• 제목/요약/키워드: Split Beam

검색결과 148건 처리시간 0.028초

The influence of cuttlebone on the target strength of live golden cuttlefish (Sepia esculenta) at 70 and 120 kHz

  • Lee, Daejae
    • Fisheries and Aquatic Sciences
    • /
    • 제19권2호
    • /
    • pp.8.1-8.11
    • /
    • 2016
  • To quantitatively estimate the influence of cuttlebone on the target strength (TS) of golden cuttlefish, the cuttlebone was carefully extracted from 19 live cuttlefish caught using traps in the inshore waters around Geojedo, Korea, in early May 2010 and the TS was measured using split-beam echosounders (Simrad ES60 and EY500). The TS-length relationships for the cuttlefish (before the extraction of cuttlebone, Fish Aquat Sci. 17:361-7, 2014) and the corresponding cuttlebone were compared. The cuttlebone length ($L_b$) ranged from 151 to 195 mm (mean $L_b$ = 168.3 mm) and the mass ($W_b$) ranged from 29.3 to 53.2 g (mean $W_b$ = 38.8 g). The mean TS values at 70 and 120 kHz were -33.60 dB (std = 1.12 dB) and -32.24 dB (std = 1.87 dB), respectively. The mean TS values of cuttlebone were 0.19 dB and 0.04 dB lower than those of cuttlefish at 70 and 120 kHz, respectively. For 70 and 120 kHz combined, the mean TS value of cuttlebone was -32.87 dB, 0.11 dB lower than that of cuttlefish (-32.76 dB). On the other hand, the mean TS value of cuttlebone predicted by the regression ($TS_b$ = 24.86 $log_{10}$ $L_b$ - 4.86 $log_{10}$ ${\lambda}$ - 22.58, $r^2$ = 0.85, N = 38, P < 0.01) was -33.10 dB, 0.04 dB lower than that of cuttlefish predicted by the regression ($TS_c$ = 24.62 $log_{10}$ $L_c$ - 4.62 $log_{10}$ ${\lambda}$ - 22.64, $r^2$ = 0.85, N = 38, P < 0.01). That is, the contribution of cuttlebone to the cuttlefish TS determined by the measured results was slightly greater than that by the predicted results. These results suggest that cuttlebone is responsible for the TS of cuttlefish, and the contribution is estimated to be at least 99 % of the total echo strength.

Surgical approach and orthodontic treatment of mandibular condylar osteochondroma

  • Yang, So Jin;Chung, Nam Hyung;Kim, Jong Ghee;Jeon, Young-Mi
    • 대한치과교정학회지
    • /
    • 제50권3호
    • /
    • pp.206-215
    • /
    • 2020
  • Osteochondroma is a common benign tumor of bones, but it is rare in the mandibular condyle. With its outgrowth it manifests clinically as deviation of the mandible limitation of mouth opening, and facial asymmetry. After the tumor is diagnosed on the basis of clinical symptoms and radiographic examination including cone-beam computed tomography (CBCT) analysis, an appropriate surgery and treatment plan should be formulated. Herein, we present the case of a 44-year-old female patient who visited our dental hospital because her chin point had been deviating to the left side slowly but progressively over the last 3 years and she had difficulty masticating. Based on CBCT, she was diagnosed with skeletal Class III malocclusion accompanied by osteochondroma of the right mandibular condyle. Maxillary occlusal cant with the right side down was observed, but it was confirmed to be an extrusion of the molars associated with dental compensation. Therefore, after intrusion of the right molars with the use of temporary anchorage devices, sagittal split ramus osteotomy was used to remove the tumor and perform orthognathic surgery simultaneously. During 6 months after the surgery, continuous bone resorption and remodeling were observed in the condyle of the affected side, which led to a change in occlusion. During the postoperative orthodontic treatment, intrusive force and buccal torque were applied to the molars on the affected side, and a proper buccal overjet was created. After 18 months, CBCT revealed that the rate of bone absorption was continuously reduced, bone corticalization appeared, and good occlusion and a satisfying facial profile were achieved.

