• Title/Summary/Keyword: Stage Separation

Search Result 410, Processing Time 0.028 seconds

Study on a Spin Stabilization Technique Using a Spin Table (스핀테이블을 이용한 스핀안정화 기법 연구)

  • Kim, Dae-Yeon;Suh, Jong-Eun;Han, Jae-Hung;Seo, Sang-Hyeon;Kim, Kwang-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.5
    • /
    • pp.419-426
    • /
    • 2018
  • For an orbit transfer in a space exploration mission, a solid or liquid rocket booster is included at the last stage of the launch vehicle. During the orbit transfer, thrust misalignment can cause a severe orbit error. Three axis attitude control or spin stabilization can be implemented to minimize the error. Spin stabilization technique has advantages in structural simplicity and lightness. One of ways to apply the spin stabilization to the payload is to include a spin table system in the launch vehicle. In this paper, effect of the spin table system on separation dynamics of the payload is analyzed. Simple model of the spin table to mimic basic functions is designed and simulation environment is established with the model. Effect of the spin table is tested by evaluating separation dynamics of a payload with and without the spin table. Analysis on tolerance effect of separation spring constant on separation dynamics of a payload is conducted.

Highly Efficient Biogas Upgrading Process Using Polysulfone Hollow Fiber Membrane at Low Temperature (폴리술폰 중공사막을 이용한 바이오가스 고순도화 고효율 저온 분리 공정)

  • Kim, Se Jong;Han, Sang Hoon;Yim, Jin Hyuk;Lee, Chung Seop;Chang, Won Seok;Kim, Gill Jung;Ha, Seong Yong
    • Membrane Journal
    • /
    • v.32 no.2
    • /
    • pp.140-149
    • /
    • 2022
  • In this study, the conditions of low temperature and high pressure of biogas upgrading process using polysulfone membrane have been designed and tested to achieve the high recovery and efficiency corresponding to those of the highly selective polymeric materials. Polysulfone hollow fiber membrane with 4-component dope solution was spun via non-solvent induced phase separation. The hollow fiber membrane was mounted into a 1.5 inch housing. The effective area was 1.6 m2, and its performance was examined in various operation temperatures and pressures. CO2 and CH4 permeances were 412 and 12.7 GPU at 20℃, and 280 and 3.6 GPU at -20℃, respectively, while the CO2/CH4 selectivity increased from 32.4 to 77.8. Single gas test was followed by the mixed gas experiments using single-stage and double stage where the membrane area ratio varied from 1:1 to 1:3. At the single-stage, CH4 purity increased and the recovery decreased as the stage-cut increased. At the double stage, the area ratio of 1:3 showed the higher CH4 recovery as decreasing the operation temperature at the same purity of CH4 97%. Finally, polysulfone hollow fiber membranes have yielded of both CH4 purity and recovery of 97% at -20℃ and 16 barg.

Photovoltaic Performance of Crystalline Silicon Recovered from Solar Cell Using Various Chemical Concentrations in a Multi-Stage Process (습식 화학 공정에 의한 태양전지로부터 고순도 실리콘 회수 및 이를 이용한 태양전지 재제조)

  • Noh, Min-Ho;Lee, Jun-Kyu;Ahn, Young-Soo;Yeo, Jeong-Gu;Lee, Jin-Seok;Kang, Gi-Hwan;Cho, Churl-Hee
    • Korean Journal of Materials Research
    • /
    • v.29 no.11
    • /
    • pp.697-702
    • /
    • 2019
  • In this study, using a wet chemical process, we evaluate the effectiveness of different solution concentrations in removing layers from a solar cell, which is necessary for recovery of high-purity silicon. A 4-step wet etching process is applied to a 6-inch back surface field(BSF) solar cell. The metal electrode is removed in the first and second steps of the process, and the anti-reflection coating(ARC) is removed in the third step. In the fourth step, high purity silicon is recovered by simultaneously removing the emitter and the BSF layer from the solar cell. It is confirmed by inductively coupled plasma mass spectroscopy(ICP-MS) and secondary ion mass spectroscopy(SIMS) analyses that the effectiveness of layer removal increases with increasing chemical concentrations. The purity of silicon recovered through the process, using the optimal concentration for each process, is analyzed using inductively coupled plasma atomic emission spectroscopy(ICP-AES). In addition, the silicon wafer is recovered through optimum etching conditions for silicon recovery, and the solar cell is remanufactured using this recovered silicon wafer. The efficiency of the remanufactured solar cell is very similar to that of a commercial wafer-based solar cell, and sufficient for use in the PV industry.

