• 제목/요약/키워드: Spray Test

검색결과 857건 처리시간 0.025초

담수화 설비 스프레이 노즐에 대한 실험적 연구 (An Experimental Study of Spray Nozzle Desalination Facility)

  • 신현경;주현태;박민호;박경민;김진영;임진영
    • 한국해양공학회지
    • /
    • 제20권1호
    • /
    • pp.26-31
    • /
    • 2006
  • Experimental research was undertaken to develop a domestic spray nozzle used on equipment for desalination. First, we made a test set-up in order to confirm nozzle efficiency of spray and distribution under different pressure conditions. Then, we found a maximum spray condition after verifying reliability of this facility. An optimum arrangement of the nozzle, based on the test result, was made using CATIA V5 and EXCEL.

다구찌 기법을 이용한 용사코팅의 공정 최적화 (Optimization for Thermal spray Process by Taguchi Method)

  • 김균택;김영식
    • 동력기계공학회지
    • /
    • 제16권2호
    • /
    • pp.54-59
    • /
    • 2012
  • In the present study, process optimization for thermal-sprayed Ni-based alloy coating has been performed using Taguchi method and analysis of variance(ANOVA). Ni-based alloy coatings were fabricated by flame spray process on steel substrate, and the hardness test and wear test were performed. Experiments were designed as per Taguchi's L9 orthogonal array and tests were conducted with different Oxygen gas flow, Acetylene gas flow, Powder feed rate and Spray distance. Multi response signal to noise ratio (MRSN) was calculated for the response variables and the optimum combination level of factors was obtained simultaneously using Taguchi's parametric design.

Gaussian 액적 크기 분포 함수를 이용한 분무형 화재 현상 해석 (Analysis of Sodium Spray Fire Using Gaussian Droplet Size Distribution)

  • 김병호;한도희;서숭혁
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.72-81
    • /
    • 2004
  • Study on the analysis of sodium spray fire using Gaussian drop size distribution, which redistributes a droplet spectrum with given mean diameter if its size classes with critical diameter(D>8mm) occur, was carried out. In this case, the oversized droplets were reduced to a stable diameter. Results calculated by the code using Gaussian drop size distribution were in better agreement with AI experimental results than those of NACOM and SPRAY code. The effect of variance on pressure in the test cell appeared greatly by introducing Gaussian function, which could represent various sodium droplet size distribution. The increase of the variance with mean droplet size resulted had an important effect upon the pressure in the test cell.

An Experimental Study of the Micro Turbojet Engine Fuel Injection System

  • Choi, Hyun-Kyung;Choi, Seong-Man;Lee, Dong-Hun
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.1-5
    • /
    • 2008
  • An experimental study was performed to develop the rotational fuel injection system of the micro turbojet engine. In this system, fuel is sprayed by centrifugal forces of engine shaft. The test rig was designed and manufactured to get droplet information on combustion space. This experimental apparatus consist of a high speed rotational device(Air-Spindle), fuel feeder, rotational fuel injector and acrylic case. To understand spray characteristics, spray droplet size, velocity and distribution were measured by PDPA (Phase Doppler Particle Analyzer) and spray was visualized by using Nd-Yag laser-based flash photography. From the test results, the length of liquid column from injection orifice is controlled by the rotational speeds and Sauter Mean Diameter(SMD) is decreased with rotational speed. Also, Sauter Mean Diameter is increased as increasing mass flow rate at same rotational speeds.

  • PDF

Characteristics of Droplet Properties in the Two-Phase Spray into a Subsonic Cross Flow

  • Lee, I.C.;Cho, W.J.;Koo, J.Y.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.358-363
    • /
    • 2008
  • The spray cross-section characteristics of two-phase spray that using external-mixing nozzle injected into a subsonic cross flow were experimentally studied with various ALR ratio that is $0{\sim}59.4%$. Suction type wind tunnel was used and experiments were conducted to ambient environment. Several plain orifice nozzles with L/d of 30 and orifice diameter of 0.5 mm and orifice length 1.5 mm were tested. Free stream velocity profiles at the injection location were measured using hot wire. Spray images were captured to study collision point and column trajectory. Phase Doppler particle analyzer(PDPA) was utilized to quantitatively measuring droplet SMD, volume flux. Measuring probe of PDPA positions was moved 3-way transverse machine. SMD distributions were layered structure and peaked at the top of the spray plume and low value at bottom of the spray. Volume flux of spray was distributed to the two side region and volume flux quantity decreased when ALR ratio increased. It was found that the perpendicularly injected two-phase spray jet of external mixing into a cross flow showing that mistlike spray moved away from the test section bottom region.

