• Title/Summary/Keyword: Split Factor

Search Result 196, Processing Time 0.028 seconds

Preliminary Study for the Development of Optimum Fuel Contact Conductance Model (최적 핵연료 접촉 열전도도 모델 개발을 위한 예비 연구)

  • Yang, Yong-Sik;Shin, Chang-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2488-2493
    • /
    • 2007
  • A gap conductance is very important factor which can affect nuclear fuel temperature. Especially, in case of an annular fuel, a gap conductance effect can lead an unexpected heat split phenomena which is caused by a large difference of an inner and outer gap conductance. The gap conductance mechanism is very complicated behavior due to the its strong dependency on microscopic factors such as a contact surface roughness, local contact pressure and local temperature. In this paper, for the decision of test temperature and pressure range, a procedure and calculation results of in-reactor fuel temperature and pressure analysis are summarized which can be applied to test equipment design and determination of test matrix. Based upon analysis results, it is concluded that the minimum and maximum test temperature are $300^{\circ}C$ and $530^{\circ}C$ respectively, and the maximum pellet/cladding interfacial contact pressure should be observed up to 45MPa.

  • PDF

Experimental study of combustion stability assesment of injector (액체로켓엔진 안정성 예측을 위한 시험적 기법 연구)

  • Lee, Kwang-Jin;Seo, Seong-Hyeon;Moon, Il-Yoon;Han, Yeoung-Min;Seol, Woo-Seok;Lee, Soo-Yong
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.145-152
    • /
    • 2003
  • The objective of the present study is to develop methodology for the assesment of combustion stability of liquid rocket injectors. To simulate actual combustion occurring inside of a thrust chamber, a full-scale injector has been employed in the study, which burns gaseous oxygen and mixture of methane and propane. The main idea of the experiment is that the mixing mechanism is considered as a dominant factor significantly affecting combustion instability in a full-scale thrust chamber. Single & multi split triplet injectors have been used with an open-end cylindrical combustion chamber. The characteristics revealed by excited dynamic pressures in gaseous combustion show degrees of relative acoustic damping depending on operating conditions. Upon test results, the direct comparison between various types of injectors can be realized for the selection of the best design among prospective injectors.

  • PDF

Analysis of Fiber Nonlinearities by Perturbation Method

  • Lee Jong-Hyung;Han Dae-Hyun;Choi Byeong-Yoon
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.6-12
    • /
    • 2005
  • The perturbation approach is applied to solve the nonlinear Schrodinger equation, and its valid range has been determined by comparing with the results of the split-step Fourier method over a wide range of parameter values. With γ= 2㎞/sup -1/mW/sup -1/, the critical distance for the first order perturbation approach is estimated to be(equation omitted). The critical distance, Z/sub c/, is defined as the distance at which the normalized square deviation compared to the split-step Fourier method reaches 10/sup -3/. Including the second order perturbation will increase Z/sub c/ more than a factor of two, but the increased computation load makes the perturbation approach less attractive. In addition, it is shown mathematically that the perturbation approach is equivalent to the Volterra series approach, which can be used to design a nonlinear equalizer (or compensator). Finally, the perturbation approach is applied to obtain the sinusoidal response of the fiber, and its range of validity has been studied.

Biological Treatment of Livestock Wastewater using Aerobic Granular Sludge (호기성 그래뉼 슬러지를 이용한 축산폐수의 생물학적 처리에 관한 연구)

  • Hyun-Gu Kim;Dae-Hee Ahn
    • Journal of Environmental Science International
    • /
    • v.32 no.7
    • /
    • pp.483-492
    • /
    • 2023
  • In this study, the treatment of livestock wastewater using an aerobic granular sludge based sequencing batch reactor was investigated. The reactor operation was carried out by general injection and split injection methods. The average removal efficiency of organic matter after the adaptation period was 71.5 and 87.4%, respectively. Some untreated organic matter was attributed to recalcitrant organic matter. The average removal efficiency of total nitrogen was 65.6 and 88.4%, respectively. These results indicate that the denitrification reaction by split injection was carried out smoothly. As for the solids, the ratio of aerobic granular sludge/mixed liquor suspended solid can be determined as the main factor of the process operation, and the ratio increased gradually and finally reached 86.0%. Correspondingly, the sludge volume index (SVI) was also improved, reaching 54 mL/g at the end of operation, and it is believed that the application of a short settling time contributed to the improvement of settleability.

