• Title/Summary/Keyword: Spot measurement

Search Result 234, Processing Time 0.022 seconds

Extended Target State Vector Estimation using AKF (적응형 칼만 필터를 이용한 확장 표적의 상태벡터 추정 기법)

  • Cho, Doo-Hyun;Choi, Han-Lim;Lee, Jin-Ik;Jeong, Ki-Hwan;Go, Il-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.6
    • /
    • pp.507-515
    • /
    • 2015
  • This paper proposes a filtering method for effective state vector estimation of highly maneuvering target. It is needed to hit the point called 'sweet spot' to increase the kill probability in missile interception. In paper, a filtering method estimates the length of a moving target tracked by a frequency modulated continuous wave (FMCW) radar. High resolution range profiles (HRRPs) is generated from the radar echo signal and then it's integrated into proposed filtering method. To simulate the radar measurement which is close to real, the study on the properties of scattering point of the missile-like target has been conducted with ISAR image for different angle. Also, it is hard to track the target efficiently with existing Kalman filters which has fixed measurement noise covariance matrix R. Therefore the proposed method continuously updates the covariance matrix R with sensor measurements and tracks the target. Numerical simulations on the proposed method shows reliable results under reasonable assumptions on the missile interception scenario.

Urinary Protein and Enzyme Excretion of Spot Urine in Children with Vesicoureteral Reflux (방광요관 역류증 환아의 단회뇨에서 요단백 및 효소 배설 측정)

  • Yoon, Jung-Rim;Koo, Ja-Wook
    • Childhood Kidney Diseases
    • /
    • v.13 no.1
    • /
    • pp.56-62
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the clinical usefulness of measurement of ${\beta}_2$ microglobulin (${\beta}_2$ MG), N-acetyl-$\beta$-D-glucosaminidase (NAG) of spot urine samples as indices of renal tubular damage and microalbumin of spot urine samples as a parameter of glomerular damage in children with vesicoureteral reflux (VUR) or renal defects. Methods : We studied 91 children with previous UTI. The children were classified as 62 children without VUR and renal defects (group I), 10 children with VUR, without renal defects (group II), and 19 children with VUR and renal defects (group III). Patients having VUR were separated according to the degree of VUR (mild VUR: VUR grade I-III, severe VUR: VUR grade IV-V). Urinary excretion of ${\beta}_$ microglobulin (${\beta}_2$ MG), microalbumin, N-acetyl-$\beta$-D-glucosaminidase (NAG), creatinine were measured in samples of morning urine specimens. Children with VUR or renal defects detected by voiding cystourethrography (VCUG) and DMSA renal scan were investigated. Results : Microalbumin/Cr ratio of spot urine was significantly increased in group III compared group I ($42.3{\pm}27.2\;mg/gCr$ vs $25.2{\pm}10.9\;mg/gCr$, P<0.05). NAG/Cr ratio of spot urine was significantly increased in group II compared group I ($3.70{\pm}23.4\;mg/gCr$ vs $18.7{\pm}12.7\;mg/gCr$, P<0.05). There was no statistically significant difference of ${\beta}_2$ MG/Cr ratio among three groups. Conclusion : Urinary microalbumin excretion of morning urine sample may be a simple and reliable clinical indicators for early identification of renal damage in children with VUR and renal defects. Urinary microalbumin excretion may be useful marker to predict the the severity of VUR.

Visualization and Image Processing for Measurement of Propagational Velocity of Shear Front (유동장의 이동속도측정을 위한 가시화 및 영상처리 방안)

  • Kim Jae-Won;Han Sang-Hoon;Ahn Eun-Young
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.10
    • /
    • pp.1322-1328
    • /
    • 2005
  • The circulation flows passing through the Ekman boundary layer on the rotating disk and transfer the angular momentum into the interior region of the container. Consequently, the circulation enhances the momentum transfer and the interior fluid is divided by a propagating shear front. This investigation focuses on computer vision and image processing technique for analysis of Non-Newtonian Fluids. To visualize marching velocity shear front for the transient flow, a particular shaped particles and light are used. To validate the proposed method, quantitative image are compared with the optical data acquired by a direct measurement of LDV (Laser Doppler Velocimetry).

