• Title/Summary/Keyword: Square prism

Search Result 51, Processing Time 0.033 seconds

Size effect in concrete blocks under local pressure

  • Ince, R.;Arici, E.
    • Structural Engineering and Mechanics
    • /
    • v.19 no.5
    • /
    • pp.567-580
    • /
    • 2005
  • Numerous tests on concrete structure members under local pressure demonstrated that the compressive strength of concrete at the loaded surface is increased by the confinement effect provided by the enveloping concrete. Even though most design codes propose specific criteria for preventing bearing failure, they do not take into consideration size effect which is an important phenomenon in the fracture mechanics of concrete/reinforced concrete. In this paper, six series of square prism concrete blocks with three different depths (size range = 1:4) and two different height/depth ratios of 2 and 3 are tested under concentrated load. Ultimate loads obtained from the test results are analysed by means of the modified size effect law (MSEL). Then, a prediction formula, which considers effect of both depth and height on size effect, is proposed. The developed formula is compared with experimental data existing in the literature. It is concluded that the observed size effect is in good agreement with the MSEL.

Air-coupled ultrasonic tomography of solids: 2 Application to concrete elements

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.31-43
    • /
    • 2016
  • Applications of ultrasonic tomography to concrete structures have been reported for many years. However, practical and effective application of this tool for nondestructive assessment of internal concrete condition is hampered by time consuming transducer coupling that limits the amount of ultrasonic data that can be collected. This research aims to deploy recent developments in air-coupled ultrasonic measurements of solids, described in Part 1 of this paper set, to concrete in order to image internal inclusions. Ultrasonic signals are collected from concrete samples using a fully air-coupled (contactless) test configuration. These air coupled data are compared to those collected using partial semi-contact and full-contact test configurations. Two samples are considered: a 150 mm diameter cylinder with an internal circular void and a prism with $300mm{\times}300mm$ square cross-section that contains internal damaged regions and embedded reinforcement. The heterogeneous nature of concrete material structure complicates the application and interpretation of ultrasonic measurements and imaging. Volumetric inclusions within the concrete specimens are identified in the constructed velocity tomograms, but wave scattering at internal interfaces of the concrete disrupts the images. This disruption reduces defect detection accuracy as compared with tomograms built up of data collected from homogeneous solid samples (PVC) that are described in Part 1 of this paper set. Semi-contact measurements provide some improvement in accuracy through higher signal-to-noise ratio while still allowing for reasonably rapid data collection.

A Study for the Syndrome Differentiation of Retroverted Uterus Using Ultrasound (초음파 자궁형상진단을 이용한 자궁후굴증의 변증 진단 연구)

  • Hwang, Deok-Sang;Lee, Jae-Sung;Jeong, Eun-Jeong;Lee, Yoon-Jae;Lee, Kyung-Sub;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.25 no.3
    • /
    • pp.85-94
    • /
    • 2012
  • Objectives: We have studied the syndrome differentiation of ultrasound of retroverted uterus(RU) as the inspection in traditional Korean medicine. Methods: Eighty-four patients, who visited H clinic for infertility treatment, were recruited and evaluated by questionnaires and ultrasound, from April, 2012 to May, 2012. We used ultrasound(Logiq C3; GE Health care) for examination of RU. For statistics, we used Fisher's extract test to evaluate the RU and symptoms, and Chi-square test to evaluated the RU and syndrome differentiations, and Student T-test for the relationship between RU and each score of syndrome differentiation, using PASW Statistics(version 18.0.0) and GraphPad Prism(version 5.01). Results: 1. RU was correlated with moderate or severe dysmenorrhea and premenstrual lower abdominal pain. 2. In syndrome differentiation, blood stasis questionnaire was correlated with RU. 3. RU was related with dysmenorrhea, mass of low abdomen, pressure pain, clod of menstrual blood, dyspareunia. Conclusions: The ultrasound of RU might be related with the syndrome of blood stasis.

Experimental investigation of the stress-strain behavior of FRP confined concrete prisms

  • Hosseinpour, F.;Abbasnia, R.
    • Advances in concrete construction
    • /
    • v.2 no.3
    • /
    • pp.177-192
    • /
    • 2014
  • One of the main applications of FRP composites is confining concrete columns. Hence identifying the cyclic and monotonic stress-strain behavior of confined concrete columns and the parameters influencing this behavior is inevitable. Two significant parameters affecting the stress-strain behavior are aspect ratio and corner radius. The present study aims to scrutinize the effects of corner radius and aspect ratio on different aspects of stress-strain behavior of FRP confined concrete specimens (rectangular, square and circular). Hence 44 FRP confined concrete specimens were tested and the results of the tests were investigated. The findings indicated that for specimens with different aspect ratios, the relationship between the ultimate stress and the corner radius is linear and the variations of the ultimate stress versus the corner radius decreases as a result of an increase in aspect ratio. It was also observed that increase of the corner radius results in increase of the compressive strength and ultimate axial strain and increase of the aspect ratio causes an increase of the ultimate axial strain but a decrease of the compressive strength. Investigation of the ultimate condition showed that the FRP hoop rupture strain is smaller in comparison with the one obtained from the tensile coupon test and also the ultimate axial strain and confined concrete strength are smaller when a prism is under monotonic loading. Other important results of this study were, an increase in the axial strain during the early stage of unloading paths and increase of the confining effect of FRP jacket with the increase and decrease of the corner radius and aspect ratio respectively, a decrease in the slope of reloading branches with cycle repetitions and the independence of this trend from the variations of the aspect ratio and corner radius and also quadric relationship between the number of each cycle and the plastic strain of the same cycle as well as the independence of this relationship from the aspect ratio and corner radius.

