• 제목/요약/키워드: Stability index

검색결과 1,251건 처리시간 0.034초

한정된 위치의 PMU 정보를 이용한 수도권 전압안정도 감시 알고리즘 (A Voltage Stability Monitoring Algorithm using a Few PMUs in Metropolitan Area)

  • 한상욱;이병준
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2328-2334
    • /
    • 2009
  • Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic voltage stability becomes one of achievements we can obtain from PMUs. It is very important to select the method appropriate to the KEPCO system since there are many voltage stability indices. In the paper, we propose an advanced WAVI (Wide Area Voltage Stability) for monitoring dynamic voltage stability. It reflects the PMU installation plan of KEPCO, thus it is suitable for KEPCO system specially. The salient features of the proposed index are; i) it uses only PMU measurements without coupling with EMS data. ii) it is computationally unburden so that it can be applied to real-time situation. The proposed index is applied to the KEPCO test system and the result shows that it successfully predicts voltage instability through the comparative studies.

엔진 윤활특성과 연비 상관성에 대한 연구 (Correlation between Lubrication Characteristics of Engine and Fuel Economy)

  • 오정준;차상엽;정도곤;이종주
    • Tribology and Lubricants
    • /
    • 제30권3호
    • /
    • pp.189-198
    • /
    • 2014
  • This paper presents the results of an experimental investigation of the correlation between the lubrication characteristics of an engine and its fuel economy. Improving the lubrication characteristics of the engine oil is one of the most efficient ways to improve a car's fuel economy. The methods to accomplish this include lowering the viscosity, adding a friction modifier and optimizing the shear stability index of a viscosity index improver. In addition, it is necessary to use different methods to reduce the friction to individual lubrication areas, because different lubrication regimes are used for different engine parts. The experimental investigation in this study is based on design of experiments ; this paper presents the results of a modified Sequence VID test, which is an ASTM standard test used to measure the effects of automotive engine oils on the fuel economy of passenger cars. The results demonstrate the effects of the following lubrication factors on the fuel economy : the low temperature cranking viscosity, high-temperature high shear (HTHS) viscosity, friction modifier, polymer type and shear stability index of the viscosity index improver. Moreover, this study involves an analysis of variance based on design of experiments. The test results show that the HTHS viscosity, friction modifier and shear stability index of the viscosity index improver are more effective than the other factors. Therefore, lowering the viscosity, adding a friction modifier and optimizing the shear stability index of a viscosity index improver should be considered to improve fuel economy.

나로우주센터 상공의 대기 안정도지수 및 뇌운관련 대류활동 특성 연구 (A Study on the Characteristics of Convective Activities related to Atmospheric Stability Index and Thunderstorms over the Naro Space Center)

  • 김홍일;최은호;서성규
    • 한국환경과학회지
    • /
    • 제28권12호
    • /
    • pp.1133-1145
    • /
    • 2019
  • Successful launch requires state-of-the-art launch vehicle technology and constant test operations, However, the meteorological threat to the launch vehicle flight trajectory is also an important factor for launch success. Atmospheric stability above the Naro Space Center at the this time is very important, especially because the initial flight operation can determine the success of the launch. Moreover, during the flight of launch vehicle with rapid pressure and thrust into the atmosphere, convection activity in the atmosphere may create environmental conditions that cause severe weather threats such as thunderstorms. Hence, studies of atmospheric instability characteristics over the Naro Space Center are a necessary part of successful launch missions. Therefore, the main aims of this study were to (1) verify the atmospheric stability index and convection activity characteristics over the Naro Space Center using radiosonde data observed from 2007 to 2018 by the Naro Space Center, (2) analyze changes in the atmospheric stability index according to monthly and seasonal changes, and (3) assess how the calculated atmospheric stability index is related to actual thunderstorm occurrence using statistical analysis. Additionally, we aimed to investigate the atmospheric characteristics above the Naro Space Center through the distribution chart of the atmospheric stability index during summer, when convection activity is highest. Finally, we assessed the relationship between lightning occurrence and unstable atmospheric conditions, through predictability analysis performed using the lightning observation data of the Korea Meteorological Administration.

