• Title/Summary/Keyword: Splinted

Search Result 72, Processing Time 0.024 seconds

Torque control during lingual anterior retraction without posterior appliances

  • Mo, Sung-Seo;Kim, Seong-Hun;Sung, Sang-Jin;Chung, Kyu-Rhim;Chun, Yun-Sic;Kook, Yoon-Ah;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.43 no.1
    • /
    • pp.3-14
    • /
    • 2013
  • Objective: To evaluate the factors that affect torque control during anterior retraction when utilizing the C-retractor with a palatal miniplate as an exclusive source of anchorage without posterior appliances. Methods: The C-retractor was modeled using a 3-dimensional beam element (0.9-mm-diameter stainless-steel wire) attached to mesh bonding pads. Various vertical heights and 2 attachment positions for the lingual anterior retraction hooks (LARHs) were evaluated. A force of 200 g was applied from each side hook of the miniplate to the splinted segment of 6 or 8 anterior teeth. Results: During anterior retraction, an increase in the LARH vertical height increased the amount of lingual root torque and intrusion of the incisors. In particular, with increasing vertical height, the tooth displacement pattern changed from controlled tipping to bodily displacement and then to lingual root displacement. The effects were enhanced when the LARH was located between the central and lateral incisors, as compared to when the LARH was located between the lateral incisors and canines. Conclusions: Three-dimensional lingual anterior retraction of the 6 or 8 anterior teeth can be accomplished using the palatal miniplate as the only anchorage source. Using LARHs at different heights or positions affects the quality of torque and intrusion.

TOOTH REPLANTATION AFTER TRAUMATIC AVULSION: A 8-YEAR FOLLOW UP. (재식된 상악 중절치의 장기간에 걸친 추적례)

  • Lee, Dong-Woo;Kwak, Ji-Youn;Kim, Sung-Oh;Choi, Byung-Jai;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.729-733
    • /
    • 2004
  • Tooth avulsion usually causes inflammatory root resorption and ankylosis, and ankylosis cause severe functional and esthetic problems, especially in childhood. A 7-year-old female visited the Dept. of Pediatric Dentistry, Yonsei University with the chief complaint of avulsive trauma to the upper right incisor which was left dry for 40 minutes. Tooth was irrigated with saline and replanted immediately and splinted. Anti bacterial agent and anti inflammatory agent were prescribed. After 4 months of replantation slight external root resorption and apical radiolucency was seen at radiographic examination, therfore pulp extirpation and calcium hydroxide($Vitapex^{TM}$) canal filling were carried out. After 16 months, root canal was filled with gutta-percha, and bleaching treatment was done. Treatment results were satisfactory both esthetically and functionally for 8 years and 5 months.

  • PDF

Effect of nicotine on orthodontic tooth movement and bone remodeling in rats

  • Lee, Sung-Hee;Cha, Jung-Yul;Choi, Sung-Hwan;Kim, Baek-il;Cha, Jae-Kook;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.51 no.4
    • /
    • pp.282-292
    • /
    • 2021
  • Objective: To quantitatively analyze the effect of nicotine on orthodontic tooth movement (OTM) and bone remodeling in rats using micro-computed tomography and tartrate-resistant acid phosphatase immunostaining. Methods: Thirty-nine adult male Sprague-Dawley rats were randomized into three groups: group A, 0.5 mL normal saline (n = 9, 3 per 3, 7, and 14 days); group B, 0.83 mg/kg nicotine (n = 15, 5 per 3, 7, and 14 days); and group C, 1.67 mg/kg nicotine (n = 15, 5 per 3, 7, and 14 days). Each animal received daily intraperitoneal injections of nicotine/saline from the day of insertion of identical 30-g orthodontic force delivery systems. A 5-mm nickel-titanium closed-coil spring was applied between the left maxillary first molar (M1) and the two splinted incisors. The rate of OTM and volumetric bone changes were measured using micro-computed tomography. Osteoclasts were counted on the mesial alveolar bone surface of the distobuccal root of M1. Six dependent outcome variables, including the intermolar distance, bone volume fraction, bone mineral density, trabecular thickness, trabecular volume, and osteoclast number, were summarized using simple descriptive statistics. Nonparametric Kruskal-Wallis tests were used to evaluate differences among groups at 3, 7, and 14 days of OTM. Results: All six dependent outcome variables showed no statistically significant among group-differences at 3, 7, and 14 days. Conclusions: The findings of this study suggest that nicotine does not affect OTM and bone remodeling, although fluctuations during the different stages of OTM in the nicotine groups should be elucidated in further prospective studies.