Effect of Specimen Sizes and Shapes on Compressive Strength of Concrete (콘크리트의 압축강도에 공시체의 크기와 형상이 미치는 영향)

  • Yang Eun-Ik;Choi Joong-Cheol;Yi Seong-Tae
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.375-382
    • /
    • 2004
  • The compressive strength of concrete is used as the most basic and important material Property when reinforced concrete structures are designed. It has become a problem to use this value, however, because the control specimen sizes and shapes are different from every country. In this study, the effect of specimen sizes and shapes on compressive strength of concrete specimens was experimentally investigated based on fracture mechanics. Experiments for the Mode I failure was carried out by using cylinder, cube, and prism specimens. The test results are curve fitted using least square method(LSM) to obtain the new parameters for the modified size effect law(MSEL). The analysis results show that the effect of specimen sizes and shapes on ultimate strength is apparent. In addition, correlations between compressive strengths with size, shape, and casting direction of the specimen are investigated. For cubes and prisms the effect of placing direction on the compressive strength was investigated.

Two-Dimensional Lanthanum-BDC Coordination Polymer:Hydrothermal Synthesis and Structure of [La4(BDC)6(H2O)5](H2O)(BDC=benzene-1,3-dicaboxylate) (2차원 La-BDC 배위 고분자: [La4(BDC)6(H2O)5](H2O)의 수열합성 및 구조(BDC=benzene-1,3-dicaboxylate))

  • Kim, Hye Jin;Min, Dong Won;Heo, Hyun Su;Lee, Soon W.
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.6
    • /
    • pp.507-512
    • /
    • 2001
  • The hydrothermal reaction between lanthanum(Ⅲ) nitrate $(La(NO3)3${\cdot}$6H_2O)$ and benzene-1,3-dicarboxylic acid $(H_2BDC)$ in the presence of 1,2-bis(4-pyridyl)ethane gave a 2-D lanthnum-BDC coordination polymer with an empirical formula of $〔La_4$(BDC)_6(H_2O)_5$〕(H_2O)$ (1). X-ray structure analysis of compound 1 revealed that this polymer contains four distinct La metals. The three La metals are 7-coordinate with three different structures: a capped trigonal prism, a capped octahedron, and a pentagonal bipyramid. The remaining La metal has a 8-coordinate, square antiprismatic structure.

  • PDF

A simple calculation for the preoperative estimation of transverse rectus abdominis myocutaneous free flap volume in 2-stage breast reconstruction using a tissue expander

  • Kono, Hikaru;Ishii, Naohiro;Takayama, Masayoshi;Takemaru, Masashi;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.333-339
    • /
    • 2018
  • Background Flap volume is an important factor for obtaining satisfactory symmetry in breast reconstruction with a transverse rectus abdominis myocutaneous (TRAM) free flap. We aimed to develop an easy and simple method to estimate flap volume. Methods We performed a preoperative estimation of the TRAM flap volume in five patients with breast cancer who underwent 2-stage breast reconstruction following an immediate tissue expander operation after a simple mastectomy. We measured the height and width of each flap zone using a ruler and measured the tissue thickness by ultrasound. The volume of each zone, approximated as a triangular or square prism, was then calculated. The zone volumes were summed to obtain the total calculated volume of the TRAM flap. We then determined the width of zone II, so that the calculated flap volume was equal to the required flap volume ($1.2{\times}1.05{\times}$the weight of the resected mastectomy tissue). The TRAM flap was transferred vertically so that zone III was located on the upper side, and zone II was trimmed in the sitting position after vascular anastomosis. We compared the estimated flap width of zone II (=X) with the actual flap width of zone II. Results X was similar to the actual measured width. Accurate volume replacement with the TRAM flap resulted in good symmetry in all cases. Conclusions The volume of a free TRAM flap can be straightforwardly estimated preoperatively using the method presented here, with ultrasound, ruler, and simple calculations, and this technique may help reduced the time required for precise flap tailoring.