살오징어 (Todarodes pacifica)의 음향 반사강도 측정 (Acoustic Target Strength of Live Japanese Common Squid(Todarodes pacifica) for Applying Biomass Estimation)

  • 강돈혁;황두진;;;이경훈
    • 한국수산과학회지
    • /
    • 제37권4호
    • /
    • pp.345-353
    • /
    • 2004
  • Target strength (TS) of Japanese common squids (Todarodes pacificus) were measured using 38 and 120 kHz split beam scientific echosounders under the live condition. For the TS measurement of an individual, a total of 3 squids (mantle length (ML): 22.8, 25, and 27 cm) were used using small fishhook method, whereas for measurement of swimming angle, a total of 8 squids (ML: 21-27 cm) were used under live condition, confined with net cage with 2 m diameter At the same time, two underwater video cameras enabled continuous monitoring of squid behavior. Considering normal behavior, the mean TS at 38 and 120 kHz varied from -48.6 to -45.9 dB, and from -46.5 to -44.6 dB, respectively In both frequencies, mean TS at 120 kHz is relatively higher than that of 38 kHz, approximately 1.3-2.5 dB. From free living condition, the mean swimming angle of the squlds was $-24^{\circ}$. The results of the measurement will be provided basic information for conducting acoustic surveys of the squid.

Polarization Phase-shifting Technique for the Determination of a Transparent Thin Film's Thickness Using a Modified Sagnac Interferometer

  • Kaewon, Rapeepan;Pawong, Chutchai;Chitaree, Ratchapak;Bhatranand, Apichai
    • Current Optics and Photonics
    • /
    • 제2권5호
    • /
    • pp.474-481
    • /
    • 2018
  • We propose a polarization phase-shifting technique to investigate the thickness of $Ta_2O_5$ thin films deposited on BK7 substrates, using a modified Sagnac interferometer. Incident light is split by a polarizing beam splitter into two orthogonal linearly polarized beams traveling in opposite directions, and a quarter-wave plate is inserted into the common path to create an unbalanced phase condition. The linearly polarized light beams are transformed into two circularly polarized beams by transmission through a quarter-wave plate placed at the output of the interferometer. The proposed setup, therefore, yields rotating polarized light that can be used to extract a relative phase via the self-reference system. A thin-film sample inserted into the cyclic path modifies the output signal, in terms of the phase retardation. This technique utilizes three phase-shifted intensities to evaluate the phase retardation via simple signal processing, without manual adjustment of the output polarizer, which subsequently allows the thin film's thickness to be determined. Experimental results show that the thicknesses obtained from the proposed setup are in good agreement with those acquired by a field-emission scanning electron microscope and a spectroscopic ellipsometer. Thus, the proposed interferometric arrangement can be utilized reliably for non-contact thickness measurements of transparent thin films and characterization of optical devices.

Collapse Initiation and Mechanisms for a Generic Multi-storey Steel Frame Subjected to Uniform and Travelling Fires

  • Rackauskaite, Egle;Kotsovinos, Panagiotis;Lange, David;Rein, Guillermo
    • 국제초고층학회논문집
    • /
    • 제10권4호
    • /
    • pp.265-283
    • /
    • 2021
  • To ensure that fire induced collapse of a building is prevented it is important to understand the sequence of events that can lead to this event. In this paper, the initiation of collapse mechanisms of generic a multi-storey steel frame subjected to vertical and horizontal travelling fires are analysed computationally by tracking the formation of plastic hinges in the frame and generation of fire induced loads. Both uniform and travelling fires are considered. In total 58 different cases are analysed using finite element software LS-DYNA. For the frame examined with a simple and generic structural arrangement and higher applied fire protection to the columns, the results indicate that collapse mechanisms for singe floor and multiple floor fires can be each split into two main groups. For single floor fires (taking place in the upper floors of the frame (Group S1)), collapse is initiated by the pull-in of external columns when heated beams in end bays go into catenary action. For single floor fires occurring on the lower floors(Group S2), failure is initiated (i.e. ultimate strain of the material is exceeded) after the local beam collapse. Failure in both groups for single floor fires is governed by the generation of high loads due to restrained thermal expansion and the loss of material strength. For multiple floor fires with a low number of fire floors (1 to 3) - Group M1, failure is dominated by the loss of material strength and collapse is mainly initiated by the pull-in of external columns. For the cases with a larger number of fire floors (5 to 10) - Group M2, failure is dominated by thermal expansion and collapse is mainly initiated by swaying of the frame to the side of fire origin. The results show that for the investigated frame initiation of collapse mechanisms are affected by the fire type, the number of fire floors, and the location of the fire floor. The findings of this study could be of use to designers of buildings when developing fire protection strategies for steel framed buildings where the potential for a multifloor fire exists.