  • PDF

A study on a fast measuring algorithm of wavefront for an adaptive optics system (적응광학시스템의 고속 파면측정 알고리즘에 대한 연구)

  • 박승규;백성훈;서영석;김철중;박준식;나성웅
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.251-257
    • /
    • 2002
  • The measuring resolution and speed for wavefronts are important to improve the performance of an adaptive optics system. In this paper, we propose a fast measuring algorithm with high resolution in the Shack-Hartmann wavefront sensor for an adaptive optics system. We designed ground isolated electrical devices whose differential data signals are used to control the deformable mirror and tip/tilt mirror for robust control. The conventional mass centroid algorithm in the Shack-Hartmann sensor to measure wavefront has been widely used and provided good measurement results. In this paper, the proposed fast measuring algorithm for measuring the wavefront combines the conventional mass centroid algorithm with a weighting factor. The weighting factor is a real value estimating the real center of mass in a wavefront spot image. This proposed wavefront measuring algorithm provided fast measurement results with high resolution from experimental tests.

A Study on the Measurement of Foreign Material in Dissimilar Metal Contact Using Pulse Laser and Confocal Fabry-Perot Interferometer (펄스 레이저와 CFPI를 이용한 이종금속 접촉부의 이물질 측정에 관한 연구)

  • Hong, Kyung-Min;Kang, Young-June;Park, Nak-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.160-164
    • /
    • 2013
  • A laser ultrasonic inspection system is a non-contact inspection device which generates and measures ultrasonics by using laser beam. A laser ultrasonic inspection system provides a high measurement resolution because the ultrasonic signal generated by a pulse laser beam has a wide-band spectrum and the ultrasonic signal is measured from a small focused spot of a measuring laser beam. In this study, galvanic corrosion phenomenon was measured by non-destructive and non-contact method using the laser. The case of mixed foreign material on the part of corrosion was assumed and laser ultrasonic experiment was conducted. Ultrasonic was generated by pulse laser from the back side of the specimen and ultrasonic signal was acquired from the same location of the front side using continuous wave laser and Confocal Fabry-Perot Interferometer(CFPI). The characteristic of the ultrasonic signal of exist foreign material part was analyzed and the location and size of foreign material was measured.

Growth of ZnTe Thin Films by Oxygen-plasma Assisted Pulsed Laser Deposition

  • Pak, Sang-Woo;Suh, Joo-Young;Lee, Dong-Uk;Kim, Eun-Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.185-185
    • /
    • 2011
  • ZnTe semiconductor is very attractive materials for optoelectronic devices in the visible green spectral region because of it has direct bandgap of 2.26 eV. The prototypes of ZnTe light emitting diodes (LEDs) have been reported [1], showing that their green emission peak closely matches the most sensitive region of the human eye. Another application to photovoltaics proved that ZnTe is useful for the production of high-efficiency multi-junction solar cells [2,3]. By using the pulse laser deposition system, ZnTe thin films were deposited on ZnO thin layer, which is grown on (0001) Al2O3substrates. To produce the plasma plume from an ablated ZnO and ZnTe target, a pulsed (10 Hz) YGA:Nd laser with energy density of 95 mJ/$cm^2$ and wavelength of 266 nm by a nonlinear fourth harmonic generator was used. The laser spot focused on the surface of the ZnO and ZnTe target by using an optical lens was approximately 1 mm2. The base pressure of the chamber was kept at a pressure around $10^{-6}$ Torr by using a turbo molecular pump. The oxygen gas flow was controlled around 3 sccm by using a mass flow controller system. During the ZnTe deposition, the substrate temperature was $400^{\circ}C$ and the ambient gas pressure was $10^{-2}$ Torr. The structural properties of the samples were analyzed by XRD measurement. The optical properties were investigated by using the photoluminescence spectra obtained with a 325 nm wavelength He-Cd laser. The film surface and carrier concentration were analyzed by an atomic force microscope and Hall measurement system.

  • PDF

Comparison of Selected Joint Angles at Golf Address Among Three Different Somatotypes (체형에 따른 골프 어드레스 동작의 주요 관절각도 비교)

  • Choi, Min-Chul;Lee, Chang-Jin;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.437-445
    • /
    • 2010
  • This study was aimed at comparing selected joint angles at the golf address stance by categorizing three different body types. 43 elite male golfers were selected and 9 of them turned out to be the ectoderm while 24 of them to be the mesoderm. The remaining 10 subjects were the endoderm. The measurement was carried out at the address stance with the number 7 iron and the driver. The result showed that the angle of trunk flexion did not different among body types. The trunk tilting angle became more inclined to the right side, which confirmed the guidelines from most of golf lesson books, for bigger people since they tended to put more weight on the right foot. The angle of both knees showed similar but the right knee was bent more than the left knee. The target direction and body alignment faced more to the left side than the target spot because of the influence of open stance and natural aiming position. It seems that pelvis and knees turned a little bit more to the right side than the target direction in order to maintain the parallel. Overall, significant differences among body types were found at the trunk tilting angle and pelvis-target alignment and golf address configuration can be differentiate by these factors.

