Search Result 2,234, Processing Time 0.028 seconds

Effect of the a floor plan of lobby floor for the Stack Effect in a High-rise Building (고층건물에서 로비층의 평면형태가 연돌효과에 미치는 영향)

  • Lee, June-Ho;Lim, Hyun-Woo;Seo, Jung-Min;Lee, Joong-Hoon;Song, Doo-Sam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.293-299
    • /
    • 2009
  • Many kinds of problems by stack effect occur in the high-rise buildings that have the simple plan on the first floor designed only by an external wall and an E/V shaft wall. Therefore, some buildings in the foreign countries has made the additional inside walls between lobby and E/V hall as a countermeasure on stack effect. An additional wall in the lobby is very useful countermeasure on stack problems because lobby is a main airflow path in the building. Decreasing effect on stack problems by an additional wall of lobby is reported in this study. An ordinary office building that has a simple lobby plan is simulated and measured in this study. The results show that characteristics on stack effect are changed by methods of applying additional walls and that alternations of countermeasures which building conditions like the kinds of problems and the problem's velocity etc. are considered are very important.

  • PDF

Analysis and Experiment of Heat Conduction and Heat Pumping in a Thermo-Acoustic Refrigerator Stack (열음향 냉동기 스택에서의 열전도와 열펌핑의 해석 및 실험)

  • Ku, B.K.;Song, T.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.473-487
    • /
    • 1995
  • A loud speaker-driven zero-c.o.p. thermoacoustic refrigerator where an automotive catalytic converter is utilized as a stack has been fabricated and investigated experimentally. Without any heat exchangers at both ends of stack(and thus with zero c. o. p.), temperatures on the stack are measured and various heat transfer rates are calculated from the measured temperatures. Temperatures on the stack have been also calculated numerically using a finite difference method. The measured temperatures are in fair agreement with the calculated temperatures for lower frequency than 300Hz, however, the former deviates from the latter considerably for higher frequency. Two types of c. o. p. have been defined as appropriate to the experiment. While the nominal c. o. p. is zero(the condition in which the pumped heat flow rate in the pore exactly cancels the axial heat conduction down the stack), the true c. o. p. is found to be about 0.14 for 300Hz from the experiments.

  • PDF

Optimizing the Manifold Design of a Fuel Cell Stack for Uniform Distribution of Reactant Gases within Fuel Cell Channels (연료전지 채널 내 균일한 유량분배를 위한 연료전지 스택의 매니폴드 디자인 최적화 연구)

  • Jo, A-Rae;Kang, Kyung-Mun;Oh, Sung-Jin;Ju, Hyun-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.11-19
    • /
    • 2012
  • The main function of fuel cell manifold is to render reactants distribution as uniform as possible into a fuel cell stack. The purpose of this study is to numerically investigate the effects of stack manifold design on reactants distribution within a fuel cell stack. Four manifold designs with different manifold entrance shapes (expansion or diffuser) and different values of the extra width between the cell outer channel and manifold side wall are considered and applied to the fuel cell stack consisting of 50 cells. Since the fuel cell stack geometry involves several millions of grid points for numerical calculations, a parallel computing methodology is employed to substantially reduce the computational time and overcome the memory requirement. The numerical simulations are carried out and calculated results clearly demonstrate that both the manifold entrance shape and extra width have a substantial influence on manifold performance, controlling the degree of flow separation and entrance length for fully developed flow in the manifold channel. Finally, we suggest the optimum design of fuel cell manifold based on the simulation results.

Flow Field Design and Stack Performance Evaluation of the Thin Plate Separator for High Temperature Polymer Electrolyte Membrane Fuel Cell (고온 고분자전해질 연료전지 박판형 분리판의 유로 설계 및 스택 성능 평가)

  • KIM, JI-HONG;KIM, MINJIN;KIM, JINSOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.442-449
    • /
    • 2018
  • Research on High temperature polymer electrolyte fuel cell (HT-PEMFC) has actively been conducted all over the world. Since the HT-PEMFC can be operated at a high temperature of $120-180^{\circ}C$ using phosphoric acid-doped polybenzimidazole (PBI) electrolyte membrane, it has considerable advantages over conventional PEMFC in terms of operating conditions and system efficiency. However, If the thermal distribution is not uniform in the stack unit, degradation due to local reaction and deterioration of lifetime are difficult to prevent. The thin plate separator reduces the volume of the fuel cell stack and improves heat transfer, consequently, enhancing the cooling effect. In this paper, a large area flow field of thin plate separator for HT-PEMFC is designed and sub-stack is fabricated. We have studied stack performance evaluation under various operating conditions and it has been verified that the proposed design can achieve acceptable stack performance at a wide operating range.

The Results of the 125 kW External Reforming Type MCFC Stack Operation (125kW 외부개질 용융탄산염 연료전지(ER MCFC) 스택 운전)

  • Lee, Jung-Hyun;Kim, Beom-Joo;Kim, Do-Hyeong;Kang, Seung-Won;Kim, Eui-Hwan;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.5
    • /
    • pp.419-424
    • /
    • 2010
  • The 125kW external reforming (ER) type molten carbonate fuel cell (MCFC) system for developing a commercial prototype has been operated at Boryeong thermal power plant site since the end of 2009. The system consists of 125kW stack with $10,000 cm^2$ effective area, mechanical balance of plant (MBOP) with anode recycle system, and electrical balance of plant (EBOP). The 125kW MCFC stack installed in December, 2009 has been operated from January, 2010 after 20 days pre-treatment. The stack open circuit voltage (OCV) was 214V at initial load operation, which approaches the thermodynamically theoretical voltage. The stack voltage remained stable range from 160V to 180V at the maximum generating power of 120 kW DC. The stack has been operated for 3,270 hours and operated at rated power for 1,200 hours.

