• Title/Summary/Keyword: Spray Tower

Search Result 26, Processing Time 0.029 seconds

A Study on the Performance of Heat Exchanger for Closed Cooling Tower (밀폐식 냉각탑용 열교환기의 성능에 관한 연구)

  • Lee, Sang-Sik;Yoo, Seong-Yeon;Kim, Jin-Hyuck;Ahn, Young-Hwan;Park, Hyoung-Joon;Ryu, Hae-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.334-339
    • /
    • 2008
  • An closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The purpose of this study is to evaluate thermal performance of heat exchanger at various conditions and to provide design datebase. The experimental study regarding heat exchanger for closed cooling tower was conducted. Experimental apparatus consists of constant temperature bath, water pump, spray nozzle, heat exchanger, fan, and date acquisition system. Heat transfer rates at various air velocitys, water flow rates, two different spray modes were measured and heat transfer coefficient were calculated to compare the thermal performances. This study provides that the heat transfer coefficient increases with increasing spray water flow rate and with increasing air velocity. The wet mode was more effective than dry mode for closed cooling tower to this study.

  • PDF

Collection Efficiency Enhancement of Spray Tower Scrubber by Introducing Electrospray with Two-flow Nozzle (분무탑식 스크러버에서 이류체 정전분무에 의한 집진효율의 향상)

  • Hwang, You-Seong;Kim, Jong-Ho;Kim, Jong-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.339-345
    • /
    • 2010
  • There have been a number of efforts to satisfy national emission regulations and reduce the amount of emitted air pollutants. There are several air pollution control devices, however, only wet scrubber is efficiently used to remove particulate matters and gaseous pollutants, even if it has minimum collection efficiency in the particle size range of $0.1{\sim}1{\mu}m$. This study aimed to improve the collection efficiency of a spray tower type scrubber by introducing an electrospray system with two-flow nozzle. We found that the collection efficiency of a spray tower type scrubber was similar to that of a conventional wet scrubber. However, installation of an electrospray system in the scrubber resulted in drastic further improvement of collection efficiency comparing to that of a conventional scrubber, which is 26%, 35.2%, and 45.1% at the liquid to gas ratio of 0.26 $L/m^3$ and 19.9%, 35.1%, and 42.5% at 0.34 $L/m^3$ for the applied voltage of -30 kV, -35 kV, and -40 kV, respectively. Therefore, we found that the introduction of an electrospray system is very effective to improve the collection efficiency of a spray tower type scrubber.

Thermal Performance Characteristics of Closed-Wet Cooling Tower (밀폐형 냉각탑의 열성능 특성에 관한 실험적 연구)

  • Sarker, M.M.A.;Kim, E.P.;Moon, C.G.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.88-92
    • /
    • 2005
  • The experiment of thermal performance about closed-wet cooling tower was conducted in this study. A closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from the top of the heat exchanger to the bottom side in the inner part of the tube, and spray water flows in the gravitational direction in the outer side. Air comes in direct contact with the spray water at the outer side of the tube while passing from the lower the upper part having a counterflow to the spray water. The heat transfer pipe used in this experiment is a bare-type tube having an outer diameter of 15.88mm. The heat exchanger is consisted of seven rows and fifteen columns. In this experiment, thermal performance of the cooling tower is derived from overall heat transfer coefficients between the process fluid and sprayed water and volumetric overall mass transfer coefficient between sprayed water and air.

  • PDF

A Study on the Factors of affecting the Heat Exchanger for Closed Cooling Tower (밀폐형 냉각탑용 열교환기의 성능에 영향을 미치는 인자에 관한연구)

  • Lee, Sang-Sik;Yoo, Seong-Yeon;Kim, Jin-Hyuck;Ryu, Hae-Sung;Park, Hyoung-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.250-255
    • /
    • 2008
  • Most high-rise building and large building require a cooling tower. Closed cooling tower is a low noise and the high efficiency. also Closed cooling tower is available for four season. Performance of Closed cooling tower is judged by heat transfer coefficient. In this study, Heat transfer coefficient is compared with air velocity, spray flow, heat exchanger type.

  • PDF

Experimental Study on the Enhancement of Particle Removal Efficiency in Spray Tower Scrubber Using Electrospray

  • Kim, Hyeok-Gyu;Kim, Hong-Jik;Lee, Myong-Hwa;Kim, Jong-Ho
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.2
    • /
    • pp.89-95
    • /
    • 2014
  • There have been a lot of efforts to keep permissible emission standards and to reduce the amount of emitted air pollutants. There are several air pollution control equipments, however, wet scrubber is used to remove particulate matters and gaseous pollutants simultaneously, even if it has low collection efficiency in the particle size less than $5.0{\mu}m$. To overcome this problem, we introduced a spray tower scrubber with an electrospray system which a high voltage was indirectly applied. We found that collection efficiency of fine particles in the electrospray system was improved by increasing electrical field strength and the ratio of liquid-gas flow rate (from 41% to 84% for $0.3{\mu}m$ particles). In addition, a number of small droplets generated from an electrospray system led high collection efficiency, resulting from electrostatic attraction between droplets and particles and higher collision frequency. Therefore, we can conclude that the introduction of an electrospray system is quite effective to increase the particle removal efficiency of a spray tower scrubber.

