• Title/Summary/Keyword: Split ratio

Search Result 346, Processing Time 0.026 seconds

Effect of Nitrogen Split Application on Growth and Yield in Direct Seeding Rice on Flooded Paddy (담수직파재배시(湛水直播栽培時) 질소분시방법(窒素分施方法)에 따른 벼 생육(生育)과 수량성(收量性))

  • Yoo, Chul-Hyun;Shin, Bog-Woo;Lee, Sang-Bog;Rhee, Gyeong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.4
    • /
    • pp.312-318
    • /
    • 1995
  • To investigate the effect of N split application on the increasing ratio of yield and the yield of rice, urea and slow-releasing complex for sideband placement of fertilizer were applied in Jeonbuk series of Honam plain area. Increasing ratio of yield by N split application was higher in puddled drill seeding (PDS) than flooded direct seeding surface (FDSS) under split application of 40-0-30-30% and 70-0-0-30% at basal, 3 leaf, 5 leaf and panicle initiation stage, respectively. It was also higher in LCU application of 70 % of total urea amount than urea application but was not different between two methods of seeding in urea application. Nitrogen ratio transfered to rough grain of rice was higher in FDSS than PDS, errespective of methed of split application, except for the split application of 0, 40, 30 and 30% N fertilizer at basal, 3 leaf, 5 leaf and panicle initiation stage, respectively. Nitrogen amount outflowed by artificial drainage for paddy field drying in a day after application of fertilizer was 1,134g/10a in PDS. $NH_4-N$ incerased higher in PDS than FDSS under split application of urea, while was versa under LCU application.

  • PDF

Efficient determination of the size of experiments by using graphs in balanced design of experiments (균형된 실험계획법에서 그래프를 활용한 실험의 크기의 효율적인 결정)

  • Lim, Yong B.;Youn, Sora;Chung, Jong Hee
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.651-658
    • /
    • 2018
  • Purpose: The algorithm described in Lim(1998) is available to determine the sample size directly given specified significance level, power and signal-to-noise ratio. We research on the efficient determination of the sample size by visual methods. Methods: We propose three graphs for investigating the mutual relationship between the sample size r, power $1-{\beta}$ and the detectable signal-to-noise ratio ${\Delta}$. First graph shows the relationship between ${\Delta}$ and $1-{\beta}$ for the given r and it can be checked whether the power is sufficient enough. Second graph shows the relationship between r and ${\Delta}$ for the given power $1-{\beta}$. Third graph shows the relationship between r and $1-{\beta}$ for the given ${\Delta}$. It can be checked that which effects are sensitive to the efficient sample size by investigating those graphs. Results: In factorial design, randomized block design and the split plot design how to determine the sample size directly given specified significance level, power and signal-to-noise ratio is programmed by using R. A experiment to study the split plot design in Hicks(1982) is used as an example. We compare the sample sizes calculated by randomized block design with those by split plot design. By using graphs, we can check the possibility of reducing the sample size efficiently. Conclusion: The proposed visual methods can help an engineer to make a proper plan to reduce the sample size.

Analysis of ELF Magnetic Field Reduction Factor of Electric Power Transmission Line (송전 선로 극저주파 자기장 저감지수(FRF) 특성 해석)

  • Myung, Sung-Ho;Cho, Yeon-Gyu;Lee, Dong-Il;Lim, Yun-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1132-1142
    • /
    • 2006
  • This paper examined electric power transmission line models of reducing ELF(Extremely Low Frequency) magnetic field and analyzed the effects about models. In this research, FRF(Field Reduction Factor) of various models reducing magnetic field were analyzed compared to the horizontal 154 kV transmission line. As a result, the reduction ratio of magnetic field was almost proportioned to the compaction of phase-to-phase distance, and in case of diamond model and transposed model, magnetic field was able to be reduced nearly 50 %. It was analyzed that the magnetic field reduction ratio of triangle model was about 33 % and the magnetic field reduction ratio of split model was able to be reduced to 50 %. Especially, the magnetic field reduction ratio of multi split model could be reduced to 80 %.

