• Title/Summary/Keyword: Stable Procedure

Search Result 540, Processing Time 0.024 seconds

Spectrophotometric Determination of Submicrogram Amounts of Orthophosphate Suitable for Water Analysis (水質分析을 目的한 極微量燐酸鹽의 高感度比色定量法)

  • Chong Hun Won
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.3
    • /
    • pp.113-120
    • /
    • 1964
  • The critical examination of the spectrophotometric method for determining microgram quantities of phosphate by the n-butyl acetate extraction as molybdophosphoric acid and subsequent development of the molybdenum blue has been made. In this procedure from 2 to 8 ${\mu}g$. of phosphate-phosphorus can be determined under optimum conditions. The final concentration of ammonium molybdate and the final acidity of perchloric acid for the formation of heteropoly acid are suitable to be ranges of 0.5 to 1.1% and 0. 5 to 1. 1 N respectively, and subsequently extracted with 10 ml. of n-butyl acetate. The extract is developed to molybdenum blue with 5.0 ml. of 1. 3% stannous chloride in 1N hydrochloric acid. The color is stable for at least one hour in the use of perchloric acid for the condensation. In order to determination of submicrogram amounts of phosphate, the sensitivity of the molybdenum blue method is hardly sufficient, a sensitive and stable molybdenum(V)-thiocyanate complex method has been investigated. By the procedure less than 1.2 ${\mu}g$. of phosphate-phosphorus can be determined with an accuracy of less than 5% the relative error. The molybdenum(Ⅵ) extracted by the above procedure is reduced to molybdenum(V) in the extract directly with a solution of 4 to 10% of stannous chloride, 0.5 to 1.5 mM of copper, and 0.1 to 0.9 N of perchloric acid as final concentration in 4.3 to 6.3 N of hydrochloric acid or 9.0 to 13.0 N of sulfuric acid by heating for one minute in boiling water, after cooling, the molybdenum(V)-thiocyanate complex color is developed by adding 6.0 M ammonium thiocyanate solution making the final concentration to be in a range of 0.4 to 0.9 M. This procedure the very sensitive, reliable, and stable can be applied to determining submicrogram amounts of phosphate in natural waters with a precision of 1.6 ${\times}\;10^{-2}$ the standard deviation as absorbance.

  • PDF

Study of Pulse Generation Technique for Serial dual Electrode Detection of Amino Acids and Proteins in Flow Injection Analysis

  • Fung, Ying-Sing;Mo, Song-Ying
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.575-582
    • /
    • 1995
  • A new analytical procedure using a serial dual electrode detector was developed for the analysis of amino acids and proteins. Bromine was generated at the upstream electrode and detected by the downstream electrode. The presence of amino acids and proteins was shown to lower the downstream current but with no apparent effect on the upstream current. This indirect mode of detection can be applied to the determination of amino acids and proteins which are electrochemically inactive or too large to be accessible to the electrode surface for electron exchange. The method is shown capable to determine various amino acids (cystine, tyrosine, lysine, tryptophan, glycine, methionine and arginine) and proteins (cytochrome c, hemoglobin, HAS, a-Amylase, Conalbumin I, Catalase and Myglobin) with linear working range for amino acids between $10^{-6}$ to $10^{-3}M$ and total proteins between $10^{-7}$ to $10^{-3}M$. The method has been applied for the analysis of amino acids and total protein in food using Flow Injection Analysis with results obtained comparable to those using the traditional analytical procedure. Use of pulse generation technique was shown to produce a more stable flow injection analysis peaks for repetitive determination than the use of conventional constant current method which showed increase of the background current after determination over 200 minutes. The pulse method was found to give stable baseline even after 400 minutes. Thus, the method is shown able to provide a suitable analytical procedure for automatic analysis of amino acids and proteins in food by flow injection analysis.

