• Title/Summary/Keyword: Stack effect

Search Result 324, Processing Time 0.028 seconds

Technology Development of Noise Reduction at Stack for Resolution of Abnormal Noise (이상소음 해소를 위한 Stack 소음저감 기술개발)

  • Ho, Kyong-Chan;Lee, Young-Je;Kim, Sung-Jin;Kwon, Hycuk-Kwan;Jung, Hyun-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1049-1052
    • /
    • 2006
  • Object of this study is to develop an Stack Silencer System for quieting abnormal noise around power plant. Abnormal noise gets resident people to feel uncomfortable. Stack Silencer System is to minimize pressure loss of exhaust gas and to maximize noise reduction effect from abnormal noise frequency band. Stack Silencer System is installation in stack and absorbing material is an aluminum foam. Reduction effect measures insertion loss of $8.2{\sim}19.4dB$ by Stack silencer installation. After Stack Silencer System installation, pressure loss of exhaust gas measured $5{\sim}9mmH_2O$.

  • PDF

Numerical Analysis on Pressurization System of Smoke Control in Consideration of Stack Effect (연돌효과를 고려한 급기가압 제연시스템의 수치해석 연구)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-6
    • /
    • 2013
  • When the pressurization system that uses difference of pressure for smoke control is designed, the factors influencing on the pressure field in building should be applied to design process and the stack effect is one of the main factors. Numerical analysis based on network model in 20-story building is carried out to analyze the pressurization system of smoke control in consideration of stack effect. Calculations are conducted for three conditions, that is, stack effect only, pressurization only and stack effect plus pressurization. Results including the detailed pressure field and flow rate at each floor are represented and the stack effect are effectively visualized. Meanwhile, the pressure of stairwell is increased as much as the summation of the stack effect and pressurization, and the problem induced by rise of pressure is pointed out.

A Study on Reduction Method of Stack Effect at Stairwell of High-Rise Building (고층건물 피난계단에서의 연돌효과 저감방안 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.14-20
    • /
    • 2011
  • As the height of the building increases, the stack effect in stairwell that is main facilities for evacuation becomes stronger. While the pressure rise in stairwell causes difficulties on opening the door for evacuation and has effect on smoke control system, reduction of stack effect will be necessary for providing more safe evacuation environment. The field experiments on pressure field in high-rise building are carried out to present reduction method of stack effect and the numerical analyses using network model are proceeded to design quantitatively the reduction method. As the air flow supplied from outside in lower stair and exhausted to outside in upper stair is formed in stairwell, the stack effect in stairwell is expected to be decreased.

The Effect of Stack Clamping Pressure on the Performance of a Miniature PEMFC Stack (소형 고분자 연료전지 스택의 체결압력에 따른 성능 특성)

  • Kim, Byung-Ju;Yim, Sung-Dae;Sohn, Young-Jun;Kim, Chang-Soo;Yang, Tae-Hyun;Kim, Young-Chai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.6
    • /
    • pp.499-504
    • /
    • 2009
  • The effect of gas diffusion layer (GDL) compression caused by different stack clamping pressures on fuel cell performance was experimentally studied in a miniature 5-cell proton exchange membrane fuel cell (PEMFC) stack. Three stacks with different GDL compressions, 15%, 35% and 50%, were prepared using SGL 10BC carbon fiber felt GDL and Gore 57 series MEA. The PEMFC stack performance and the stack stability were enhanced with increasing stack clamping pressure resulting in the best performance and stability for the stack with higher GDL compressions up to 50%. The excellent performance of the stack with high GDL compression was mainly due to the reduced contact resistance between GDL and bipolar plate in the stack, while reduced gas permeability of the excessively compressed GDL in the stack hardly affected the stack performance. The high stack clamping pressure also resulted in excessive GDL compression under the rib areas of bipolar plate and large GDL intrusion into the channels of the plate, which reduced the by-pass flow in the channels and increase gas pressure drop in the stack. It seems that these phenomena in the highly compressed stack enhance the water management in the stack and lead to the high stack stability.

A Study on the Thermal Phenomena and Stack Effect of Nude Elevator Shaft of High Rise Building that used CFD (CFD를 이용한 초고층빌딩 누드 엘리베이터의 온열 및 연돌현상에 관한 연구)

  • Park, Jung-Han
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1059-1064
    • /
    • 2008
  • The present study is to reduce the thermal phenomena and stack effect of nude elevator of the high-rise building used CFD simulation. Since many High-rise buildings used the curtain-wall glass, thermal phenomena and stack effect can easily occur at hot and cold season, respectively. The simulation has been conducted and verified for the effects of the amount of suppling air to the environment of the inside nude elevator shaft. The results of simulations show that the problems due to the thermal and stack effect will be reduced by enforced ventilation or natural ventilation and those will be presented by temperature and velocity profiles and pressure differences.

