• 제목/요약/키워드: Stack

검색결과 2,241건 처리시간 0.035초

Experimental study on the interaction force between a permanent magnet and a superconducting roll stack

  • Wenxin Li;Tianhui Yang;Ying Xin
    • Progress in Superconductivity and Cryogenics
    • /
    • 제25권1호
    • /
    • pp.11-15
    • /
    • 2023
  • In recent years, the interaction force between a permanent magnet and a closed superconductor coil has been gradually investigated in depth. The principle and application potential of an energy storage/convertor composed of a magnet and a closed superconducting coil have been proved. However, the study on the force between a magnet and a non-closed superconducting coil (superconducting roll stack) has hardly been reported in previous literature. The behavior of this kind of interaction and its influence to the interaction force between a permanent and a closed superconducting coil are also still unclear. In this paper, first we investigated the interaction force between a magnet and a superconducting roll stack. Then, a series of experiments were designed and conducted to clarify the factors affected the interaction force, including the geometrical parameters of the superconducting roll stack and the magnetic field density at the roll stack. Moreover, the comparison of the interaction forces between the magnet and roll stack or a closed coil was also introduced.

Analysis of OpenStack Heat Orchestration Technology-HOT Template (OpenStack 오케스트레이션 기술 분석-HOT 템플릿)

  • Jeon, H.S.;Kim, B.S.;Lee, B.C.
    • Electronics and Telecommunications Trends
    • /
    • 제30권2호
    • /
    • pp.95-103
    • /
    • 2015
  • 오픈스택(OpenStack)을 이용한 클라우드 서비스가 점차 확산되어가면서 수많은 가상 자원들을 생성하고 생성된 가상 자원들의 라이프사이클을 관리하는 오케스트레이션 기능의 중요성이 강조되고 있다. 본고에서는 오픈스택 진영에서 템플릿 기반의 오케스트레이션 서비스를 담당하고 있는 Heat의 기본구조와 함께 Heat에서 정의하고 있는 HOT(Heat Orchestration Template) 템플릿의 구성 요소와 주요 특징을 정리하고 템플릿 간에 참조 관계를 설명하는 Nested Stack 개념을 소개한다.

  • PDF

Vibration Characteristics of Piezoelectric Stack Transducers (적층 압전 변환기의 진동 특성)

  • Kim, Dae Jong;Kim, Jin Oh
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.66-68
    • /
    • 2014
  • The paper deals with the vibration characteristics of the stack transducers made of piezoelectric discs with different radius. Natural frequencies of the stack transducers were evaluated by finite-element analysis. The natural frequencies of the analysis results were compared with those of each piezoelectric disc, and their relations were investigated.

  • PDF

The Operating Results of the 75kW MCFC Stack (75kW 용융탄산염 연로전지[MCFC] 스택 운전 결과)

  • Kang, Seung-Won;Kim, Beom-Joo;Kim, Do-Hyeong;Lee, Jung-Hyun;Kim, Eui-Hwan;Lim, Hee-Chun
    • Journal of Hydrogen and New Energy
    • /
    • 제20권3호
    • /
    • pp.202-207
    • /
    • 2009
  • A 75kW MCFC stack with the reactive area of 9,600cm$^2$ has been operated and validated in Boryeong thermal power plant. The 75kW MCFC stack was installed at the end of November 28, 2008 and started initial operation on December 23, 2008 after pretreated for about 20 days. At initial load operation, the stack showed the Open Circuit Voltage of 137V, which approaches the theoretical value. At the early stage of rated power operation, the stack displayed the voltage of 104V at the current of 754A and reached the maximum generating power of 78.5kW DC. This stack has been operated for 2,890 hours until April, 2009. In addition, the operation time of rated power records 1890 hours. This Operating result is scheduled to be reflected the design of l25kW stack.

Development of a 25kW-Class PEM Fuel Cell System for the Propulsion of a Leisure Boat (선박 추진용 25kW급 고분자전해질 연료전지 시스템 개발)

  • Han, In-Su;Jeong, Jeehoon;Kho, Back-Kyun;Choi, Choeng Hoon;Yu, Sungju;Shin, Hyun Khil
    • Journal of Hydrogen and New Energy
    • /
    • 제25권3호
    • /
    • pp.271-279
    • /
    • 2014
  • A 25kW-class polymer electrolyte membrane (PEM) fuel cell system has been developed for the propulsion of a leisure boat. The fuel cell system was designed to satisfy various performance requirements, such as resistance to shock, stability under rolling and pitching oscillations, and durability under salinity condition, for its marine applications. Then, the major components including a 30kW-class PEM fuel cell stack, a DC-DC converter, a seawater cooling system, secondary battery packs, and balance of plants were developed for the fuel cell system. The PEM fuel cell stack employs a unique design structure called an anodic cascade-type stack design in which the anodic cells are divided into several blocks to maximize the fuel utilization without hydrogen recirculation devices. The performance evaluation results showed that the stack generated a maximum power of 31.0kW while maintaining a higher fuel utilization of 99.5% and an electrical efficiency of 56.1%. Combining the 30-kW stack with other components, the 25kW-class fuel cell system boat was fabricated for a leisure. As a result of testing, the fuel cell system reached an electrical efficiency of 48.0% at the maximum power of 25.6kW with stable operability. In the near future, two PEM fuel cell systems will be installed in a 20-m long leisure boat to supply electrical power up to 50kW for propelling the boat and for powering the auxiliary equipments.