Effects of metal surface grinding at the porcelain try-in stage of fixed dental prostheses

  • Kilinc, Halil Ibrahim;Kesim, Bulent;Gumus, Hasan Onder;Dincel, Mehmet;Erkaya, Selcuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.317-324
    • /
    • 2014
  • PURPOSE. This study was to evaluate the effect of grinding of the inner metal surface during the porcelain try-in stage on metal-porcelain bonding considering the maximum temperature and the vibration of samples. MATERIALS AND METHODS. Ninety-one square prism-shaped ($1{\times}1{\times}1.5mm$) nickel-chrome cast frameworks 0.3 mm thick were prepared. Porcelain was applied on two opposite outer axial surfaces of the frameworks. The grinding was performed from the opposite axial sides of the inner metal surfaces with a low-speed handpiece with two types of burs (diamond, tungsten-carbide) under three grinding forces (3.5 N, 7 N, 14 N) and at two durations (5 seconds, 10 seconds). The shear bond strength (SBS) test was performed with universal testing machine. Statistical analyzes were performed at 5% significance level. RESULTS. The samples subjected to grinding under 3.5 N showed higher SBS values than those exposed to grinding under 7 N and 14 N (P<.05). SBS values of none of the groups differed from those of the control group (P>.05). The types of bur (P=.965) and the duration (P=.679) did not affect the SBS values. On the other hand, type of bur, force applied, and duration of the grinding affected the maximum temperatures of the samples, whereas the maximum vibration was affected only by the type of bur (P<.05). CONCLUSION. Grinding the inner metal surface did not affect the metal-porcelain bond strength. Although the grinding affected the maximum temperature and the vibration values of the samples, these did not influence the bonding strength.

Analysis of various statistical techniques used in the articles published during last 19 years in The Journal of Korean Acupuncture & Moxibusition Society (침구학회지 논문에 응용된 통계방식에 관한 연구 -1984 창간호부터 2002년 19권 6호까지 19년간-)

  • Lee, Seung-deok
    • Journal of Acupuncture Research
    • /
    • v.20 no.1
    • /
    • pp.144-158
    • /
    • 2003
  • This study was carried out to investigate what kinds of statistical techniques have been used to analyze data from oriental medicine research, For study, 551 original articles which used statistical techniques in their data analysis were selected form the articles published in The journal of Korean Acupuncture & Moxibustion Society(JKAMS) between 1984 to 2002. among them, 122 articles used descriptive statistics while 429 articles used inferential statistics for data analysis. For that 429 articles, t-test (189 articles), analysis fo variance (111 articles), chi-square test (14 articles), correlation (10 articles), regression analysis (4 articles), factor analysis(5 articles), or nonparametric test (23 articles) were chose to analyze the data. Nonparametric approach has substantial power in case data do not meet the assumption of normality. This method is not only easy to use ut also provides measures of the statistical variation of nominal and ordinal scale. This study shows that more and more recent papers use nonparametric test compared to the old articles. nine different statistical software or packages (SAS, SPSS, Statview, Minitab, Sigma plot, ISP, Graphpad prism, Excel, Access) have been used in the articles published JKMAS. High level statistical techniques such as SAS, SPSS, and Statview are user friendly and used most for acupuncture and Moxibustion research. Including tables and plots in an article facilitates understanding family process data from a descriptive standpoint, minimized erroneous statistical conclusions, and clarifies theoretically important relationships among variables. Table and plots have been used 500 and 233 articles, respectively. A computer procedure is proposed and illustrated with statistical packages using SAS, SPSS, Statview and ISP.

  • PDF

The Factors Influencing the Asthenopia of Emmetropia with Phoria (사위를 가진 정시안의 안정피로에 영향을 미치는 요인)

  • Kim, Jung-Hee;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.71-82
    • /
    • 2005
  • The aim of this study was to provide fundamental data for the factors influencing the asthenopia of emmetropia with phoria and alleviation of asthenopia. A total of 348 subjects, aged between 19 and 30 years old, who had no strabismus, an eye trouble or whole body disease, were examined using corrected visual acuity, corrected diopter, stereopsis and suppression tests from September of 2002 to September of 2004. We excluded 21 subjects for the following reasons: if they had an amblyopia affecting binocular vision or inaccurate data. After these exclusions, 327 subjects remained. We then individually measured the refractive error correction, pupillary distance, optical center distance, phoria, convergence, accommodation and the AC/A as well as the asthenopia during binocular vision using a questionnaire. After analysis of factors affecting asthenopia, we also examined the reductive effect of a prism on the asthenopia in subjects who had asthenopia. To determine the factors affecting asthenopia during binocular vision, statistic analyses were carried out using the Chi-square test and the multivariate Logistic regression model. The results of this study were as follow. For asthenopia during near binocular vision of emmetropia with phoria, in case of the lower the accommodation and convergence, a significantly higher rate of asthenopia was observed (p<0.001). When the AC/A is lower, the higher the rate of asthenopia was observed but not significantly and there was no association between phoria and asthenopia. When the multivariate logistic regression model was used to determine factors affecting binocular vision of emmetropia with phoria, in case of the lower accommodation and convergence, a significantly higher rate of asthenopia was observed. when the phoria is esophoria or higher exophoria, or when the AC/A is lower than normal, the higher the rate of asthenopia was observed but not significantly and there was no association between phoria. AC/A and asthenopia. Therefore accommodation and convergence could be predictive factors for asthenopia during near distance binocular vision. Prism was used among' subjects who had asthenopia during near distance binocular vision, the symptom of asthenopia was eased up to 74.2% in emmetropia with phoria.

  • PDF