at the planting and in two splits. The lower N use efficiency in these cases, did not yield of rice significantly. The periodical analysis of mineral N in the soil suggested that higher mineral N in the soil at the early stages was responsible for the lower apparent N use efficiency.

  • PDF

Power Factor Correction of the Single Stage AC/DC Converter with Low Conduction Loss and High Efficiency (고효율, 저손실을 갖는 1단 교류/직류 변환기의 역률제어)

  • 류명효;차영길;최병조;김흥근
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.418-422
    • /
    • 1998
  • A new single stage AC/DC converter based on the forward converter is proposed. The proposed converter offers both the high power factor and the direct conversion from ac line to dc output voltage. Also, the proposed converter reduces the diode conduction loss, so improves the overall efficiency of the converter, compared with other alternatives. The principles of operation and the simulation results of the proposed converter are presented. A 100 W prototype was built and tested to show the potential of applications of the proposed converter.

  • PDF

A Continuous Process of Persulfate Oxidation and Citric acid Washing for the Treatment of Complex-Contaminated Soil Containing Total Recoverable Petroleum Hydrocarbons and Heavy Metals (TRPHs - 중금속 복합오염토양의 동시 처리를 위한 과황산 산화 - 구연산 세척 혼성공정 개발)

  • Yoon, Na Kyeong;Choi, Jiyeon;Shin, Won Sik
    • Journal of Environmental Science International
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • A continuous process of persulfate oxidation and citric acid washing was investigated for ex-situ remediation of complex contaminated soil containing total recoverable petroleum hydrocarbons (TRPHs) and heavy metals (Cu, Pb, and Zn). The batch experiment results showed that TRPHs could be degraded by $Fe^{2+}$ activated persulfate oxidation and that heavy metals could be removed by washing with citric acid. For efficient remediation of the complex contaminated soil, two-stage and three-stage processes were evaluated. Removal efficiency of the two-stage process (persulfate oxidation - citric acid washing) was 83% for TRPHs and 49%, 53%, 24% for Cu, Zn, and Pb, respectively. To improve the removal efficiency, a three-stage process was also tested; case A) water washing - persulfate oxidation - citirc acid washing and case B) persulfate oxidation - citric acid washing (1) - citric acid washing (2). In case A, 63% of TRPHs, 73% of Cu, 60% of Zn, and 55% of Pb were removed, while the removal efficiencies of TRPHs, Cu, Pb, and Zn were 24%, 68%, 62%, and 59% in case B, respectively. The results indicated that case A was better than case B. The three-stage process was more effective than the two-stage process for the remediation of complex-contaminated soil in therms of overall removal efficiency.

Study of Mechanism of Counter-rotating Turbine Increasing Two-Stage Turbine System Efficiency

  • Liu, Yanbin;Zhuge, Weilin;Zheng, Xinqian;Zhang, Yangjun;Zhang, Shuyong;Zhang, Junyue
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.3
    • /
    • pp.160-169
    • /
    • 2013
  • Two-stage turbocharging is an important way to raise engine power density, to realize energy saving and emission reducing. At present, turbine matching of two-stage turbocharger is based on MAP of turbine. The matching method does not take the effect of turbines' interaction into consideration, assuming that flow at high pressure turbine outlet and low pressure turbine inlet is uniform. Actually, there is swirl flow at outlet of high pressure turbine, and the swirl flow will influence performance of low pressure turbine which influencing performance of engine further. Three-dimension models of turbines with two-stage turbocharger were built in this paper. Based on the turbine models, mechanism of swirl flow at high pressure turbine outlet influencing low pressure turbine performance was studied and a two-stage radial counter-rotation turbine system was raised. Mechanisms of the influence of counter-rotation turbine system acting on low-pressure turbine were studied using simulation method. The research result proved that in condition of small turbine flow rate corresponding to engine low-speed working condition, counter-rotation turbine system can effectively decrease the influence of swirl flow at high pressure turbine outlet imposing on low pressure turbine and increases efficiency of the low-pressure turbine, furthermore increases the low-speed performance of the engine.

