• Title/Summary/Keyword: Sprinkler

Search Result 282, Processing Time 0.035 seconds

Development of Collection Method of Arboreal Parasite Larvae for the Biological Control against Pine Needle Gall Midge, Thecodiplosis japonensis Uchida et Inouye (기생봉사육용(寄生蜂飼育用) 솔잎혹파리 유충채집(幼蟲採集)에 관(關)한 연구(硏究))

  • Chung, Sang Bae;Kim, Chul Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.3
    • /
    • pp.334-341
    • /
    • 1997
  • Artificial precipitation test with sprinkler system was carried out to develop the collection method of arboreal larvae(proctotrupoid wasps) of pine needle gall midge for biological control in 1995. Effects of larvae falling on each amount of precipitation, season of precipitation and time of precipitation of a day following artificial precipitation were examined during the period of larvae falling season. The results obtained were summarized as follows; 1. Artificial precipitation with sprinkler system was highly effective for collection of pine needle gall midge larvae and the most suitable amount of precipitation was 5.3-9.4mm; application amount and hours of water were $8,000-16.000{\ell}$ and 180-360 minutes, respectively. 2. The most effective period of larvae collection for artificial precipitation was approximately 20 days, from early through mid November, and larvae falling was 93.4% of the total number of larvae collection during this period. 3. Larvae falling from the tree crown was not affected by the artificial precipitation for the precipitation hour intervals in a day. 4. The percentage of parasitism of collected larvae of pine needle gall midge in November exceeded that of December but was not significantly different between two seasons. 5. Artificial precipitation of sprinkler system was effective in reducing 34% of gall formation after one year at collected sites of pine needle gall midge larvae. 6. The collection method of larvae following artificial precipitation was effective in reducing the expenses by 14-50% than that of collection method of infested needles.

  • PDF

Use of Sprinkler System for Control of Pine Needle Gall Midge, Thecodiplosis japonensis Uchida et Inouye -II. Effectiveness of Ground Application with Low Concentration of Insecticides (분무장치(噴霧裝置)를 이용(利用)한 솔잎혹파리 방제(防除)에 관(關)한 연구(硏究) -II. 저농도(低濃度) 지면약제살포(地面藥劑撒布) 효과(效果) -)

  • Chung, Sang Bae
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.4
    • /
    • pp.571-576
    • /
    • 1998
  • Experiments were conducted to evaluate the efficacy of the application of low concentration insecticides by sprinkler system for control of the pine needle gall midge, Thecodiplasis japonensis, by killing the adults emerging and copulating near the ground. For ground spray, 2 insecticides of fenitrothion and deltamethrin, dilutions of $2,000{\times}$ and $3,000{\times}$ deltamethrin, and 3 spray intervals of 1-3 day were tested at the peak time of adult emergence during the day time. The results are as follows ; 1. Ground spray of fenitrothion 50% EC and deltamethrin 1% EC were found to be highly effective for control of the pine needle gall midge. Average gall formation by fenitrothion, deltamethrin and untreated ones were 3.40%, 5.23% and 45.69%, respectively ; control value of both insecticides exceeded 88%. 2. As a ground spray of deltamethrin 1% EC, dilution $2,000{\times}$ was significantly different from $3,000{\times}$ in gall formation rates. Average gall formation of $2,000{\times}$ plots and $3,000{\times}$ treated ones were 5.23% and 18.00% ; control values were 89.44% and 63.66%, respectively. 3. Diurnal treatment of ground spray was found to be highly effective for control of pine needle gall midge. 4. In particular, control by ground application of dilutions $2,000{\times}$ and $3,000{\times}$ of deltamethrin is suggested because it does not have an adverse effect on arthropods of the ground surface such as ants and spiders.

  • PDF

A Comparative Analysis of Dust Particles Collected by Cleaning Equipments in Subway Tunnel (도시철도 터널 내 청소장치별 집진먼지 비교 분석)

  • Lee, Young-Kwon;Kim, Il-Hong;Jo, Byung-Ki;Kim, Man-Hwa;Park, Jong-Heon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1388-1398
    • /
    • 2011
  • Air pollution in subway tunnel is primarily caused from the wear of metallic materials. As undesirable substance, PM(Particulate Matter) can especially harm the health of passengers and workers as well as clog the main parts of rolling stock such as inverters. To improve the air quality in subway tunnel, SMRT(Seoul Metropolitan Rapid Transit Corporation) has developed anti-pollution devices such as Magnetic Dust Collector, Vacuum Cleaner For Rail Road and Particulate Removing Sprinkler Vehicle. Introducing these mechanical devices, this paper is mainly devoted to explaining the characteristics of collected dust according to the result of particle-size analysis and componential analysis.

  • PDF

Fire & Life Safety Challenges in Sustainable Tall Building Design

  • Li, Fang;Reiss, Martin
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The movement towards sustainable building design can result in unique fire protection challenges and concerns, especially with super tall buildings in relationship to traditional prescriptive code compliance. Different countries haves different code requirements as well as local best practices and may cause conflict with the design features when designing green buildings. These include, but not limited to green roofs, sprinkler water quality and testing, fire department access and areas of refuge with direct or indirect impact by the perspective code compliance. The solutions to these prescriptive code challenges and fire safety concerns can range from simple alternatives to more detailed engineering performance-based design analyses with good solid practice.

