• Title/Summary/Keyword: Spray pump

Search Result 82, Processing Time 0.025 seconds

Spray Characteristics of Supersonic Liquid Jet by a Nozzle Geometry of Miniature High-Pressure Injection System (축소형 초고압 분사 시스템의 노즐 형상에 따른 초음속 액체 제트 분무 특성에 관한 연구)

  • Shin, Jeung-Hwan;Lee, In-Chul;Kim, Heuy-Dong;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.177-180
    • /
    • 2010
  • Two-stage light gas gun, sorted with Ballistic Range System, is used to research spray characteristics of supersonic liquid jets. When high pressure tube was pressurized to the 135 bar, diaphragm films which composed with OHP film are ruptured. Expansion gases accelerate a projectile approximately 250 m/s at the exit of pump tube. And accelerated projectile collides with liquid storage part and liquid jets were injected into supersonic conditions. Supersonic liquid jets show the multiple jets and generate shockwave at the forward region of jets. Supersonic liquid jets of speed and shockwave angle have different value at each case. Supersonic liquid jets with minimum velocities are injected with M=1.53 at the geometry condition of L/d=23.8.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

A Study on Optimization of Spray Type Flue Gas Desulfurization (FGD) System (모사 탈황흡수탑을 이용한 Spray Type 탈황설비 최적운전 방안에 관한 연구)

  • An, Hi-Soo;Park, Seung-Soo;Kim, Ki-Hyoung;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.18 no.1
    • /
    • pp.29-35
    • /
    • 2007
  • Recently, due to narrow margin on design factor of flue gas desulfurization (FGD) systems or aging of systems, some problems such as decrease of $SO_2$ removal efficiency and difficulty on coping with unstable state are arising on FGD systems. On this study, to cope with these problems several methods such as adjustment of reagent pH, inlet $SO_2$ concentration, variation of units of operation pump, installation of liquid distribution ring (LDR) were attempted to increase the $SO_2$ removal using spray type simulated FGD system. Also, sulfite and Al/Fx ion effects on limestone blinding were experimented. When three absorber recirculation pumps were operated, $SO_2$ removal was increased by 12% in comparison with that of two pumps operation. $SO_2$ removal was increased by 2~7% after installation of LDR. Dissolved oxygen increased up to 0.5 ppm and limestone binding effect was alleviated after injection of dibasic acid (DBA) with the concentration of 500 and 1,000 ppm. When $Al^{3+}$ and $F^-$ ions were coexisting, the dissolution rate of limestone was decreased by 20%.

Improved Injection Behavior with the Addition of Granulated β-Tricalcium Phosphate in Brushite Bone Cement

  • Jo, Hyun-Ho;Oh, Kyung-Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.6
    • /
    • pp.590-596
    • /
    • 2018
  • To improve the injection behavior of brushite cement, dense ${\beta}-Ca_3(PO_4)_2$ (${\beta}-TCP$) granules were added to the starting material. The spherical ${\beta}-TCP$ granules prepared by spray-drying and subsequent sintering at $1000{\sim}1200^{\circ}C$ accounted for fractions of from 0.5 to 0.7 of the total ${\beta}-TCP$. The injection behavior was evaluated by measuring the injected mass divided by the loaded mass of paste in the syringe pump. The injected amount was increased with the increase in the fraction and sintering temperature of ${\beta}-TCP$ granules, except at $1200^{\circ}C$. The increase in the fraction of ${\beta}-TCP$ and its sintering temperature resulted in a decrease in the plastic limit, which is the volume of water required to liquefy the compact. The rest water could be utilized in the cement with the reduced plastic limit for improved injectability. The amounts of rest water assigned for powdery phase were estimated, and correlated with the injectability of paste.