A Novel Line Stability Index for Voltage Stability Analysis and Contingency Ranking in Power System Using Fuzzy Based Load Flow

  • Kanimozhi, R.;Selvi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.694-703
    • /
    • 2013
  • In electric power system, the line stability indices adopted in most of the instances laid stress on variation of reactive power than real power variation of the transmission line. In this paper, a proposal is made with the formulation of a New Voltage Stability Index (NVSI) which originates from the equation of a two bus network, neglecting the resistance of transmission line, resulting in appreciable variations in both real and reactive loading. The efficacy of the index and fuzzy based load flow are validated with IEEE 30 bus and Tamil Nadu Electricity Board (TNEB) 69 bus system, a practical system in India. The results could prove that the identification of weak bus and critical line in both systems is effectively done. The weak area of the practical system and the contingency ranking with overloading either line or generator outages are found by conducting contingency analysis using NVSI.

Guaranteed Stability Margins of the Discrete-Time LQ Optimal Regulator for a Performance Index with Cross-Product Terms

  • Fang, Tae-Hyun;Park, Jae-Weon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.107.4-107
    • /
    • 2001
  • In this paper, the guaranteed stability margins of LQ optimal regulators for a performance index with cross-product terms are suggested in the discrete-time case. An example for the LQ optimal regulator of an inverted pendulum system is given to demonstrate the validity of the suggested stability margins.

  • PDF

가격함수에 교차곱항이 포함된 이산시간 LQR의 안정성 여유 (Stability Margin of Discrete-Time LQR with Cross-Product Term in Performance Index)

  • 최재원;황태현
    • 제어로봇시스템학회논문지
    • /
    • 제8권10호
    • /
    • pp.856-860
    • /
    • 2002
  • The guaranteed stability margin of LQ optimal regulators with cross-product terms in a performance index is derived for the discrete-time case. In order to obtain the guaranteed stability margin, the singular value of the return difference matrix is examined. A numerical simulation is provided to demonstrate the validity of the derived stability margin.

부하모델을 고려한 전압 안정도 평가지표개발과 시스템 안정도 연구 (A Study on Developing Voltage Stability Index arid System Stability by Incorporating Dynamic Load Modeling)

  • 위원석;함정필;추진부;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.187-189
    • /
    • 1999
  • Accurate load models allow more precise calculations of power system stability, This paper presents new static voltage stability index considering the load models. Also, We apply the load models for the existent voltage stability indices, and evaluate them.

  • PDF

손실감도지표의 전력계통 적용 (Applications of System Loss Sensitivity Index to Power Systems)

  • 이상중
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권2호
    • /
    • pp.56-61
    • /
    • 2000
  • In the paper, the system loss sensitivity index that implies the incremental system loss with respect to the change of bus power is derived using optimization technique. The index λ reaches $\infty$ at critical loading point and can be applied to actual power systems for following purposes. 1) Evaluation of system voltage stability 2)Optimal investment of reactive power focused on minimizing system loss and maximizing system voltage stability 3)Optimal re-location of reactive power focused on minimizing system loss and maximizing system voltage stability 4)Optimal load shedding in case of severe system contingency focused on minimizing system loss and maximizing system voltage stability. Case studies for each application have proved their effectiveness.

  • PDF

부하 모델을 고려한 전압 안정도 측면에서의 무효전력 보상량 결정에 관한 연구 (A Study on Reactive Power Compensation against Voltage Collapse Considering Load Model)

  • 함정필;김정훈;이병하;원종률
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.168-170
    • /
    • 2001
  • This paper presents the strategy of reactive power compensation which directly improves voltage stability. Voltage stability index that serves as an indirect assessment of voltage stability margin is derived from M.G.C.F. (Modified Generalized Curve Fit) algorithm incorporating load model. Weak buses are ranked by this stability index, and amounts of reactive power compensation are determined by function of reactive power and stability index. Using the proposed strategy, all load buses can be prevented from voltage collapse gradually. A simple illustrative example is given as well as simulation results obtained on 5 bus test system and 19 bus real power system.

  • PDF