• Title/Summary/Keyword: Square pulse

Search Result 259, Processing Time 0.023 seconds

Modulation and Pre-equalization Method to minimize time delay in Equalization Digital On-Channel Repeater (등화형 디지털 동일채널 중계기의 시간지연을 최소화하기 위한 변조 및 전치등화 방법)

  • Park Sung-Ik;Kim Heung-Mook;Seo Jae-Hyun;Eum Ho-Min;Lee Yong-Tae;Lee Jae-Young;Lee Soo-In
    • Journal of Broadcast Engineering
    • /
    • v.11 no.2 s.31
    • /
    • pp.229-241
    • /
    • 2006
  • In this paper we propose and analyze a novel modulation and pre-equalization method to minimize signal processing time delay for the Equalization Digital On-Channel Repeater (EDOCR) in ATSC (Advanced Television Systems Committee) terrestrial digital TV system. The proposed modulation method uses Equi-Ripple (ER) filter coefficients instead of conventional Square Root Raised Cosine (SRRC) after coefficients for VSB (Vestigial Side Bands) pulse shaping. And the proposed pre-equalization method calculates pre-equalizer filter coefficients by using baseband signal as reference signal and demodulated repeater output signal, then generates a new VSB pulse shaping filter coefficients by convolutioning ER filter coefficients and pre-equalizer filter coefficients. The newly generated pulse shaping filter does not have minimized time delay by adjusting the number of pre-taps of the filter, but also compensates linear distortions caused by ER filter and mask filter.

Transient Impedance Characteristics of Grounding Rods (봉상접지극의 과도임피던스 특성)

  • 김일권;송재용;길경석;권장우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.133-143
    • /
    • 2001
  • This paper describes the correlation of the transient impedance and its parameters with the stationary resistance of a grounding system to a square pulse current and a lightning impulse current. In the experiment, the grounding system consists of a single grounding rod$(\Psi10[mm], 1[m])$and/or a triple-grounding rods of equilateral triangles with 5[m] spacing for operation. To analyze the transient impedance characteristics of the grounding system, a pulse generator which can produce square wave of a 30[ns] rise-time and a $20[\mus] $pulse duration is designed and fabricated. The injected content in the grounding system and the developed potential were recorded, and the time variation of the transient impedance were calculated as the ratio of the potential rising to the injected current at each time. The transient impedance and the effective surge impedance Z3 which defines economic protection level in power system were quite higher than the stationary resistance. The grounding impedance is decreased by the application of the triple-rods grounding system, and its effect is decreased as the frequency of the current is increased due to the inductance of the grounding leads.

  • PDF

OUTAGE PROBABILITY ANALYSIS OF OC-CDMA SYSTEM WITH IMPERFECT POWER CONTROL UNDER DIFFERENT VELOCITY USERS

  • Panya, Muangruen;Junnapiya, Somyot;Techotchawan, Amnouy;Kidakorn, Pongjai;Omsin, Somchai
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.480-483
    • /
    • 2004
  • This paper, we present the evaluation of outage probability on the SNR under the overlapped carrier allocation scheme in the reverse link with imperfect power control of a cellular CDMA system, which is base on using Gaussian approximation. In numerical results, the band limited pulse generated by square-root of raised consin pulse shaping filters (SRRC) of the transmitted signal is investigated and compared in conventional FD/CDMA and OC-CDMA of the outage probability. It will be also show that the outage probability can be improved by overlapping of carriers. We use error statistics to model the intra-cell interference and evaluate the impact of different mobiles velocity and number of resolvable paths on the system performance.

  • PDF

Build-up Phenomenon and Self-Cleaning Effect upon Wire Electrode Surface of an Electrolytic Ozone Generator in Tap Water (수 분해형 오존발생장치의 전극선 비대현상과 자기회복 현상)

  • Moon, Jae-Duk;Kim, Yong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.626-629
    • /
    • 1991
  • The negative wire of an electrolytic ozone generator, proposed by authors, has been contaminated by attaching the impurity particulate in tap water, which is called BUILD-UP phenomenon. The higher applied voltage and the larger wire diameter have shown the higher build-up rate, which makes the current reducing largely and concurrently the ozone production smaller. It is found that the positive electrode of the ozone generator has a strong SELF-CLEANING effect by detaching the impurity particulate from its surface, which, however, is used us a novel means of solving the build-up problem. As a result, the build-up problem can be solved effectively by applying an alternate square wave pulse voltage to the electrodes so as to get the self-cleaning ability on the both electrodes during each of the half pulse duration time.

