• 제목/요약/키워드: Stacking Area

검색결과 137건 처리시간 0.029초

새로운 방법으로 제조된 적층구조 $BaTiO_3$ 박막의 전기적 특성에 관한 연구 (Study on the electric properties of layered $BaTiO_3$ films prepared new stacking method)

  • 송만호;이윤희;한택상;오명환;윤기현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1129-1132
    • /
    • 1995
  • In the preparation of the layered $BaTiO_3$ thin films with high performance, the new stacking method using the continuous cooling of the substrate was introduced. Amorphous/polycrystalline $BaTiO_3$ layered structure was confirmed by SEM and index of refraction. The layered $BaTiO_3$ thin films formed by the new stacking method showed such a high dielectric constant that the layered structure could not be explained by a stacking structure of the two defined layers but could only be explained by multi-layered structure, i.e. amorphous/micro crystalline/polycrystalline structure. The layered $BaTiO_3$ thin film with a thickness of 240 nm showed higher capacitance per unit area and breakdown strength than the double layered $BaTiO_3$ thin film prepared by the conventional stacking method. And well defined ferroelectric hysteresis leer was observed in the layered $BaTiO_3$ thin film with a thickness of 200 nm.

  • PDF

대학도서관 자료실의 자료영역 및 열람영역 면적계획과 이용자 만족도 연구 (A Study on the Area Planning of Data Area and Reading Area and User Satisfaction in Subject Specialization of University Libraries)

  • 장아리;황연숙
    • 한국실내디자인학회논문집
    • /
    • 제23권5호
    • /
    • pp.157-164
    • /
    • 2014
  • The subject specialization room will be able to support university library users who are inclined to use the general reading room. This study is the research of the area planning for university library's subject specialization room. For the evaluation, 431 users from 15 university libraries in 14 universities located across Seoul were surveyed. Statistical analysis was performed using SPSS. Frequency, percentage, mean, t-test, f-test were used. Results of the study are as follow. Subject specialization rooms in university libraries can be classified via the analysis of spatial characteristics. According to the area ratio of data space and reading space in a subject specialization room, the subject room can be separated into data-loaning and data-reading types. Old libraries are more likely to be data-loaning types, where reading room is small and there are a lot of bookshelves. The annual increase in library collections causes space for bookshelves to decrease. As a result, space for reading has been gradually transformed into space for stacking data. It is necessary to introduce ways to maintain enough space for both reading and stacking data. One way includes movable compact shelving, which can partially replace existing fixed shelves.

Ni-36.5at.%Al 합금에서 V 첨가가 파괴거동 및 마르텐사이트 내부조직에 미치는 영향 (The Influence of Vanadium Addition on Fracture Behavior and Martensite Substructure in a Ni-36.5at.%Al Alloy)

  • 김영도;최주
    • 분석과학
    • /
    • 제5권2호
    • /
    • pp.203-211
    • /
    • 1992
  • Ni-36.5at.%Al 합금에서 결정립계에서의 scavenging 원소로 알려진 V를 첨가하여 이 합금의 파괴거동 및 마르텐사이트 미세조직에 미치는 V의 영향에 대해 조사하였다. 시편의 파단면은 주사전자현미경으로 관찰하였고 EDX spectrometer를 사용하여 파단면의 조성을 분석하였으며 투과전자현미경으로 마르텐사이트 내부조직의 변화에 대해 조사하였다. V의 첨가로 입계파괴에서 입내파괴로 파괴 모드의 변화를 나타내었으며 EDX spectrometer로 분석한 결과 입내에 비해 입계에 Al의 함량이 상대적으로 증가되는 양상을 보여 주었다. Ni-36.5at.%Al 합금의 경우 마르텐사이트 플레이트는 내부쌍정으로 이루어져 있으나 V의 첨가에 따라 twinned 마르텐사이트 조직은 사라지며 stacking fault와 고밀도의 전위를 가진 modulated 조직이 점차 지배적으로 형성되는 것이 관찰되었다. Stacking fault를 분석한 결과 Al과 V의 치환에 따른 extrinsic fault였으며 high-energy 상태인 이 stacking fault가 있는 부위에 유해 원소인 S가 편석됨으로써 결정립계에서의 파괴를 줄일 수 있었다.

