• Title/Summary/Keyword: Spot measurement

Search Result 234, Processing Time 0.031 seconds

Application of Phase-Shifting Method in Speckle Interferomtery to Measurement of Micro-Scale Displacement

  • Baek, Tae-Hyun;Kim, Myung-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.162-168
    • /
    • 2006
  • Speckle interferometry with phase-shifting method has been applied to measurement of micro-scale displacement through optical signal processing. Four-step phase-shifting method by PZT is used to measure out-of-plane displacement in spot-welded cantilever and results of optical experiments are comparable to those of FEM. Phase-shifting method using Fourier transform by PZT is applied to measurement of in-plane displacement on rectangular steel plate with a circular hole. The results of optical experiment agree well with theoretical calculation. New phase-shifting method in speckle interferometry has been implemented with a quarter wave plate. In-plane displacement of specimen is measured by the new phase-shifting method. Results of optical experiment show that the quarter wave plate can be used for phase-shifting method that is cheap and easy to use in speckle interferometry.

Program Development for Measurement and Analysis of Radio Propagation (무선 전파의 측정 및 분석을 위한 프로그램 개발)

  • 고거다;현재섭;강영진;송문규
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.314-317
    • /
    • 2003
  • In this paper, a measurement and analysis program is developed, that can be utilized to measure and analyze radio propagation characteristics. This program is able to control the measurement instruments including spectrum analyzer through a GPIB interface, and analyze the measured data to yield mean excess delay and RMS delay spread. The measured path loss can be compared with theoretical path loss in free space or inside tunnels. The measured and analyzed results can also be presented in the forms of graphs. As those tasks can be conducted on the measurement spot, this program is very helpful for performing and verifying measurements.

  • PDF

Chemically Aged Asian Dust Particles Proven by Traditional Spot Test and the Most Advanced micro-PIXE

  • Ma, Chang-Jin;Tohno, Susumu;Kang, Gong-Unn
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.114-123
    • /
    • 2016
  • A change in chemical compositions of Asian dust (AD) particles can dramatically alter their optical properties, cloud-forming properties, and health effects. The present study was undertaken to evaluate this aging of AD particles by means of two complementary methods (i.e., the traditional spot test and the most advanced micro-PIXE analytical technique) for single particle analysis. Size-classified particles were sampled at the rural peninsula of Korea (Byunsan, 35.37N; 126.27E) during AD event and non-AD period in 2004. Sulfate was principally enriched on the particles in the size range of $7.65-10.85{\mu}m$ collected during AD event. The average number fraction of coarse particles ($>2.05{\mu}m$) containing chloride was 16.2% during AD event. Relatively low particles containing nitrate compared to those containing sulfate and chloride were found in AD event. Micro-PIXE elemental maps indicated that a large number of AD particles were internally mixed with man-made zinc. The highest peaks of EC and OC concentrations were appeared at $0.01-0.43{\mu}m$ particle aerodynamic diameter. High EC concentration in $PM_1$ was might be caused by the Saemangeum Seawall Project that was being conducted during our field measurement.

Implementation of TFDR system with PXI type instruments for detection and estimation of the fault on the coaxial cable (동축 케이블의 결함 측정에 있어서 PXI 타입의 계측기를 이용한 개선된 TFDR 시스템의 구현)

  • Choe, Deok-Seon;Park, Jin-Bae;Yun, Tae-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.91-94
    • /
    • 2003
  • In this paper, we achieve implementation of a Time-Frequency Domain Reflectometry(TFDR) system through comparatively low performance(100MS/s) PCI extensions for Instrumentation(PXI). The TFDR is the general methodology of Time Domain Reflectometry(TDR) and Frequency Domain Reflectometry(FDR). This methodology is robust in Gaussian noises, because the fixed frequency bandwidth is used. Moreover, the methodology can get more information of the fault by using the normalized time-frequency cross correlation function. The Arbitrary Waveform Generator(AWG) module generates the input signal, and the digital oscilloscope module acquires the input and reflected signals, while PXI controller module performs the control of the total PXI modules and execution of the main algorithm. The maximum range of measurement and the blind spot are calculated according ta variations of time duration and frequency bandwidth. On the basis of above calculations, the algorithm and the design of input signals used in the TFDR system are verified by real experiments. The correlation function is added to the TDR methodology for reduction of the blind spot in the TFDR system.

  • PDF

A Study on the Correlation Between Nugget Diameter and Contact Diameter of Sheets by Electrode Force (點熔接 의 너깃지름 과 板間接觸지름 의 關聯性)

  • 송삼홍;김부동
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.3
    • /
    • pp.313-318
    • /
    • 1983
  • It is required in designing a spot welding to get in advance an estimated figure of nugget diameter. A method of estimating nugget diameter of low carbon steel sheets is suggested in tesms of utilizing elastic calculation in theory and of making a sectional observation of specimen of spot welding in experiment. The resultant findings are summarized as follows: 1) A contact diameter of sheet, 2.gamma.$_{o}$=d sub e/+(1.1)t, wheer de is the electrode tip diameter and t is the thickness of sheets. 2) The practical measurement of the nugget diameter reveals that $d_{n}$=(1.05) $d_{e}$+(0.9)t, and $d_{b}$ is less by 0.8-4.3% than 2.gamma.$_{o}$. 3) The more $d_{n}$ is as compared with t, the less the difference between a theoretical value and an experimental value is. 4) In the spot welding of thin steel sheets less than 3mm in thickness that are commonly used in sheet metal works, the contact diameter equals the nugget diameter. In this case, either the theoretical or experimental approach can be used for estimating the nugget diameter.meter.ter.r.