Flame Structure and NOx Emission Characteristics in Laminar Partially Premixed $CH_4$/Air Flames;Effect of Premixing Degree (메탄/공기 층류 부분 예혼합화염의 화염구조와 NOx 배출특성;예혼합 인자의 영향)

  • Oh, Jeong-Seog;Jeong, Yong-Ki;Jeon, Chung-Hwan;Chang, Young-June
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.75-81
    • /
    • 2003
  • In this paper, the study of effects of flow variables on flame structure and NOx emission concentration was performed in co-axial laminar partially premixed methane/air flames. the objectives are to reveal its effect as parameters were varied and to understand the correlation between flame structure and NOx emission characteristics in the reaction zone. equivalence ratio(${\Phi}$), fuel split degree(${\sigma}$), and mixing distance(x/D) were defined as a premixing degree and varied within $1.36{\sim}3.17$(equivalence ratio), $50{\sim}100$(fuel split degree), and $5{\sim}20$(mixing distance). the image of $OH{\ast}$ and $CH{\ast}$, and NOx concentration were obtained with an ICCD camera and a NOx analyzer. additionally the maximum intensity location of $OH{\ast}$ chemiluminescence and $CH{\ast}$ chemiluminescence were measured to compare each flame structures. In conclusion flame structure and NOx emission characteristics were changed from diffused to premixed flame when mixing degree was on the increase. the main effect on flame structure and NOx production was at first equivalence ratio(${\Phi}$), and next fuel split degree(${\sigma}$), and finally mixing distance(x/D).

  • PDF

Performance control analysis of concrete-filled steel tube sepa-rated spherical joint wind power tower

  • Yang Wen;Guangmao Xu;Xiazhi Wu;Zhaojian Li
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.137-149
    • /
    • 2023
  • In this study, to explore the working performance of the CFST split spherical node wind power tower, two groups of CFST split spherical joint plane towers with different web wall thicknesses and a set of space systems were analyzed. The tower was subjected to a low-cycle repeated load test, and the hysteresis and skeleton curves were analyzed. ABAQUS finite element simulation was used for verification and comparison, and on this basis parameter expansion analysis was carried out. The results show that the failure mode of the wind power tower was divided into weld tear damage between belly bar, high strength bolt thread damage and belly rod flexion damage. In addition, increasing the wall thickness of the web member could render the hysteresis curve fuller. Finally, the bearing capacity of the separated spherical node wind power tower was high, but its plastic deformation ability was poor. The ultimate bearing capacity and ductility coefficient of the simulated specimens are positively correlated with web diameter ratio and web column stiffness ratio. When the diameter ratio of the web member was greater than 0.13, or the stiffness ratio γ of the web member to the column was greater than 0.022, the increase of the ultimate bearing capacity and ductility coefficient decreased significantly. In order to maximize the overall mechanical performance of the tower and improve its economy, it was suggested that the diameter ratio of the ventral rod be 0.11-0.13, while the stiffness ratio γ should be 0.02-0.022.

Analysis of Structural Characteristics of Power-Split Type Planetary Gear Train (동력 분배형 유성기어열의 구조 특성 분석)

  • Lee, Ki-Hun;Lee, Geun-Ho;Bae, In-Ho;Lee, Joung-Sang;Chong, Tae-Hyong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.311-314
    • /
    • 2008
  • The volume and size of the wind turbine gearbox has been increased with increasing transmitted power. The optimal sizing of gearbox is important due to limited space on the nacelle. The power-split type planetary gear train has been regarded as a better solution than conventional type from the point of view of the volume and weight. The purpose of this paper is to optimize the volume and weight of the gearbox by the analysis of structural characteristics and evaluation of strength of the power-split type planetary gear train.

  • PDF

Flame Structure and NOx Emission Characteristics in Laminar Partially Premixed CH4/Air Flames: Effects of Fuel Split Percentage and Mixing Distance (메탄/공기 층류 부분예혼합화염의 화염구조와 NOx 배출특성 : 연료분배율과 혼합거리의 영향)