The Study on the Drag Reduction for Gas/Liquid Two Phase Flow (기-액(氣-液) 2상유동(二相流動)시 항력(抗力)에 관(關)한 연구(硏究))

  • Cha, K.O.;Oh, Y.K.;Kim, J.G.
    • Journal of ILASS-Korea
    • /
    • v.1 no.3
    • /
    • pp.20-28
    • /
    • 1996
  • It is well known that drag reduction in single phase liquid flow is affected by polymer material, molecular weight, polymer concentration, pipe diameter, and flow velocity. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research of drag reduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction whether polymer is added in the horizontal two phase system or not. Experiment has been conducted in a test section with 24 m of the inner diameter and 1,500 mm of the length. The used polymer materials are two kinds of polyacrylamide[PAAM] and co-polymer[A611P]. The polymer concentration was varied with 50, 100 and 200 ppm under the same experimental conditions. Experimental results were shown that the drag is higher reduced by co-polymer rather than polyanylamide.

  • PDF

Airway Management in the Patients of Expected Difficult Intubation -A Case Report- (어려운 기관 내 삽관이 예상되는 환자의 기도관리 -증례 보고-)

  • O, Se-Ri;Lee, Jin-Han
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.10 no.2
    • /
    • pp.190-196
    • /
    • 2010
  • Difficult airway management including difficult intubation, difficult ventilation and difficult mask ventilation is a life threatening issue during anesthesia care. A 23-year-old woman with Treacher Collins syndrome was scheduled for distraction osteogenesis. She had hypoplasia of mandible and malar bone, bilateral deformities of auricles with partial deafness and antimongoloid slant of the palpebral fissures. A 56-year-old woman with mandibular hypoplasia due to childhood trauma was scheduled for distraction osteogenesis. She had a history of difficult intubation. We anticipated a difficult intubation and ventilation. Fiberoptic bronchoscopic guided awake intubation was selected for anesthesia induction. After intravenous injection of midazolam and remifentanil, 10% lidocaine pump spray on the pharyngolarynx with a direct laryngoscope and on the nasal canal. However fiberoptic bronchoscopic guided awake intubation was failed due to severe gag reflex. After intravenous injection of propofol and remifentanil using the target controlled infusion (TCI), mask ventilation was easily performed and, after intravenous injection of vecuronium, fiberoptic bronchoscopic guided intubation was easily performed using a wire reinforced endotracheal tube. The operation was completed successfully without any adverse events.

A Study on Optimal Design of Direct Needle-driven Piezo Injector for Accomplishing Injection Pressure of 1800 bar (분사압력 1800 bar 실현을 위한 직접 니들구동방식 피에조 인젝터 설계 최적화 연구)

  • Han, Sangik;Kim, Juhwan;Ji, Hyungsun;Go, Junchae;Kim, Jinsu;Lee, Jinwook
    • Journal of ILASS-Korea
    • /
    • v.21 no.3
    • /
    • pp.121-129
    • /
    • 2016
  • The advantages of the common rail fuel injection system architecture have been recognized since the development of the diesel engine. In common rail systems, a high-pressure pump stores a reservoir of fuel at high pressure up to and above 2000 bar. And solenoid or piezoelectric valves make possible fine electronic control over the fuel injection time and quantity, and the higher pressure that the common rail technology makes available provides better fuel atomization. In this study, the direct needle-driven piezo injector was investigated for accomplishing injection pressure of 1800 bar by optimal design by simplification of component and changing number of springs and plates of DPI. It was found that a direct needle-driven piezo injection system features the prototype DPI for passenger vehicle to operate at 1800 bar of injection pressure.