다중주파수를 이용한 살오징어(Todarodes pacificus)의 분포밀도 추정 (Density Estimation of Japanese Common Squid Todarodes pacificus Using Multi-frequency)

  • 신형호;정종일;이형빈;오우석;박근창;이경훈
    • 한국수산과학회지
    • /
    • 제54권6호
    • /
    • pp.1023-1029
    • /
    • 2021
  • The Japanese common squid Todarodes pacificus is one of the fish species within the total allowable catch (TAC) system which requires further investigation. In this study, the acoustic survey method was used to analyze the distribution of the Japanese common squid Todarodes pacificus across all the seas of South Korea. The sea area within Korea was investigated using the research vessels 20, 21, and 22 of the National Institute of Fisheries Science. The acoustic surveys were carried out from July to September 2019 and February to May 2020. The acoustic systems used in the survey had frequencies of 38 kHz and 120 kHz (EK60, EK80, Simrad, Norway) of the split-beam scientific echosounder. The results showed that, in spring, 277 m2/nmi2 was the highest in the east sea area, and the same in the summer season 880 m2/nmi2 was the highest in the east sea area. In autumn, the highest nautical area scattering coefficient (NASC) value was observed in the coastal portion of the south sea, and in winter, the NASC values were generally low in all the sea area.

A novel analytical evaluation of the laboratory-measured mechanical properties of lightweight concrete

  • S. Sivakumar;R. Prakash;S. Srividhya;A.S. Vijay Vikram
    • Structural Engineering and Mechanics
    • /
    • 제87권3호
    • /
    • pp.221-229
    • /
    • 2023
  • Urbanization and industrialization have significantly increased the amount of solid waste produced in recent decades, posing considerable disposal problems and environmental burdens. The practice of waste utilization in concrete has gained popularity among construction practitioners and researchers for the efficient use of resources and the transition to the circular economy in construction. This study employed Lytag aggregate, an environmentally friendly pulverized fuel ash-based lightweight aggregate, as a substitute for natural coarse aggregate. At the same time, fly ash, an industrial by-product, was used as a partial substitute for cement. Concrete mix M20 was experimented with using fly ash and Lytag lightweight aggregate. The percentages of fly ash that make up the replacements were 5%, 10%, 15%, 20%, and 25%. The Compressive Strength (CS), Split Tensile Strength (STS), and deflection were discovered at these percentages after 56 days of testing. The concrete cube, cylinder, and beam specimens were examined in the explorations, as mentioned earlier. The results indicate that a 10% substitution of cement with fly ash and a replacement of coarse aggregate with Lytag lightweight aggregate produced concrete that performed well in terms of mechanical properties and deflection. The cementitious composites have varying characteristics as the environment changes. Therefore, understanding their mechanical properties are crucial for safety reasons. CS, STS, and deflection are the essential property of concrete. Machine learning (ML) approaches have been necessary to predict the CS of concrete. The Artificial Fish Swarm Optimization (AFSO), Particle Swarm Optimization (PSO), and Harmony Search (HS) algorithms were investigated for the prediction of outcomes. This work deftly explains the tremendous AFSO technique, which achieves the precise ideal values of the weights in the model to crown the mathematical modeling technique. This has been proved by the minimum, maximum, and sample median, and the first and third quartiles were used as the basis for a boxplot through the standardized method of showing the dataset. It graphically displays the quantitative value distribution of a field. The correlation matrix and confidence interval were represented graphically using the corrupt method.

Impact of openings on the structural performance of ferrocement I-Beams under flexural loads

