• Title/Summary/Keyword: Spot size

Search Result 547, Processing Time 0.031 seconds

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF

Super Resolution Readout in Near Field Optical Data Storage System (근접장 광 기록 재생 시스템에서의 초해상 재생 현상 확인)

  • Lee, Jin-Kyung;Jeong, An-Sik;Shin, Jong-Hyun;Kim, Joo-Ho;Lee, Kyung-Geun;Kim, Joong-Gon;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Super-resolution near-field structure (super-RENS) technology and solid immersion lens (SIL) based near-field (NF) technology have been expected as promising approaches to increase data capacity or areal density of optical disc. Super-RENS technology has been studied until now using mainly numerical aperture (NA) of 0.85 far-field optical system and possibility of tangential data density increment have been presented. NF technology has been studied with NA over 1 and presented demonstration of removable performance. To achieve much higher density, approach to increase NA of super-RENS by NF technology (Near-Field Super-Resolution, NFSR) can be a candidate and we think this technology would be advantageous compared to wavelength reduction or much higher NA increment of NF technology or much smaller effective optical spot size reduction of far-field super-resolution technology. In this paper we present readout result of ROM media having monotone pits using NF optical system with wavelength of 405nm and NA of 1.84 surface type SIL. GeSbTe material was used for super resolution active layer and pit length is 37.5nm which is shorter than resolution limit 55nm. We present the feasibility of NFSR technology by confirming the CNR threshold according to readout power (Pr) and CNR 33dB over threshold Pr.

  • PDF

Community Characteristics of Benthic Macroinvertebrates according to Growth Environment at Rural Palustrine Wetland (농촌지역 소택형습지의 생육환경에 따른 저서성대형무척추동물 군집 특성)

  • Son, Jin-Kwan;Kim, Nam-Choon;Kim, Mi-Heui;Kang, Banghun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.5
    • /
    • pp.129-144
    • /
    • 2012
  • This study was conducted to understand the community characteristics of benthic macroinvertebrates according to Growth Environment at 6 Palustrine Wetlands in a rural area. As growth environment factors, size, water depth, water inlet and water outlet, land-use and water environment was analyzed. Two years' quantitative collection of benthic macroinvertebrate was carried out, and it executed community analysis and ESB index calculation and also carried out twinspan, MDS and correlation analysis. As a result, the collected benthic macroinvertebrate was 1254 individuals with 3 Phylums, 6 Classes, 14 Orders, 35 Families, 52 Genera and 61 Species. Odonata and Coenagreionidae had the highest species and individuals. Dominance Index was 0.252~0.698, Diversity Index was 1.661~2.902, Evenness Index was 0.414~0.724, and Species Richness Index was 1.990~6.224. As a result of community analysis, when correlation analysis was executed, Dominance Index had the opposite tendency with Diversity Index and Evenness Index, which had the same tendency with the previous studies. When ESB Index was calculated, Grade 2 (polluted) had the highest species with 48 species (78.7%). It is determined from the Environmental quality evaluation and saprobity evaluation result according to ESB index that there is a need to revise environmental evaluation system more specifically. As a result of MDS analysis, the subject spots A and D had the highest similarity, and the subject spot E and D had a relatively high similarity. The life environment that is the closest related with species diversity is estimated by the land-use. As for number of Individual, it seems to have the closest relation with inlet, which is to be determined as a characteristics of Palustrine Wetland. Through such investigation, this study is expected to be utilized for various types of habitats including ecological pond and to be utilized for the increase of species diversity in rural areas.

SOA-Integrated Dual-Mode Laser and PIN-Photodiode for Compact CW Terahertz System

  • Lee, Eui Su;Kim, Namje;Han, Sang-Pil;Lee, Donghun;Lee, Won-Hui;Moon, Kiwon;Lee, Il-Min;Shin, Jun-Hwan;Park, Kyung Hyun
    • ETRI Journal
    • /
    • v.38 no.4
    • /
    • pp.665-674
    • /
    • 2016
  • We designed and fabricated a semiconductor optical amplifier-integrated dual-mode laser (SOA-DML) as a compact and widely tunable continuous-wave terahertz (CW THz) beat source, and a pin-photodiode (pin-PD) integrated with a log-periodic planar antenna as a CW THz emitter. The SOA-DML chip consists of two distributed feedback lasers, a phase section for a tunable beat source, an amplifier, and a tapered spot-size converter for high output power and fiber-coupling efficiency. The SOA-DML module exhibits an output power of more than 15 dBm and clear four-wave mixing throughout the entire tuning range. Using integrated micro-heaters, we were able to tune the optical beat frequency from 380 GHz to 1,120 GHz. In addition, the effect of benzocyclobutene polymer in the antenna design of a pin-PD was considered. Furthermore, a dual active photodiode (PD) for high output power was designed, resulting in a 1.7-fold increase in efficiency compared with a single active PD at 220 GHz. Finally, herein we successfully show the feasibility of the CW THz system by demonstrating THz frequency-domain spectroscopy of an ${\alpha}$-lactose pellet using the modularized SOA-DML and a PD emitter.

