• Title/Summary/Keyword: Spiral drawing

Search Result 9, Processing Time 0.029 seconds

Drawing Process with Rotational Die for Forming Grooves in a Tube (돌기 튜브 성형을 위한 회전 금형 인발공정에 관한 연구)

  • Park, Joon-Hong;Byon, Sang-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.123-129
    • /
    • 2018
  • A rotational drawing die which can form a long tube with spiral grooves on the surface is presented. The main feature of the proposed die is a rotation insert that is embedded into the die container for the die to freely rotate with respect to the drawing centerline as the materials are drawn. We employed a three-dimensional finite element model to investigate the effects of the rotational die on the material filling of spiral grooves. The material used in the finite element analysis was stainless 304. We also performed a pilot drawing test to verify the usefulness of the proposed rotational drawing die. Results reveal that the material filling of spiral grooves by the proposed rotational drawing die was in good agreement for both the finite element analysis and the drawing test. We found that the underfill in a conventional drawing die was reduced in the proposed rotational drawing die.

Spiral Drawing-based Real-time Crystallization Mosaic Tchnique (나선 드로잉 기반 실시간 결정화 모자이크 기법)

  • Kim, Jae Kyoung;Kim, Young Ho;Park, Jin Wan
    • Journal of the Korean Society for Computer Game
    • /
    • v.31 no.4
    • /
    • pp.137-144
    • /
    • 2018
  • In the past, mosaics were made by laying cloth on the floor and manually tiling the tiles. However, due to recent developments in technology, the data storage method has evolved from analog to digital, so that image representation and conversion can be realized through computer. Also, various expression techniques of mosaic are developed, and it is also used as a method of art representation in digital. There are various studies on the production process of mosaic. The proposed method is a crystallization mosaic that spreads spirally in real time and uses 3D quartz as a tile element. Although existing researches are mostly focused on the purpose of rendering images in more detail, this technique combines untried spiral drawing and crystallization, and attempts to explore new expression techniques in 3D space by attempting a new mosaic method in 3D space. 'Spiral Crystallization Photo', based on this technique, was selected as Top27 in MWU Award 18 and exhibited at Unite Seoul 2018.

Android Smart Phone App for early diagnosis of Parkinson's Disease (파킨슨병 조기 진단을 위한 안드로이드 기반의 앱 개발)

  • Moon, Ho-Sang;Noh, Seung-Jae;Chung, Sung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.145-152
    • /
    • 2019
  • Parkinson's disease(PD) is one of the three major senile diseases and the incidence rate is increasing worldwide as the population ages. And as the disease progresses, time and economic costs increase, so it is important to understand the progress of the disease and to diagnose it early In this paper, we propose a method for pre-screening Parkinson's disease using a smartphone. The contents of the developed application are composed of tapping, tremor, spiral drawing, and gait based on Part III of the Unified Parkinson's Disease Rating Scale. This can be used to quantitatively diagnose Bradykinesia, Tremor and Postural Instability, which are known as motility symptoms of Parkinson's disease, and to monitor the progress of symptoms. This method is expected to be useful for the diagnosis and treatment of Parkinson's disease.

Design of a 2.4GHz 2 stage Low Noise Amplifier for RF Front-End In a 0.35${\mu}{\textrm}{m}$ CMOS Technology

  • Kwon, Kisung;Hwang, Youngseung;Jung, Woong
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.11-15
    • /
    • 2002
  • 3 V, 2.46GHz Low Noise Amplifier (LNA) have been designed for standard 0.35$\mu\textrm{m}$ CMOS process with one poly and four metal layers. This design includes on-chip biasing, matching network and multilayer spiral inductors. The single-ended amplifier provides a forward gain of 20.5dB with a noise figure 3.35dB, and an IIP3 of -6dBm while drawing 59mW total Power consumption

  • PDF

A Study on Developing Ship's Turing Circles (선박의 선회권 작성에 관한 고찰)

  • Song, Kang-Sop;Hugh, Ihl
    • Journal of the Korean Institute of Navigation
    • /
    • v.3 no.1
    • /
    • pp.1-17
    • /
    • 1979
  • It is very important for both naval architects and ship's officers to know the maneuvering characteristics of their ships. As the abilities of a rudder which controlls a ship can be determined clearly by analyzing the results of Kempf's zig-zag maneuver and directional stability of a ship also known by Dieudonn spiral maneuver, the importance of turning test which takes much time is recently apt to be neglected. But because the test can be executed comparatively more simply than any other maneuvering tests, it gives some informations on the directional stability, and turning characteristics may be expressed simply by the results of the test, it is still often performed. In this paper several assumptions are made to simplify the turning motion of a ship. The equations of initial transient phase, the radius ofsteady turning circle, and the center of the steady turning point are derived by using the hydrodynamic derivatives. And then the approximate method of drawing the turning circle geometrically is suggested.