Correlation Between Lateral Photovoltaic Effect and Conductivity in p-type Silicon Substrates

  • Lee, Seung-Hoon;Shin, Muncheol;Hwang, Seongpil;Park, Sung Heum;Jang, Jae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1845-1847
    • /
    • 2013
  • The lateral photovoltaic effect (LPE) can be observed in semiconductors by irradiating a light spot position between electrodes on sample's surface. Because lateral photovoltaic voltage (LPV) is sensitively changed by light spot position, a LPE device has been tried as a position-sensitive detector. This study discusses the correlation between LPV and conductivity in p-type silicon and nano-structured Au deposited p-type silicon (nano-Au silicon), respectively. Conductivity measurement of the sample was carried out using the four-wire method to eliminate contact resistance, and conductivity dependence on LPV was simultaneously measured by changing the light irradiation position. The result showed a strong correlation between conductivity and LPV in the p-type silicon sample. The correlation coefficient was 0.87. The correlation coefficient between LPV and conductivity for the nano-Au silicon sample was 0.41.

Precision Measurement for Aircraft Alignment using Industrial Photogrammetry (산업사진측량을 이용한 항공기 얼라인먼트 정밀측정)

  • Jung, Sung-Heuk;Lee, Jae-Kee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.57-63
    • /
    • 2005
  • According to increasing of demand for high accurate and quick measuring technology, they became to interest in industrial photogrammetry that can satisfy with this needs. This study is examined O-2A aircraft to check the application of Industrial Photogrammetry technology. To measure the aircraft alignment, the check points marked on it were used without exact aircraft design data. And to check any deformation of its external original feature, Pro-spot system has been used.

Temperature Measurement of the Contact Surface by Using the Hot Spot (Hotspa을 이용한 접촉표면의 온도측정)

  • 정동윤
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.50-56
    • /
    • 1992
  • 공업재료의 표면은 수많은 돌기들로 구성되어 있으며 이러한 돌기들의 접촉으로 진실접촉이 이루어진다. 그러므로 마찰은 겉보기 접촉면적과는 무관하며 진실접촉면에서 일어난다. 표면의 한 돌기가 접촉면과 상대운동을 함으로 인하여 마찰열이 발생된다. 이러한 마찰에너지 발산의 결과로서 진실접촉면적 주위의 국부적인 표면 온도가 상승되며 따라서 표면의 평균온도가 상승된다. 이러한 표면온도를 결정하기 위한 이론적 및 실험적인 방법이 많이 제시되어왔다. 정적상태에서의 표면온도는 Block(1937)과 Jaeger(1942)에 의해 이론적으로 소개하였다. Jaeger는 열원의 위치와 상대적인 접촉운동 그리고 크기 및 경계조건 등의 특정한 조건 하에서 진실접촉점의 온도를 계산하였다. 이에 Bany와 Baber(1984)는 그들의 경계조건이 잘목 정의되었음을 지적하고 더욱 세분화된 경계조건으로 온도분포를 유도한 바 있다. Ling(1969)은 접촉점에서의 온도가 주변의 겉보기 접촉면적의 온도보다 훨씬 높다는 것을 수치해석으로 밝혀냈다. 본 연구는 고속정밀촬영기를 이용하여 진실접촉점에서 발생하는 Hot spot의 온도분포를 실험을 통하여 규명하고 그 결과를 Geoim과 Winer의 이론식에 적용하므로 식의 유용성을 검증하는데 그 목적이 있다.

  • PDF

Development of the non contact tongue moisture measuring device (비접촉식 설면 습윤도 측정 기구의 개발)

  • Kim, Dae-Bok;Park, Yu-Gyung;Kim, Ki-Wang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.67-74
    • /
    • 2010
  • Objectives: Tongue moisture is one of major features in tongue diagnosis of Oriental Medicine. But with regard to the methods to qualify the tongue moisture level, there have been no adequate modalities to satisfy clinicians' needs. So we developed an novel device and method to quantify the tongue moisture level without contact. Methods and Materials: Ratio of saturated area to total tongue area in the image captured with a spot light at various angles was calculated. We regarded that ratio represented the moisture of tongue surface. To evaluate the performance of suggested method, we observed the correlation between conventional contact method and our method with 19 healthy subjects. Results: With comparison to conventional contact method (Schirmer test), the suggested method showed good correlation (R = 0.8602, R2 = 0.7399). Conclusion: This Method could be a convenient and robust method to evaluate tongue moisture.

New Current Measurement Device in Resistance Spot Welding by Using the Ring Deformation (링의 변형을 이용한 저항용접 전류측정장치의 개발)

  • Park, S.W.;Na, S.J.
    • Proceedings of the KWS Conference
    • /
    • 1990.11a
    • /
    • pp.82-86
    • /
    • 1990
  • A new method was investigated to measure the high current in resistance welding processes. A measuring unit was developed by using a strain gage attached on the outer surface of a steel ring. The steel ring was placed around a section of the secondary loop of the welding machine, and was deformed by electro-magnetic forces induced by the high welding current. The circumferential constituent of the ring deformation was then used to obtain a signal voltage proportional to the secondary welding current. The strain gage signal of ring deformation is enough to determine the welding current in resistance spot welding, especially when welded with direct current.

  • PDF