Implementation and design of Linux IPv6 Protocol Stack on GSM Phone (GSM Phone 상에서 Linux IPv6 프로토콜 스택 설계 및 구현)

  • Lee, Sang-Woo;Lim, Dong-Hwa;Han, Bosco;Rho, Sun-Ok
    • Journal of KIISE:Information Networking
    • /
    • 제34권1호
    • /
    • pp.16-26
    • /
    • 2007
  • It is well known that, in the near future, the lifetime of the IPv4 address space will be limited and available 32-bit IP network addresses will not be left my more. In order to solve such IPv4 address space problem in an effective way, the transition to the new version using IPv6 architecture is inevitably required. This paper presents the design and implementation of IPv4/IPv6 dual stack at the GSM Phone based on Linux Kernel 2.4 IPv6 Protocol Stack. It designs appropriately in GSM Phone environment and it is tested by a network of Linux IPv4/IPv6 dual stack on PPP. The test was processed with a test scenario and it was found that the results were successful.

Optimizing I/O Stack for Fast Storage Devices (고속 저장 장치를 위한 입출력 스택 최적화)

  • Han, Hyuck
    • The Journal of the Korea Contents Association
    • /
    • 제16권5호
    • /
    • pp.251-258
    • /
    • 2016
  • Recently, the demand for fast storage devices is rapidly increasing in cloud platforms, social network services, etc. Despite the development of fast storage devices, the traditional Linux I/O stack is not able to exploit the full extent of the performance improvement since it has been optimized for disk-based storage devices. In this paper, we propose an optimized I/O stack which can fully utilize the I/O bandwidth and latency of fast storage devices. To this end, we design a new I/O interface to replace the current block I/O interface and optimize our I/O interface. Our optimized I/O interface bypasses operations/layers in block I/O subsystems of the current Linux I/O stack to fully exploit fast storage devices. We also optimize the Linux file systems such as ext2 and ext4 to run on our I/O interface. We evaluate our I/O stack with multiple benchmarks and the experimental results show that our I/O stack achieves 1.7 times better throughput compared to traditional Linux I/O stack.

Development of High Performance LonWorks Based Control Modules for Network-based Induction Motor Control

  • Kim, Jung-Gon;Hong, Won?Pyo;Yun, Byeong-Ju;Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.414-420
    • /
    • 2005
  • The ShortStack Micro Server enables any product that contains a microcontroller or microprocessor to quickly and inexpensively become a networked, Internet-accessible device. The ShortStack Micro Server provides a simple way to add LonWorks networking to new or existing smart devices. . It implements the LonTalk protocol and provides the physical interface with the LonWorks communication. The ShortStack host processor can be an 8, 16, or 32-bit microprocessor or microcontrollers. The ShortStack API and driver typically require about 4kbytes of program memory on the host processor and less than 200 bytes of RAM. The interface between host processor and the ShortStack Micro Server may be a Serial Communication Interface (SCI). The LonWorks control module with a high performance is developed, which is composed of the 8 bit PIC Microprocessor for host processor and the smart neuron chip for the ShortStack Micro Server. This intelligent control board is verified as proceeding the various function tests from experimental system with an boost pump and inverter driving systems. It is also confirmed that the developed control module provides stably 0-10VDC linear signal to the input signal of inverter driving system for varying the induction motor speed. Thus, the experimental results show that the fabricating intelligent board carried out very well the various functions in the wide operating ranges of boost pump system. This developed control module expect to apply to industrial fields to require the comparatively exact control and monitoring such as multi-motor driving system with inverter, variable air volume system and the boost pump water supply systems.

  • PDF

A Numerical Study on the Influence of the Shaft Geometry on the Stack Effect (수직통로의 형상이 연돌효과에 미치는 영향에 관한 수치해석 연구)

  • Jeon, Heung-Kyun;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • 제25권4호
    • /
    • pp.74-81
    • /
    • 2011
  • The numerical analyses for three different shafts in geometry of high buildings were carried out by using computational fluid dynamics model (FDS ver.5.3) for the calculation of the pressure difference and the location of the neutral plane and the visualization of stack effect. At 10 seconds of stack effect, the pressure difference of stack effect in the elevator shaft (79.3 Pa) almost corresponded to the theoretical value (78 Pa). At 300 seconds of stack effect, all the neutral planes of three cases were located about 49 m above floor, where was 5 m higher than the theoretical value. The maximum pressure difference between upper and lower position of shaft decreased with increasing of the geometrical complexity of shaft. This study showed that there was the difference of the stack effects among the geometries of shafts with the visualization of stack effect.

Operation Characteristics and Analysis of Temperature Gradients in a 5-kW Molten Carbonate Fuel Cell Stack (5 kW 용융탄산염 연료전지 스택내 운전특성 및 온도 변화 해석)

  • Lim, Hee-Chun;Koh, Joon-Ho;Ryu, Jeong In
    • Journal of Hydrogen and New Energy
    • /
    • 제10권2호
    • /
    • pp.107-118
    • /
    • 1999
  • A 5-kW MCFC stack with $3,000cm^2$ electrode area was tested to investigate cell performance and operation characteristics. The stack performance was evaluated based on electrical output and I-V change. The stack showed high cell performance (7.6 kW) than the design performance and operated for more than 5,760 hours, but a significant temperature gradient inside the stack was observed. A 3-dimensional mathematical model for molten carbonate fuel cell (MCFC) was developed for the purpose of simulation of stack performance during the operation. The model was solved using PHOENICS, a computational fluid dynamics (CFD) code. The simulation result demonstrated a close prediction of the temperature gradient and stack performance.

  • PDF