• 제목/요약/키워드: Spray fire

검색결과 194건 처리시간 0.021초

옥내용 뿜칠내화피복재의 촉진내구성 시험방법 연구 (Development of Acceleration Duability Test Method for Fireproof Spray-Applocation)

  • 김대회;이건철;이세현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.104-105
    • /
    • 2013
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. Fireproof spray-application also loses its performance and this performance loss of thr fireproof spray-application is very important because fire resistance of buildings depends on fireproof spray-application. So this study is to develop Acceleration durability test method of Fireproof spray-application, and use the Certification of fire resistant coating system.

  • PDF

2유체 미세 물분무 소화노즐의 분무유동 특성 (Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression)

  • 김봉환;최효성;김동건
    • 한국기계가공학회지
    • /
    • 제10권3호
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

스프링클러 분무 해석에 영향을 미치는 통계적액적군집의 영향 (Effect of the Statistical Droplet Parcel on Numerical Simulation of Sprinkler Spray)

  • 김성찬;이상우;박원주
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.363-370
    • /
    • 2008
  • The present study has been performed to investigate the effect of statistical number of droplets on the simulation of the sprinkler spray using fire field model. In order to simulate the sprinkler spray characteristics, the present study uses NIST Fire Dynamics Simulator version 5.2. A group of Lagrangian particle with similar droplet characteristics, such as diameter, velocity, temperature and so on, is represented by parcel concept to decrease the total number of droplets tracked in the simulation. The present study introduces a new parameter to represent the ratio between real number of droplets and computational parcels. The dependency of the number of parcels on the fire suppression characteristics and spray patterns is quantitatively examined for different ratio between the real number of droplets and computational parcels.

  • PDF

관창의 유동특성에 관한 연구 (A Study on the Flow Characteristics of the Spray Nozzle)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제17권3호
    • /
    • pp.55-60
    • /
    • 2003
  • 본 연구에서는 관창의 유동특성예측을 위한 해석이론을 정립하고 수치해석으로부터 방수량과 방수형태를 예측하였다. 예측 데이터로부터 관창의 방수형태가 노즐과 니들의 위치에 따라 결정됨을 알 수 있었고, 관창의 유동특성은 노즐과 니들의 형상에 따라 그 특성이 결정됨을 알 수 있었다. 관창의 유동특성과 예측 데이터로부터 화재진압의 효율성을 극대화할 수 있는 새로운 관창의 모델이 제시되었다. 본 연구의 결과가 새로운 모델의 관창을 개발하는데 필요한 자료로 활용할 수 있을 것으로 보며, 또한 관창의 원천기술 확보, 동종업계의 기술력 파급효과 증대 및 소방분야의 기술개발 활성화 등에 이바지하고 자 한다.

미세물분무 소화성능에 관한 연구 (A Study on the Performance of Water Mist Spray Fire Protection System)

  • 김봉환;김용판;문철진;홍철현;이형욱;최현호
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.572-578
    • /
    • 2003
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was attributed to the cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

나노 수산화알루미나를 이용한 건설소재의 내화성능 개선연구 (A Study on Performance of Building Material using nano-hydrated Aluminum for Fire-Resistance)

  • 조병완;박종빈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.826-829
    • /
    • 2004
  • An increasing interest in fire safety engineering can currently be identified in Korea and overseas. The fire-resistant characteristics of spray coating material for fire protection with or without nano $Al(OH)_3$ colloid has been experimentally investigated and the results are presented in this paper. The fire-resistance characteristics of spray coating material with nano $Al(OH)_3$ were superior to those without $Al(OH)_3$. Especially, spray coating material with nano material showed that thermal characteristic in the early days was remarkably excellent.

  • PDF

화재용 중저압 물분무 노즐의 분무특성에 관한 연구 (A Study on Spray Characteristics of Water Mist Nozzle with Mid-low Pressure for Fire Suppression)

  • 김성찬;유홍선;박현태;방기영
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.28-32
    • /
    • 2003
  • The present study investigates the spray characteristics of water mist nozzle with mid-low pressure for fire suppression. The examined nozzle types are swirl and spiral nozzle. The result shows that K factor of water mist nozzle is much smaller than those of general sprinkler. Spray angle of spiral nozzle is largest and more than $150^{\circ}$. SMD(Sauter Mean Diameter) of water mist nozzles is ranged between 100 and 200$\mu\textrm{m}$through measuring by image processing method. The spray pattern of spiral nozzle represent that water flux of first stream is 2 times larger than that of second stream. This study will contribute better understandings of the water-mist spray characteristics and useful daia for developing the water-mist nozzles.

소화노즐의 분무특성에 대한 설계 변수 영향의 수치해석적 연구 (Numerical Study on the Effects of Design Parameters on the Spray Characteristics of Fire Suppression Nozzles)

  • 이창효;최병일;한용식;김창;정희택
    • 한국분무공학회지
    • /
    • 제11권4호
    • /
    • pp.199-204
    • /
    • 2006
  • Numerical investigation has been performed to simulate the spray characteristics in mist-spray fire suppression nozzles in sense of design parameters. Two key shape factors in nozzle orifices. i.e. diameter and length are chosen as simulation parameters. Commercial softwares, FLUENT and FDS with the proper modelings were applied as numerical tools. Main performances of nozzles, i.e., K-factors, spray angles, droplet size, jet velocities and fire suppression time are analyzed for each parameter to find optimal design conditions.

  • PDF

스프링클러 분무가 화재유동특성에 미치는 영향에 관한 수치해석 연구 (A Numerical Study of the Effect of Sprinkler Spray on the Flow Characteristics Induced by Fire)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.105-110
    • /
    • 2012
  • 본 연구는 수치적 접근방법을 통해 스프링클러 분무가 화재공간내부 유동특성에 미치는 영향을 파악하고자 한다. 화재유동 및 분무유동장 해석을 위해 적용된 수치해석모델은 FDS 5.5.3이며 격자독립성시험을 통해 최적 격자를 선정하였다. 수치해석 모델의 타당성을 검증하기 위해 Magnone 등이 수행한 실험결과와 비교 분석을 수행하였으며 FDS 모델에 의해 계산된 화재공간 내부의 온도분포는 실험결과와 비교적 잘 일치하였으나 스프링클러 분사유량이 증가함에 따라 오차는 증가하는 경향을 보였다. 또한 이전 연구와 같이, FDS 계산결과는 스프링클러 분무에 의해 화재실 출입구를 통한 연소생성물의 유출질량유량이 감소하는 것으로 나타났다. 본 연구는 스프링클러 분무가 포함된 화재유동장에 대한 모델의 타당성을 확보하고 스프링클러 시스템의 최적화에 기여할 수 있다.

소화용 스프링클러 헤드의 살수분포 및 수적 특성에 대한 연구 (The Study on Characteristics of Water Spray and Droplet from Fire Sprinkler Head)

  • 추병길;최종욱;차경세
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.13-21
    • /
    • 2001
  • The effect of water spray for the fire sprinkler depends on droples distribution over maximum possible floor area. The present study are carried out for the characteristics of water spray and droplets experimentally and numerically km two fire sprinkler heads which are CHM head and CHl heal CHl head is self-production and CHl head is widely used up to date. As the result of using CHM head, water spray and droplets are distributed over large area because CHM head has smooth surface and non-flamed shape. When the pressure of fire sprinkler head is low, SMD(sauter mean diameter) is large and when the pressure of fire sprinkler head is high, SMD is small.

  • PDF