• Title/Summary/Keyword: St. Jude Medical 기계판막

Search Result 16, Processing Time 0.125 seconds

Thrombosis of a St. Jude Medical Cardiac Valve in the Mitral Position - case report - (St.Jude 기계판막에 의한 승모판대치술후 발생한 판막의 혈전증 1례)

  • 임종수
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.677-679
    • /
    • 1989
  • Recently, we have experienced a case of acute thrombotic obstruction of the St. Jude Medical cardiac valve in the mitral position of the Heart. We will discuss about the incidence, recognition and preventive measurement of the thrombotic St. Jude Medical valve with the review of literatures.

  • PDF

The Long-term Clinical Result of St. Jude Mechanical Valve Replacement (St. Jude 기계판막 치환술의 장기 임상성적)

  • 배윤숙;정성철;김우식;정승혁;유환국;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.321-328
    • /
    • 2003
  • Background: The St. Jude Medical prosthesis is one of the popularly used artificial prosthesis, therefore the National Medical Center reports the long-term clinical results of patients who underwent prosthetic valve replacement with St. Jude medical valve for 18 years. Material and Method: Between January, 1984 and June, 2002, a series of 163 consecutive patients who had Implanted St. Jude prosthesis at the National Medical Center were reviewed. Mean age was 42.9$\pm$15.1 years and male to female ratio was 69:94. The operative procedure comprised of 87 MVR, 30 AVR, 45 DVR, and 1 TVR. The reoperative procedure comprised of 21 MVR, 2 AVR, and 14 DVR. Follow-up rate was 96.9%, and cumulative follow-up was 823.8 patient-years. Result: Early mortality rate was 7.9% (13 patients), late mortality rate was 8.7% (13 patients) and late mortality due to valve related complication was 47% (7 patients). Actual survival rate at 10 and 18 years were 91.7$\pm$2.1% and 91.0$\pm$1.9%. Linearized Incidence was as follows: thromboembolism, 1.09%/ patient-year; anticoagulant related hemorrhage, 0.36%/patient-year; valve thrombosis, 0.24%/patient-year; paravalvular leakage, 0.12%/patient-year; and prosthetic bacterial endocarditis, 0.12%/patient-year linearized incidence of over all valve related complication was 1.94%/patient-year. Freedom from valve related complication at 10 and 18 years were 89.1$\pm$3.3% and 88.4$\pm$3.9%. Freedom from valve related death at 10 and 18 years were 95.1$\pm$1.2% and 95.1$\pm$1.0%. Valve related complication was related the age of patient, especially anticoagulant related hemorrhage was more common in patients over 60 years of age. Valve related complication, death were higher in DVR than AVR or MVR, and valve related death was higher in reoperation. There was no relationship between valve related complication or death and implant valve of size. Conclusion: The long-term clinical results of patients implanted with St. Jude Mechanical prosthesis was quite satisfactory with a low incidence of valve related complication and mortality.

Twenty-year Experience of Mitral Valve Replacement with the St. Jude Medical Mechanical Valve Prosthesis (St. Jude 기계 판막을 이용한 승모판막 치환술의 20년 장기성적)

  • Seo Yeon-Ho;Kim Kong-Soo;Jo Jung-Ku
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.527-533
    • /
    • 2006
  • Background: A retrospective study was conducted to analyze the results of St. Jude Medical mitral valve replacement at the Chonbuk National University Hospital since the initial implant in May 1984. Material and Method: Between May of 1984 and December of 1996, 95 patients underwent MVR with the St. Jude Medical mechanical valve prosthesis at Department of Medical Science of Chonbuk National University Hospital and follow-up ended in May of 2004. Result: Age ranged from 19 to 69 years. Follow-up (mean${\pm}$standard deviation) averaged $10.6{\pm}4.2\;year$. Thirty-day operative mortality was 4.2% (4/95). Nine late deaths have occurred and actuarial survival was $90.5{\pm}3.0%,\;87.9{\pm}3.4%\;and\;83.2{\pm}4.6%$ at 5, 10 and 20 years, respectively. Probability of freedom from valve-rotated death was $95.5{\pm}2.1%,\;94.3{\pm}2.4%\;and\;91.0{\pm}3.9%$ at 5, 10 and 20 years, respectively. Seven patients have sustained thromboembolic events (1,05%/patient-year). Fifteen patients had anticoagulation related hemorrhage (3.56%/patient-year). There was no structural valve deterioration. Probability of freedom from all complications was $82.0{\pm}3.9%,\;71.3{\pm}4.8%\;and\;42.4{\pm}10.5%$ at 5, 10 and 20 years, respectively. Conclusion: We confirm the effective and excellent durability of the St. Jude Medical prosthesis in the mitral position with a low event rate at long-term follow-up. It also demonstrates the commonly encountered practical difficulty of adjusting the anti-coagulation protocol in patients with prosthetic mitral valves.