Implementation of Ontology-based Service by Exploiting Massive Crime Investigation Records: Focusing on Intrusion Theft (대규모 범죄 수사기록을 활용한 온톨로지 기반 서비스 구현 - 침입 절도 범죄 분야를 중심으로 -)

  • Ko, Gun-Woo;Kim, Seon-Wu;Park, Sung-Jin;No, Yoon-Joo;Choi, Sung-Pil
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.53 no.1
    • /
    • pp.57-81
    • /
    • 2019
  • An ontology is a complex structure dictionary that defines the relationship between terms and terms related to specific knowledge in a particular field. There have been attempts to construct various ontologies in Korea and abroad, but there has not been a case in which a large scale crime investigation record is constructed as an ontology and a service is implemented through the ontology. Therefore, this paper describes the process of constructing an ontology based on information extracted from instrusion theft field of unstructured data, a crime investigation document, and implementing an ontology-based search service and a crime spot recommendation service. In order to understand the performance of the search service, we have tested Top-K accuracy measurement, which is one of the accuracy measurement methods for event search, and obtained a maximum accuracy of 93.52% for the experimental data set. In addition, we have obtained a suitable clue field combination for the entire experimental data set, and we can calibrate the field location information in the database with the performance of F1-measure 76.19% Respectively.

A Study on Design and Analysis for Magnetic Lenses of a Scanning Electron Microscope using Finite Element Method (유한요소법을 사용한 주사전자 현미경의 전자렌즈 설계 및 해석에 관한 연구)

  • Park, Keun;Jung, Hyun-Woo;Park, Man-Jin;Kim, Dong-Hwan;Jang, Dong-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.95-102
    • /
    • 2007
  • The scanning electron microscope (SEM) is one of the most popular instruments available for the measurement and analysis of the micro/nano structures. It is equipped with an electron optical system that consists of an electron beam source, magnetic lenses, apertures, deflection coils, and a detector. The magnetic lenses playa role in refracting electron beams to obtain a focused spot using the magnetic field driven by an electric current from a coil. A SEM column usually contains two condenser lenses and an objective lens. The condenser lenses generate a magnetic field that forces the electron beams to form crossovers at desired locations. The objective lens then focuses the electron beams on the specimen. The present work concerns finite element analysis for the electron magnetic lenses so as to analyze their magnetic characteristics. To improve the performance of the magnetic lenses, the effect of the excitation current and pole-piece design on the amount of resulting magnetic fields and their peak locations are analyzed through the finite element analysis.

A Study on the Sizes of Ready-made Clothes to Export to China - Suggestion of Chinese Correspondent Sizes Based on Korean Women's Clothes - (중국수출(中國輸出) 여성기성복(女性旣成服)의 치수(値數)에 관(關)한 연구(硏究) - 한국(韓國) 여성복(女性服)을 중심(中心)으로 한 중국(中國) 여성복(女性服)의 대응치수(對應値數) 제시(提示)-)

  • Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.8 no.4
    • /
    • pp.1-21
    • /
    • 2004
  • This research suggest the correspondent sizes of female ready-made clothes to export to China on the basis of those of Korean women's ready-made clothes. The following is the concrete coverage of this research: $\cdot$ Analyze the physical measurements and body types of the women in their 30s and 40s in the area of Ningbo, Jeolgang Province in China. $\cdot$ Compare the body measurements of Chinese and Korean women. $\cdot$ Hold compensation measurement by an basic torso pattern test to raise precision of the direct and indirect body measurements. $\cdot$ Establish the corresponding and representative sizes of women's ready-made clothes to go to China. $\cdot$ Make basic torso pattern and sample clothes reflecting representative sizes. $\cdot$ Hold adjustment and compensation through the wearing evaluation by Chinese consumers on the spot. $\cdot$ Finally suggest the correspondent sizes of women's ready-made clothes to export to China.