The Effect of Pressure and Hose Length on the Travelling Distance of Particles in Power Sprayer (토출압력(吐出壓力) 및 호오스길이가 도달성(到達性)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kwon, Soon Hong;Choi, Kyu Hong
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.30-35
    • /
    • 1983
  • To investigate the factors affecting the transportability of spray droplets, the maximum distance, the effective distance, the ratio of even distribution, and the diameters of particles were measured in accordance with the different pressure levels of power sprayer using 3 hole swath type nozzle, and the results are summerized as follows; 1. The distance of the most dense point from the nozzle was shortened by 0.5 meter with the 100-meter-long hose. The maximum reaching distances were reduced by 1.5 and 1.0 meters for the 13m/m and the 8.5 m/m hoses respectively, and the effective distance were reduced by 0.5 meter for both cases. 2. The effective distance can not be extended beyond 14 meters even if the length of hose is minimized at the rated pump pressure 28 kg/$cm^2$, it was 1 meter longer for 13m/m hose compared to the 8.5m/m one. 3. In case of 13m/m hose, the most dense point can be extended further by 0.5 meter increasing the pump pressure by 8 kg/$cm^2$, and the maximum distance and effective distance were increased by 2.0 and 0.5 meters respectively. There was no significant effect of pressure changes on the transportability in case of 8.5m/m hose. 4. Both the reduction of hose length and the increase of pump pressure influenced in large extent to the atomization effect of droplets. It was noticed that the diameter of droplet is related to the pump pressure and inside diameter of hose. 5. The pressure drop in 100-meter-long and l3m/m hose was 5~7kg/$cm^2$ at the pump pressure range of 25~33kg/$cm^2$, and it is an equivalent of 2% per 10 meter length of hose.

  • PDF

Methodology for Quantitative Monitoring of Agricultural Worker Exposure to Pesticides (농작업자에 대한 농약 노출의 정량적 측정 방법)

  • Kim, Eun-Hye;Lee, Hye-Ri;Choi, Hoon;Moon, Joon-Kwan;Hong, Soon-Sung;Jeong, Mi-Hye;Park, Kyung-Hun;Lee, Hyo-Min;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.507-528
    • /
    • 2011
  • Agricultural workers who mix/loads and spray pesticide in fields expose to pesticide through dermal and inhalation routes. In such situation, exposed amount should be measured quantitatively for reasonable risk assessment. Patch, gloves, socks and mask will be good materials for monitoring for dermal exposure while personal air monitor equipped with solid adsorbent and air pump will be a tool for inhalation exposure. For extrapolation of absorbed amount in dermal exposure matrices and of trapped amount in solid sorbent to total deraml or inhalation exposure, Korean standard body surface area and respiration rate were proposed in substitution of EPA data. Important exposure factors such as clothing and skin penetration ratio of dermal and inhalation exposure were suggested based on Spraying time for exposure monitoring must be long enough that the amount of pesticide to get absorbed/trapped in exposure matrices results in reasonable analytical value. In domestic case for the both of speed sprayer and power spray machine, spraying time of 20~40 minutes (0.1~0.2 ha) will be reasonable per single replicate before extrapolating to 4 hours a day with triplicates experiment.

Analysis of a Continuous and Instantaneous Vacuum Drying System for Drying and Separation of Suspended Paricles in Waste Solvent (폐용제에 함유된 입자의 건조 및 분리용 연속식 순간 진공건조시스템 해석)

  • 구재현;이재근
    • Resources Recycling
    • /
    • v.9 no.4
    • /
    • pp.28-36
    • /
    • 2000
  • This study describes to analyze the characteristics for separation and recovery of both the dried particles and the purified solvent from the waste solvent through the vaporization process by the continuous and instantaneous vacuum drying system. The vacuum drying system for the waste solvents recovery consists of a feeding pump, a double pipe heat exchanger, a vacuum spray chamber, and a condenser. The vacuum drying system heats the waste solvent to the vapor in the double pipe heat exchanger and the expanded vapor is sprayed at the end of the tube. The vaporized solvent in the condenser are recovered. The particles in the waste solvent are separated and dried from the vapor in the vacuum spray chamber. Performance evaluation of the vacuum drying system was conducted using the mixture of the dried pigment particles and benzene or alkylbenzene as test samples. For the mixture of 10 wt% pigment particles an 90% benzene, the recovery efficiency of benzene was 88% with the purity of 99% and the recovery efficiency of dried particles was 94% with the moisture of 1.1 wt%. The size of pigment particles was decreased from $6.5\mu\textrm{m}$ to $5.6\mu\textrm{m}$ in diameter due to high speed spraying and dispersion in the vacuum drying system during drying process. Therefore, the vacuum drying system showed to be an effective method for separating particles and solvent in the waste solvent.

  • PDF