Detachable zirconia prosthesis using Milled bar and ADD-TOC attachment in partial edentulous mandible: A case report (하악 부분 무치악 환자에서 Milled-bar와 ADD-TOC 부착 장치를 이용한 탈착 가능한 지르코니아 보철물 수복 증례)

  • Min-Sung Sohn;Jung-Bo Huh
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.90-99
    • /
    • 2023
  • Implant overdentures are widely used as a treatment method to restore oral function in completely edentulous or partially edentulous patients with severe bone resorption. Using a milled bar, it is mechanically advantageous as the implant fixtures are splinted. Applying additional attachments to the bar has the advantage of dispersing the stress applied to the implant. In this case, a patient who used implant overdentures using 4 implants wanted to fabricate a new prosthesis due to repeated fractures of the denture and weakened retention. Milled bar with ADD-TOC attachment and zirconia prosthesis were fabricated by CAD-CAM method and mechanically and aesthetically satisfactory results were obtained.

Finite Element Analysis of Stress Distribution on Telescopic System for Mandibular Implant Supported Overdenture (이중관 구조 하악 임플랜트 피개의치의 응력 분포에 관한 유한요소법적 분석)

  • Oh, Jung-Ran;Woo, Yi-Hyung;Lee, Sung-Bok;Bak, Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.359-371
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the stress distribution in mandibular implant overdentures with telescopic crowns compared to bar attachment. Material and methods: Three-dimensional finite element models consisting of the mandibular bone, 4 implants, and primary bar-splinted superstructure or secondary splinted superstructure with telescopic crowns were created. Vertical and oblique loads were directed onto the occlusal areas of the superstructures to simulate the maximal intercuspal contacts and working contacts such as group function occlusion. Maximum stress and stress distribution were analysed in mandibular bone, implant abutments, and superstructures. Results: 1. In comparison of von Mises stress on mandibular bone, telescopic overdenture had a little lower stress values in vertical load and working side load except oblique load. In the mandible, the telescopic overdenture distributed more uniform stress than the bar overdenture. 2. In comparison of von Mises stress on implant abutments, telescopic overdenture had much lower stress values in all load conditions. In implant abutments, the telescopic overdenture distributed stress similar to the bar overdenture. Stress was concentrated on the distal surfaces of the posterior implant abutments in both mandibular overdentures. 3. In comparison of von Mises stress on superstructures, the telescopic overdenture had much more stress values in all load conditions. However, the telescopic overdenture distributed more uniform stress on superstructure than the bar overdenture. In the bar overdenture, stress was concentrated on each cental area of bar structures and connected area between implant abutments and bar structures. Conclusion: In the results of this study, the telescopic overdenture had lower stress values than the bar overdenture in mandibular bone and implant abutments, but more stress values in superstructures. However, if optimal material was selected in making superstructures, the telescopic overdenture was compared to the bar overdenture in stress distribution.

Clinical evaluation of the removable partial dentures with implant fixed prostheses (임플란트 고정성 보철물을 이용한 가철성 국소의치의 합병증에 관한 임상적 평가)

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.239-245
    • /
    • 2016
  • Purpose: The purpose of this study was to identify clinical complications in removable partial denture (RPD) with implant-supported surveyed prostheses, and to analyze the factors associated with the complications such as location of the implant, splinting adjacent prostheses, the type of retentive clasps, Kennedy classification, and opposing dentition. Materials and Methods: A retrospective clinical study was carried out for 11 patients (7 male, 4 female), mean age of 67.5, who received RPD with Implant-supported surveyed prostheses between 2000 and 2016. The mechanical complications of 11 RPDs and 37 supporting implant prostheses and the state of natural teeth and peripheral soft tissue were examined. Then the factors associated with the complications were analyzed. Results: The average of 3.4 implant-supported prostheses were used for each RPD. Complications found during the follow-up period of an average of 42.1 months were in order of dislodgement of temporary cement-retained prostheses, opposing tooth fracture/mobility, screw fracture/loosening, clasp loosening, veneer porcelain fracture, marginal bone resorption and mobility of implant, artificial tooth fracture. Complications occurred more frequently in anterior region compared to posterior region, non-splinted prostheses compared to splinted prostheses, surveyed prostheses applied by wrought wire clasp compared to other clasps, and natural dentition compared to other removable prostheses as opposing dentition. There were no significant differences in complications according to the Kennedy classification. Conclusion: All implant-assisted RPD functioned successfully throughout the follow-up. However, further clinical studies are necessary because the clinical evidences are still not enough to guarantee the satisfactory prognosis of implant-assisted RPD for long-term result.