  • PDF

속경성 바인더 유형에 따른 긴급보수용 스프레이 패칭 상온 재활용 아스팔트 혼합물(RAP)의 성능 평가 (Performance Evaluation of 100 % RAP Asphalt Mixtures using different types of Rapid-Setting Polymer-Modified Asphalt Emulsion for Spray Injection Application)

  • 김두열;전지성;이상염;이석근;권봉주
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.75-85
    • /
    • 2017
  • PURPOSES : The purpose of this study was to determine the optimum mix design of the content of 100 % reclaimed asphalt pavement (RAP) for spray injection application with different binder types. METHODS : Literature review revealed that spray injection method is the one of the efficient and economical methods for repairing a small defective area on an asphalt pavement. The Rapid-Setting Polymer modified asphalt mixtures using two types of rapid setting polymers-asphalt emulsion and a quick setting polymer asphalt emulsion-were subjected to the following tests to determine optimum mix designs and for performance comparison: 1) Marshall stability test, 2) Retained stability test, 3) Wet track abrasion test, and 4) Dynamic stability test. RESULTS and CONCLUSIONS : Type A, B, and C emulsions were tested with different mix designs using RAP aggregates, to compare the performances and determine the optimum mix design. Performance of mixtures with Type A emulsion exceeded that of mixtures with Type B and C emulsion in all aspects. In particular, Type A binder demonstrated the highest performance for WTAT at low temperature. It demonstrated the practicality of using Type A mixture during the cold season. Furthers studies are to be performed to verify the optimum mix design for machine application. Differences in optimum mix designs for machine application and lab application will be corrected through field tests.

The Effect of $Bi(OH)_3$ on Corrosion-Resistant Properties of Automotive Epoxy Primers

  • Yang, Wonseog;Min, Sungki;Hwang, Woon-suk
    • Corrosion Science and Technology
    • /
    • 제7권6호
    • /
    • pp.370-374
    • /
    • 2008
  • In this study, we evaluated anti-corrosion properties of both commercial unleaded and lead epoxy primer for automotive substrate before applying to actual painting lines by salt spray test, and cyclic corrosion test, potentiodynamic test and electrochemical impedance spectroscopy. The difference in the corrosion resistance between automotive epoxy primers contained $Bi(OH)_{3}$ and leaded one was investigated. And it was also discussed the effect of zinc phosphate pretreatment to the epoxy primers. The specimen coated epoxy primer contained $Bi(OH)_{3}$ showed 0.5 V higher corrosion potential than that of bare steel. The result of salt spray test did not indicate remarkable difference of corrosion resistance in all specimens above $10{\mu}m$ thickness up to 1200 hours. In the cyclic corrosion test, epoxy primers contained $Bi(OH)_{3}$ on phosphated substrate performed good corrosion properties until 800 hours. The epoxy primer contained $Bi(OH)_{3}$ performed the equivalent corrosion resistance as leaded coating on phosphated steel, but slightly inferior to that of leaded on bare steel. These results show that the pre-treatment of zinc phosphate is effective as well as pigment changing in performing anti-corrosion properties in automotive bodies.

나트륨 화재 특성의 실험적 연구 (An Experimental Study on the Characteristics of Sodium Fires)

  • Bae, Jae-Heum;Ahn, Do-Hee;Kim, Young-Cheol;Mann Cho
    • Nuclear Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.471-483
    • /
    • 1994
  • 시험용기가 1.7㎥가 되는 소규모 나트륨화재 실험 시설을 건설하여 나트륨 관련시설에서 발생가능한 풀형화재, 분무형화재, 그리고 원주형화재와 같은 나트륨화재 실험을 실시하였다. 그 결과 풀형화재는 나트륨 주입량에 비하여 온도 및 압력 증가치가 분무형화재와 원주형화재보다 훨씬 작지만 상당기간 나트륨풀과 용기안의 온도를 높게 유지시키며 나트륨 주입량이 많을 경우 용기내의 산소를 거의 소모시켜 용기안의 산소농도를 0mol%에 근접시키고 진공 상태까지 이르게 하였다. 분무형화재는 분산된 작은 나트륨이 순간적으로 산소와 반응하여 급격히 용기내의 온도와 압력을 증가시키며 곧 감소하였다. 분무형 화재의 최고 도달온도와 압력은 초기 산소농도 그리고 나트륨 주입온도에 따라 크게 다름을 보여 주었다. 원주형화재는 분무형화재와 거의 유사하지만 좀 더 많은 양의 나트륨을 시험용기내에 주입시켜도 최고 도달 온도와 압력이 분무형보다 작았다. 그리고 분무형화재와 원주형화재에서는 풀형화재에 비하여 순간적으로 분산된 나트륨이 산화하여 용기내의 측정위치에 따라 온도분포가 크게 다름을 보여주었다. 끝으로, 풀형화재 소화실험에서는 소화제 graphex가 효과적으로 나트륨 화재를 진화시킬 수 있음을 확인하였다.