Consumer's Recognition, Nutrient Composition, and Safety Evaluation of Commercial Sunsik and Saengsik (시판 선식.생식 제품에 대한 소비자 인식 조사와 영양성분 및 위생안전성 분석에 관한 연구)

  • Chung, Sun-Soon;Han, Young-Sil
    • Journal of the Korean Society of Food Culture
    • /
    • v.18 no.3
    • /
    • pp.235-243
    • /
    • 2003
  • This study was to investigate the consumer recognition of commercial Sunsik & Saengsik. The data was collected from the 395 married women residing in Seoul and Kyungki area by the self-administered questionnaire. A related purpose was to analyze the nutrient composition and the hygienic safety of commercial Sunsik and Saengsik. The results from this study were as follows. The purchasing and using behaviors were significantly different between two user groups. Sunsik users have generally purchased the products at a discount store(41.0%) as a between-meal snack(36.4%). The products were usually the ones made on the spot(55.0%). However, Saengsik users have purchased the manufactured products-serving size package-(84.0%) at a health foods store(50.7%) as a health food(38.7%). Many of Sunsik users have had Sunsik in water or milk with sugar(40.7%) and 1-2 times a week(40.0%). But Saengsik users have usually had Saengsik in water or milk with honey(38.6%) and everyday(34.7%). According to the analysis on nutrition composition, crude proteins were significantly more rich in Sunsik samples, and crude ashes were more rich in Saengsik samples(p<0.01). Sunsik E and all the Saengsik samples showed the high total viable plate counts of $4.8{\sim}7.0$ log cfu/g. Coliform groups were detected in all the Saengsik and two Sunsik(A, E) samples.

The Effect of Diaphragm inside Trough Rib on Fatigue Behavior of Trough Rib and Cross Beam Connections in Orthotropic Steel Decks (강바닥판 종리브와 횡리브 교차부의 피로거동에 대한 종리브내 다이아프램의 영향)

  • Choi, Dong Ho;Choi, Hang Yong;Choi, Jun Hyeok
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.3 s.46
    • /
    • pp.239-250
    • /
    • 2000
  • This study investigates the mechanical behavior on trough rib to crossbeam joint in orthotropic steel plate decks, specially emphasizing on the effect of diaphragm inside trough rib on the fatigue behavior of slit by static and fatigue tests. In particular, the effects of diaphragm on in-plane stress and out-of-plane stress, stress concentration, propagation of fatigue cracks at the silt are studied. With the result of experiment and numerical analysis, we have estimated the fatigue strength using the nominal stress and hot-sport stress. The details with diaphragm have occurred about 50% stress reduction at trough rib part of trough rib to crossbeam joint than the detail without diaphragm, however, the lower parts of crossbeam have occurred much more stress. Initial crack size or slit have an considerable influence on the propagation of fatigue cracks due to V-notch. The fatigue strength category of the details without diaphragm has higher value than fatigue limit, whereas that of the details with diaphragm is estimated lower than fatigue limit.

  • PDF

Spatial Analysis of Nonpoint Source Pollutant Loading from the Imha dam Watershed using L-THIA (L-THIA를 이용한 낙동강수계 임하댐유역 비점오염원의 공간적 분포해석)

  • Jeon, Ji-Hong;Cha, Daniel K.;Choi, Donghyuk;Kim, Tae-Dong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.1
    • /
    • pp.17-29
    • /
    • 2013
  • Long-Term Hydrologic Impact Assessment (L-THIA) model which is a distributed watershed model was applied to analyze the spatial distribution of surface runoff and nonpoint source pollutant loading from Imha watershed during 2001~2010. L-THIA CN Calibration Tool linked with SCE-UA was developed to calibrate surface runoff automatically. Calibration (2001~2005) and validation (2006~2010) of monthly surface runoff were represented as 'very good' model performance showing 0.91 for calibration and 0.89 for validation as Nash-Sutcliffe (NS) values. Average annual surface runoff from Imha watershed was 218.4 mm and Banbyun subwatershed was much more than other watersheds due to poor hydrologic condition. Average annual nonpoint source pollutant loading from Imha wateshed were 2,295 ton/year for $BOD_5$, 14,752 ton/year for SS, 358 ton/year for T-N, and 79 ton/year for T-P. Amount of pollutant loading and pollutant loading rates from Banbyun watershed were much higher than other watersheds. As results of analysis of loading rate from grid size ($30m{\times}30m$), most of high 10 % of loading rate were generated from upland. Therefore, major hot spot area to manage nonpoint source pollution in Imha watershed is the combination of upland and Banbyun subwatershed. L-THIA model is easy to use and prepare input file and useful tool to manage nonpoint source pollution at screening level.