Changes of the Airway Space and the Position of Hyoid Bone after Mandibular Set Back Surgery Using Bilateral Sagittal Split Ramus Osteotomy Technique

  • Choi, Sung-Keun;Yoon, Ji-Eun;Cho, Jung-Won;Kim, Jin-Woo;Kim, Sun-Jong;Kim, Myung-Rae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.5
    • /
    • pp.185-191
    • /
    • 2014
  • Purpose: Although there have been several studies of reduced airway space after mandibular setback surgery using the sagittal split ramus osteotomy technique, research on the risk factors for changes of the airway space is lacking. Therefore, this study was performed to examine airway changes and the position of the hyoid bone after orthognathic surgery, and to assess possible risk factors. Methods: In this retrospective study, 50 patients who underwent posterior displacement of the mandible by the bilateral sagittal split ramus osteotomy technique were included. Changes of the position of the hyoid bone and the airway space were analyzed over various follow-up periods, using cephalometric radiography taken preoperatively, immediately after surgery, eight weeks after surgery, six months after surgery, and one year after surgery. To identify risk factors, multiple regression analysis of age, gender, body mass index (BMI), posterior mandibular movement, and the presence of genioplasty was performed. Results: Inferor and posterior movement of the hyoid bone was observed postoperatively, but subsequent observations showed regression towards the anterosuperior aspect. The airway space also significantly decreased after surgery (P<0.05), and increased slightly up until six months after surgery. The airway space significantly decreased (${\beta}=0.47$, P<0.01) as the amount of mandibular setback increased. However, age, sex, BMI, and presence of genioplasty were not associated with airway reduction. Conclusion: The amount of mandibular set back was significantly associated with postoperative reduction of airway space. It is necessary to establish a treatment plan considering this factor.

Design, fabrication and performance characteristics of a 50kHz tonpilz type transducer with a half-wavelength diameter (반파장 직경을 갖는 50kHz tonpilz형 음향 변환기의 설계, 제작 및 성능특성)

  • Lee, Dae-Jae;Lee, Won-Sub
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.2
    • /
    • pp.173-183
    • /
    • 2010
  • In a split beam echo sounder, the transducer design needs to have minimal side lobes because the angular position and level of the side lobes establishes the usable signal level and phase angle limits for determining target strength. In order to suppress effectively the generation of unwanted side lobes in the directivity pattern of split beam transducer, the spacing and size of the transducer elements need to be controlled less than half of a wavelength. With this purpose, a 50 kHz tonpilz type transducer with a half-wavelength diameter in relation to the development of a split beam transducer was designed using the equivalent circuit model, and the underwater performance characteristics were measured and analyzed. From the in-air and in-water impedance responses, the measured value of the electro-acoustic conversion efficiency for the designed transducer was 51.6%. A maximum transmitting voltage response (TVR) value of 172.25dB re $1{\mu}Pa/V$ at 1m was achieved at 52.92kHz with a specially designed matching network and the quality factor was 10.3 with the transmitting bandwidth of 5.14kHz. A maximum receiving sensitivity (SRT) of -183.57dB re $1V/{\mu}Pa$ was measured at 51.45kHz and the receiving bandwidth at -3dB was 1.71kHz. These results suggest that the designed tonpilz type transducer can be effectively used in the development of a split beam transducer for a 50kHz fish sizing echo sounder.

AN EXPERIMENTAL STUDY OF PLATELET-DERIVED GROWTH FACTOR ABOUT BONE FORMATION IN DENTAL IMPLANT (혈소판 유래 성장인자가 임플란트 주위 골형성에 미치는 효과에 대한 실험적 연구)

  • Ryu, Jae-Jun;Kwon, Jong-Jin;Kim, Han-Kyum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.816-831
    • /
    • 1998
  • Bony fixation of implants during the early phase of healing is important in order to get secondary stability of the implant assuring the success of the treatment. Because the successful placement of the implant is limited by the quality and quantity of bone, other agents which stimulate bone formation in the peri-implant spaces has been illustrated. Platelet-derived growth factor (PDGF) has been shown to regulate DNA and protein synthesis in bone cells in vitro and to interact synergistically to enhance soft tissue wound healing in vivo. The purpose of this study was to evaluate bone promotion around implants which were augmented with sagittal split osteotomy or autogenous veneer bone graft using the platelet derived growth factor(PDGF). After placement of newly designed twenty four screw-type implants, which were 12mm in length and 4mm in diameter in 6 dogs. $4{\mu}g$ of PDGF B/B was applied with surgicel carriers. The dogs were sacrificed at 3 days, 1, 2, 3, 6, and 12 weeks after implantation. Specimens were examined clinically, radiographically, histologically, and histomorphometrically. The results were as follows: 1. Clinically and radiologically, there was no significant difference in bone formation and healing pattern between experimental and control group. 2. In autogenous veneer bone graft group, bone formation was observed at 1st week in the experimental groups but 2nd week in the control groups. At 3rd week, the expeimental groups showed more bone formation comparing to the control groups. 3. In sagittal split osteotomy group, bone formation was observed at 1st week in both groups. But the experimental groups showed more bone formation comparing to the control groups after 2nd week. 4. The bone growth rate of experimental group was more rapid than that of control group. These results indicated that PDGF did not affect the initiation of new bone formation, but it accelerated the bone formation at the early period.

