• Title/Summary/Keyword: Stack effect

Search Result 324, Processing Time 0.023 seconds

The Study on the Solution of Stack effect in the Vertical shaft of High-rise Buildings (고층건축물 수직 샤프트 연돌효과 해소방법에 대한 연구)

  • Kim, Jin-Soo;Chang, Hee-Chul
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.242-245
    • /
    • 2007
  • Stack effects occurred in the stairwell, an important evacuation means of the high-rise building, give a big impact on stairwell pressure difference distribution and it could obstruct evacuation from the building, so should be controlled within proper range. Computer simulation was conducted with CONTAMW2.4 to find the solution of stack effects of the high-rise building. It was able to solve the imbalance pressure difference with a pressurization and a depressurization supplied by fans on higher and lower parts of the stairwell.

  • PDF

Issues Related to the Modeling of Solid Oxide Fuel Cell Stacks

  • Yang Shi;Ramakrishna P.A.;Sohn Chang-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.391-398
    • /
    • 2006
  • This work involves a method for modeling the flow distribution in the stack of a solid oxide fuel cell. Towards this end, a three dimensional modeling of the flow through a Solid Oxide Fuel Cell (SOFC) stack was carried out using the CFD analysis. This paper examines the efficacy of using cold flow analysis to describe the flow through a SOFC stack. It brings out the relative importance of temperature effect and the mass transfer effect on the SOFC manifold design. Another feature of this study is to utilize statistical tools to ascertain the extent of uniform flow through a stack. The results showed that the cold flow analysis of flow through SOFC might not lead to correct manifold designs. The results of the numerical calculations also indicated that the mass transfer across membrane was essential to correctly describe the cathode flow, while only temperature effects were sufficient to describe the anode flow in a SOFC.

Analysis of Causes of and Solutions to the Stack Effect by Vertical Zoning of High-rise Buildings (초고층 건축물 수직조닝별 연돌효과의 원인 및 해결 방안 분석)

  • Shin, Sang Wook;Ryu, Jong Woo;Jeong, Hee Woong;Kim, Dae Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.483-493
    • /
    • 2021
  • Urban overcrowding has created an explosive supply and demand for high-rise buildings. High-rise buildings are contributing to enhancing the image of the city by serving as focal points, but due to the stack effect, malfunction of elevator doors, difficulties in opening and closing the doors and windows of the outer wall, smoke and odors spreading to the upper floors, noise, energy loss, fire and pollutants have been causing various unexpected problems such as rapid spread of fire. This study classified high-rise buildings according to their vertical zoning, analyzed the causes of and solutions to the stack effect, and derived design and construction methods. Through the initial plan to block the outside air and securing airtightness through precise construction, we sought ways to secure the airtightness inside and outside the building by actively blocking the airflow from the lower floors. In addition, the facility solution can be a measure to reduce the specific phenomena caused by the stack effect, but it should only be applied to the minimum extent because the potential for secondary damage is high. This study emphasized the need for systematic stack effect management by suggesting design and construction measures for each vertical zoning of the causes and countermeasures of the stack effect. It is expected that this study will be helpful not only for design and construction, but also for building maintenance.

Stack Effect Mitigation Methods in Exit Route of High-rise Building (고층 건축물 피난경로의 연돌효과 저감 방안)

  • Kim, Jin-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.284-288
    • /
    • 2010
  • Length of staircase get longer and evacuation load get heavier in proportion to the building height. Therefore evacuation time could be considered proportional to square of building height. While smoke spreads vertically so rapidly, evacuation speed is too slow, therefore the reasonable measure for the safe of egress route is urgent. Existing pressurizing smoke control system of vertical exit route is seriously limited in function under the stack effect in winter. Stack effect in winter could be overcome with the methods of opening the staircase outward or letting airflow be free between staircase and outside.

  • PDF

Analysis of the Condenser Stack Effect in a High-Rise Apartment Building (고층 아파트에서 응축기 적층문제 분석)

  • 최석호;이관수;김인규;이동혁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.796-803
    • /
    • 2004
  • The stack effect of a new type condenser installed in a high-rise apartment building was studied numerically A sirocco fan is introduced to the new type condenser instead of an axial flow In. The new type condenser intakes the cold air through the lower inlet and exhausts the hot air through the upper outlet. The effects of the building height and frontal wind on the performance of an air-conditioner were analyzed. The performance of an air-conditioner was evaluated by using COP (coefficient of performance) and CGPI (condenser group performance indicator). the hot air was exhausted by the new type condenser at an angle of 50$^{\circ}$ from the outer wall of the building. If there was no draft, the new type condenser installed in the high-rise apartment building had a good performance and its performance on each floor is not influenced by the stack effect. It is shown that the efficiency of the air-conditioner installed in several floors below the top floor decreased when the frontal wind velocity was greater than 8 m/s.