  • PDF

Square Pulse-Power Generation Using Capacitor Energy Source (캐패시터를 이용한 구형파 펄스전압발생 전원장치)

  • Rim, Geun-Hie;Choi, Young-Wook;Lee, Hong-Sik;Cho, Chu-Hyun;E.P., Pavlov
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1936-1938
    • /
    • 1997
  • Depending on the energy storage-element they are categorized into two types. One is called voltage-fed type when capacitors are used as energy storage elements. The other goes by the name of current-fed which s utilizes inductors as energy storage elements. This paper deals with the basic concept of pulse-power generation in the view points of load matching for the voltage-fed type.

  • PDF

Design of the High Frequency Resonant Inverter for Corona Surface Processes

  • Choi, Chul-Yong;Lee, Dae-Sik
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.119-122
    • /
    • 2005
  • A algorithm for control and performance of a pulse-density-modulated (PDM) series-resonant voltage source inverter developed for corona-dischange precesses is presented. The PDM inverter produces either a square-wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant dc voltage and operating frequency. Moreover it can achieve zero-current-switching (ZCS) and zero-voltage-switching (ZVS) in all the operating condition for a reduction of switching lost. Even though the corona discharge load with a strong nonlinear characteristics, new high frequency resonant inverter is shown the wide range power control from 5% to 100%.

  • PDF

Development of new Multifunction Voltage Recorder (다기능 디지털 전압기록장치 시스템 개발)

  • Shon, Su-Goog;Choi, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.693-696
    • /
    • 1999
  • This paper describes a new voltage recorder for the voltage management of a power distribution line by using a new voltage measurement technique. The RMS(Root Mean Square) voltage measurement for the power line under the assumption of a sinusoidal input voltage is taken by the full-wave rectifier, half-adder utilizing operational amplifier(OP) circuit. A/D converter utilizing a dual slope converter converts an analog voltage signal into a serial pulse. The pulse is counted with a single chip micro-controller, converted with the RMS voltage, and saved into a flash memory. In the last, a new voltage recorder with compact size and multifunction is developed. Also, Voltage Management System that can analyze the stored data via RS-232C cable is developed based on Windows 95 and Visual C++.

  • PDF

Prediction of Electricity Sales by Time Series Modelling (시계열모형에 의한 전력판매량 예측)

  • Son, Young Sook
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.3
    • /
    • pp.419-430
    • /
    • 2014
  • An accurate prediction of electricity supply and demand is important for daily life, industrial activities, and national management. In this paper electricity sales is predicted by time series modelling. Real data analysis shows the transfer function model with cooling and heating days as an input time series and a pulse function as an intervention variable outperforms other time series models for the root mean square error and the mean absolute percentage error.

On the Comparison of MTF in Sub-Band Coding Technique Employing the Human Visual System (인간의 시각특성을 고려한 Sub-Band 부호화에서 MRF 비교에 관한 연구)

  • 김용관;박섭형;이상욱
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.784-792
    • /
    • 1990
  • In this paper, attempts have been made to compare the subjective performance of sub-band coding (SBC) techniques incorporating four representative modulation transfer functions (MTF's) of th human visual system(HVS): Sakrison, Nill, Ngan, and Rao. In SBC, the frequency band of input signal is split into 16 equal sub-bands. In addition, 28 sub-band splitting schemd which splits more sub-bands in low spatial frequency is considered to compare the 4 MTF's effectively. In encoding of each sub-band, the weight of each sub-band obtained from the MTF of HVS is applied to bit allocation process which minimize the weighted mean square error (WMSE). The differential pulse code modulation(DPCM) coder is used to encode the lowest sub-band and the pulse code modulation(PCM) coder is used for the rest of sub-bands. It is found that the images incorporating the MTF of Rao yields the best results in subjective criteria, followed by Ngan, Nill, Sakrison, and the images not employing the HVS.

  • PDF

The study of Low Temperature Pasteurization System using High Voltage High Current Pulse Electric Field (고압 대전류 펄스 전계를 이용한 저온 살균장치 시스템 연구)

  • ;;;;Pavlov
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.162-165
    • /
    • 1998
  • The non-thermal pasteurization of foods using High Voltage High Current Pulsed Electric Fields (HVHC-PEF) is a promising technology and a sound complement or replacement to traditional thermal pasteurization. The conventional thermal method also inactivates bacteria and other microorganisms harmful to humans, but degrades natural color, flavor, texture and nutrients. At this point, a nonthermal pasteurization technique, HVPEF is thought to be a new processing technique which is able to produce a good quality foods nutritional as well as sensuous. In this paper, the system for HVHC-PEF pasteurization is presented. It use square wave pulse instead of exponential ones. So, power rating of system is reduced considerably. Design considerations for 20kV 500A class equipment are analyzed and experimental results are discussed.

  • PDF