Application of Umbilical System for Launch Vehicle (우주 발사체 엄빌리칼 시스템의 현황 및 적용사례)

  • Kim, Dae Rae;Lim, Chankyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.21-25
    • /
    • 2017
  • The umbilical system used for launch vehicle is to connect all ground supply lines (Pneumatic, hydraulic and electrical) to launch vehicle and disconnect those at few second before launch vehicle lift-off (or simultaneously with launch vehicle lift-off). During launch preparation stage, all umbilical shall be securely connected and also at separation stage, separation of all umbilical line shall be guaranteed. Therefore finding an appropriate connection force is a key factor on development of umbilical system. According to these design requirement, various kind of umbilical system has been developed from early stage of space development till today. In this paper, various kind of umbilical system developed so far is introduced according to its feature and operational concept. Also, umbilical system used for KSLV-II is introduced

  • PDF

Solvent Extraction Separation of Co, Mn and Zn from leaching solution from Ni-Cd battery by Na-PC88A

  • Ahn Jong-Gwan;Park Kyoung-Ho;Sohn Jeong-Soo;Kim Dong-Jin;Lee Jaereyeong;Jeong HunSaeong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.618-623
    • /
    • 2003
  • Solvent extraction experiments for separation of impurities from Ni-rich solution were carried out for manufacturing of high purity Ni compounds from acid leaching solution of spent Ni-Cd secondary battery. Artificial and leaching solutions were used as aqueous phases and PC88A saponified by sodium in kerosene were used as organic phase. The extraction order is Zn>Mn>Co>Ni and extraction percentage of metal ions was increased with increase of the concentration of extractant, initial pH of aqueous phase and ratio of O/A. The separation of cobalt, zinc and manganese from nickel was effectively accomplished at the condition of extraction stage=l, O/A=1 and initial pH 5.0 with 1.0 $mol/dm^3$ PC88A saponified to $50\%$ with NaOH.

  • PDF

An Experimental Study on the Quality Estimation of the Mortar using High-Quality Recycled Sand Producted from the Manufacturing System by Wet Gravity Separation (습식비중분리시스템에서 생산된 고품질 순환모래를 사용한 모르타르의 품질평가에 관한 실험적 연구)

  • Lee, Ji-Hwan;Rho, Hyoung-Nam;Lee, Jong-suk;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.103-107
    • /
    • 2008
  • This study was to execute the experiment for analyzing the quality characteristics of mortar by type of recycled sand by using the recycled sand produced by the manufacturing system by wet gravity separation in order to develop the removal device of impurities for the production of high-quality recycled sand. As a result, this study has sown that the mortar using the high-quality recycled sand through the manufacturing system by wet gravity separation in the fluidity property, strength property, and shrinkage property largely, compared with the mortar using low-quality recycled sand that not passed the device of sand flux. There was a tendency similar to the plane mortar. In conclusion, it was considered as various quality performances of the recycled sand were improved through the production stage of prototype.

  • PDF

Independent Component Analysis(ICA) of Sleep Waves (수면파형의 독립성분분석)