Effects of flow variation in the first stage nozzle on the performance of a partial arc admission in a steam turbine (증기터빈 1단 노즐의 조속현상이 터빈성능에 미치는 영향)

  • Yoon, In-Soo;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.60-65
    • /
    • 2008
  • Power plant industry has been developed at high-capacity, high-technology, and innovation. Steam turbine became the most useful equipment that dominate more than 50% of all the world electricity production. And developed new materials of the turbine blade and extended length of the turbine last blade brought reform in steam turbine performance upgrade. In this paper, when do partial load driving in high-capacity steam turbine, optimum driving method found whether there is something. In operating steam turbine, there is a lot of loss from secondary wake and throttle of the 1st stage nozzle by the biggest leading factor that load fluctuation affects in high-pressure steam turbine performance. Effect of internal efficiency by 1 stage nozzle is the biggest here, but here fluid flow and flow analysis were not yet examined closely definitely. So, Analyzed design data and acceptance performance test result to applying subcritical pressure drum type 560 MW, supercritical-pressure once through type 500 MW, and 800 MW steam turbines actually. In conclusion, at partial load driving, partial arc admission(PAA) is more efficient than full arc admission(FAA) efficiency. This is judged by because increase being proportional with gross energy of stream that is pressure - available energy if pressure of stream that is flowed in to the turbine increases, available energy becomes maximum and turbine efficiency improves. Therefore, turbine performance is that preview that first stage performance fell if decline is serious in partial load because first stage performance changes according to load.

  • PDF

A Study on How General Super Markets Affect Traditional Markets Performance

  • Yoo, Byong-Kook;Kim, Soon-Hong
    • Journal of Distribution Science
    • /
    • v.15 no.11
    • /
    • pp.49-57
    • /
    • 2017
  • Purpose - In Korea, general super markets have a great impact on the market performance of traditional markets. We propose a modified two stage DEA model for evaluating the performance of traditional markets in Incheon, Korea by identifying the influence of external environmental factors including the presence of general super markets as non-discretionary variables in DEA. Research design, data, and methodology - After obtaining bias-corrected estimates of original DEA efficiency scores using the input and output data of 49 traditional markets, we regress them on several external environmental factors by bootstrap-truncated regression. Results - We obtain bias-corrected efficiency scores from the original DEA efficiency scores by bootstrap and among the five environmental factors, the residential population and the presence of general super markets or SSMs can be considered as the driving forces influencing bias-corrected efficiency scores, positively and negatively, respectively. Conclusions - When DEA efficiency scores tend to be overestimated, we need to use a biased-corrected efficiency score by bootstrap. It is important to note that the efficiency of traditional markets can be largely influenced by external environmental factors such as the presence of general super markets or SSMs that traditional markets can not control. Therefore, it is desirable to consider such environmental factors appropriately for a reasonable performance evaluation.

Effects of the Block Arrangement on the Collection Efficiency in the Two-Stage Electrostatic Precipitator with Charging Plate (평판형 방전판을 갖는 2단식 전기집진기의 집진판 블록배열이 집진효율에 미치는 영향)

  • 박성호;박청연;김태권
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.641-652
    • /
    • 2000
  • The effect of block arrangement has been investigated on the particle deposition in the specified collecting cell of two-stage electrostatic precipitator by numerical analysis. Recirculation zone existed at the downstream of the block in the collecting cell, and the particles entering the recirculation zone were deposited on the collecting plate. Particle trajectory and deposition had considerably different phenomenon according to electrostatic and inertial effect, which depended on inlet mean velocity, electrostatic number, and particle diameter in the collecting cell. The total collection efficiency reached a minimum value through an interaction of electrostatic and inertial effect. In the computational domain, total collection efficiency for the case of two blocks in the computational domain was more than that of one block at the relative small electrostatic number. However as the block distance and inertial effect increased, the difference between the collection efficiency of two cases decreased. In the range of relatively small particle size total collection efficiency was always superior to particle collection efficiency that was predicted by Deutsch equation.

  • PDF

An Input-Powered High-Efficiency Interface Circuit with Zero Standby Power in Energy Harvesting Systems

  • Li, Yani;Zhu, Zhangming;Yang, Yintang;Zhang, Chaolin
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1131-1138
    • /
    • 2015
  • This study presents an input-powered high-efficiency interface circuit for energy harvesting systems, and introduces a zero standby power design to reduce power consumption significantly while removing the external power supply. This interface circuit is composed of two stages. The first stage voltage doubler uses a positive feedback control loop to improve considerably the conversion speed and efficiency, and boost the output voltage. The second stage active diode adopts a common-grid operational amplifier (op-amp) to remove the influence of offset voltage in the traditional comparator, which eliminates leakage current and broadens bandwidth with low power consumption. The system supplies itself with the harvested energy, which enables it to enter the zero standby mode near the zero crossing points of the input current. Thereafter, high system efficiency and stability are achieved, which saves power consumption. The validity and feasibility of this design is verified by the simulation results based on the 65 nm CMOS process. The minimum input voltage is down to 0.3 V, the maximum voltage efficiency is 99.6% with a DC output current of 75.6 μA, the maximum power efficiency is 98.2% with a DC output current of 40.4 μA, and the maximum output power is 60.48 μW. The power loss of the entire interface circuit is only 18.65 μW, among which, the op-amp consumes only 2.65 μW.