• Title/Summary/Keyword: Stable fracture

Search Result 277, Processing Time 0.032 seconds

FUNCTIONAL RECOVERY OF MANDIBULAR HIGH CONDYLAR FRACTURE PATIENT WITH IMMEDIATE PROVISIONAL IMPLANT: CASE REPORT (Immediate provisional implant를 이용한 하악골 high condylar fracture환자의 기능회복: 증례보고)

  • Jang, Bo-Young;Ahn, Mi-Ra;Ahn, Kyung-Mi;Lee, Won-Hyuk;Shon, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.1
    • /
    • pp.82-88
    • /
    • 2005
  • Treatment methods of mandibular condylar fracture were conservative and surgical method. Surgical method of mandibular high condylar fracture was very difficult because approach and internal fixation of small size fracture fragment were difficult. So there is a tendency to select conservative method over surgical method for guiding a stable occlusion and avoiding TMJ disorder and growth disturbance, minimizing pain and deviation during function. But, in case of mandibular high condylar fracture patient who has no biting teeth on posterior teeth area, guiding a stable occlusion and conservative functional treatment were very difficult. In this case, patient was 62years old male. He had fracture of mandibular symphysis, right mandibular body, left mandibular high condyle. We treated the patient for mandibular symphysis and right mandibular body fracture area with surgical method. But left mandibular high condylar fracture area was difficult to treat with surgical method. So we selected a conservative functional method on left mandibular high condylar fracture area. We intended recovery of vertical dimension and stable occlusion with implantation of immediate provisional implant on maxillar and mandibular posterior teeth area, and temporary crown. And then patient did mandibular functional movement and his mandibular function was recoverd.

Finite element fracture reliability of stochastic structures

  • Lee, J.C.;Ang, A.H.S.
    • Structural Engineering and Mechanics
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 1995
  • This study presents a methodology for the system reliability analysis of cracked structures with random material properties, which are modeled as random fields, and crack geometry under random static loads. The finite element method provides the computational framework to obtain the stress intensity solutions, and the first-order reliability method provides the basis for modeling and analysis of uncertainties. The ultimate structural system reliability is effectively evaluated by the stable configuration approach. Numerical examples are given for the case of random fracture toughness and load.

Fracture toughness of Low-carbon steel using J-intergral Principle (J-적분을 이용한 저탄소강의 파괴탄성치 결정)

  • ;;Kwak, Byung-Man
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.3 no.4
    • /
    • pp.133-142
    • /
    • 1979
  • The fracture toughness of a hot rolled 100 mm thick SS41 steel plate was investigated for various crack ratios and thichnesses using the method of J-integral. The experiments were performed on an MTS machine and the crack initiation point was detected by using an electricl impedance method. The J-integral computed at the initiation point of the slow stable crack growth was almost constant within the range of crack ratios tested. The fracture toughness thus obtained was $J_{1c}/=27.0kgf/mm$ for specimens having fracture plane parallel to the rolling direction and 35.5kgf/mm for those perpendicular to the rolling direction. The J- integral computed at maximum load point was found to be unsuitable for fracture toughness determination, becaese of large variation depending on the crack ratio and thickness. It was also found that the slow stable crack growth increases as the thickness and/or crack ration of the specimen decrease.

Surgical Management of a Mandible Subcondylar Fracture

  • Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.284-290
    • /
    • 2012
  • Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.

A Case Report on Burning Acupuncture Treatments for Stable Compression Fracture (화침을 이용한 흉요추부 압박골절 치험 1례)

  • Lee, Jong-Soo;Han, Soon-Hyun
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.3 no.1
    • /
    • pp.167-174
    • /
    • 2002
  • Stable compression fractures are most often caused by trauma as traffic accidents. Stable compression fractures can refer pain to the mid-back, which is characterized by the pain in the thoracolumbar spinous prosess. recently we experienced a 19 years old man who had lumbago originating from Stable compression fractures and condition was improved through burning acupunture.

  • PDF

The Evaluation of the Fracture Criterion having an Effect on Crack Extension Simulation for a Thin Sheet (박판시험편의 균열성장 시물레이션에 미치는 파괴기준 평가)

  • 권오헌
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.15-19
    • /
    • 2000
  • The exact estimation of the ductile crack growth in a thin sheet would be needed in part of the commercial transport aircraft industry fields. A 2-dimensional elastic plastic finite element analysis was carried out to simulate a stable crack extension in a thin sheet 2024 aluminium alloy. Two kinds of crack modeling were used to evaluate curves of the stable crack extension. And then CTOA(crack tip opening angle) and CTED(crack tip energy density) were calculated in order to determine whether they can be used as useful crack extension criterions in a thin sheet. Results indicate that stable crack extension behaviors were simulated well and CTED is more admirable even though CTOA also is reasonable as a criterion for a stable crack extension in a thin 2024 aluminium alloy sheet.

  • PDF

Prediction of Fracture Energy of Concrete

  • Oh, Byung-Hwan;Jang, Seung-Yup;Byun, Hyung-Kyun
    • KCI Concrete Journal
    • /
    • v.11 no.3
    • /
    • pp.211-221
    • /
    • 1999
  • A method to determine the fracture energy of concrete is investigated. The fracture energy may be calculated from the area under the complete load-deflection curve which can be obtained from a stable three-point bend test. Several series of concrete beams have been tested. The Present experimental study indicates that the fracture energy decreases as the initial notch-to-beam depth ratio increases Some problems to be observed to employ the three-point bend method are discussed. The appropriate ratio of initial notch-to-beam depth to determine the fracture energy of concrete is found to be 0.5. It is also found that the influence of the self-weight of a beam to the fracture energy is very small A simple and accurate formula to predict the fracture energy of concrete is proposed.

  • PDF

Mixed Mode Crack Propagation using the High Strength Concrete Disk (고강도 콘크리트 디스크를 이용한 혼합모드 균열전파)

  • 진치섭;김희성;박현재;김민철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.733-738
    • /
    • 2000
  • It is difficult to obtain accurate fracture toughness values by RILEM committees proposed three point bend test(TPB) because the shape of load-deflection curve is irregular and final crack propagation occurs after some slow stable cracking. However, for disk test, fracture toughness is easily obtained from crack initial load. We examined the cracked high strength concrete disk and the experimental results were compared with the results by finite element analysis(FEA). Also we compared experimental fracture locus with theoretical fracture locus.

  • PDF

An Evaluation of Fracture Toughness for SS400 Steel by R-curve and DCPD (R-곡선과 직류전위차(DCPD)에 의한 SS400강의 파괴인성 평가)

  • Jang Seok-Ki;Han Min-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.855-861
    • /
    • 2005
  • Fracture toughness defined near the initiation of stable crack growth is investigated by R-curve and Direct Current electric Potential Determination(DCPD) under mode I plane strain conditions for CT specimen with 25.4mm thickness of SS400 steel. Fracture toughness. $J_{IC}$lit near crack tip of CT specimen by R-curve is 17.14 $kg_{f}/mm$ and however. its value by DCPD is 22.82 $Rg_{f} mm$ The value of fracture toughness by DCPD is larger than that by R-curve. Therefore, it is suggested that the evaluation of fracture toughness by R-curve is optimum than by DCPD, when considering amount of crack growth about each of fracture toughness.

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.