A study on the fabrication and processing of ultra-precision diamond tools using FIB milling (FIB milling을 이용한 고정밀 다이아몬드공구 제작과 공정에 관한 연구)

  • Wi, Eun-Chan;Jung, Sung-Taek;Kim, Hyun-Jeong;Song, Ki-Hyeong;Choi, Young-Jae;Lee, Joo-Hyung;Baek, Seung-Yup
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.56-61
    • /
    • 2020
  • Recently, research for machining next-generation micro semiconductor processes and micro patterns has been actively conducted. In particular, it is applied to various industrial fields depending on the machining method in the case of FIB (Focused ion beam) milling. In this study, intends to deal with FIB milling machining technology for ultra-precision diamond tool fabrication technology. Ultra-precision diamond tools require nano-scale precision, and FIB milling is a useful method for nano-scale precision machining. However, FIB milling has a problem of Gaussian characteristics that are differently formed according to the beam current due to the input of an ion beam source, and there are process conditions to be considered, such as a side clearance angle problem of a diamond tool that is differently formed according to the tilting angle. A series of process steps for fabrication a ultra-precision diamond tool were studied and analyzed for each process. It was confirmed that the effect on the fabrication process was large depending on the spot size of the beam and the current of the beam as a result of the experimental analysis.

Optimization of self-dispersible floating granule (UG) of flucetosulfuron and its herbicidal performance (Flucetosulfuron 수면부상형 입제의 최적화 및 제초효과)

  • Kim, Do-Soon;Kim, Tae-Young;Lee, Jong-Nam;Hwang, Ki-Hwan;Lee, Yong-Sang
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.1
    • /
    • pp.28-35
    • /
    • 2006
  • This study was conducted to optimize formulation factors of a self-dispersible floating granule of flucetoaulfuron that can be used at a low application volume (5 kg $ha^{-1}$). SPA and xanthan gum were selected as a binder because blending of them showed good granulation and floatation. Potassium chloride selected as a filler also showed good granulation, floatation and disintegration properties. Among wetters and dispersants, Surfynol 440 gave the best dispersibility The optimum granule size was determined to be 1.0 mm considering floating time and dispersibility. Flucetosulfuron was mixed with the blend of SPA and xanthan gum, potassium chloride, and Surfynol 440 and formulated as a floating self-dispersible granule at 1.0 mm in diameter. Indoor and outdoor field experiments showed that the floating granule of flucetosulfuron performed well, covering long range from the application spot up to 15 m in weed control. Therefore, this floating technology may be used for laborsaving herbicide formulation development and help to reduce workloads for herbicide application.

Simulation of an X-ray Fresnel Zone Plate with Nonideal Factors

  • Chen, Jie;Fan, Quanping;Wang, Junhua;Yuan, Dengpeng;Wei, Lai;Zhang, Qiangqiang;Liao, Junsheng;Xu, Min
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.9-15
    • /
    • 2020
  • Fresnel zone plates have been widely used in many applications, such as x-ray telescopes, microfluorescence, and microimaging. To obtain an x-ray Fresnel zone plate, many fabrication methods, such as electron-beam etching, ion-beam etching and chemical etching, have been developed. Fresnel zone plates fabricated by these methods will inevitably lead to some nonideal factors, which have an impact on the focusing characteristics of the zone plate. In this paper, the influences of these nonideal factors on the focusing characteristics of the zone plate are studied systematically, by numerical simulations based on scalar diffraction theory. The influence of the thickness of a Fresnel zone plate on the absolute focusing efficiency is calculated for a given incident x-ray's wavelength. The diffraction efficiency and size of the focal spot are calculated for different incline angles of the groove. The simulations of zone plates without struts, with regular struts, and with random struts are carried out, to study the effects of struts on the focusing characteristics of a zone plate. When a Fresnel zone plate is used to focus an ultrashort x-ray pulse, the effect of zone-plate structure on the final pulse duration is also discussed.