• 제목/요약/키워드: Stability Analysis Method

검색결과 3,773건 처리시간 0.036초

혼합형 전압안정도 해석 (Hybrid Voltage Stability Analysis)

  • 김원겸;김건중;주운표;이상중
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권2호
    • /
    • pp.43-49
    • /
    • 2000
  • It is a complex process to analyze power system voltage stability problems with all of the dynamics of a system, because a large power network system sophisticatedly consists of generators, lines, loads and so forth. So we considered the dynamics of loads so as to analyze voltage stability method- by carrying out an analysis of steady state voltage stability and dynamic voltage stability simultaneously. To perform a steady state voltage stability program in advance makes it possible to cut down on laborious calculations so that an analysis of dynamic voltage stability becomes concise. The validity and efficiency of the method presented in this paper were verified by applying the IEEE 14 bus system.

  • PDF

Comparison of Small Signal Stability Analysis Methods in Complex Systems with Switching Elements

  • Kim, Deok Young;Meliiopoulos, A.P.Sakis
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권2호
    • /
    • pp.79-83
    • /
    • 2004
  • A new small signal stability analysis method for eigenvalue analysis is presented. This method utilizes the Resistive Companion Form (RCF) for the computation of the transition matrix over a specified time interval, which corresponds to a single cycle operation of the system. This method is applicable to any system, with or without switching element. An illustrative example of the method is presented and the eigenvalues are compared with those of the conventional state space method (analog) in order to demonstrate the accuracy of the proposed eigenvalue analysis method. Also, the variations of oscillation modes that are caused by the switching operation can be precisely analyzed using this method.

교류-직류 연계계통에 있어서 직류제어방식의 비교연구 (A study on comparative analysis of direct current control in A.C.-D.C. interconnected power system)

  • 정형환;왕용필;안병철;이광우
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.474-483
    • /
    • 1996
  • In this paper, as a part of the method improving stability, the load-flow calculation in D.C. power system and the models for stability analysis are studied with A.C-D.C. interconnected power systems transmission performed. Moreover, the theory is established in relation to each control method of D.C. power systems. Then the stability of A.C-D.C.interconnected power systems is compared and considered by the way of dividing the operating control method of the rectifier inverter converter into ACR-AVR, APR-A.gamma.R, A.alpha.R-ACR. The dynamics characteristic of terminal voltage, frequency, active-reactive power and rotor angle of the generator with disturbances and load fluctuations is considered. In addition, the characteristic of direct voltage, direct current, power and control systems. From this the comparative analysis of the direct current control method, the possibility of the stability analysis of A.C.-D.C. interconnected power system is considered. (author). refs., figs., tabs.

  • PDF

Stability Analysis of Grid-Connected Inverters with an LCL Filter Considering Grid Impedance

  • Li, Xiao-Qiang;Wu, Xiao-Jie;Geng, Yi-Wen;Zhang, Qi
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.896-908
    • /
    • 2013
  • Under high grid impedance conditions, it is difficult to guarantee the stability of grid-connected inverters with an LCL filter designed based on ideal grid conditions. In this paper, the theoretical basis for output impedance calculation is introduced. Based on the small-signal model, the d-d channel closed-loop output impedance models adopting the converter-side current control method and the grid-side current control method are derived, respectively. Specifically, this paper shows how to simplify the stability analysis which is usually complemented based on the generalized Nyquist stability criterion (GNC). The stability of each current-controlled grid-connected system is analyzed via the proposed simplified method. Moreover, the influence of the LCL parameters on the stability margin of grid-connected inverter controlled with converter-side current is studied. It is shown that the stability of grid-connected systems is fully determined by the d-d channel output admittance of the grid-connected inverter and the inductive component of the grid impedance. Experimental results validate the proposed theoretical stability analysis.

계통안정화를 위한 SMES의 모델링과 적정위치 선정 (A Modeling and Optimal Site of SMES for Power System Stabilization)

  • 김정훈;임재윤;이종필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.494-501
    • /
    • 1999
  • In this research, ANN modeling method of SMES unit is developed for stability analysis, and the optimal site is selected to maximize stabilization effect of SMES unit. The ANN is trained by learning data which is obtained through the application of complex test function into the traditional mathematical mode. In order to verify the validity of proposed modeling method, fault data of sample power system is applied to both the traditional and the ANN models. When the response of traditional and proposed models are compared, the average error for the active and reactive power are 2.51[%], and 0.24[%], respectively. From the comparison, the relevance of proposed method is validated. For the transient stability analysis, an application method of the proposed model is presented, and the transient stability performance index, which describes system stabilization effect of SMES at disturbance, is also suggested, and optimal site selection method of SMES is presented. In the viewpoint of the voltage stability, system stabilization criterion of local bus is presented from P­V curve, and then optimal site which can maximize the voltage stabilization of the whole power system, is decided from the proposed voltage stability performance index.