  • PDF

탄소섬유강화플라스틱의 적층구성에 따른 드릴 가공에 관한연구 (A study on the Drilling according to the Stacking Sequence of the CFRP)

  • 김선범;신형곤;김태영
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.1-7
    • /
    • 2011
  • The CFRP composite has a lot of merits such as mechanical characteristic, light and thermal resistance. For these merits, CFRP is applied to so many industrial area. In order to use the composite materials in the aircraft structures or machine elements, accurate surfaces for bearing mounting or joints must be provided, which require precise, machining. In this study, the specimens differentiating the stacking sequence of 5kinds were used. When drilling the carbon fiber reinforced plastics, it was checked on whether the stacking sequence reached any effect on the cutting force. Also relationship between the drill diameter is examined from the drilling experiment, which is the drilling of Fabric, Unidirectional specimen with ∅6mm, ∅10mm, ∅12mm cemented carbide drill. Considering cutting force and drilling diameter, the results are analyzed.

인공발(Prosthetic Foot) 스프링용 유리섬유강화 적층재의 적층배향에 따른 층간분리거동 해석 (Analysis of Delamination Behavior on the Stacking Sequence of Prosthetic Foot Keel in Glass fiber Reinforced Laminates)

  • 송삼홍;김철웅
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.623-631
    • /
    • 2003
  • It is considered that the application of advanced composite materials to the prostheses for the disables is important to improve their bio-mechanical performance. Particularly, energy storing foot prosthesis is mostly important to restore gait ability of the disables with low-extremity amputation since it could provide propulsion at terminal stance enhancing the disables ability to walk long distance even run and jump. Therefore, the energy storing spring of Prosthetic foot keel under cyclic bending moment use mainly of high strength glass fiber reinforced plastic. The main objective of this study was to evaluate the stacking sequence effect using the delamination growth rate(dA$_{D}$/dN) of energy storing spring in glass fiber reinforced plastic under cyclic bending moment. The test results indicated that the shape of delamination zone depends on stacking sequence in GFRP laminates. Delamination area(A$_{D}$) turns out that variable types with the contour increased non-linearly toward the damage zones.nes.

탄소섬유복합평판에 낙추충격을 가할 때 적층구성에 미치는 영향에 관한 연구 (A Study on the Influence of Stacking Sequences using CFRP Laminate Plates by Falling Weight Impact)

  • 임광희;박노식;양인영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.106-109
    • /
    • 2000
  • Impact tester was build up to evaluate the characterization of CFRP laminate plates under the low velocity impact. The tests were conducted on several laminates of different ply orientation A system was budded for the impact strength of CFRP laminates in consideration of stress wave propagation theory using drop-weight impact tester as one of impact test. Results indicate that absorbed energy of quasi-isotropic specimen having four interfaces is higher than that of orthotropic laminates with two interfaces. Also the damage area was measured with ultrasonic C-scanner on some samples. In the specimens the relationship was linear between damaged area and absorbed energy to some degree. Absorbed energy in the specimen that ply number, interface number and fiber stacking sequences is same but having hybrid is higher than that of orthotropic laminates without hybrid.

  • PDF

하이브리드 복합재료의 섬유배향각이 피로균열 및 층간분리 거동의 관계에 미치는 영향 (The Effect of Fiber Stacking Angle on the Relationship Between Fatigue Crack and Delamination Behavior in a Hybrid Composite Materials)

