• 제목/요약/키워드: Stack performance

검색결과 621건 처리시간 0.056초

용융탄산염형 연료전지 발전시스템 구성 및 운전 (Constitution and Operation of a Molten Carbonate Fuel Cell System)

  • 안교상;김동형;설진호;임희천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.100-103
    • /
    • 1997
  • Korea Electric Power Corporation (KEPCO) started a fuel cell project to develop alternative sources of electric power because of the rapid increase in power demand and global environmental problems. For the development of a molten carbonate fuel cell (MCFC), KEPCO started the project in 1993 to develop a 2 kW MCFC system and finished it at the end of 1996. In this project, $ASPEN^+$ was utilized to design the 2 kW MCFC generation system. Based on this simulation, a power generation system was designed and installed for operation and a long term test of internally manifolded 2 kW class MCFC stack. This stack has 20 cells with an effective electrode area of $1000\;cm^2$. It was run at 0.84 V and $150\;mA/cm^2$ and was operated for more than 3,250 hours continuously. This paper describes the system configuration and its control and measurement units. An analysis of the stack performance, the effect of gas utilization ratio, and the stack performance requirements are also discussed.

  • PDF

고층건물에서 연돌효과 및 외기풍속에 따른 배연창의 배연성능 평가 (The Performance Evaluation of Natural Smoke Ventilators Due to Stack Effect and Wind Velocities in High-rise Buildings)

  • 임채현;김범규;박용환
    • 한국화재소방학회논문지
    • /
    • 제23권6호
    • /
    • pp.82-90
    • /
    • 2009
  • 본 연구에서는 화재 시 효과적인 연기배출을 위해 국내 건축법에서 규정하고 있는 배연창이 고층건물의 연돌효과 및 배연성능에 미치는 영향을 분석하기 위해 현장실험과 모델링 해석을 병행하였다. 현장실험은 배연창이 설치된 고층건물을 대상으로 정상조건 및 배연창 개방조건에서 외기온도에 따른 계단실, 부속실 및 복도에서의 압력분포 측정을 통해 연돌효과를 분석하였다. 모델링 해석에서는 연기유동 해석용 네트워크모델인 CONTAMW을 이용하여 모델링결과 및 실험결과의 비교분석을 통한 보정기밀도를 적용하여 이상적인 대상건물을 구현하고 배연창의 배연성능을 평가하였다.

Bounding Worst-Case Data Cache Performance by Using Stack Distance

  • Liu, Yu;Zhang, Wei
    • Journal of Computing Science and Engineering
    • /
    • 제3권4호
    • /
    • pp.195-215
    • /
    • 2009
  • Worst-case execution time (WCET) analysis is critical for hard real-time systems to ensure that different tasks can meet their respective deadlines. While significant progress has been made for WCET analysis of instruction caches, the data cache timing analysis, especially for set-associative data caches, is rather limited. This paper proposes an approach to safely and tightly bounding data cache performance by computing the worst-case stack distance of data cache accesses. Our approach can not only be applied to direct-mapped caches, but also be used for set-associative or even fully-associative caches without increasing the complexity of analysis. Moreover, the proposed approach can statically categorize worst-case data cache misses into cold, conflict, and capacity misses, which can provide useful insights for designers to enhance the worst-case data cache performance. Our evaluation shows that the proposed data cache timing analysis technique can safely and accurately estimate the worst-case data cache performance, and the overestimation as compared to the observed worst-case data cache misses is within 1% on average.

동적 스택시스템의 설계와 성능분석 (On the Design and Performance Analysis of Dynamic Stack Systems)

  • 정치봉
    • 한국정보처리학회논문지
    • /
    • 제2권3호
    • /
    • pp.364-373
    • /
    • 1995
  • 본 논문은 동적 자료구조의 확률론적 운영방식의 설계와 그 성능분석의 이론적 접근 방법을 제시한다. 즉 m개의 셀로서 구성된 일련의 연속된 블록에 두 개의 스택 을 할당하여 공유하는 시스템의 확률적 운용방식의 효율성을 해석적 방법에 의한 성 능분석을 통하여 그 결과를 제시한다. 특히 스택 원소의 삽입과 제거는 스택의 현재 의 크기에 따라 빈도를 달리하는 방식을 제안한다. 따라서 두 스택의 충돌까지 스택 조작 횟수의 평균과 분산등 통계적 특성을 희소 사건 확률 계산이론에 의하여 m$\longrightarrow$$\infty$ 일 때 점근적 결과를 제시한다. 또한 유한상태기계, 컴퓨터 및 정보 시스템의 성능 분석에 응용할 수 있는 보다 일반적인 방법을 고찰한다.

  • PDF

A study on the seismic performance of reinforced concrete frames with dry stack masonry wall using concrete block

  • Joong-Won Lee;Kwang-Ho Choi
    • Earthquakes and Structures
    • /
    • 제24권3호
    • /
    • pp.205-215
    • /
    • 2023
  • Currently, many studies are underway at home and abroad on the seismic performance evaluation and dry construction method of the masonry structure. In this study, a dry stack masonry wall system without mortar using concrete blocks is proposed, and investigate the seismic performance of dry filling wall frames through experimental studies. First, two types of standard blocks and key blocks were designed to assemble dry walls of concrete blocks. And then, three types of experiments were manufactured, including pure frame, 1/2 height filling wall frame, and full height filling wall frame, and cyclic load experiments in horizontal direction were performed to analyze crack patterns, load displacement history, rebar deformation yield, effective stiffness change, displacement ductility, and energy dissipation capacity. According to the experimental results, the full height filling wall frame had the largest horizontal resistance against the earthquake load and showed a high energy dissipation capacity. However, the 1/2 height filling wall frame requires attention because the filling wall constrains the effective span of the column, limiting the horizontal displacement of the frame. In addition, the concrete block was firmly assembled in the vertical direction of the wall as the horizontal movement between the concrete blocks was allowed within installation margin, and there was no dropping of the assembled concrete block.