  • PDF

3차원 Floquet 안정성 분석을 위한 가상 경계법의 적용 (APPLICATION OF AN IMMERSED BOUNDARY METHOD FOR THREE-DIMENSIONAL FLOQUET STABILITY ANALYSIS)

  • 윤동혁;양경수
    • 한국전산유체공학회지
    • /
    • 제14권4호
    • /
    • pp.41-47
    • /
    • 2009
  • An immersed boundary method(IBM, Kim et al.(2001)) for simulating flows over complex geometries is applied to computation of three-dimensional Floquet stability of a periodic wake. Floquet stability analysis is employed to extract different modes of three-dimensional instability. To verify the present method, a fully-resolved Floquet stability calculation for flow past a circular cylinder is considered. There are two different instability modes with long(mode A) and short (mode B) spanwise wavelengths for the periodic wake of a circular cylinder. The critical Reynolds number and the most unstable spanwise wavelengths of modes A and B are computed using the present method, and compared with other authors' results currently available.

불연속 동작특성을 갖는 전력계통의 RCF법을 사용한 고유치 해석 : 상태천이 방정식으로의 모델링 (Eigenvalue Analysis of Power Systems with Non-Continuous Operating Elements by the RCF Method : Modeling of the State Transition Equations)

  • 김덕영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권2호
    • /
    • pp.67-72
    • /
    • 2005
  • In conventional small signal stability analysis, system is assumed to be invariant and the state space equations are used to calculate the eigenvalues of state matrix. However, when a system contains switching elements such as FACTS devices, it becomes non-continuous system. In this case, a mathematically rigorous approach to system small signal stability analysis is by means of eigenvalue analysis of the system periodic transition matrix based on discrete system analysis method. In this paper, RCF(Resistive Companion Form) method is used to analyse small signal stability of a non-continuous system including switching elements. Applying the RCF method to the differential and integral equations of power system, generator, controllers and FACTS devices including switching elements should be modeled in the form of state transition equations. From this state transition matrix eigenvalues which are mapped to unit circle can be calculated.

RCF 해석법을 사용한 STATCOM의 진동모드 해석 (Analysis of Oscillation Modes of the STATCOM by the RCF Method)

  • 이윤호;김덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.228-229
    • /
    • 2006
  • The RCF analysis method is used to analyze small signal stability of power systems including GTO controlled FACTS equipment such as STATCOM. To apply the RCF analysis method in power system small signal stability problems, the state transition equations of power system equipments and power systems with STATCOM are presented. In eigenvalue analysis of power systems by the RCF analysis method, the STATCOM is modelled into the equivalents voltage source model and the PWM switching circuit model. As a result of simulation, the RCF analysis method is very powerful to calculate the oscillation modes exactly after the switching operations, and useful to analyze the small signal stability of power systems with periodically operated switching device such as the STATCOM.

  • PDF

풍력발전설비 및 HVDC가 도입된 제주도 계통에 대한 안정도 해석 (Stability Analysis of Jeju Power System with Wind Turbine Generators and HVDC)

  • 김도형;김재언
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1897-1904
    • /
    • 2008
  • In this paper, the method for effective stability analysis of Jeju power system in 2011 is proposed. The stability analysis of Jeju power system was carried out by using proposed method In case of Jeju power system with wind turbine generators or without wind turbine generators, including CSC HVDC or VSC HVDC. The steady-state stability is validated by SCR and ESCR, PV curve, QV curve. And the transient stability is analyzed by CCT(Critical Clearing Time). VSC HVDC has more advantages than CSV HVDC on the stability. Also, Jeju power system without wind turbine generators has more advantages than Jeju power system with Wind Turbine Generators on the stability.

손실재분배와 정적전압의존형 부하모델을 고려한 전압안정도 해석 (Voltage Stability Analysis considering Static Voltage Dependent Load Model and Loss Redistribution)

  • 김근성;채명석;신중린;임한석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.215-217
    • /
    • 1997
  • In many conventional analysis of voltage stability the effect of load characteristics is ignored. But in the real system the load is composed of various components. Therefore if the load composition could be modeled then it will plays an important role in the analysis of static voltage stability. And also, if the system loss generally imposed to slack bus in the conventional load flow calculation is redistributed to each generator the accuracy of static voltage stability analysis can be improved. This paper presents the effect of load composition in the analysis of system stability as well the loss redistribution algorithm. And this paper will compare the result of conventional method with that of the proposed method.

  • PDF