• Title/Summary/Keyword: Square-waveform

Search Result 85, Processing Time 0.028 seconds

Optical Characterization of DBR Porous Silicon by Changing of Applied Current Density (전류세기의 변화에 따른 DBR 다공성 실리콘의 광학적 특성)

  • Choi, Tae-Eun;Park, Jaehyun
    • Journal of Integrative Natural Science
    • /
    • v.2 no.2
    • /
    • pp.82-85
    • /
    • 2009
  • Distributed Bragg reflector (DBR) porous silicon (PSi) was generated by an electrochemical etching a bragg structure into a silicon wafer through electrode current in aqueous ethanolic HF solution. DBR PSi exhibiting unique reflectivity was successfully obtained by an electrochemical etching of silicon wafer using square current waveform. The multilayered photonic crystals of DBR PSi exhibited the reflection of a specific wavelength with high reflectivity in the optical reflectivity spectrum. In this work, we have developed a method to create refractive index in Si substrate through intensity of an electric current. The electrochemical process allows for precise control of the structural properties of DBR PSi such as thickness of the porous layer, porosity, and average pore diameter. The number of reflection peak of DBR PSi and its pore size increased as the intensity of electric current increased. This might be a demonstration for the fabrication of specific reflectors or filters.

  • PDF

Igniter design methods of the ballasts for Ceramic Metal Halide lamp (세라믹 메탈할라이드 램프용 안정기의 점화기 설계 방법)

  • Park, Chong-Yeun;Choe, Wang-Seop
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.75-81
    • /
    • 2010
  • We described the operating principles of two different type of igniters for lightning of Ceramic Metal Halide Lamp(CMHL) and also provide some useful comparisons. One is for magnetic ballast, the other one is for electronic ballast which operates lamp by low-frequency square-waveform. Ignition voltage of lamp depends on the structure of igniter, such as the length and electrical characteristics of cable, which make troubles for ignition in real sites. Therefore, we measured and analyzed ignition voltages from igniters which are used in magnetic and electronic ballast in cables at a distance of 5 meters between a lamp and a igniter to suggests an applicable solution in real sites.

  • PDF

The Consideration for the Loss Characteristics accompanied by Variation of Inverter waveform in Induction Motor (인버터 파형 변화에 따른 유도전동기의 손실 특성 고찰)

  • Baek, Soo-Hyun;Youn, Shin-Yong;Kim, Seong-Cheol;Kim, Pill-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.174-176
    • /
    • 1995
  • An additional consideration for using general Induction Motor are about copper loss by harmonic component of source, and increase of iron loss due to switching frequency in semiconductor devices, so that these losses come to be significant elements on design for motors used for variable V/F. In this paper, therefore, the effects of the losses are discussed, in the case the source is generated by square wave and PWM Inverter.

  • PDF

Analysis on Electromyogram(EMG) Signals by Body Parts for G-induced Loss of Consciousness(G-LOC) Prediction (G-induced Loss of Consciousness(G-LOC) 예측을 위한 신체 부위별 Electromyogram(EMG) 신호 분석)

  • Kim, Sungho;Kim, Dongsoo;Cho, Taehwan;Lee, Yongkyun;Choi, Booyong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.119-128
    • /
    • 2017
  • G-induced Loss of Consciousness(G-LOC) can be predicted by measuring Electromyogram(EMG) signals. Existing studies have mainly focused on specific body parts and lacked of consideration with quantitative EMG indices. The purpose of this study is to analyze the indices of EMG signals by human body parts for monitoring G-LOC condition. The data of seven EMG features such as Root Mean Square(RMS), Integrated Absolute Value(IAV), and Mean Absolute Value(MAV) for reflecting muscle contraction and Slope Sign Changes(SSC), Waveform Length (WL), Zero Crossing(ZC), and Median Frequency(MF) for representing muscle contraction and fatigue was retrieved from high G-training on a human centrifuge simulator. A total of 19 trainees out of 47 trainees of the Korean Air Force fell into G-LOC condition during the training in attaching EMG sensor to three body parts(neck, abdomen, calf). IAV, MAV, WL, and ZC under condition after G-LOC were decreased by 17 %, 17 %, 18 %, and 4 % comparing to those under condition before G-LOC respectively. Also, RMS, IAV, MAV, and WL in neck part under condition after G-LOC were higher than those under condition before G-LOC; while, those in abdomen and calf part lower. This study suggest that measurement of IAV and WL by attaching EMG sensor to calf part may be optimal for predicting G-LOC.

Simulation Model of Harmonics Injection Sensorless Technique for Permanent Magnet Synchronous Motor (영구자석 동기 전동기의 고조파 주입 센서리스 기법 시뮬레이션 모델)

  • Yoon, Jin-Woo;Lee, Dong-Myung
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.67-71
    • /
    • 2020
  • In this study, a simulation model of the harmonic injection sensorless control technique is proposed. This model is suitable for the sensorless technique of low-speed area operation of motors. The motor of this model is permanent magnet motor. For sensorless control, 1kHz square wave is injected. The change in motor constant according to rotor position is realized by having different d-q inductance values. Sensorless techniques is implemented through functions of Simulink and models provided by Simulink libraries. It is shown that the harmonic component contained in the current is extracted using a filter, and the angle of the permanent magnet of the motor is detected using the extracted waveform. The validity of the simulation model is demonstrated through the estimated motor angle waveform and the related waveforms of the motor control applied to the 1kW permanent magnet motor.

