• 제목/요약/키워드: Square Column

검색결과 338건 처리시간 0.023초

황룡사 목탑지 방형대석 검토 (Review of the square footstone of the wooden pagoda site in Hwangnyongsa Temple)

  • 김동열;천득염
    • 건축역사연구
    • /
    • 제24권5호
    • /
    • pp.33-40
    • /
    • 2015
  • The present study is aimed to reconsider the time of installation and the purpose of the square footstone located at the center of the wooden pagoda in Hwangnyongsa Temple, based on related precedent studies. Precedent studies are divided into two streams of assertions: one is that the square footstone was to support the major pillars at the time of building and the other is that it was installed to store Buddhist reliquaries inside the central foundation stone after the wood pagoda burnt down in the Invasion of Mongol. Summarizing the grounds with which the precedent studies support their assertions, they are the relation with Gaseopbul Yeonjwaseok, the emerging time of the square footstone, repairing work at the level of reconstruction, additional enshrinement of general Buddhist reliquaries and so on. The present study reviewed the key grounds suggested in the previous studies regarding the square footstone. First, it was determined that the square footstone has nothing to do with Gaseopbul Yeonjwaseok, after looking into the timings of appearance, condition and shape in literatures. Rather, it was assumed that Gaseopbul Yeonjwaseok resembles a stone column. Next, the square footstone is assumed to be installed after the 4th year of King Kwangjong's rule because the wood pagoda was lost in fire in the 4th year of Kwangjong's rule and it had been left alone for 68 years until the repair work finished in the 13th year of King Hyunjong. It is assumed that repair works at the level of reconstruction had been twice in total, say, once during King Kyungmun and Hyunjong, respectively. Next, looking into the establishment of the general Buddhist reliquaries and the repair work during King Kyungmun, it was not common then to enshrine additional Buddhist reliquaries when repair work progressed and so there was not an additional enshrinement of Buddhist reliquaries after King Kyungmun. However, it is hard to decide that there was no repair work at the level of reconstruction at that time. Last, we can find a similar case to the square footstone of the wood pagoda in Hwangnyongsa Temple in the copper pagoda in Japanese Yaksasa Temple. In conclusion, it is assumed that the wooden pagoda in Hwangnyongsa Temple was lost to the fire in the 4th year of King Kwangjong's rule and thus the square footstone had been used as Jinho stone to protect Buddhist reliquaries and used as a propping stone for the major pillars after King Hyungjong.

지관이 회전된 냉간성형 각형강관 T형 접합부의 최대내력(II)-주관 웨브 파괴모드- (Ultimate Strength of branch-rotated T-joints in Cold-formed Square Hollow Sections-Chord web failure mode-)

  • 배규웅;박금성;강창훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제15권1호
    • /
    • pp.69-76
    • /
    • 2003
  • 본 논문에서 새로운 냉간성형 각형강관 T형 접합부의 최대내력과 변형제한치에 대한 연구이다. 새로운 접합부는 지관을 트러스 평면에 대하여 $45^{\circ}$회전시켜서 주관에 용접하는 형상이고, 지관 $45^{\circ}$회전형 T형 접합부 실험결과 중에서 주관 웨브 파괴가 지배하는 접합부만을 대상으로 설정하였다. $16.7{\leq}2{\gamma}(B/T){\leq}33.3$이고 $0.63{\leq}{\beta}(b_1/B){\leq}0.7$ 범위의 지관 $45^{\circ}$회전형 T형 접합부에 대하여, 최대내력을 정의를 위한 변형제한치는 주관폭의 3% 변형량(3%B) 으로 제안하였다. $0.63{\leq}{\beta}{\leq}0.7$ 범위의 기본형에 대한 기존의 항복선모델을 검토하고, 지관 $45^{\circ}$회전형에 대한 내력식을 제안하였다. 제안내력식은 기둥좌굴이론에 근거하고 있고, 냉간성형시 발생한 곡률부분을 고려하였다. 최종적으로 최적화된 주관단면 선택을 위한, 항복응력도와 $2{\gamma}$의 최적조건을 제안하였다.

