• Title/Summary/Keyword: Spiral test

Search Result 193, Processing Time 0.028 seconds

Calculation Method of Constant Linear Velocity Spiral Path for Pin-on-disk Abrasion Test using a Hollow Type Rock Sample (중공형 암석시편의 Pin-on-disk 마모시험을 위한 등속도 나선경로 계산방법)

  • Kang, Hoon;Kim, Dae-ji;Song, Changheon;Oh, Joo-Young;Cho, Jung-Woo
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.394-403
    • /
    • 2020
  • This technical note describes the calculation method of continuous constant linear velocity Archimedean spiral paths which are applied to the pin-on-disk abrasion test. Approximate constant linear velocity Archimedean spirals have unstable velocities in the very near region of the rotational origin. Thus, in this technical note, the offset distance from the rotational origin was given by using a hollow type rock sample to maintain the constant velocity during the test. Also, to connect the inward and outward spirals continuously, the information of start and end points were input on the next spiral path consecutively. Furthermore, the calculation program was developed to provide convenience for calculating constant linear velocity spirals according to the specimen dimension and abrasion test conditions.

The Effect Spiral Way Movement of a Trunk Exerts on the Movement Ability (체간의 나선방향운동이 운동능력에 미치는 효과)

  • Lee, In-Hak;Nam, Taek-Gil
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.2
    • /
    • pp.35-45
    • /
    • 2007
  • The purpose of this study was to examine spiral way movement of a trunk exerts on the movement ability. The details established to achieve for this article. This examination confirmed the weight, weight/height2 index, ratio of lumbar to pelvic, musculoskeletal quantity, push up for 2 minute, pitch a ball and voluntary isometric contraction with flexion and extension of knee joint of the subjects with spiral direct movement. Healthy eighteen subjects who understand fully the significance of procedure, consented to a plan, without neuromuscular disease were participated in two groups of experiment. The group were a spiral movement(9), rectilinear movement(9). Trunk movement tested 2 sessions of a spiral movement and rectilinear movement with a push up for 2 minute, 5days per a week, for the 4 weeks. This experiment tested 3 times with a sufficient rest for fatigue limitation. An analysis of the results used a paired samples t-test for difference from before and after experiment. The following results were obtained; At an internal change of the body, the musculoskeletal quantity was increased significantly to spiral movement group, but the weight was increased significantly, the musculoskeletal quantity was not significant to rectilinear movement. The movement ability evaluation for a external change was increased significantly in a push up for 2 minute, pitch a ball, isometric contraction with extension of knee joint of a spiral movement group, but a push up for 2 minute was increased significantly in a push up for 2 minute on the abdominal muscle training of a rectilinear movement group. As compared with a rectilinear movement, a spiral movement was more effect by cooperation with nerve and musculoskeletal system and an increase in movement ability was caused by learning acknowledgment, muscular reeducation. These results lead us to the conclusion that a spiral movement of trunk was more effect than a rectilinear movement, the coordination of nerve and musculoskeletal system was of importance of Multi-direction movement. Therefore, A further studies concerning the therapeutic exercise intervention and active-dynamic analysis could enhance the development of the most effect on the trunk.

  • PDF

Thermal Performance of a Spirally Coiled Finned Tube Heat Exchanger Under Wet-Surface Conditions

  • Wongwises Somchai;Naphon Paisarn
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.212-226
    • /
    • 2006
  • This paper is a continuation of the authors' previous work on spiral coil heat exchangers. In the present study, the heat transfer characteristics and the performance of a spirally coiled finned tube heat exchanger under wet-surface conditions are theoretically and experimentally investigated. The test section is a spiral-coil heat exchanger which consists of a steel shell and a spirally coiled tube unit. The spiral-coil unit consists of six layers of concentric spirally coiled finned tubes. Each tube is fabricated by bending a 9.6 mm diameter straight copper tube into a spiral-coil of four turns. The innermost and outermost diameters of each spiral-coil are 145.0 and 350.4 mm, respectively. Aluminium crimped spiral fins with thickness of 0.6 mm and outer diameter of 28.4 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Air and water are used as working fluids in shell side and tube side, respectively. The experiments are done under dehumidifying conditions. A mathematical model based on the conservation of mass and energy is developed to simulate the flow and heat transfer characteristics of working fluids flowing through the heat exchanger. The results obtained from the present model show reasonable agreement with the experimental data.

Design and Test of Vacuum Rotary Arc Gap Switch (Vacuum Rotary Arc Gap Switch의 설계 및 시험)

  • 서길수;황동원;이태호;황리호;김희진;이홍식;임근희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.

A Study on Seismic Performance of Spiral Prer (나선철근교각의 내진성능에 관한 연구)

  • 배성용;김광수;이형준;이재훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.363-368
    • /
    • 2000
  • The Korean Bridge Design Standard Specifications adopted the seismic design requirements in 1992. However, The current seismic design requirements for bridges are based on the USA seismic codes for sever earthquake. This provides the basic factors that affects the performance of spiral reinforced concrete piers for seismic loading, and The specimen tests are performed based on load-displacement, effective stiffness and displacement ductility, etc. The quasi-static test was adopted in order to investigate seismic performance of the spiral reinforced concrete pier specimens which had different transverse steel amount, spacing and longitudinal steel ratio under different axial load levels. This study is concluded that seismic design for transverse reinforcement content of spiral reinforced concrete column has influenced on axial load and effective stiffness etc.