Detorque values of abutment screws in a multiple implant-supported prosthesis (다수 임플란트 지지 보철물에서 지대주 나사의 풀림 토크값에 대한 연구)

  • Lee, Ju-Ri;Lee, Dong-Hwan;Hwang, Jae-Woong;Choi, Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.280-286
    • /
    • 2010
  • Purpose: This study evaluated the detorque values of screws in a multiple implant-supported superstructure using stone casts made with 2 different impression techniques. Material and methods: A fully edentulous mandibular master model and a metal framework directly connected to four implants (Br${\aa}$nemark $System^{(R)}$; Nobel Biocare AB) with a passive fit to each other were fabricated. Six experimental stone casts (Group 1) were made with 6 non-splinted impressions on a master cast and another 6 experimental casts (Group 2) were made with 6 acrylic resin splinted impressions. The detorque values of screws ($TorqTite^{(R)}$ GoldAdapt Abutment Screw; Nobel Biocare AB) were measured twice after the metal framework was fastened onto each experimental stone cast with 20 Ncm torque. Detorque values were analyzed using the mixed model with the fixed effect of screw and reading and the random effect of model for the repeated measured data at a .05 level of ignificance. Results: The mean detorque values were 7.9 Ncm (Group 1) and 8.1 Ncm (Group 2), and the mean of minimum detorque values were 6.1 Ncm (Group 1) and 6.5 Ncm (Group 2). No statistically significant differences between 2 groups were found and no statistically significant differences among 4 screws were found for detorque values. No statistically significant differences between 2 groups were also found for minimum detorque values. Conclusion: In a multiple external hexagon implant-supported prosthesis, no significant differences between 2 groups were found for detorque values and for minimum detorque values. There seems to be no significant differences in screw joint stability between 2 stone cast groups made with 2 different impression techniques.

Stress distribution in bone surrounding maxillary molar implants under different crown-to-fixture ratio: A 3D FEM analysis (치관/고정체 비에 따른 상악 구치부 임플란트 주변골의 응력 분포에 대한 3차원 유한요소법적 분석)

  • Park, Jong-Chan;Shin, Sang-Wan;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.479-489
    • /
    • 2008
  • Statement of the problem: Under anatomical limitations on maxillary posterior region, a poor crown-to root ratio acting on dental implants can result in undesirable stress in surrounding bone, which in turn can cause bone defects and eventual failure of implants. Purpose: The purpose is to compare stress distribution due to different crown-root ratio and effect of splinting between natural teeth and implants in maxillary molar area under different loads. Material and methods: Analysis of stress arising supporting bone of the natural teeth and the implant was made with 3-dimensional finite element method. The model simulated naturel teeth was made with 2nd premolar and 1st molar in the maxillary molar region (Model T). The model simulated implants placed on same positions with two parallel implants of Straumann Dental Implant cemented abutment (Model I). Each model was designed in different crown-root ratio (0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it non-splinted or splinted. After that, 300 N force was loaded to each model in five ways (Load 1: middle of occlusal table, Load 2: middle of buccal cusp, Load 3: middle of lingual cusp, Load 4: horizontal load to buccal cusp of anterior abutment only, Load 5: horizontal load to middle of buccal cusp of each abutment), and stress distribution was analyzed. Results and conclusion: On all occasions, stress was concentrated at the cervical region of the implant. Under load 1, 2 and 3, stress was not increased even when crown-root ratio increases, but under load 4 and 5, when crown-root ratio increases, stress also increased. There was difference in stress values between natural teeth and implants when crown-root ratio gradually increases; In case of natural teeth, splinting decreased stress under vertical and horizontal loads. In case of implants, splinting decreased stress under vertical loads 1,2 and 3, but increased maximal stress under loads 2 and 3. Under horizontal loads, splinting decreased stress, however the effect of splinting decreased under load 5 than load 4. Furthermore, the stress was increased, when crown-root ratio is 1.25:1. Clinical implications: This limited finite element study suggests that the stress on supporting bone may be increased under non-axial loads and poor crown-root ratio. Under poor crown-root ratio, excessive stress was generated at the cervical region of the implant, and decreased splinting effect for stress distribution, which can be related to clinical failure.