장기운전에 의한 직접메탄올 연료전지 스택의 성능 열화 분석 (Diagnosis of Performance Degradation of Direct Methanol Fuel Cell Stack after Long-Term Operation)

  • 김상경;현민수;이병록;정두환;백동현;임성엽
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.775-780
    • /
    • 2011
  • 50 $cm^2$의 활성면적을 가진 셀을 이용하여 5-셀 DMFC 스택을 제작하고 4 A의 부하로 4,000 시간 운전한 후 성능감소 및 성능 감소 원인을 분석하였다. 4,000 시간 운전 후 10 A에서 스택의 전력 밀도가 28.7% 감소하였으며 다섯개의 셀 중 두 개는 거의 성능저하가 일어나지 않았고 두 개는 약 40%의 성능 저하, 한 개는 약 60%의 성능 저하를 보였으며 각 셀별 성능저하의 정도의 차이는 스택 내에서의 위치와 상관관계가 없었다. 스택 내의 다섯 셀 중 가장 성능감소가 심하였던 셀의 경우 연료극 촉매층의 Pt 입자 크기가 증가하였으며 연료가 들어가는 쪽의 Pt 입자의 크기 증가가 더 심하였다. 그러나 4,000 시간 장기운전 후 공기극 촉매층에서는 Pt 입자 크기의 변화는 거의 없었다. 스택 내의 모든 셀에서 4,000 시간 운전 후 연료극 촉매에서 공기극 촉매로의 루테늄의 크로스오버가 SEM-EDX로 관찰되었으며 특히 성능감소가 심하였던 셀의 경우 공기극 촉매층에서 Ru/Pt의 비율이 가장 컸다.

자바 객체의 스택 저장 가능성 판별을 위한 정적 분석 기법 (Escape Analysis for Stack Allocation in Java)

  • 조은선
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제31권6호
    • /
    • pp.840-848
    • /
    • 2004
  • 자바에서 사용이 끝난 객체의 수집(garbage collection)은 프로그래머의 메모리 관리 부담을 덜어준다는 장점이 있다. 그러나, 수행 속도에 영향을 미치게 되므로 정적 분석 기법을 사용하여 이를 극복하는 기법이 제안되어왔다. 이 중 하나인 스택 저장 기법은, 힙메모리 대신 메소드 스택에 저장될 수 있는 객체들을 수행 전에 분석하여 파악해두는 방식을 따른다. 본 논문에서는 메소드의 호출/반환에 대해 직접 분석하여 자신을 생성한 메소드의 반환 후에도 접근될 소지가 있는 객체들을 판별하는 정적 분석 기법을 제시한다. 이로써 객체와 변수의 지정(assignment) 관계 분석을 기준으로 하는 기존의 스택 저장 기법들에서 간과되었던 객체들 중에서도 스택에 저장할 수 있는 대상을 발견할 수 있도록 한다.

공급유량 및 스택온도의 변이에 따른 200W급 PEM형 연료전지의 전기적 성능특성 (Electrical Performance Characteristics of 200W PEM-Type Fuel Cells with Variations on Mass Flow Rate and Stack Temperature)

  • 홍경진;박세준;최용성;이경섭
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.563-567
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEM-type FCs system was integrated by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with variations on mass flow rate and stack temperature. The ranges of the variations are 1~8L/min on $H_2$ volume and $20{\sim}70^{\circ}C$ on stack temperature.

10kW급 인산형 연료전지 제작 및 운전 특성 (Fabrication and Operational Characteristics of 10kW Class PAFC)

  • 송락현;김창수;신동열;최수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1543-1545
    • /
    • 1998
  • In order to develop PAFC stack technology using 2.000$cm^3$ electrode-matrix, 10kW stack consisted of 63 single cell was fabricated and operated. The operation installation, and control and data acquision system for the 10kW PAFC stack were designed and equipped. The stack showed the performance of 10kW (275A at 36.5V) and uniform distribution of temperature and voltage between the cells.

  • PDF

Design of 1500V solar inverter stack beyond megawatt in NPC1 topology

  • Hao, Xin;Ma, Kwok-Wai;Zhao, Jia;Sun, Xin-Yu
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.7-11
    • /
    • 2017
  • This paper describes a design concept of NPC1 power stack for 1500VDC megawatt level solar inverter. This stack uses three latest half-bridge IGBT modules with highest power density and operation junction temperature, which enable realization of power level beyond 1MW without paralleling. Critical design concept on loop inductance is explained. Dynamic characteristics are verified by double-pulse test. Thermal characteristics and output power limits are verified by thermal test. Temperature-sensitive component on PCB as output power constraint is identified. Different PCB repositioning solutions are tested to give the overall output power thermal derating curves, which enable output power of 1.15MW at $T_A=55^{\circ}C$ with $15^{\circ}C$ thermal margin. The power stack characteristic and performance change under different thermal environment is further analyzed.

  • PDF