A Numerical Analysis on the Indoor Air Ventilation by Stack Effect and Outdoor Wind in a High-rise Residential Building (초고층 주거건물에서 굴뚝효과와 외풍영향에 인한 실내 환기 기류해석 및 평가에 관한 연구)

  • Kim, Chi-Wan;Lim, Tae-Kun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.828-835
    • /
    • 2011
  • The purpose of this study is to analyze and evaluate the 3 types of indoor ventilation methods such as natural, mechanical, and hybrid ventilation in high-rise building which is affected by stack effect and outdoor air pressure. For the evaluation of the ventilation capacity, CFD simulation was performed in a typical high-rise residential building. The results of the simulations are as follows: 1) Natural ventilation method is not enough to the regulation. 2) In case of mechanical ventilation, congested area is occurred but meets the regulation. 3) In case of hybrid ventilation with stack effect, all the areas of indoor meet the regulation and congested area is reduced. 4) In case of high-rise building, the differences of ventilation rate among houses in the building are not large because the mechanical ventilation is main factor.

The Performance Evaluation of Natural Smoke Ventilators Due to Stack Effect and Wind Velocities in High-rise Buildings (고층건물에서 연돌효과 및 외기풍속에 따른 배연창의 배연성능 평가)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.82-90
    • /
    • 2009
  • Natural smoke ventilator is one of domestic prescriptive methods to be used to exhaust smoke in case of fire in a high-rise buildings. The goal of this study is to evaluate the stack effect and the smoke exhaust performance in high-rise buildings with the opening of natural smoke ventilators using computer modeling technology, thus to estimate its effectiveness as a tool of smoke exhaust. For this purpose, the pressure differential in a domestic high-rise building with natural smoke ventilators was experimentally measured to analyze the stack effect with the closure or the opening of natural smoke ventilators and to calculate compensated air leakage of the building. Computer modeling based on experimentally measured data was carried out to estimate effectiveness of natural smoke ventilators in high-rise buildings using CONTAMW network program.

Vestibule Smoke Control Considering the Stack Effect and the Opening of the Outside Door (굴뚝효과와 외부출입문 개방을 고려한 부속실 제연)

  • Yongkwang Kim;Zudal Son;Seoyoung Kim;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.15-24
    • /
    • 2024
  • The purpose of this study is to improve the stack effect of the staircase and the failure to take into account the opening of the outside door of the staircase, which are the disadvantages of the existing smoke control only vestibule. As a result of the study, the new vestibule and the staircase simultaneous smoke control are equipped with an exhaust flap damper with an effective opening area of about 0.25 m2 in the upper part of the staircase, and a ventilator-type air supply fan of about 5 m3/s in the lower part, and take measures to prevent overpressure in the staircase. If you use the new simultaneous smoke control method of the vestibule and staircase, you can achieve the following effects. First, it is possible to open the external entrance door. Second, it can reduce the stack effect. Third, the staircase door closes automatically without fail. And a new method of preventing overpressure was proposed for the vestibule.

Effect of Field Orientation on Magnetization Loss in a Stacked Bi-2223 Conductor (자장방향이 적층 Bi-2223도체의 자화손실에 미치는 영향)

  • 류경우;김현준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.1
    • /
    • pp.77-82
    • /
    • 2003
  • The ac loss is an important issue in the design of high-Tc superconducting power devices such as transformers and cables. In these devices many Bi-2223 tapes are closely stacked together and exposed to alternating magnetic fields that can have different orientations with respect to a tape. In such arrangement the magnetization loss is influenced by the screening current induced in adjacent tapes and thus different from that in a single tape. This stacking effect was experimentally investigated by measuring the magnetization loss in a stack, which consists of a number of tapes. First the magnetization loss in the single tape was measured in order to confirm the reliability of the loss data measured in the stack. The results for the single tape coincide well will the loss characteristics described in other previous works. For the stack In parallel and longitudinal magnetic fields the measured loss is Independent of both the number of tapes and stacking type. The longitudinal magnetization loss Is well explained rather by the slab model for decoupled filaments. For the tall stack in perpendicular field the measured loss at low fields is greatly decreased, compared to the loss of the single tape. However the loss at high fields is unaffected. These loss behaviors in the tall stack are well described by the slab model for full coupling.

Study on the Performance Evaluation of the Exhaust Stack used in High Riser Public House (초고층공동주택 국소배기용 입상덕트의 배기성능평가에 관한 연구)

  • Kwon, Yong-il;Lee, Tae-Kyu;Ahn, Jung-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.889-894
    • /
    • 2008
  • Exhaust system used in toilet and cooking place of high riser public house is roof fan of two basic types : natural roof ventilator and natural/forced roof ventilator. Natural/forced roof ventilator has a motor in the rotary shaft. There are many high riser public house in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depend on stack effect. This study investigates on stack pressure determined by exterior pressure and the difference pressure control in exhaust stack used in high riser public house. This paper focuses mainly on the effect of the time interval for power supply of motor installed in roof fan with function of natural wind velocity and of exhaust air volume of toilet. It is observed there are higher exhaust efficiency than the existing natural roof ventilator.

  • PDF