BIOMECHANICS OF ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES UNDER UNILATERAL LOADING

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Jeong-Taek;Roh, Hyun-Ki;Kim, Hyo-Jin;Lee, Seok-Hyung;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.753-759
    • /
    • 2007
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress under unilateral loading specially. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs under unilateral loading, using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1: Clasp-retained mandibular removable partial denture with unsplinted abutments Group 2: Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge. Group 3: Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm dose to the abutments. Two unilateral vertical experimental loadings (30N and 100N) were applied subsequently via miniature load cell that were placed at mandibular left first molar region. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Tukey test was used as post hoc comparisons. Results. The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Strain values increased as the applied load in increased from 30N to 100N (p<.05) except for right side in group 1. Under 30N loading, in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 100N loading in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 30N loading, group 2 and 3 showed higher strain values in right side than in left side. Under 100N loading, right side strain values were higher than left side ones for all groups. Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments under unilateral loading. Bar-retained removable partial denture showed the lowest strain of three groups, and compressive nature.

THE THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PARTIALLY EDENTULOUS IMPLANT PROSTHESIS WITH VARYING TYPES OF NON-RIGID CONNECTION (부분 무치악 임플랜트 보철 수복시 자연치와의 비고정성 연결형태에 따른 3차원 유한요소법적 연구)

  • Lee, Seon-A;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.101-124
    • /
    • 1996
  • In this study, we designed the finite element models of mandible with varying their connecting types between the prosthesis on implant fixture and 2nd premolar, which were free-standing case(Mf), precision attachment case(Mp), semiprecision attachment case(Ms) and telescopic case(Mt). The basic model of the designed finite element models, which contained a canine and the 1st & 2nd premolar, was implanted in the edentulous site of the 1st & 2nd molar by two implant fixtures. We applied the load in all models by two ways. A vertical load of 200N was applied at each central fossa of 2nd premolar and 1st implant. A tilting load of 20N with inclination of $45^{\circ}$ to lingual side was applied to buccal cusp tips of each 2nd premolar and 1st implant. And then we analyzed three-dimensional finite element models, making a comparative study of principal stress and displacement in four cases respectively. Three-dimensional finite element analysis was performed for the stress distribution and the displacement using commercial software(IDEAS program) for SUN-SPARC workstation. The results were as follows : 1 Under vertical load or tilting load, maximum displacement appeared at the 2nd premolar. Semiprecision case showed the largest maximum displacement, and maximum displacement reduced in the order of precision attachment, free-standing and telescopic case. 2. Under vertical load. the pattern of displacement of the 1st implant appeared mesio-inclined because of the 2nd implant splinted together. But displacement pattern of the 2nd premolar varied according to their connection type with prosthesis. The 2nd premolar showed a little mesio-inclined vertical displacement in case of free-standing and disto-inclined vertical displacement due to attachment in case of precision and semiprecision attachment. In telescopic case, the largest mesio-inclined vertical displacement has been shown, so, the 1st premolar leaned mesial side. 3. Under tilting load, The pattern of displacement was similar in all four cases which appeared displaced to lingual side. But, the maximum displacement of 2nd premolar appeared larger than that of the first implant. Therefore, there was large discrepancy in displacement between natural tooth and implant during tilting load. 4. Under vertical load, the maximum compressive stress appeared at the 1st implant's neck. Semiprecision attachment case showed the largest maximum compressive stress, and the maximum compressive stress reduced in the order of precision attachment, telescopic and free-standing case. 5 Under vertical load, the maximum tensile stress appeared at the 2nd implant's distal neck. Semiprecision attachment case showed the largest maximum tensile stress, and the maximum tensile stress reduced in the order of precision attachment, telescopic and free-standing case. 6. Under vertical load or tilting load, principal stress appeared little between natural tooth & implant in free-standing case, but large principal stress was distributed at upper crown and distal contact site of the 2nd premolar in telescopic case. Principal stress appeared large at keyway & around keyway of distal contact site of the 2nd premolar in precision and semiprecision attachment case, appearing more broad and homogeneous in precision attachment case than in semiprecision attachment case.

  • PDF