  • PDF

Evaluation of the maneuverability of a real ship with flap rudder (Flap rudder를 이용한 조종성능 평가)

  • AHN, Jang-Young;KIM, Kwang-il;KIM, Min-Son;LEE, Chang-Heon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.56 no.2
    • /
    • pp.172-182
    • /
    • 2020
  • In order to offer specific information needed to assist in operation of a ship with same type rudder through evaluating the maneuverability of training ship A-Ra with flapped rudder, sea trials based full scale for turning test, zig-zag test with rudder angle 10° and 20°, and spiral test at service condition were carried out on starboard and port sides around Jeju Island according to the standards of maneuverability of IMO. As a result, the angular velocity of port turn was higher than that of starboard turn. Therefore, the size of turning circle was longer on the starboard side. In addition, variation of the transfer due to various factors was more stable than those of the others. In the Z-test results, the mean of 1st and 2nd overshoot angles were 9.8°, 6.3° and 15.3°, 9.2° respectively when the port and starboard was 10°; the 1st overshoot angle were 18°, 13.7° when using 20°. Her maneuverability index T' and K' can be easily determined by using a computer with the data obtained from Z-test where K' and T' are dimensionless constants representing turning ability and responsiveness to the helm, respectively. In the Z-test under flap rudder angle 10°, the obtained K' value covered the range of 2.37-2.87 and T' was 1.74-3.45. Under the flap rudder angle 20°, K' and T' value showed 1.43-1.63, 1.0-1.73, respectively. In the spiral test, the loop width was unstable at +0.3° and -0.5°-0.9° around the midship of flap rudder. As a result, course stability was comparatively good. From the sea trial results, training ship ARA met the present criterion in the standards of maneuverability of IMO.

Design of PIFA type Spiral Antenna for Vehicle RKE Reader (차량 RKE 리더기용 PIFA형 스파이럴 안테나의 설계)

  • Oh, Dong-Jun;Yun, Ho-Jin;Jeong, Bong-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.135-140
    • /
    • 2008
  • In this paper, the spiral antenna with the center frequencies of 315MHz, 433MHz, and 447MHz for RKE system of a vehicle is designed on PCB. The antenna is microstrip line-fed, and applied PIFA concept near the feeding part to easily tune center frequency and input impedance. The PIFA-type spiral antenna with the size of $30mm{\times}20mm$ is designed on printed PCB by considering the effect of circuits and components on PCB, ECU case and vehicle body. Also chip inductor inserted dual-band spiral antenna of 315MHz and 447MHz is designed. We found that the antenna designed on PCB satisfied the antenna specifications through measurement and field test.

  • PDF

Behavior of concrete columns confined with both steel angles and spiral hoops under axial compression

  • Zhou, Chunheng;Chen, Zongping;Shi, Sheldon Q.;Cai, Liping
    • Steel and Composite Structures
    • /
    • v.27 no.6
    • /
    • pp.747-759
    • /
    • 2018
  • This study proposed a new type of concrete column that was confined with both steel angles and spiral hoops, named angle-steel and spiral confined concrete (ASCC) column. A total of 22 ASCC stub columns were tested under axial compression to investigate their behavior. For a comparison, three angle-steel reinforced concrete (ARC) stub columns were also tested. The test results indicated that ASCC column had a superior mechanical performance. The strength, ductility and energy absorption were considerably increased due to the improvement of confinement from spiral hoops. The confinement behavior and failure mechanism of ASCC column were investigated by the analysis of failure mode, load-deformation curve and section-strain distribution. Parametric studies were carried out to examine the influences of different parameters on the axial compression behavior of ASCC columns. A calculation approach was developed to predict the ultimate load carrying capacity of ASCC columns under axial compression. It was validated that the predicted results were in well agreement with the experimental results.

Dismantled PD diagnosis on 6.6kV Stator Winding by Using Spiral Patch Antenna Sensor (분리된 6.6kV급 고정자 권선의 부분방전 측정을 위한 Spiral 패치 안테나 센서 적용 연구)

  • Lwin, Kyaw Soe;Shin, Dong-Hoon;Lim, Kwang-Jin;Yang, Hoon;Kong, Tae-Sik;Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.211-212
    • /
    • 2007
  • There have three kinds of partial discharge diagnosis testing: online, offline and dismantled testing on high voltage rotating machine. Our lab testing is dismantled testing, taking off pieces into individual parts of stator coil of high voltage rotating machine in laboratory. We investigate internal discharge, slot discharge, corona discharge and normal state on pre-made stator winding by using spiral patch antenna sensor. In this lab test we compare the experimental results of our spiral patch antenna sensor and reference commercial HFCT sensor.

  • PDF

Magnetic Actuator for a Capsule Endoscope Navigation System

  • Chiba, Atsushi;Sendoh, Masahiko;Ishiyama, Kazushi;Arai, Ken Ichi;Kawano, Hironao;Uchiyama, Akio;Takizawa, Hironobu
    • Journal of Magnetics
    • /
    • v.12 no.2
    • /
    • pp.89-92
    • /
    • 2007
  • The authors propose a magnetic actuator for use as a navigation system for capsule endoscopes. The actuator is composed of a capsule dummy, a permanent magnet inside the capsule, and an external spiral structure. The device rotates and propels wirelessly when exposed to an external rotational magnetic field. In this study we measured the effect of the spiral shape on the velocity and thrust force properties. According to our experimental results, the actuator obtained a maximum velocity and thrust force when the spiral angle was set at 45 degrees, the number of spirals was set at 4, and the spiral-height was set at 1-mmf. We also conducted a motion test in the large intestine of a pig placed on a 30 degrees slope. The actuator passed through a 700 mm length of the intestine in about 300 s. The device also managed to travel up and down the 30 degrees slope with no difficulty whatsoever. Our results demonstrate the great potential of this actuator for use as a navigation system for capsule endoscopes.