  • PDF

Effect of Vertically Rising Pressure Providing Spinal Canal Segment Motion on Symptom Relief in Patients with Parkinson's Disease (척추관 분절운동을 제공하는 수직 상승 압력이 파킨슨병 환자의 증상 완화에 미치는 영향)

  • Do-Hyun, Ahn;Hyeun-Woo, Choi;Kyung-Mi, Jung;Na-Young, Kim;Jong-Min, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.787-797
    • /
    • 2022
  • The purpose of this study was to confirm the reduction of pain and symptom relief of Parkinson's disease by vertically stimulating the spine through the application of a mechanical bed capable of thermal and massage stimulation. For this purpose, after confirming the segmental motion of the spine due to the use of a medical combination stimulation bed for Parkinson's disease patients, VAS, ODI, gait ability, and spiral drawing tests were performed, and the relationship between the variables was identified. In the 10-day visual analog scale and evaluation of low back pain dysfunction, the average trend of decreasing after bed use was confirmed. For walking ability, a decrease in the moving time and an increase in the moving distance were observed. In the spiral drawing test, the mean test time after using bed was significantly lower than before. As a result, it suggested the possibility of using it as an auxiliary method for recovery and pain relief of Parkinson's disease patients due to spinal segmental movement with mechanical heating and massage. However, this study is a preliminary study, and there is a small number of subjects, so additional research is needed that considers the number and condition of future subjects in detail.

A Digital Device-Based Method for Quantifying Motor Impairment in Movement Disorders (디지털 디바이스를 이용한 이상운동증에서의 운동손상 정량화 방법)

  • Bae, Suhan;Yun, Daeun;Ha, Jaekyung;Gwon, Daeun;Kim, Young Goo;Ahn, Minkyu
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.247-255
    • /
    • 2020
  • Accurate diagnosis of movement disorders is important for providing right patient care at right time. In general, assessment of motor impairment relies on clinical ratings conducted by experienced clinicians. However, this may introduce subjective opinions into scoring the severity of motor impairment. Digital devices such as table PC and smart band with accelerometer can be used for more accurate and objective assessment and possibly helpful for clinicians to make right decision of patient's states. In this study, we introduce quantification algorithms of motor impairment which uses the digital data acquired during four clinical motor tests (Line drawing, Spiral drawing, Nose to finger and Hand flip tests). The step by step procedure of quantifying metrics (Tremor Frequency, Tremor Magnitude, Error Distance, Time, Velocity, Count and Period) are provided with flowchart. The effectiveness of the proposed algorithm is presented with the result from simulated data (normal, normal with tremor and slowness, poor with tremor, poor with tremor and slowness).

Effects of Task and Part on Tremor Characteristics in Patients with Essential Tremor (본태성 진전 환자의 진전특성에 대한 수행과제 및 부위의 영향)

  • Heo, J.H.;Kim, J.W.;Kwon, Y.R.;Eom, Gwang-Moon;Kwon, D.Y.;Lee, C.N.;Park, K.W.;Manto, M.
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.15-20
    • /
    • 2016
  • Essential tremor is a neurological disorder with a tremor of the arms and hands. It is well known that essential tremor is characterized by the postural tremor and the action tremor. There has been no report on the quantitative difference in the characteristics of two tremor types. The purpose of this study was to investigate the possible difference in tremor characteristics of postural and action tremors. Seventeen patients with essential tremor ($68.9{\pm}7.9years$, 7 men, 10 women) participated in this study. Patients performed the tasks of postural maintenance (arms outstretched) and daily actions (spiral drawing). Three-axes (pitch, roll and yaw) gyro sensors were attached on index finger, back of hand and forearm, from which the segment and the joint angular velocities were calculated. Outcome measure was the tremor amplitude defined as the root-mean-square mean of the vector-sum angular velocity at segments and joints. Two-way ANOVA showed that task and joint had main factor on the tremor amplitude (p < 0.05). Post-hoc analysis revealed that tremor amplitude at the metacarpo-phalangeal joint was not affected by task (p > 0.05). However, tremor amplitude at the wrist joint differed among the tasks (p < 0.05), and it was greater in the action tasks than in postural task. Tremor was greater at finger segments than at hand and forearm and it increased in action tasks. The results of this study would be helpful for the understanding and task-specific treatments of the essential tremor.

ULTRAVIOLET COLOR - COLOR RELATION OF EARLY-TYPE GALAXIES AT 0.05

  • Lee, Chang-Hui;Jeong, Hyeon-Jin;O, Gyu-Seok;Jeong, Cheol;Lee, Jun-Hyeop;Kim, Sang-Cheol;Gyeong, Jae-Man
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.48.1-48.1
    • /
    • 2012
  • We present the ultraviolet (UV) color-color relation of early-type galaxies (ETGs) in the nearby universe (0.05 < z < 0.12) to investigate the properties of hot stellar populations responsible for the UV excess (UVX). The initial sample of ETGs is selected by the spectroscopic redshift and the morphology parameter from the SDSS DR 7, and then cross-matched with the GALEX far-UV (FUV) and near-UV (NUV) GR6 data. The cross-matched ETG sample is further classified by their emission line characteristics in the optical spectra into quiescent, star-forming, and active galactic nucleus categories. Contaminations from early-type spiral galaxies, mergers, and morphologically disturbed galaxies are removed by visual inspection. By drawing the FUV-NUV (as a measure of UV spectral shape) versus FUV-r (as a measure of UVX strength) diagram for the final sample of -3700 quiescent ETGs, we find that the "old and dead" ETGs consist of a well-defined sequence in UV colors, the "UV red sequence," so that the stronger UVX galaxies should have a harder UV spectral shape systematically. However, the observed UV spectral slope is too steep to be reproduced by the canonical stellar population models in which the UV flux is mainly controlled by age or metallicity parameters. Moreover, 2 mag of color spreads both in FUV-NUV and FUV-r appear to be ubiquitous among any subsets in distance or luminosity. This implies that the UVX in ETGs could be driven by yet another parameter which might be even more influential than age or metallicity.

  • PDF