  • PDF

Sinus floor augmentation at the time of tooth removal (상악 구치부의 발치와 동시에 시행하는 상악동저 증강술을 이용한 임프란트 증례)

  • Kim, Min-Kue;Jin, Min-Ju;Ahn, Eun-Joo
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.647-653
    • /
    • 2007
  • Rapid crestal bone resorption following maxillary tooth loss is further accentuated in the posterior regions because of pneumatization and enlargement of the maxillary sinuses. A treatment rationale that allows preservation and augmentation of vertical available bone at the time of posterior maxil-lary tooth extraction may offer numerous therapeutic benefits which are more short courses of ther-apy and no needs of additional surgical augmentation. The present study comprised 3 patients who had 4 posterior maxillary teeth with no evident bone between the tooth apex and sinus floor, as estimated through preoperative radiographic analysis. Sinus floor augmentation at the time of tooth extraction was chosen for the ltreatment of these patients. After the tooth was carefully extracted, the empty alveolus was thoroughly debrided and a trephine approach was performed. Particulated autogenous bone was gently pushed beyond the empty alveolus to elevate the sinus membrane using an osteotome. The distance between bone crest and si-nus floor was radiographically estimated 4 months after the first procedure. Another procedure was then carried out to place the implants of 11 mm length without another augmentation procedure. All implant were clinically stable, with no sign of infection. The presented surgical procedure performed at the time of extraction of posterior maxillary teeth in close proximity to the sinus floor allowed placement of implants of proper length.

Bone-added osteotome sinus floor elevation with simultaneous placement of non-submerged sand blasted with large grit and acid etched implants: a 5-year radiographic evaluation

  • Jung, Jee-Hee;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.2
    • /
    • pp.69-75
    • /
    • 2010
  • Purpose: Implant survival rates using a bone-added osteotome sinus floor elevation (BAOSFE) procedure with simultaneous placement of a non-submerged sand blasted with large grit and acid etched (SLA) implant are well documented at sites where native bone height is less than 5 mm. This study evaluated the clinical results of non-submerged SLA Straumann implants placed at the time of the BAOSFE procedure at sites where native bone height was less than 4 mm. Changes in graft height after the BAOSFE procedure were also assessed using radiographs for 5 years after the implant procedure. Methods: The BAOSFE procedure was performed on 4 patients with atrophic posterior maxillas with simultaneous placement of 7 non-submerged SLA implants. At least 7 standardized radiographs were obtained from each patient as follows: before surgery, immediately after implant placement, 6 months after surgery, every year for the next 3 years, and after more than 5 years had passed. Clinical and radiographic examinations were performed at every visit. Radiographic changes in graft height were calculated with respect to the implant's known length and the original sinus height. Results : All implants were stable functionally, as well as clinically and radiographically, during the follow-up. Most of the radiographic reduction in the grafted bone height occurred in the first 2 years; reduction after 2 years was slight. Conclusions: The simultaneous placement of non-submerged SLA implants using the BAOSFE procedure is a feasible treatment option for patients with severe atrophic posterior maxillas. However, the grafted bone height is reduced during the healing period, and patients must be selected with care.

A Fuzzy Model Based Controller for the Control of Inverted Pendulum

  • Wook Chang;Kwon, Ok-Kook;Joo, Young-Hoon;Park, Jin-Bae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.459-464
    • /
    • 1998
  • In this paper, we propose a stable fuzzy logic controller architecture for inverted pendulum,. In the design procedure, we represent the fuzzy system as a Takagi-Sugeno fuzzy model and construct a global fuzzy logic controller by considering each local state feedback controller and a supervisory controller, Unlike usual parallel distributed controller, one can design a global stable fuzzy controller without finding a common Lyapunov function by the proposed method. A simulation is performed to control the inverted pendulum to show the effectiveness and feasibility of the proposed fuzzy controller.

  • PDF

Development of a Flow Compensating Boom Sprayer for the Speed Variation (주행속도 보상형 붐방제기의 개발)

  • 구영모;정재은
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.211-218
    • /
    • 1998
  • A variable flow-controlled boom sprayer was developed and evaluated. Field tests were conducted to evaluate the adoptability of the sprayerr with optimal conditions. Negative response time was obtained from the field test because pump and PTO were interlocked with the speed of sprayer. Another reason for the negative value was due to the definition of the response time. With constant on-time control, the system was unstable at the conditions of small tolerance and long control interval. The performances of the spray system were stable and accurate. The stable and synchronous responses were achieved with a variable on-time control. The flow control system with an optimal condition (1.0 sec of control interval, 2 of damping ratio, 1% of tolerance) provided the proper performance for uniform spraying. A standard operating procedure of the flow compensating boom sprayer for the ground speed variation was presented and recommended.