Nonlinear Speech Enhancement Method for Reducing the Amount of Speech Distortion According to Speech Statistics Model (음성 통계 모형에 따른 음성 왜곡량 감소를 위한 비선형 음성강조법)

  • Choi, Jae-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.465-470
    • /
    • 2021
  • A robust speech recognition technology is required that does not degrade the performance of speech recognition and the quality of the speech when speech recognition is performed in an actual environment of the speech mixed with noise. With the development of such speech recognition technology, it is necessary to develop an application that achieves stable and high speech recognition rate even in a noisy environment similar to the human speech spectrum. Therefore, this paper proposes a speech enhancement algorithm that processes a noise suppression based on the MMSA-STSA estimation algorithm, which is a short-time spectral amplitude method based on the error of the least mean square. This algorithm is an effective nonlinear speech enhancement algorithm based on a single channel input and has high noise suppression performance. Moreover this algorithm is a technique that reduces the amount of distortion of the speech based on the statistical model of the speech. In this experiment, in order to verify the effectiveness of the MMSA-STSA estimation algorithm, the effectiveness of the proposed algorithm is verified by comparing the input speech waveform and the output speech waveform.

Design and Implementation K-Band EWRG Transceiver for High-Resolution Rainfall Observation (고해상도 강수 관측을 위한 K-대역 전파강수계 송수신기 설계 및 구현)

  • Choi, Jeong-Ho;Lim, Sang-Hun;Park, Hyeong-Sam;Lee, Bae-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.5
    • /
    • pp.646-654
    • /
    • 2020
  • This paper is to develop an electromagnetic wave-based sensor that can measure the spatial distribution of precipitation, and to a electromagnetic wave rain gauge (hereinafter, "EWRG") capable of simultaneously measuring rainfall, snowfall, and wind field, which are the core of heavy rain observation. Through this study, the LFM transmission and reception signals were theoretically analyzed. In addition, In order to develop a radar transceiver, LFM transceiver design and simulation were conducted. In this paper, we developed a K-BAND pulse-driven 6W SSPA(Solid State Power Amplifiers) transceiver using a small HMIC(Hybrid Microwave Integrated Circuit). It has more than 6W of output power and less than 5dB of receiving NF(Noise Figure) with short duty of 1% in high temperature environment of 65 degrees. The manufactured module emits LFM and Square Pulse waveform with the built-in waveform generator, and the receiver has more than 40dB of gain. The transceiver developed in this paper can be applied to the other small weather radar.

A New Driving Method Generating Self-Erasing Discharge to Improve Luminous Efficiency in AC PDP (AC PDP에서 휘도효율을 향상시키기 위하여 자기소거 방전을 발생시키는 새로운 구동방법)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.168-172
    • /
    • 2014
  • A new sustain driving method is proposed to improve luminous efficiency by the generation of the self-erasing discharge during a sustain period in AC plasma display panel. As one subfield time in the conventional AC PDP is divided into the reset, address, and sustain period. Among them, as the square sustain waveform is alternately applied to the X and Y electrodes on the front plate during the sustain period, the plasma discharge for displaying the image is continuously produced. Meanwhile, in the conventional driving method, the address waveform applied to the A electrode on the rear plate is only driving during an address period and grounded during a sustain period. In this experiment, the negative pulse is applied to the A electrode at the latter part of the sustain pulse for improving the luminous efficiency producing the self-erasing discharge during the sustain period. The negative pulse on the A electrode can change from the space to the wall charge and induce the additional discharge by the accumulated wall charge when the voltages of three electrodes are grounded. As a result, the luminous efficiency will be measured with changes in the voltage level of the A electrode and the new driving method can be improved to the luminous efficiency about 32 % compared with the conventional driving method.

Sensorless Operation of Low-cost Inverters through Square-wave High Frequency Voltage Injection (사각 고주파 주입을 통한 저가형 인버터의 센서리스 운전)

  • Hwang, Sang-Jin;Lee, Dong-Myung
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.95-103
    • /
    • 2022
  • In this paper, the efficiency of a sensorless method with square-wave injection for a low-cost inverter, so called B4 inverter is presented. This inverter comprises only 4 switches to reduce system cost. It is distinguished from the conventional B6 inverter that has 6 of switching elements. The B4 inverter, injected a 1 kHz of harmonic wave, has been modelled using the functions and library in Matlab/Simulink. This paper described each component of sensorless algorithm. Among them, the Notch Filter is used to extract the harmonic component of the phase current and a second-order low-pass filter was used to reduce the ripple of the estimated speed. It is shown through simulation that the rotor angle of a permanent magnet synchronous motor is detected by multiplying the current waveform extracted using the notch filter by the harmonic voltage. The feasibility of the proposed method is shown through Simulink simulation.

Influence of reset pulse form on electrical characteristics in AC-PDP

  • Cho, T.S.;Ko, J.J.;Lee, C.W.;Cho, G.S.;Choi, E.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.159-161
    • /
    • 2000
  • After the square type reset pulse, the condition of remaining wall charge has been experimentally investigated in AC-PDP with VDS (Versatile Driving Simulator) system, in which arbitrary driving waveform and sequence can be used. After the self-discharge process, almost wall charges are eliminated. But some wall charges are not and its quantity is dependent on the voltage of the reset pulse. When the voltage of the reset pulse is growing, its quantity is decreased. But if the voltage of the reset pulse is above 300V, the wall voltage due to remaining wall charge is constant and its value is found out 6V. Also it is found that its polarity is always same with the one made by the reset pulse. It means that the polarity is not changed by the self-discharge.

  • PDF