Effectiveness of Friction Loss Calculation Used for Water Mist Fire Extinguishing System on Marine Vessels

  • Lee Kyung-Woo;Kim You-Taek;Lee Young-Ho;Kim Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.86-97
    • /
    • 2005
  • Nowadays, Water Mist Fire Extinguishing System is increasingly used in maritime field for various application. The fire extinguishing capability of the system should be verified by hydraulic calculation in the same manner as the conventional water based fire extinguishing system such as sprinkler system. water spray system and etc. Additionally, the review of effectiveness of friction loss calculation method used for hydraulic calculation is needed because the pipe flow characteristic of its piping system has higher Reynolds number than that of the conventional system. In this paper the review work was carried out based on the NFPA Code 750.

A Study on Spray Characteristics of Water Mist Nozzle with Mid-low Pressure for Fire Suppression (화재용 중저압 물분무 노즐의 분무특성에 관한 연구)

  • 김성찬;유홍선;박현태;방기영
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.28-32
    • /
    • 2003
  • The present study investigates the spray characteristics of water mist nozzle with mid-low pressure for fire suppression. The examined nozzle types are swirl and spiral nozzle. The result shows that K factor of water mist nozzle is much smaller than those of general sprinkler. Spray angle of spiral nozzle is largest and more than $150^{\circ}$. SMD(Sauter Mean Diameter) of water mist nozzles is ranged between 100 and 200$\mu\textrm{m}$through measuring by image processing method. The spray pattern of spiral nozzle represent that water flux of first stream is 2 times larger than that of second stream. This study will contribute better understandings of the water-mist spray characteristics and useful daia for developing the water-mist nozzles.

Distribution Characteristics of a Mini -Sprinkler without a Bridge (Non-bridge 형 미니스프링쿨러의 살수 특성)

  • 이남호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.1
    • /
    • pp.66-72
    • /
    • 2000
  • A study was conducted to find distribution patterns of minisprinkler without a bridge for the desing of microirrigation systems. The experiments were executed in a plastic house to minimize the effect of the wind. Data were collected at four different operation pressures and at 3 different riser heights. Sprayed water were collected by aluminium cans with 65mm diameter and 100mm height placed at 0.3m grid spacing . A schematic distribution pattern with distance from a minisprinkler was suggested for the layout design of the minisprinkler. Distribution pattern of the minisprinkler was found irregular in space. Distributin performance characteristics of the minisprinkler such as effective radius. , effective area, mean application depth, absolute maximum application depth, effective maximum application depth and coefficient of variation were determined. It was indicated that there is a trend of decrease in variation coefficient adn better water distribution by the increase in operation pressures and riser heights.

  • PDF

Investigation of porosity on the galvanized steel welds with GMAW for fire sprinkler pipes (소방배관용 아연도금강재의 GMA용접에 따른 용접부의 기공발생조사)

  • Lim, Young-Min;Kim, Nam-Hoon;Koh, Jin-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.379-381
    • /
    • 2011
  • 본 논문에서는 피복아크용접(SMAW)을 자동용접으로(GMAW) 전환시키기 위한 기초 연구로서 GMA용접가스가 기공율에 미치는 영향을 보고자 한다. 기공율 평가를 위해 반자동 소방용 분기배관실험장치를 제작하였다. 분기배관의 기공율을 평가하기 위해 보호가스 3종(Ar, $CO_2$, 8:2 혼합가스), 전압을 변수로 설정하여 GMA용접을 실시하였다. 용접을 실시한 시편을 용접방향으로 절단하여 기공율 평가를 실시하였다.

  • PDF

Extinguishing Characteristics of Cooking Oil Fire by Water Mist added with AFFF Agent (수성막포 약제를 첨가한 미분무수의 식용유 화재 소화특성)

  • Shin, Chang-Sub;Kim, Seong-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.5
    • /
    • pp.21-27
    • /
    • 2009
  • Effective way of cooking oil fire extinguishment is using water mist system which has cooling and smothering effects. Low pressure water mist system has advantage because it is compatible with existing sprinkler systems. To increase the effectiveness of low pressure water mist system, additives can be used which increase the momentum of water particle and the chemical effect. In this experiment, aqueous film forming form(AFFF) agent is used as additive and the effect of additive concentration and water pressure are experimented. For the extinguishment of cooking oil fire such as soybean and olive oils, AFFF agent is effective and can decrease the fire extinguishing time and water consumption.

Numerical Study on Fire Suppression using a Water-mist System Considering Droplet Breakup (액적분열을 고려한 미세물분무 화재제어에 대한 수치해석)

  • Ko, Seung-Woo;Ko, Kwon-Hyun;Ryou, Hong-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.625-629
    • /
    • 2006
  • This paper describes the effect of the droplet breakup process on fire suppression using a water-mist system, which is considered as a alternative to sprinkler fire suppression system. In the evolution of the water-mist, the droplet breakup process is an important phenomenon because it may significantly affect the droplet evaporation rate. The Fire Dynamics Simulator (FDS, Ver. 4.0) code, which is widely used for the simulation of fire dynamics, is used for the present simulation, and it is modified to consider the droplet breakup phenomena. The Prediction by the modified code shows good agreement with experimental data for the temperature. The original FDS predicts higher temperature about $30^{\circ}C$ than experimental data. From the results, it is concluded that the droplet breakup phenomena must be considered for more precise simulation of fire suppression process.