An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube (베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구)

  • Jun, Chul-Ho;Lee, Ho-Saeng;Moon, Choon-Geun;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

A Study on the Emission and Dispersion of Particulate Matter from a Cement Plant (한 시멘트공장의 분진발생과 대기확산에 관한 조사연구)

  • Chang, Man-Ik;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.67-77
    • /
    • 1983
  • To investigate the an air pollution by particulate matter and its dispersion, a cement plant produceing portland cement 600,000 ton/year and its vicinity were surveyed from Obtober, 1980 to April, 1983. The survey was mainly focused on main stack emmission rate of the cement plant and particle size distribution in the dust, dustfall and total suspended particulate concentration in the area by month and distance from the stack. The results of the study were as follows; 1. The main stack emission rate was surveyed before and after the spray tower was additionally installed to the original E.P bag filter. Before the spray tower installed, the main stack emission rate was higher ($0.64g/Nm^3$) than the emission standard of Korean Environmental Preservation Law's ($0.59g/Nm^3$, amended to $0.4g/Nm^3$ on April 1983), but after the spray tower was installed, its main stack emission rate was markedly decreased to the standard ($0.43g/Nm^3$). 2. $2{\sim}3{\mu}m$ of the particle size was the largest portion (20.8%) of the dust particulate from the main stack and 50% of the frequency distribution was $1.5{\mu}m$ of the size. Most particle size was below $10{\mu}m$. 3. The spray tower reduced the dustfall to $37.81{\sim}9.76\;ton/km^2/month$ while dustfall appeared at $45.29-15.45ton/km^2/month$, in the vicinity of plant before spray tower installed 4. Mean concentrations of total suspended particulate for 24 hours of the various stations were determined in $20.6-200.0{\mu}g/m^3$, 3 stations of tham were higher than the value of Harry and William's arthmetic average standard $130{\mu}g/m^3$. 5. Linear regression between dustfall [X] and total suspended particulate[Y] concentration was an equation, Y=4.024X+11.479.[r=0.91] 6. During the whole seasons in the opposite area 100m apart from the omission source the prevailing wind direction was with estimated more than $30ton/km^2/month$, and the concentration of total suspended particulate for 24 hours averaging time was more than $140{\mu}g/m^3$ in the same area and direction. 7. Assuming the wind direction were constant through the day dustfalls for a day were estimated at $13.40ton/km^2/day,\;10.79ton/km^2/day$ and $4.55ton/km^2/day$ at various distances of 100m, 500m and 1,500m from the emission source respectively. 8. In the simutalion of dustfall and suspended dust by area, Gaussian dispersion model modified by size distribution of particulate matter was not applicated since the emission of dust were from multi sources other them stack. From the above results, it could be applied that the dispersion of dust from the cement plant is estimated and regulated for the purpose of environmental protection.

  • PDF

Selection of low toxic insecticides for phytoseiid predatory mites, Amblyseius cucumeris and Amblyseius fallacis (Amblyseius cucumeris 및 Amblyseius fallacis에 대한 저독성약제 선발)

  • Choi, Byeong-Ryeol;Hilton, S.A.;Broadbent, A.B.
    • The Korean Journal of Pesticide Science
    • /
    • v.7 no.4
    • /
    • pp.296-301
    • /
    • 2003
  • This study was conducted to select low toxic insecticides against natural enemies, and to evaluate resistance stability and cross-resistance to resistance strain for the fulfillment of integrated pest management development. Toxicity of imidacloprid and spinosad to Amblyseius cucumeris was relatively low regardless of the adopting test methods. In addition, those to the Amblyseius fallacis was also low by slide dipping method. The slide dipping method was useful to eliminate repellency effect by mites to the tested insecticides. Mortality of A. fallacis to deltamethrin recorded in 1994 and 1999 was 21.6% and 7.4%, respectively. Meanwhile, the permethrin-resistanct strain of A. fallacis was maintained its resistance to deltamethrin. However, the cross-resistance to the newly introduced insecticides namely imidacloprid, fipronil, chlorfenapyr, abamectin, and spinosad. was relatively low.

Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater (축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.