  • PDF

The Effect of the Sn Amounts on the Microstructure of Rapidly Solidified Ag-Sn-In Alloys (급속응고한 Ag-Sn-In 미세조직에 미치는 Sn 함량 변화의 영향)

  • Cho, Dae-Hyoung;Kwon, Gi-Bong;Nam, Tae-Woon
    • Journal of Korea Foundry Society
    • /
    • v.26 no.2
    • /
    • pp.92-97
    • /
    • 2006
  • Contact material is widely used as electrical parts. Ag-Cd alloy has a good wear resistance and stable contact resistance. But the disadvantages of Ag-Cd alloy are coarse Cd oxides and harmful metal, Cd. To solve the disadvantages of that, Ag-Sn alloy that has stable and fine Sn oxide at high temperature has been developed. In order to optimize Sn amount that affects the formation of the oxide layer on the surface, we worked for the microstructures and properties of Ag-Sn material fabricated by rapid solidification process. The experimental procedure were melting using high frequency induction, melt spinning, and internal oxidation. We have shown that the optimized Sn amount for high hardness is 7.09 wt%Sn. Surface oxide layer forms when Sn amount is over 9.45 wt%. The size of Sn oxide is 20 nm.

Design and Test of Sequential CMOS Domino Logic Array (순서 CMOS Domino Logic Array의 설계 및 테스트)

  • Park, J.K.;Kim, Y.H.;Jung, J.M.;Han, S.B.;Lim, I.C.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1476-1480
    • /
    • 1987
  • This paper proposes a design method for SCLA(sequential CMOS Domino Logic Array) using 1-level CMOS Domino Logic and Stable Shift Register Latch. Also an algorithm to generate a test sequence and a test procedure for the SCLA are presented. The SCLA has advantages of low power consumption, high density and high speed, and performs hazard-and race-free logic operation, because of using SSRL(Stable Shift Register Latch). By using the proposed test method, all of stuck-at, cross-point, stuck-on and stuck-open faults in SCLA are detected by short test sequence.

  • PDF

A Hybrid Spatial Differencing Scheme for Discrete Ordinates Method in 2D Rectangular Enclosures (2차원 사각 밀폐 공간에서의 구분 종좌표법을 위한 하이브리드 공간 차분법)

  • Kim, Il-Kyoung;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.1
    • /
    • pp.104-113
    • /
    • 1999
  • A hybrid spatial differencing scheme for the discrete ordinates method is proposed to predict radiative heat transfer in two-dimensional rectangular enclosures. Since this scheme takes the advantages of the diamond scheme and step scheme and includes the characteristics of medium, more accurate and stable results can be obtained. In its development several spatial differencing schemes are examined to address the effect of numerical smearing (or false scattering). Predictions from the proposed hybrid scheme are compared to those of other schemes for transparent, purely absorbing, purely scattering, or absorbing-emitting-isotropically scattering media. It is found that the proposed scheme predicts stable and less smeared results than others.

Stability of the Robot Compliant Motion control - Part 1 : Theory

  • Kim, Sung-Kwun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.973-980
    • /
    • 1988
  • This two-part paper presents a control method that allows for stable interaction of a robot manipulator with the environment. In part 1, we focus on the input ouput relationships (unstructured modeling) of the robot and environment dynamics. This analysis leads to a general condition for stability of the robot and environment taken as a whole. This stability condition, for stable maneuver, prescribes a finite sensitivity for robot and environment where sensitivity of the robot(or the environment) is defined as a mapping forces into displacement. According to this stability condition, smaller sensitivity either in robot or in environment leads to narrower stability range. In the limit, when both systems have zero sensitivity, stability cannot be guaranteed. These models do not have any particular structure, yet they can model a wide variety of industrial and research robot manipulators and environment dynamic behavior. Although this approach of modeling may not lead to any design procedure, it will allow us to understand the fundamental issues in stability when a robot interacts with an environment.

  • PDF