  • Yousry B.I. Shaheen;Ghada M. Hekal;Ayman M. Elshaboury;Ashraf M. Mahmoud
    • Structural Engineering and Mechanics
    • /
    • 제90권4호
    • /
    • pp.371-390
    • /
    • 2024
  • Investigating the impact of openings on the structural behavior of ferrocement I-beams with two distinct types of reinforcing metallic and non-metallic meshes is the primary goal of the current study. Up until failure, eight 250x200x2200 mm reinforced concrete I-beams were tested under flexural loadings. Depending on the kind of meshes used for reinforcement, the beams are split into two series. A control I-beam with no openings and three beams with one, two, and three openings, respectively, are found in each series. The two series are reinforced with three layers of welded steel meshes and two layers of tensar meshes, respectively, in order to maintain a constant reinforcement ratio. Structural parameters of investigated beams, including first crack, ultimate load, deflection, ductility index, energy absorption, strain characteristics, crack pattern, and failure mode were reported. The number of mesh layers, the volume fraction of reinforcement, and the kind of reinforcing materials are the primary factors that vary. This article presents the outcomes of a study that examined the experimental and numerical performance of ferrocement reinforced concrete I-beams with and without openings reinforced with welded steel mesh and tensar mesh separately. Utilizing ANSYS-16.0 software, nonlinear finite element analysis (NLFEA) was applied to illustrate how composite RC I-beams with openings behaved. In addition, a parametric study is conducted to explore the variables that can most significantly impact the mechanical behavior of the proposed model, such as the number of openings. The FE simulations produced an acceptable degree of experimental value estimation, as demonstrated by the obtained experimental and numerical results. It is also noteworthy to demonstrate that the strength gained by specimens without openings reinforced with tensar meshes was, on average, 22% less than that of specimens reinforced with welded steel meshes. For specimens with openings, this value is become on average 10%.

Positional change in mandibular condyle in facial asymmetric patients after orthognathic surgery: cone-beam computed tomography study

  • Choi, Byung-Joon;Kim, Byung-Soo;Lim, Ji-Min;Jung, Junho;Lee, Jung-Woo;Ohe, Joo-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.13.1-13.8
    • /
    • 2018
  • Background: We evaluated change in the mandibular condyle after orthognathic surgery using cone-beam computed tomography (CBCT) in patients with facial asymmetry. Methods: Thirty patients with skeletal class III malocclusion and mandibular prognathism or facial asymmetry were classified into two groups according to the amount of menton deviation (MD) from the facial midline on anteroposterior (AP) cephalogram: group A (asymmetry, MD ≥ 4 mm; n = 15) and group B (symmetry, MD < 4 mm; n = 15). Position and angle of condylar heads on the axial, sagittal, and coronal views were measured within 1 month preoperatively (T0) and postoperatively (T1) and 6 months (T2) postoperatively. Results: On axial view, both groups showed inward rotation of condylar heads at T1, but at T2, the change was gradually removed and the condylar head returned to its original position. At T1, both groups showed no AP condylar head changes on sagittal view, although downward movement of the condylar heads occurred. Then, at T2, the condylar heads tended to return to their original position. The change in distance between the two condylar heads showed that they had moved outward in both groups, causing an increase in the width between the two heads postoperatively. Analysis of all three-dimensional changes of the condylar head positions demonstrated statistically significant changes in the three different CBCT views in group B and no statistically significant changes in group A. Conclusions: There was no significant difference between the two groups in condylar head position. Because sagittal split ramus osteotomy can be performed without significant change in symmetrical and asymmetrical cases, it can be regarded as an effective method to stabilize the condylar head position in patients with skeletal class III malocclusion and mandibular prognathism or facial asymmetry.

초간편 강합성 바닥판 신형식 전단연결재의 전단내력 평가 (An Evaluation on the Shear Strength of New Type Shear Connectors for a Simple Steel-Concrete Composite Deck)

  • 윤기용;김상섭;한득천
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.519-528
    • /
    • 2008
  • 초간편 강합성 바닥판은 H형강을 거더로 활용하면서 교량가설시 H형강의 횡-비틀림 좌굴을 방지하고 공기를 단축시키기 위하여 개발하였다. 또한 초간편 강합성 바닥판과 H형강 거더의 합성거동을 확보하기 위하여 사용되는 전단연결재를 초간편 강합성 바닥판의 강판과 H형강 거더의 연결방식에 따라 연결볼트를 길게 뽑아 스터드를 대체하여 전단연결재로 사용하는 방식과 유공I형강을 전단연결재로 활용하는 방식으로 개발하였다. 본 연구에서는 이렇게 개발한 신형식 전단연결재에 대한 전단내력 평가를 위하여 Push-Out 실험을 실시하고, 기존 전단연결재의 전단내력 평가식과 비교 분석하였다. Push-Out 실험을 통하여 연결볼트는 스터드와 같은 거동을 하는 것으로 확인하였으며, 도로교 설계기준의 전단내력 평가식은 지름이 큰 연결볼트의 전단내력을 과대평가하는 것으로 나타났다. 용접량의 변화에 따른 유공I형강의 Push-Out 실험에서는 용접량이 적은 경우에는 용접부의 전단내력이 지배하였으나, 용접량이 일정정도 이상인 경우에는 일정한 전단내력을 발휘하는 것으로 나타났다.