  • Lee, Il-Keun
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.1
    • /
    • pp.67-71
    • /
    • 2001
  • Independent Component Analysis (ICA) is a blind source separation method using unsupervised learning and mutual information theory created in the late eighties and developed in the nineties. It has already succeeded in separating eye movement artifacts from human scalp EEG recording. Several characteristic sleep waves such as sleep spindle, K-complex, and positive occipital sharp transient of sleep (POSTS) can be recorded during sleep EEG recording. They are used as stage determining factors of sleep staging and might be reflections of unknown neural sources during sleep. We applied the ICA method to sleep EEG for sleep waves separation. Eighteen channel scalp longitudinal bipolar montage was used for the EEG recording. With the sampling rate of 256Hz, digital EEG data were converted into 18 by n matrix which was used as a original data matrix X. Independent source matrix U (18 by n) was obtained by independent component analysis method ($U=W{\timex}X$, where W is an 18 by 18 matrix obtained by ICA procedures). ICA was applied to the original EEG containing sleep spindle, K-complex, and POSTS. Among the 18 independent components, those containing characteristic shape of sleep waves could be identified. Each independent component was reconstructed into original montage by the product of inverse matrix of W (inv(W)) and U. The reconstructed EEG might be a separation of sleep waves without other components of original EEG matrix X. This result (might) demonstrates that characteristic sleep waves may be separated from original EEG of unknown mixed neural origins by the Independent Component Analysis (ICA) method.

  • PDF

Implementation of Blind Source Recovery Using the Gini Coefficient (Gini 계수를 이용한 Blind Source Recovery 방법의 구현)

  • Jeong, Jae-Woong;Song, Eun-Jung;Park, Young-Cheol;Youn, Dae-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • UBSS (unde-determined blind source separation) is composed of the stages of BMMR (blind mixing matrix recovery) and BSR (blind source recovery). Generally, these two stages are executed using the sparseness of the observed data, and their performance is influenced by the accuracy of the measure of the sparseness. In this paper, as introducing the measure of the sparseness using the Gini coefficient to BSR stage, we obtained more accurate measure of the sparseness and better performance of BSR than methods using the $l_1$-norm, $l_q$-norm, and hyperbolic tangent, which was confirmed via computer simulations.

Evaluation on Crack in Self-leveling Material and Investigation about Influence of Specimen Size - Evaluation Method about Surface Layer Quality of Concrete Floor Groundwork Corresponding to Defect in Self-leveling Material (Part I) - (콘크리트 바닥 시험체의 크기가 SL재의 균열에 미치는 영향 - SL재의 하자 발생에 영향을 미치는 콘크리트 표층부의 품질 평가방법(I) -)

  • Kim, Doo-Ho;Choi, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.2 s.24
    • /
    • pp.99-106
    • /
    • 2007
  • The purpose of this study presents in Relations between cracks in self-leveling material and quality of floor groundwork surface are experimentally examined. As the first stage, the experiment to observe cracks in self-leveling material constructed on floor groundwork made from various kinds of concrete was carried. As a result, following basic findings were obtained. First, observation of cracks should be continued until an increase in width of cracks stop, without constructing any finishing material. Second, degree of cracks may be indicated quantitatively by the product of length and width. Finally, Cracks and separation is not be influenced by specimen size. Based on these findings, the method of predicting cracks by evaluating surface layer quality of floor groundwork will be established.

Enrichment of Oxygen and process engineering aspects using polysulfone hollowfiber membrane (폴리수폰 중공사막에 의한 산소농축 및 공정변수의 영향)

  • 조정식;김종수;이광래
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.65-66
    • /
    • 1997
  • 1. 서론 : 현재의 막분리 기술로는 단 단계 분리공정(single-stage separation)으로 약 40%의 산소농축공기(oxygen-enriched air)를 얻을 수 밖에 없지만 심냉법(cryogenic techniques)보다는 에너지 소비율이 적으며, 공정이 비교적 간단하기 때문에 용도에 따라 순 산소를 꼭 필요로 하지 않는 제철소, 발전소 등의 연소분야, 호흡기 환자를 위한 의료분야, 생물공학이나 항공기 분야 등에 편리하게 이용될 수 있다. 이와 같이 용도가 다양한 산소를 분리막을 이용하여 보다 편리하고 값싸게 얻기 위해서는 산소와 질소의 막투과에 대한 새로운 지식을 얻고 막투과가 기체의 어떤 성질에 지배되고 있는가를 조사할 필요가 있다. 본 연구에서는 고무상 고분자막(rubbery polymer membrane)에 대한 산소/질소의 수착특성과 순수한 기체의 투과율(permeation rate)을 기초로 하여 혼합기체의 투과율, 분리인자(separation factor), 막분리 공정변수에 의한 중공사 분리막에서의 기체분리특성에 대하여 연구하였다.

  • PDF