중심축 하중을 받는 각형 CFT 기둥의 장기거동에 관한 연구 (Long-Term Behavior of Square CFT Columns under Concentric Load)

  • 권승희;김태환;이태규;김윤용
    • 콘크리트학회논문집
    • /
    • 제17권2호
    • /
    • pp.281-290
    • /
    • 2005
  • 이 연구에서 중심축 하중을 받는 각형 CFT 기둥의 장기거동에 관한 실험과 해석을 수행하였으며, 이를 통해 각형 CFT 기둥의 장기거동을 예측할 수 있는 방법을 모색하고 그 거동 특성을 파악해 보고자 하였다. 중심축 하중에 대해 두 가지 가압 방법이 고려되었다. 첫째는 콘크리트에만 하중이 가해지는 경우이고, 둘째는 콘크리트와 강관에 동시에 하중이 가해지는 경우이다. 각형 CFT 기둥 실험체에 대한 삼차원 유한요소 모델로 해석을 수행하였으며, 해석결과는 실험결과를 매우 정확히 모사하였다. 따라서 강관과 콘크리트의 부착거동을 고려한 3차원 유한요소 모델링으로부터 실제 각형 CFT 기둥에 대한 장기거동 예측이 가능할 것으로 판단된다. 또한 실험과 해석결과로부터 다음의 거동 특성을 파악하였다. 콘크리트에만 하중이 가해지는 경우 구속압에 의해 유발되는 부착응력은 시간에 따라 증가하며, 강관과 콘크리트 사이의 미끄럼 또한 시간에 따라 증가한다. 강관에 의한 구속압은 시간에 따라 증가하는 반면. 가압판에 의한 구속압은 시간에 따라 감소한다. 강관과 콘크리트에 동시에 하중이 가해지는 경우 강관에 의한 콘크리트의 구속 효과와 미끄럼은 발생하지 않는다.

Rapid Repair of Severely Damaged RC Columns with Different Damage Conditions: An Experimental Study

  • He, Ruili;Sneed, Lesley H.;Belarbi, Abdeldjelil
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권1호
    • /
    • pp.35-50
    • /
    • 2013
  • Rapid and effective repair methods are desired to enable quick reopening of damaged bridges after an earthquake occurs, especially for those bridges that are critical for emergency response and other essential functions. This paper presents results of tests conducted as a proof-of-concept in the effectiveness of a proposed method using externally bonded carbon fiber reinforced polymer (CFRP) composites to rapidly repair severely damaged RC columns with different damage conditions. The experimental work included five large-scale severely damaged square RC columns with the same geometry and material properties but with different damage conditions due to different loading combinations of bending, shear, and torsion in the previous tests. Over a three-day period, each column was repaired and retested under the same loading combination as the corresponding original column. Quickset repair mortar was used to replace the removed loose concrete. Without any treatment to damaged reinforcing bars, longitudinal and transverse CFRP sheets were externally bonded to the prepared surface to restore the column strength. Measured data were analyzed to investigate the performance of the repaired columns compared to the corresponding original column responses. It was concluded that the technique can be successful for severely damaged columns with damage to the concrete and transverse reinforcement. For severely damaged columns with damaged longitudinal reinforcement, the technique was found to be successful if the damaged longitudinal reinforcement is able to provide tensile resistance, or if the damage is located at a section where longitudinal CFRP strength can be developed.

기둥의 강·연성축을 고려한 브레이싱된 정방형 3차원 강골조 구조물의 최적설계 (Optimum Design of Braced Three Dimensional Square Steel Frame Structures Considering Arrangement of Major-minor axis of Column)