Clinical Analysis of St. Jude Medical Prosthesis (St. Jude Medical 기계판막의 임상적 연구)

  • 최순호
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.171-181
    • /
    • 1991
  • Result of St. Jude Medical valve replacement are presented in 106 patients who underwent operation from January 1985 through July 1989. The patient were 52 males and 56 females. Total 136 of St. Jude Medical valves were implanted; 91 in mitral position, 45 in aortic position. The hospital mortality rate was 5.7%o[6 patients] and the late mortality rate was 2.0%[2 patients]. The causes of death were low cardiac output in 5, iatrogenic right ventricular rupture in 1, heart failure in 1, ventricular arrhythmia in l. And, the causes of valve related complication were anticoagulant related hemorrhage in 5 patients[0.03% /patient-year] and thromboembolism[0.01% /patient-year] in 2 patients. In conclusion, the performance of the St. Jude Medical valve compare most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF

Clinical Results of the St. Jude Medical Cardiac Valve (St. Jude 기계판막의 임상성적)

  • 장기경;윤후식
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.959-963
    • /
    • 1996
  • St. Jude Medical bileaflet valve was implanted in 42 patients from September, 1988, to July, 199)(mitral valve replacement in 25, aortic valve replacement in 11, multiple valve replacement in 6). Concomitant procedures were performed in 5 patients(11.9%). The early mortality was 4.8%(2 patients) and the late mortality was 9.5%(4 patients). The valve-related causes of late mortality were prosthetic valve endocarditis(threi), unknown(one). There was no instance of structural failure. Follow up was 100% complete, with 179.8 patient-years and a mean follow up of 54 months(from 1.5 to 84 months). The overall actuarial survival rates was 90$\pm$4.7% at 5 years. At 5 years, the acturarial freedom from valve failure was 90$\pm$4.7%, 89.7$\pm$4.5% from thromboembolism and 92.3 $\pm$4.2% from bacterial endocarditis, respectively.

  • PDF

Clinical Results of Mitral Valve Replacement with St. Jude Medical Valve (St. Jude Medical 판막에 의한 승모판치환술의 임상성적)

  • 장원채;신성현;나국주;김상형
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.247-254
    • /
    • 1998
  • A total of 172 cases of MVR using the St. Jude Medical valve was conducted in the period from August 1986 to May 1996. The hospital mortality rate was 3.5% (n=6) and the late mortality rate was 3.3% (n=5). According to the follow-up of 161 surviving patients, the average length of survival was 50.23$\pm$0.27 months. Three cases of prosthetic valve related complication deaths were identified. Two cases could be ascribed to left atrial thrombi and resulting cerebral infarction, and one case was prosthetic valve endocarditis. Two cases were caused by hemorrhagic complications that we presume to have been accompanied by anti-coagulation therapy. The actuarial survival rate of all cases at 10 years was 92.3%. We conclude that good clinical results and a low complication rate could be achieved through mitral valve replacement with the St. Jude Medical valve. We also conclude that mid-term and long-term follow-ups were instrumental and necessary.

  • PDF

Long Term Results of Valve Replacement with the St. Jude Medical Heart Valves: Thirteen Year Experience (St. Jude 기계판막을 이용한 판막 치환술의 장기 성적)

  • Kim, Chang-Gon;Gu, Ja-Hong;Jo, Jung-Gu;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.891-898
    • /
    • 1997
  • Between May 1984 and January 1996, 130 patients were replaced cardiac valve using 150 St. Jude Medical prosthetic valves(42 aortic, 68 mitral, 20 aortic and mitral valve replycements). Follow-up was 97.6% complete. The early mortality rate was 5.4%, and late mortality rate was 4.9%. The valve-related late mortality rate was 3.3%. Of late complications, there were 6 anticoagulant related hemorrhages, 4 thromboembolisms and 1 paravalvular leakage. Linearized rates of late complication and valve-related late mortality were as follows: total late complications, .1.68o per patient-year: anticoagulant related hemorrhages, 0.92% per patient-year: thromboembolism, 0.61% per patient-year: paravalvular leakage, 0.15% per patient-year: reoperation, 0.15% per patient-year: and valve-related late mortalities, 0.61% per patient-year. Actuar al event free rate at 10 years was 87.4 $\pm$ 3.2%. The overall actuarial survival rate was 90.4$\pm$2.7% at 5 years, 87.5$\pm$3.3% at 10 years. Ninety eight percent of the survivors were in the New York Heart Association functional class I or II at the end of follow-up. There was significant improvement of cardiothoracic ratio. In conclusion, this study suggests the excellent durability of the St. Jude Medical Heart valve and remarkable functional benefit for the majority of the patients. However, prosthesisrelated complications are still common. Outcome is strongly related to the patient's preoperative cardiac condition and to the adequacy of anticoagulation control.

