• Title/Summary/Keyword: Splinting

Search Result 110, Processing Time 0.028 seconds

Stability of periodontally compromised teeth after splint and non-surgical therapy: two cases followed-up for 1 to 3 years (Splint 및 비외과적 치주치료를 통하여 치주질환에 이환된 치아의 안정화 증례 보고)

  • Kim, Yeon-Tae;Park, Ye-Sol;Kim, Do-Hyung;Jeong, Seong-Nyum;Lee, Jae-Hong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.338-344
    • /
    • 2018
  • This article describes cases of applying non-surgical treatment including scaling and root planing, occlusal adjustment and tooth splinting of periodontally compromised lower anterior incisors Clinical and radiographic evaluations were performed over a 1-3-year period. All clinical parameters and radiographic bone levels improved in both cases. Dramatic regeneration of alveolar bone and lamina dura were observed on radiographic images, and no specific complications occurred during the follow-up period. Within the limitations of this study, these cases demonstrated the possibility of tooth rescue through non-surgical treatment and splinting of periodontally compromised teeth typically considered for extraction.

Evidence-based management of isolated dentoalveolar fractures: a systematic review

  • Samriddhi Burman;Babu Lal;Ragavi Alagarsamy;Jitendra Kumar;Ankush Ankush;Anshul J. Rai;Md Yunus
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.3
    • /
    • pp.123-133
    • /
    • 2024
  • Dentoalveolar (DA) trauma, which can involve tooth, alveolar bone, and surrounding soft tissues, is a significant dentofacial emergency. In emergency settings, physicians might lack comprehensive knowledge of timely procedures, causing delays for specialist referral. This systematic review assesses the literature on isolated DA fractures, emphasizing intervention timing and splinting techniques and duration in both children and adults. This systematic review adhered to PRISMA guidelines and involved a thorough search across PubMed, Google Scholar, Semantic Scholar, and the Cochrane Library from January 1980 to December 2022. Inclusion and exclusion criteria guided study selection, with data extraction and analysis centered on demographics, etiology, injury site, diagnostics, treatment timelines, and outcomes in pediatric (2-12 years) and adult (>12 years) populations. This review analyzed 26 studies, categorized by age into pediatrics (2-12 years) and adults (>12 years). Falls were a common etiology, primarily affecting the anterior maxilla. Immediate management involved replantation, repositioning, and splinting within 24 hours (pediatric) or 48 hours (adult). Composite resin-bonded splints were common. Endodontic treatment was done within a timeframe of 3 days to 12 weeks for children and 2-12 weeks for adults. Tailored management based on patient age, tooth development stage, time elapsed, and resource availability is essential.

A Clinical Study on the Etched Resin Bonded Retainer for Fixed Bridgework (Etched Metal Resin Bonded Retainer에 관한 임상적 연구)

  • Yang, Jae-Ho
    • The Journal of the Korean dental association
    • /
    • v.21 no.5 s.168
    • /
    • pp.395-402
    • /
    • 1983
  • The purpose of this study was to apply the etched metal ceramometal retainer using a composite resin and acid-etch procedure with minimal tooth reduction of abutments for the replacement of one missing anterior or posterior tooth. Author obtained the following conclusions. 1. conservation of tooth structure and minimal chair time and patient expense were the primary advantages of etched metal retainer. 2. This fixed partial denture permitted good esthetic results. 3. This retainer was successfully applied for the replacement of one missing anterior or posterior tooth. 4. Proper retainer etching ws an important procedure. 5. Etched castings could be applied to periodontal splinting and post orthodontic fixation.

  • PDF

Intravenous catheter flanges as an external nasal stent: a novel technique

  • Shibani A. Nerurkar;Subramania Iyer;Arjun Krishnadas;Pramod Subash
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.2
    • /
    • pp.116-120
    • /
    • 2024
  • External nasal splints are commonly used for immobilization following nasal fracture reduction or rhinoplasty procedures. The literature documents the use of various materials like thermoplastic materials, aluminum, Orthoplast, fiberglass, plaster of Paris, and polyvinyl siloxane. These materials are bulky, time-consuming, expensive, and cumbersome to use, and have been associated with complications including contact dermatitis and epidermolysis. Furthermore, they cannot be retained if the situation warrants prolonged stabilization and immobilization. We introduce a new technique using readily available scalp vein catheter flanges as an external nasal stent. The technique is easy to master, inexpensive, and limits edema and ecchymosis, while stabilizing the reconstructed nasal skeleton in position during the healing period.

Radiographic evaluation of computer aided design/computer aided manufacturing (CAD/CAM) customized abutment of implant (CAD/CAM으로 제작된 임플란트 맞춤형 지대주의 방사선학적 평가)

  • Yun, Tae-Gyeong;Lee, Gyeong-Je;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.258-263
    • /
    • 2017
  • Purpose: In this study, the retrospective radiographic study is executed to evaluate amount of bone loss of various conditions in patients using customized abutment for 4 years of follow-up. Materials and methods: The subjects of this study were implant fixed dental prosthesis using CAD/CAM customized abutments. CAD/CAM customized abutment and fixed dental prosthesis were manufactured by the Prosthodontics Department of Chosun University Dental Hospital from August 1, 2011 to July 31, 2012. Radiological assessments were performed on the patients who were treated by the fixed prosthodontics. After each treatment, a retrospective study was performed for a total of 4 years at 3 months, 6 months, 1 year, 2 years, 3 years, and 4 years. Results: As a result of the study, the customized abutment using CAD/CAM showed less bone loss than the results of existing research. There was no statistically significant differences at alveolar bone loss between splinting group and non-splinting group (respectively 0.27 mm, 0.5 mm). Also, there were statistically significant differences at alveolar bone loss in mx. anterior, mx. posterior, mn. anterior and mn. posterior part (respectively 1.37 mm, 0.39 mm, 0.00 mm, 0.30 mm). Conclusion: The customized abutment using CAD/CAM showed less bone loss than the results of existing research, there were statistically significant differences at alveolar bone loss in implant positions.

Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease

  • Kim, Dae-Hyun;Kim, Hyun Ju;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.103-113
    • /
    • 2018
  • Purpose: The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. Methods: This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. Results: A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference (P<0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P=0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P=0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. Conclusions: IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

Retrospective Clinical Study of Immediate or Early Loading of Implants (Original Article 1 - 즉시 혹은 조기하중 임프란트에 관한 후향적 연구)

  • Lee, Seong-Yeon;Kim, Young-Kyun;Yun, Pil-Young;Yi, Yang-Jin;Yeo, In-Sung
    • The Journal of the Korean dental association
    • /
    • v.48 no.2
    • /
    • pp.119-126
    • /
    • 2010
  • Introduction. In this study, we applied the immediate loading to implant using temporary prosthesis, and compared the treatment results by each placement site, amongst pre-loading period. The study was intended to search for occurrence of complications and the amount of marginal bone resorption. Materials and Methods. We retrospectively reviewed the medical records of 99 cases of implants from 29 patients who were treated at Seoul National University Bundang Hospital from September 2003 to September 2008. We grouped all the cases by placement arches and pre-loading periods, and subdivided each group by placement site(anterior/posterior), type of prosthesis(full-mouth cross splinting/Partial multiple splinting, Single). Results. In the cases of anterior maxilla, the average amounts of marginal bone resorption showed $1.71{\pm}0.71mm$ in group 1, and $1.44{\pm}0.69mm$ in group 2, which means they revealed no statistically significant difference between group 1 and group 2(p=0.646). In the cases of posterior maxilla, the average amounts of marginal bone resorption showed $1.25{\pm}0.72mm$ in group 1, and $1.14{\pm}1.15mm$ in group 2, which means they were not statistically significant. In the cases of anterior mandible, there was no cases classified as group 4, but the average amounts of marginal bone resorption in group 3 showed $1.38{\pm}0.79mm$. In the cases of posterior mandible, Group 3 showed $1.39{\pm}0.64mm$, and group 4 showed $1.84{\pm}1.19mm$ as amounts of marginal bone resorption, which means they revealed no statistically significant difference between group 3 and group 4(P=0.210). The survival rate of group1 was 97.14%, 92.1% of group3, and 100% of group 2 and group4. According to each type of prosthesis, each average amount of marginal bone resorption revealed no statistically significant difference in maxi11a(p=0.575) in mandible(p=0.206). Conclusion. It is concluded that the marginal bone resorption and the rate of complications might not be affected by placement sites and pre-loading periods. The marginal bone resorption and the rate of complications might vary as different bone quality of placement site and implant system, diameter, length, etc. It is suggested that the proper placement of immediate loading implants decreases the whole treatment period and any inconvenience occurred to patients.

CONSERVATIVE APPROACH ON THE SEVERELY DISPLACED ROOT FRACTURE OF PRIMARY INCISORS : CASE REPORT (심하게 변위된 유전치 치근파절의 보존적 접근)

  • Kim, Jee-Young;Lee, Kwang-Hee;Kim, Dae-Eop;Ra, Ji-Young;Lee, Dong-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.571-577
    • /
    • 2008
  • Root fracture of primary teeth is relatively uncommon because the more pliable alveolar bone allows displacement of the tooth. Root fracture of primary teeth is occupied $2{\sim}7%$ in trauma pattern of primary teeth. A horizontal root fracture is classified based on the location of the fracture in relation to the root tip : the apical third, middle third, or cervical third of the root. The prognosis worsens the further cervically the fracture has occurrer. Root fracture of primary teeth should be treated by splinting the incisor to the adjacent normal teeth with a resin-wire splint for $8{\sim}12$ weeks. However, if a portion of the root is abscessed or extremely mobile, it can be extracted, and the remaining root fragment will resorb normally. For coronal third fracture in primary teeth, the coronal third is extracted, leaving the apical portion of the root to resorb normally. These root fracture cases of primary teeth were treated by resin-wire splinting despite extremely mobile coronal fragment. Even though they seems like healing well, They need to be monitored regularly until their successors erupt.

  • PDF

A Comparative Study of Facemask Therapy with Two Types of Bonded Expander (Bonded expander 형태에 따른 facemask의 치료 효과 비교연구)

  • Lee, Eunha;Park, Kitae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.4
    • /
    • pp.298-305
    • /
    • 2014
  • The purpose of this study is to evaluate the effects of facemask therapy in patients with Class III malocclusion with two types of bonded expanders covering different numbers of anchored teeth and to compare the anchorage value of two types of bonded expander. Eighteen subjects with Class III malocclusion in early mixed dentition were included in this study, and subjects were divided into two groups based on the number of teeth covered by bonded expander: group 1 (splinting four teeth on each side, 9 subjects) and group 2 (splinting three teeth on each side, 9 subjects). Lateral cephalograms were obtained and assessed before (T1) and after (T2) the treatment. The facemask therapy showed skeletal effects including anterior movement of maxilla and backward rotation of mandible in both groups, with no significant differences between groups. Mesial movement of maxillary molars which indicates anchorage loss of the bonded expander was found in both groups, but significantly larger mesial movement was found in group 2 than in group 1. In conclusion, the value of anchorage was different according to the number of teeth covered by bonded expander as an intraoral anchorage of facemask, but there were no significant differences in skeletal effects.

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).