  • Jeong, Yong-Ki;Lee, Jong-Ho;Lee, Suk-Young;Jeon, Chung-Hwan;Chan, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.7
    • /
    • pp.818-825
    • /
    • 2004
  • In this paper, the study of effects of flow parameters on flame structure and NOx emission concentration was performed in co-axial. laminar partially premixed methane/air flames. Such (low parameters as equivalence ratio(${\Phi}$), fuel split percentage($\sigma$), and mixing distance(x/D$\_$i/) were defined as a premixing degree and varied within ${\Phi}$=1.36∼9.52, $\sigma$=50∼100, and x/D$\_$i/=5∼20. The image of OH$\^$*/ and NOx concentration were obtained with an ICCD camera and a NOx analyzer. The flame structure observations show a categorization of partially premixed flames into three distinct flame regimes corresponding to ${\Phi}$<1.7(premixed flame structure), 1.7<${\Phi}$<3.3(hybrid structure), and ${\Phi}$>3.3(diffusion flame structure existing a luminous sooting region) at $\sigma$=75%, and x/D$\_$i/=10. As o decreases from 100% to 50%, and x/D$\_$i/ decreases, nonpremixed flame structure appear at low equivalence ratio relatively. In addition, the measured emissions for NOx rise steeply from ${\Phi}$=1.7, to ${\Phi}$=3.3, then constants ${\Phi}$>4.76. NOx emissions decrease with increase the level of premixing level. In conclusion, the main effect on flame structure and NOx production was at first equivalence ratio(${\Phi}$), and next fuel split percentage($\sigma$), and finally mixing distance(x/D$\_$i/).

A Study on Setting Darts and Split Lines of Upper Bodice Pattern on 3D Parametric Model dressed with Tight-fit Garment (밀착의형 3차원 파라메트릭 모델을 활용한 상반신 원형의 다트 및 절개분리선 설정에 관한 연구)

  • Park, Soon-Jee;Kim, Hye-Jin
    • Fashion & Textile Research Journal
    • /
    • v.12 no.4
    • /
    • pp.467-476
    • /
    • 2010
  • The purpose of this study was to develop a plausible methodology based on experimental data how to set up darts and split lines on 3D parametric body dressed with tight-fit garment. The results were as following: Through the process of making convex hull, the concave parts were straightened to make a convex hull, especially in the center part of bust, under breast part and scapular part. To figure out the optimum positions of darts and split lines, the inflection points of curve ratio were searched along the horizontal polylines of waist and bust. This procedures produced reliable results with low deviation. Using Rapidform, CATIA and Unigraphics, six patches of bodice patterns were drawn and aligned. Paired t-test results showed the outline and area between 3D surface and 2D were not significantly different, meaning this method could be adaptable when flattening 3D surfaces. The amount of waist dart measured on the pattern showed that the highest portion was allocated on 2nd dart(back), followed by 1st dart(back), 1st dart(front), 2nd dart(front)/side dart, and center back dart. A series of findings suggested that curve ration inflection point could be used as a guide to set up darts and split line on 3D parametric model with low deviation.

Development of CVTs Composed of a 2K-H I Type Differential Gear Unit and a V-belt Drive (2K-H형 I 형식 차동기어장치와 V-belt 전동장치를 결합한 무단변속기의 개발)

  • Kim, Yeon-Su;Choi, Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1060-1068
    • /
    • 2002
  • Compound continuously variable transmission(CVT) mechanisms are proposed, which can offer a backward mode, a geared neutral, an underdrive mode and an overdrive mode. They are composed of a 2K-H I type differential gear unit, a V-belt type continuously variable unit(CVU), a few friction clutches and gears, and not required of a starting device as a torque converter. Compound CVT mechanisms developed here present two distinct operating modes which are a power circulation mode and a power split mode. The transition of two modes takes place at the particular CVU speed ratio. For these CVT mechanisms, performance analysis related to speed ratio, power ratio and efficiency are executed and proven by experimental studies.

A Study on the Performance of Continuously Variable Transmission composed of V-belt Drive and 2K-H type Differential Gear Unit (2K-H형 차동기어장치와 V-belt를 결합한 무단변속기의 성능에 관한 연구)

  • 박재민;김연수;최상훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.739-742
    • /
    • 1997
  • Continuously variable transmission(CVT) mechanisms are proposed, which can offer a backward mode, a geared neutral, an underdrive mode and an overdriver mode. They are not required of a starting device as a torque converter. CVT mechanisms developed here present two distinct operating modes which are a power circulation mode and a power split mode. The transition of two modes takes place at the particular CVU speed ratio. For these CVT mechanisms, performance analysis related to speed ratio, power ratio and theoretical efficiency are executed.

  • PDF