An Error Synchronization running on Gateway Software Stack based on CoAP (CoAP 기반 게이트웨이 소프트웨어 스택에서의 오류 동기화)

  • Ko, Eung-Nam
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.1
    • /
    • pp.114-119
    • /
    • 2016
  • The necessity of IoT(Internet of Things) and Multimedia CSCW is described, and error control for multimedia CSCW(Computer Supported Cooperated Works) based on CoAP stack is suggested. This paper describes an error synchronization running on gateway software stack based CoAP. This system consists of an CS_EDA, and CS_ESA. CS_EDA is an agent that detects an error for multimedia distance system based on gateway software stack based CoAP environment. CS_ESA is an agent that is an error synchronization system for multimedia distance control based on gateway software stack based CoAP environment. From the perspective of multimedia collaborative environment of gateway software stack based CoAP, an error application becomes another interactive presentation error is synchronized with participants engaged in a cooperative work.

Study on Environmental Monitoring in Stack Room for Paper Storage Using the Preservation Index (보존 환경 평가 지수를 이용한 종이 보존 서고 환경 모니터링 연구)

  • Shin, Hyun-Chang;Yoon, Man-Young
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.1
    • /
    • pp.61-74
    • /
    • 2011
  • Critical environmental elements for long term preservation of a paper are temperature, humidity, dust, light, contaminants in air, and mold. Especially, temperature and humidity need special care, because they can not only directly degrade paper but also affect the degradation of the other elements. Therefore methods to monitor variation of temperature and relative humidity were studied. One of the methods was to use preservation index for evaluating preservation environment. Since the evaluation for preservation environment of a stack room investigated firstly by D. K. Sebera, PI(preservation index) and TWPI(Time-Weighted Preservation Index) by IPI is made to evaluate relatively preservation environment in a stack room. T. Padfield developed method which could calculate easy PI and TWPI. In this study, the preservation environment of stack rooms for paper storage in NAK(National Archives Korea) was evaluated by PI and TWPI. PI and TWPI of stack rooms for paper storage in NAK maintained good condition but PI depended on season. Then the preservation environment of stack rooms for paper storage in NAK was required to maintain continuously PI and TWPI regardless of season change.

Effect of Laser Ablation on Rear Passivation Stack for N-type Bifacial Solar Cell Application (N형 양면 수광 태양전지를 위한 레이저 공정의 후면 패시베이션 적층 구조 영향성)

  • Kim, Kiryun;Chang, Hyo Sik
    • Korean Journal of Materials Research
    • /
    • v.30 no.5
    • /
    • pp.262-266
    • /
    • 2020
  • In this paper, we investigated the effect of the passivation stack with Al2O3, hydrogenated silicon nitride (SiNx:H) stack and Al2O3, silicon oxynitride (SiONx) stack in the n type bifacial solar cell on monocrystalline silicon. SiNx:H and SiONx films were deposited by plasma enhanced chemical vapor deposition on the Al2O3 thin film deposited by thermal atomic layer deposition. We focus on passivation properties of the two stack structure after laser ablation process in order to improve bifaciality of the cell. Our results showed SiNx:H with Al2O3 stack is 10 mV higher in implied open circuit voltage and 60 ㎲ higher in minority carrier lifetime than SiONx with Al2O3 stack at Ni silicide formation temperature for 1.8% open area ratio. This can be explained by hydrogen passivation at the Al2O3/Si interface and Al2O3 layer of laser damaged area during annealing.

Design and Implementation of MEARN Stack-based Real-time Digital Signage System

  • Khue, Trinh Duy;Nguyen, Thanh Binh;Jang, UkJIn;Kim, Chanbin;Chung, Sun-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.5
    • /
    • pp.808-826
    • /
    • 2017
  • Most of conventional DSS's(Digital Signage Systems) have been built based on LAMP framework. Recent researches have shown that MEAN or MERN stack framework is simpler, more flexible, faster and more suitable for web-based application than LAMP stack framework. In this paper, we propose a design and implementation of MEARN (ME(A+R)N) stack-based real-time digital signage system, MR-DSS, which supports handing real-time tasks like urgent/instant messaging, system status monitoring and so on, efficiently in addition to conventional digital signage CMS service tasks. MR-DSCMS, CMS of MR-DSS, is designed to provide most of its normal services by REST APIs and real-time services like urgent/instant messaging by Socket.IO base under MEARN stack environment. In addition to architecture description of components composing MR-DSS, design and implementation issues are clarified in more detail. Through experimental testing, it is shown that 1) MR-DSS works functionally well, 2) the networking load performance of MR-DSCMS's REST APIs is better compared to a well-known open source Xibo CMS, and 3) real-time messaging via Socket.IO works much faster than REST APIs.

Experimental study on the interaction force between a permanent magnet and a superconducting roll stack

  • Wenxin Li;Tianhui Yang;Ying Xin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.1
    • /
    • pp.11-15
    • /
    • 2023
  • In recent years, the interaction force between a permanent magnet and a closed superconductor coil has been gradually investigated in depth. The principle and application potential of an energy storage/convertor composed of a magnet and a closed superconducting coil have been proved. However, the study on the force between a magnet and a non-closed superconducting coil (superconducting roll stack) has hardly been reported in previous literature. The behavior of this kind of interaction and its influence to the interaction force between a permanent and a closed superconducting coil are also still unclear. In this paper, first we investigated the interaction force between a magnet and a superconducting roll stack. Then, a series of experiments were designed and conducted to clarify the factors affected the interaction force, including the geometrical parameters of the superconducting roll stack and the magnetic field density at the roll stack. Moreover, the comparison of the interaction forces between the magnet and roll stack or a closed coil was also introduced.