  • PDF

A comparative evaluation of peppermint oil and lignocaine spray as topical anesthetic agents prior to local anesthesia in children: a randomized clinical trial

  • Harika Petluru;SVSG Nirmala;Sivakumar Nuvvula
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제24권2호
    • /
    • pp.119-128
    • /
    • 2024
  • Background: In pediatric dentistry, fear and anxiety are common among children. Local anesthetics (LA) are widely used to control pain and reduce discomfort in children during dental treatment. Topical anesthetics play a vital role in reducing pain and the unpleasant sensation of a needle puncture in children. Peppermint oil has been extensively used for various diseases. However, its anesthetic properties remain unknown. Peppermint oil, used in mouthwashes, toothpastes, and other topical preparations has analgesic, anesthetic, and antiseptic properties. This study aimed to compare and evaluate pain perception following the topical application of peppermint oil versus lignocaine spray before an intraoral injection in children, aged 8-13 years. Method: Fifty-two children, aged between 8-13 years, who required local anesthesia for dental treatment were divided into two groups of 26 each by simple random sampling (Group 1: 0.2% peppermint oil and Group 2: lignocaine spray). In both groups, physiological measurements (e.g., heart rate) were recorded using pulse oximetry before, during, and after the procedure. Objective pain measurement (Sound Eye Motor (SEM) scale) during administration and subjective measuremeant (Wong-Baker Faces Pain Rating Scale (WBFPRS)) after LA administration were recorded. This was followed by the required treatment of the child. Physiological parameters were compared between the two groups using an independent t-test for intergroup assessment and a paired t-test and repeated-measures ANOVA for intragroup comparisons. The Mann-Whitney U test was used to analyze the pain scores. Results: Intragroup mean heart rates, before, during, and after treatment were statistically significantly different (P < 0.05). However, the intergroup mean pulse rates did not differ significantly between the two groups. The mean WBFPS score in the lignocaine spray group was 4.133 ± 2.06 was statistically different from that of the peppermint oil group (0.933 ± 1.03; P < 0.001*). The mean SEM score was significantly lower in the peppermint oil group than that in the lignocaine spray group (P = 0.006). No negative effects were observed in this study. Conclusion: 0.2% peppermint oil was effective in reducing pain perception.

분무액적과 벽의 상호작용에 대한 연구 (Study of Spray Droplet/Wall Interaction)

  • 양희천;유홍선;정연태
    • 한국자동차공학회논문집
    • /
    • 제6권4호
    • /
    • pp.86-100
    • /
    • 1998
  • The impingement of the fuel spray on the wall within the combustion chamber in compact high-pressure injection engines and on the intake port wall in port-fuel-inje- ction type engines is unavoidable. It is important to understand the characteristics of impinging spray because it influences on the rate of fuel evaporation and droplet distrib- ution etc. In this study, the numerical study for the characteristics of spray/wall interaction is performed to test the applicability and reliability of spray/wall impingement models. The impingement models used are stick model, reflect model, jet model and Watkins and Park's model. The head of wall-jet eminating radilly outward from the spray impingement site contains a vortex. Small droplets are deflected away from the wall by the stagnation flow field and the gas wall-jet flow. While the larger droplets with correspondingly higher momentum are impinged on the wall surface and them are moved along the wall and are rolled up by wall-jet vortex. Using the Watkins and Park's model the predicted results show the most reasonable trend. The rate of increase of spread and the height of the developing wall-spray is predicted to decrease with increased ambient pressure(gas density).

  • PDF