  • 김기욱;박문호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.259-267
    • /
    • 2004
  • 우리주변에서도 많이 존재하고, 현재 시공중인 강골조 구조물이 대부분 강 연성축을 고려하지 않고 일방향 쪽으로만 시공하고 있는 것이 현실이다. 이로 인하여 재료가 과다로 쓰여지고 있으며, 같은 재료를 강 연성 축의 배치만 잘 하여도 구조물의 안전성과 경제성 측면에서 탁월하다는데 착안하였다. 또한, 국내 강구조물의 대부분이 허용응력설계법을 이용한 과다설계로, 다른 설계법으로의 전환이 필요하다고 생각되어 본 논문을 수행하게 되었다. 현재 기둥의 강 연성축 배열은 미국시방서 AISC-LRFD에 일부 기술되어 있을 뿐, 구체적인 효율성과 경제성에 관해서는 미흡한 상태이다. 본 연구에는 3차원 강뼈대구조물에서 기둥의 강 연성 축 배치와 브레이스의 배치, 브레이스의 연결방법 및 각국의 시방코드별로 수행한 최적설계를 비교하여 보다 향상되고 합리적인 최적설계의 방향을 제시하고자 한다.

강관 보강형 충전 각형강관 기둥-보 플랜지 접합부의 인장거동에 관한 실험적 연구 (Tensile Behavior of Concrete-Filled Square Steel Tubular Column-Beam Flange Connections with Stiffeners)

  • 유영찬;강현식;문태섭
    • 한국강구조학회 논문집
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2001
  • 본 연구는 콘크리트충전 각형강관을 이용한 기둥-H형 보 접합부에 있어서 시공성과 충전성을 고려하여 강관 기둥을 외부에서 보강한 충전 각형강관 기둥-H형강보접합부를 개발하고자 하며 이러한 접합방식 개발을 위한 기초적 연구로 보의 인장플랜지와 강관기둥 접합부의 인장거동을 실험적으로 관찰하여 제시한 접합부의 내력 및 변형 특성을 파악한다. 시험체의 변수는 각형강관 기둥의 보강 두께(T=9, 18, 27mm)와 높이(H=50, 80mm)로 계획하여 총 4개의 시험체를 제작하였다. 접합부의 항복내력의 평가로 항복선 이론을 적용한 기존의 연구를 수정하여 실험치와 비교한 결과 비교적 좋은 대응을 나타냈다. 본 연구의 접합방식은 외부에서 강관 기둥을 보강하는 간단한 방법으로 보붕괴형의 강접합을 얻을 수 있으며, 콘크리트 충전성을 확보할 수 있어 시공성에 있어서 장점으로 인정된다. 강관기둥의 두께가 8mm 인 것을 고려하면 실제 구조물의 설계에 적용할 수 있는 가능성이 있는 것으로 판단되며, 구체적인 설계방법을 위해서는 추치해석적인 방법에 의한 연구와 보완적인 실험이 필요한 것으로 생각된다.

  • PDF

반복하중을 받는 콘크리트충전 각형강관 보-기둥의 거동 (Behavior of Concrete-Filled Square Tubular Beam-Column under Cyclic Load)

  • 강창훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.387-395
    • /
    • 2000
  • 본 연구는 콘크리트충전 각형강관(CFT) 기둥의 강도와 변형능력의 평가 및 내진성능에 대한 기초 자료의 제시를 목적으로 한다. 실험체는 초고층 건물의 최하단기둥의 응력분포를 가정하여 켄틸레버형 기둥으로 하고, 총 18개의 실험체가 일정 축력과 반복 횡하중 하에서 실험되었다. 본 실험에 적용된 주요변수는 강관의 폭/두께 비, 세장비 (LO/D), 그리고 축력비이다. 각 변수가 기둥의 강도, 변형능력, 그리고 에너지 흡수능력에 미치는 영향이 기술되었고, 각국 규준식과 실험결과를 비교하였다. 분석결과, 피복형 한국강구조학회 규준은 합성 단면적과 탄성계수를 AIJ와 AISC-LRFD 수준으로 수정한다면, 충전형에도 적용가능 할 것으로 판단된다. 마지막으로, 구속효과를 고려하여 단면의 소성해석을 통하여 구한 B. Kato의 CFT 기둥의 휨내력 제안식은 실험결과와 좋은 대응을 나타내고 있다.