  • PDF

Clinical Evaluation of St.Jude Medical Valve Replacement (St.Jude 기계판막을 이용한 인공심장판막 치환의 외과적 고찰)

  • Jin, Ung;Rha, Suk-Joo;Cho, Kyu-Do;Kim, Chi-Kyung;Jo, Keon-Hyon;Wang, Young-Pil;Lee, Sun-Hee;Kwak, Moon-Sub;Kim, Se-Wha;Lee, Hong-Kyun
    • Journal of Chest Surgery
    • /
    • v.27 no.4
    • /
    • pp.272-280
    • /
    • 1994
  • Total 400 St.Jude Medical Bileaflet Valves were implanted in 336 pts from January 1983 to June 1993; 64 were aortic, 205 were mitral, 64 were double valve and 3 were tricuspid position. The follow up period extended from 6 months to 10 years[mean 24.3 months]. Male to female ratio was 1:1.7. There were total 27 deaths[cardiac related 20, cardiac non-related 7]. Overall mortality was 2.9%/pt-yr. There were 10 early deaths[3.0%] and 10 late cardiac related deaths [3.0%]. Prosthetic valve related complications occurred in 19 patients[5.7%] and among them, seven died; four died of thromboembolic events, two died of anticoagulants therapy related hemorrhagic complications and one died of bacterial endocarditis. NYHA class improved significantly especially in aortic valve replacement and double valve replacement. In AVR cases, the mean NYHA was 2.8 preoperatively and 1.3 postoperatively. And in DVR cases, 3.3 preoperatively and 2.2 postoperatively. The decision to employ a particular prosthesis was made according to the anticipated or known complications of the valve. The St.Jude Medical Valve retains all the hazards of other mechanical valves, most notably, thromboembolism. But the hemodynamic performance of St.Jude Medical Valve compared most favorably with other substitute valves in many reports. 0ur experience didn`t show any differences compared other authors in terms of valve related complication. So we concluded St. Jude Medical Valve can be primarily considered in the selection of artificial valve except in the patients when the usage of anticoagulant therapy is contraindicated.

  • PDF

Short-term and Intermediate-term Follow-up After Valve Replacement with the St.Jude Medical Prosthesis (St. Jude 기계판막의 단기및 중기 성적)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.57-65
    • /
    • 1992
  • St.Jude Medical cardiac valve replacement was performed in 322 patients: 191 had mitral, 58 had aortic, 72 had double valve and 3 had tricuspid valve replacement. Motality rate in early period was 2.8%[9 patients]. The most common cause of early death was low cardic output syndrome. Follow up extended from 1 to 90 months[mean: 34 months] in 292 patients among 313 in all surviving patients [93.6%]. There were thrombolic complications in eighteen patients. The probability of free from thromboembolism at 5 yerars in MVR, AVR and DVR were 84.7%, 91.8% and 90.2% respectively. And also, actuarial event free rate at 5 years in MVR, AVR and DVR were 80.1%, 82.2%, and 81.4% respectively. There were fourteen late death during follow up period: six from thromboembolism, one from hemorrhage and the others from non valve related -or unknown complications. The acturial survival rate at 5 years were 93.1% in mitral, 92.1% in aortic and 97.1% in double valve replacement. In conclusion, the performance of the St. Jude Mecanical valve compares most favorably with other artificial valves. But it remains still hazards of mechanical prosthesis such as thromboembolism and anticoagulant related hemorrhage.

  • PDF

Physical Analysis of the Prosthetic Valve Sound (기계판막치환후의 판막음에 대한 연구)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.589-593
    • /
    • 1989
  • The frequency spectrum of the metallic closing sound and its loudness were measured by non invasive techniques in 66 patients. They had examined a total of 7 Carbomedics valve, 10 Duromedics valve, 11 St. Jude heart valve in mitral position and 8 Carbomedics, 10 Duromedics, 20 St. Jude heart valve prostheses functioning normally in aortic position. Statistical comparison of the loudness from sound produced by the three valves in each position, the following; The Carbomedics valve has the lowest average loudness, followed by the St. Jude medical valve, and finally the Edward Duromedics valve. And we analysis the changing factor of the loudness of valve sound, only the velocity of the flow through the valve influenced to the valve sound.

  • PDF