  • 송삼홍;김철웅
    • 대한기계학회논문집A
    • /
    • 제28권3호
    • /
    • pp.281-288
    • /
    • 2004
  • The hybrid composite material (Al/GFRP laminates) are applied to the fuselage and wing in a aircraft. Therefore, Al/GFRP laminates suffer from the cyclic bending moments. This study was to evaluate the effect of fiber stacking angle on the fatigue crack propagation and delamination behavior using the relationship between crack growth rate (da/dN) and stress intensity factor range (ΔK) in Al/GFRP laminates under cyclic bending moment. The variable delamination growth behavior in case of three different type of fiber orientations, i.e., [Al/O$_2$/Al], [Al/+45$_2$/Al] and [Al/90$_2$/Al] at the interface of Al layer and glass fiber layer was measured by ultrasonic C-scan images. As results of this study, It represent that the delamination shape should turns out to have more effective characteristics on the fiber stacking angle. The extension of the delamination zone in case of [Al/+45$_2$/Al] and [Al/90$_2$/Al] were not formed along the fatigue crack profile. The shape of delamination zone depend on fiber stacking angle and the variable type with the delamination contour decreased non-linearly toward the crack tip at the Al layer.

미소-위치 배열 중합을 이용한 지진파의 잡음제거 (Seismic Noise Reduction Using Micro-Site Array Stacking)

  • 최훈;손상욱;배현덕
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.395-403
    • /
    • 2014
  • This paper presents a new approach to improve the signal to noise ratio (SNR) for local seismic disaster preventing system in densely populated area. The seismic data measured in the local site includes various sensing noises (offset or measurement noise) and man-made/natural noises (road and rail traffic noise, rotating or hammering machinery noise, human activity noise such as walking and running, wind/atmospheric pressure-generated noise, etc.). These additive noises are different in time and frequency characters. The proposed method uses 3-stages processing to reduce these different additive noises. In the first stage, misalignment offset noise are diminished by time average processing, and then the second and third stages, coherent/incoherent noises such as man-made/natural noises are suppressed by array stacking. In addition, we derived the theoretical equation of the SNR gain improved by the proposed method. To evaluate the performance of the proposed method, computer simulations were performed with real seismic data and test equipment generated data as the input.

태양전지 보호유리가 태양전지 성능에 미치는 영향 (Effect of Solar Cell Cover Glass on Solar Cell Performance)

  • 최영진;왕진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1421-1423
    • /
    • 1996
  • In this study, the effect of solar cell cover glass on the solar cell performance is evaluated. Silicon solar cell (active area:4*6cm, efficiency:12.6% at AMO condition) is used for this study. ITO(Indium tin Oxide) film thickness of the ITO/AR/substrate glass/solar cell structure samples are $40{\AA}$, $60{\AA}$, $160{\AA}$, $240{\AA}$ respectively. The solar cell maximum output power on the stacking structure variations showed 465mW in the AR/ITO/substrate glass/solar cell, and minimum output power showed 403mW in the AR/substrate glass/solar cell. The maximum output power of the solar cell on the ITO thickness variations of the ITO/AR/substrate glass/solar cell showed 460mW at $40{\AA}$ then decrease output power as ITO thickness increase. For environment tests, all samples are exposed UV light in the vacuum chanber. The output power degradation of AR(UVR)/substrate glass/solar cell stacking structure is small compared with ITO/AR(UVR)/substrate glass/solar cell stacking structure.

  • PDF

적층 배열형상에 따른 BSCCO 적층선재의 자화손실 특성 수치해석 및 측정 (Numerical Analysis and Measurement of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry)

  • 박명진;임형우;이광연;차귀수;이지광
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권2호
    • /
    • pp.83-88
    • /
    • 2006
  • AC loss is one of the main research area in AC power application using high temperature superconductor(HTS), such as HTS transformer, HTS current limiter and HTS cable, because it is closely related to efficiency, economic estimation and design of power device. A lot of research for various arrangements of HTS tapes have been performed to increase a capacity of transport current because single HTS tape can not satisfy the demanded current capacity in HTS power application. In this paper, we studied magnetization loss by different several arrangements of BSCCO tapes such as Edge-to-Edge type, Face-to-Face type and Matrix type through numerical analysis by 2D-FEM and measurement. As a result, we got the result that the magnetization loss of Face-to-Face type arrangements was lower than those of other arrangement types under the conditions of the same stacking number. We think that the result was due to shield effect by demagnetization of adjacent HTS tapes which are located face to face.