  • PDF

Tests and mechanics model for concrete-filled SHS stub columns, columns and beam-columns

  • Han, Lin-Hai;Zhao, Xiao-Ling;Tao, Zhong
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.51-74
    • /
    • 2001
  • A series of tests on concrete-filled SHS (Square Hollow Section) stub columns (twenty), columns (eight) and beam-columns (twenty one) were carried out. The main parameters varied in the tests are (1) Confinement factor (${\xi}$) from 1.08 to 5.64, (2) concrete compression strength from 10.7MPa to 36.6MPa, (3) tube width to thickness ratio from 20.5 to 36.5. (4) load eccentricity (e) from 15 mm to 80 mm and (5) column slenderness (${\lambda}$) from 45 to 75. A mechanics model is developed in this paper for concrete-filled SHS stub columns, columns and beam-columns. A unified theory is described where a confinement factor (${\xi}$) is introduced to describe the composite action between the steel tube and filled concrete. The predicted load versus axial strain relationship is in good agreement with stub column test results. Simplified models are derived for section capacities and modulus in different stages of the composite sections. The predicted beam-column strength is compared with that of 331 beam-column tests with a wide range of parameters. A good agreement is obtained. The predicted load versus midspan deflection relationship for beam-columns is in good agreement with test results. A simplified model is developed for calculating the member capacity of concrete-filled SHS columns. Comparisons are made with predicted columns strengths using the existing codes such as LRFD (AISC 1994), AIJ (1997), and EC4 (1996). Simplified interaction curves are derived for concrete-filled beam-columns.

콘크리트 충전 각형강관 기둥부재의 한계축력 및 누적한계축력에 관한 연구 (Study on the Strength of Limit Axial Force and Accumulated Limit Axial Force of Concrete Filled Square Tube Columns)

  • 서성연;정진안;김성용
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.605-615
    • /
    • 2005
  • 수평하중을 받는 콘크리트충전 각형강관 기둥의 축력과 변형능력의 관계를 조사하기 위하여 실험 및 해석적 연구를 수행하였다. 36개 기둥으로 구성된 실험 시리즈는 일정 축하중과 수평하중 하에서 반복실험을 실시하였다. 반복 수평하중을 받는 기둥이 저항할 수 있는 축하중을 보증내력 한계축력이라고 규정하였으며, 해석 모델은 수평하중을 받는 캔틸레버 기둥을 모델화하였다. 반복 횡하중을 받는 기둥의 축하중을 누적보증내력 한계축력이라고 정의하였다. 본 연구의 목적은 주어진 동일부재각에 부합하는 축력과 수평하중을 받는 콘크리트 충전강관 기둥의 보증내력 한계축력을 연구하기 위한 것이며, 두 번째는 콘크리트 충전강관 기둥의 누적보증내력 한계축력과 보증내력 한계축력의 비교가 본 연구의 목적이다.

일정축력하에 고온을 받는 고강도 콘크리트 충전강관 기둥의 구조적 거동에 관한 연구 (Experimental Evaluation of Fire Behavior of High-Strength CFT Column with Constant Axial Load)

  • 정경수;최인락;김도환;김진호
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.71-80
    • /
    • 2013
  • 구조, 시공 및 내화측면에서 우수한 콘크리트충전강관(CFT)부재에 대해서 구성재료의 강도가 높은 경우 즉, 콘크리트 압축강도가 100MPa 이상이면서 강관의 항복강도가 650MPa 이상인 경우에 대한 내화성능 평가실험 및 해석적 연구는 미비한 실정이다. 본 연구에서는 이러한 부재에 대해서 내화성능 거동을 파악하고자 ${\Box}-400{\times}400{\times}15$, 부재길이 3,000mm인 실물대 중심재하 내화실험을 행하였다. 실험변수는 중심축력을 5,000kN과 2,500kN로 하였다. 실험결과, 고강도 콘크리트의 폭렬 및 콘크리트 내부 균열에 의하여 축하중이 클수록 조기에 내력을 상실하였다. 또한, 유한차분법과 변형률적합조건을 이용한 비정상온도해석 및 응력해석을 수행하였으며, 고강도 재료모델은 Eurocode모델을 이용하였다. 해석모델은 시간-축변위 관계를 합리적으로 예측할 수 있었다.