  • PDF

A Numerical Study on the Influence of the Shaft Geometry on the Stack Effect (수직통로의 형상이 연돌효과에 미치는 영향에 관한 수치해석 연구)

  • Jeon, Heung-Kyun;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.74-81
    • /
    • 2011
  • The numerical analyses for three different shafts in geometry of high buildings were carried out by using computational fluid dynamics model (FDS ver.5.3) for the calculation of the pressure difference and the location of the neutral plane and the visualization of stack effect. At 10 seconds of stack effect, the pressure difference of stack effect in the elevator shaft (79.3 Pa) almost corresponded to the theoretical value (78 Pa). At 300 seconds of stack effect, all the neutral planes of three cases were located about 49 m above floor, where was 5 m higher than the theoretical value. The maximum pressure difference between upper and lower position of shaft decreased with increasing of the geometrical complexity of shaft. This study showed that there was the difference of the stack effects among the geometries of shafts with the visualization of stack effect.

Analysis of impact factors affecting on the stack effect in high-rise building (고층빌딩 연돌 현상의 영향인자 분석)

  • Oh, Jin-Hwan;Song, Doo-Sam;Yoon, Sung-Min;Nam, Yujin
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: Recently, high-rise buildings are popular in korea due to high rate of land usage and cost performance in urban area. However, high-rise building causes several problems such as safety issues, cooling/heating load, stack effect, disaster prevention etc. The stack effect is one of the representative problems. Even though there are many researches on stack effect, there are few studies on design guideline considering local condition. Method: This study focuses on the change of pressure distribution according to the design factors which affects the airflow in high-rise residential buildings by simulation analysis. In this study, city, building floor, stairwell door leakage area, elevator door leakage area and changes of layout were considered ad the design factor. Result: The simulation results indicate that building height and ambient air temperature are significant design factor for stack effect.

A Study on Performance Improvement Measures of Pressurized Smoke Control Systems for Exit Passageways of High-Rise Buildings (고층건축물의 피난경로 가압제연시스템 성능개선대책에 관한 연구)

  • Son, Bong-Sae;Kim, Jin-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.703-714
    • /
    • 2009
  • One of the biggest problems in smoke control systems for high-rise buildings is stack effect, but there are no recognized methods or measures to solve the problem of stack effect as yet. The stack effect can be overcome by forming the uprising current inside the stair hall properly, but there is a limit to the height in supplying into the stair hall the smoke control air volume to be supplied to a floor in case of escape from fire. The limit to the height can be extended by over-coming the stack effect by pressurizing the stair hall and the ancillary room simultaneously. It can also be anticipated that the stack effect can be overcome by connecting the air supply shaft to the stair hall at the top. As a result of computer simulations using a network type of tool, it is found that adequate performance can be achieved by pressurizing the stair hall only for a building of 190m or less, and up to 360m when pressurizing the stair hall and the ancillary room simultaneously. In all those cases, however, an overpressure venting damper is required which operates within a suitable range for venting the overpressure outside.

Case Study of Analysis of Problems and Minimizing Methods of Stack Effect in the Tall Complex Building (초고층 복합건물의 연돌현상 가중요인과 저감방안 사례연구)

  • Yu, Jung-Yeon;Cho, Dong-Woo;Yu, Ki-Hyung;Jeong, Cha-Su;Kang, So-Yeon;Song, Kyoo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.363-368
    • /
    • 2006
  • The purpose of this case study is to analyze stack effect problems and to develop methods minimizing methods of stack effect in the tall complex building in cold climates. The main problems in the tall complex building occur in high-rise elevators. Such problems as elevator doors that do not close and exhaust airflows result in excessive pressure differences across elevator doors due to stack effect. Under the expected conditions causing these pressure differences, computer simulations with CONTAMW computer program and field measurements are performed in the tall complex building. The results are analyzed in architectural design aspects. With these analysis, the tall complex building design guidelines to minimize stack effect are proposed.

  • PDF

The Effects of the Inclination on the Performance of dead-end operating PEM Fuel Cell (고분자 연료전지의 데드엔드 운전 시 기울임에 따른 성능 변화)

  • Jeong, Jee Hoon;Kho, Back Kyun;Han, In-Su;Shin, Hyun Khil;Hur, Tae Uk;Cho, Sung Baek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.89.2-89.2
    • /
    • 2011
  • In automotive applicatons or water vehicles, the polymer electrolyte membrane fuel cell(PEMFC) stack is keep moving while their operation. Especially the inclination environment can take a effect to fuel cell stack perfromance, because this condition can cause a bad effect to water exhaust of fuel cell stack. In this study, a large scale stack(over 100kW power) is inclined upto 30 degree in lengthwise and crosswise using stack lift equipment. And the stack is operated in 10~100% load. No significant change has appeared in crosswise inclined condition and lenthwise low angle. But in lenthwise large angle tilting condition, the fuel cell performance has significantly decreased. And this performance decrease is aggravated in low load. An active water exhaust device is applied to the stack to prevent the performance decrease. And in lenthwise large angle tilting condition, this device cause a good effect to fuel cell stack performance.

  • PDF