  • PDF

Development of a Measurement Instrument for Parenting Behavior of Primary Caregivers in Early Childhood (유아기 주 양육자의 양육행위 측정도구 개발)

  • Park, Sun-Jung;Kang, Kyung-Ah
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.5
    • /
    • pp.650-660
    • /
    • 2015
  • Purpose: The purpose of this study was to develop an instrument to measure the parenting behavior of primary caregivers of children in early childhood. Methods: An instrument was developed according to Devellis's instrument development process. The participants in this study who completed the main survey were 370 mothers and grandmothers. The survey was conducted from June 1 to July 30, 2014, and collected data were analyzed using item analysis, half-split reliability and Cronbach's ${\alpha}$ coefficient, exploratory and confirmatory factor analysis, convergent validity. Results: The factor structure of the instrument showed the cumulative variance as 55.7% in the factor analysis. As a result of a confirmatory factor analysis, a four-factor structure was found to be appropriate, and the construct validity and convergent validity of the instrument were thereby confirmed. The finalized parenting behavior instrument consisted of 26 items and four independent factors: affectionate, laissez-faire, educational and impulsive. A five-point Likert scale was employed, and a higher score in a particular factor showed that most of the behaviors belonged to the factor. Conclusion: The instrument developed in this study was found to be reliable and valid, and can be used to develop parent-child relationship building.

Experimental Study on Pressure Loss of Flow Parallel to Rod Bundle with Spacer Grid (지지격자가 있는 봉다발과 축방향으로 평행한 유동의 압력손실에 관한 실험적 연구)

  • Lee, Chi-Young;Shin, Chang-Hwan;Park, Ju-Yong;In, Wang-Kee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.689-695
    • /
    • 2012
  • The friction factor in a rod bundle and the loss coefficient at a spacer grid were examined. As a test section, 25 smooth rods, 9.5 mm in diameter and 2000 mm in length, were prepared and installed in a $5{\times}5$ square array in a square channel. In this case, the P/D (Pitch-to-Diameter ratio) was 1.35. In this work, plain (i.e., no mixing vanes), split-vane, and hybrid-vane spacer grids were tested. In a bare rod bundle (i.e., no spacer grid), the measured friction factors were in good agreement with the previous correlations. Among the spacer grids tested, the hybrid-vane spacer grid presented the largest friction factor in the rod bundle and loss coefficient. This may be because of the flow pattern change induced by large relative plugging of the flow cross section and mixing vane geometry. At Re=$5{\times}10^5$, the predicted loss coefficients of plain, splitvane, and hybrid-vane spacer grids were approximately 0.79, 0.80, and 0.88, respectively.

Factor XI deficiency and orthognathic surgery: a case report on anesthesia management

  • Lee, Soo Eon;Choi, Yoon Ji;Chi, Seong-In;Kim, Hyun-Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.1
    • /
    • pp.25-29
    • /
    • 2015
  • Factor XI deficiency (Hemophilia C) is a very rare autosomal recessive bleeding disorder. Patients with factor XI deficiency do not typically show any spontaneous bleeding or specific symptoms. Sometimes those who have this disorder are identified during special situations such as trauma or surgery. Orthognathic surgery is particularly associated with a high bleeding risk. Therefore, great care must be taken when treating patients with bleeding disorders such as factor XI deficiency. There are a few reports that address the management of patients with bleeding disorders during orthognathic surgery. The current report describes a patient with factor XI deficiency who underwent Le Fort I osteotomy together with bilateral sagittal split osteotomy. The patient's condition was assessed using both rotation thromboelastometry ($ROTEM^{TM}$) and noninvasive measurements of total hemoglobin (SpHb) using Masimo Radical 7 (Masimo Co. CA, USA).