• 제목/요약/키워드: Spinal implant

검색결과 42건 처리시간 0.025초

Reactive Oxygen Species and Nitrogen Species Differentially Regulate Neuronal Excitability in Rat Spinal Substantia Gelatinosa Neurons

  • Lee, Hae In;Park, A-Reum;Chun, Sang Woo
    • International Journal of Oral Biology
    • /
    • 제39권4호
    • /
    • pp.229-236
    • /
    • 2014
  • Reactive oxygen species (ROS) and nitrogen species (RNS) are implicated in cellular signaling processes and as a cause of oxidative stress. Recent studies indicate that ROS and RNS are important signaling molecules involved in nociceptive transmission. Xanthine oxidase (XO) system is a well-known system for superoxide anions ($O{_2}^{{\cdot}_-}$) generation, and sodium nitroprusside (SNP) is a representative nitric oxide (NO) donor. Patch clamp recording in spinal slices was used to investigate the role of $O{_2}^{{\cdot}_-}$ and NO on substantia gelatinosa (SG) neuronal excitability. Application of xanthine and xanthine oxidase (X/XO) compound induced membrane depolarization. Low concentration SNP ($10{\mu}M$) induced depolarization of the membrane, whereas high concentration SNP (1 mM) evoked membrane hyperpolarization. These responses were significantly decreased by pretreatment with phenyl N-tert-butylnitrone (PBN; nonspecific ROS and RNS scavenger). Addition of thapsigargin to an external calcium free solution for blocking synaptic transmission, led to significantly decreased X/XO-induced responses. Additionally, X/XO and SNP-induced responses were unchanged in the presence of intracellular applied PBN, indicative of the involvement of presynaptic action. Inclusion of GDP-${\beta}$-S or suramin (G protein inhibitors) in the patch pipette decreased SNP-induced responses, whereas it failed to decrease X/XO-induced responses. Pretreatment with n-ethylmaleimide (NEM; thiol-alkylating agent) decreased the effects of SNP, suggesting that these responses were mediated by direct oxidation of channel protein, whereas X/XO-induced responses were unchanged. These data suggested that ROS and RNS play distinct roles in the regulation of the membrane excitability of SG neurons related to the pain transmission.

Multidisciplinary Treatment of Persistent Nontuberculous Mycobacterial Spinal Hardware Infection with a Pedicled Superior Gluteal Artery Perforator Flap

  • Tuano, Krystle R.;Yang, Jerry H.;Kleck, Christopher J.;Mathes, David W.;Chong, Tae W.
    • Archives of Plastic Surgery
    • /
    • 제49권5호
    • /
    • pp.604-607
    • /
    • 2022
  • Nontuberculous mycobacterial hardware infections are extremely challenging to treat. Multidisciplinary care involving removal of infected hardware, thorough debridement, and durable soft tissue coverage in conjunction with antibiotic therapy is essential for successful management. This case report presents a patient with chronic mycobacterial spinal hardware infection that underwent successful treatment with aggressive serial debridements and reconstruction with a large pedicled superior gluteal artery perforator flap coverage.

Spinal Cord Stimulation in the Treatment of Postherpetic Neuralgia in Patients with Chronic Kidney Disease: A Case Series and Review of the Literature

  • Baek, In-Yeob;Park, Ju-Yeon;Kim, Hyae-Jin;Yoon, Ji-Uk;Byoen, Gyeong-Jo;Kim, Kyung-Hoon
    • The Korean Journal of Pain
    • /
    • 제24권3호
    • /
    • pp.154-157
    • /
    • 2011
  • Background: Postherpetic neuralgia (PHN) is usually managed pharmacologically. It is not uncommon for patients with chronic kidney disease (CKD) to suffer from PHN. It is difficult to prescribe a sufficient dose of anticonvulsants for intractable pain because of the decreased glomerular filtration rate. If the neural blockade and pulsed radiofrequency ablation provide only short-term amelioration of pain, spinal cord stimulation (SCS) with a low level of evidence may be used only as a last resort. This study was done to evaluate the efficacy of spinal cord stimulation in the treatment of PHN in patients with CKD. Methods: PHN patients with CKD who needed hemo-dialysis who received insufficient relief of pain over a VAS of 8 regardless of the neuropathic medications were eligible for SCS trial. The follow-up period was at least 2 years after permanent implantation. Results: Eleven patients received percutaneous SCS test trial from Jan 2003 to Dec 2007. Four patients had successfully received a permanent SCS implant with their pain being tolerable at a VAS score of less than 3 along with small doses of neuropathic medications. Conclusions: SCS was helpful in managing tolerable pain levels in some PHN patients with CKD along with tolerable neuropathic medications for over 2 years.

생체공학용 척추경 나사의 기계적 거동 예측 (Prediction of Mechanical Behaviors of Bio-mechanical Materials)

  • 박준식;최진화;조명우;최길운
    • 한국기계가공학회지
    • /
    • 제3권1호
    • /
    • pp.72-78
    • /
    • 2004
  • In this paper, mechanical behaviors of developed pedicle screw system, made of bio-mechanical materials(Ti-6Al-4V, Grade 5), ale predicted using FEM analysis. As a first step, morphologic construction of normal Korean spines and surgical operation convenience are considered to design optimum pedicle screw system. In this step, various design variables are considered as design parameters to develop optimized models. As a next step, tension and bending tests are performed to improve the structural performance of the developed system using finite element method. In this step, required Static compression and bending test specifications by ASTM F-04 25 04 01 are applied to understand the bio-mechanical behaviors of the designed spinal implant system under various load types. As the results of this research, it is possible to develop efficient pedicle screw system, having enough rigidity and fixation to stand any spinal damage under allowable stress conditions.

  • PDF

척추고정용 형상기억합금 동적안정기기의 생체역학적 성능 평가 (Biomechanical Evaluation of SMA Dynamic Stabilization for Spinal fusion)

  • 김윤혁;박원만;김경수;박형균;주증우;박경우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.517-518
    • /
    • 2006
  • In this study, a commercial fixation device, BioFlex, which was designed with shape memory alloy(SMA) for dynamic stabilization of spine was biomechanically evaluated. The finite element model of intact lumbar spine from L1 to S was developed using CT images. Also, low FE models of 2-level(L4-L5-S) and 3-level(L3-L4-L5-S) posteriori fixation using titanium(Ti) rod and BioFlex(SMA) rod. The rotations of bone segments in the intact model and four models were predicted. Although the rotations of the BioFlex fixation model were smaller than those of the intact model, they were relatively larger than those of Ti fixation. The present can be applied for not only evaluation of the stability of interbody fixator, but also development of new implant.

  • PDF

Interspinous Implant with Unilateral Laminotomy for Bilateral Decompression of Degenerative Lumbar Spinal Stenosis in Elderly Patients

  • Ryu, Sung-Joo;Kim, In-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권5호
    • /
    • pp.338-344
    • /
    • 2010
  • Objective : This study assessed the safety and efficacy of one level unilateral laminotomy bilateral decompression (ULBD) with the placement of a device for intervertebral assisted motion (DIAM) compared with one level ULBD only in elderly patients with degenerative lumbar spinal stenosis (DLSS). Methods : A non randomized prospective analysis was performed on 16 patients who underwent one level ULBD with DIAM (Group A) and 20 patients with one level ULBD only (Group B) between February 2007 and March 2008. Radiographic imaging, visual analog scale (VAS) and MacNab outcome scale were obtained before and after surgery at a mean interval of 21 months (range 17-27 months). Results : The disc height, interpedicular distance, slip distance and segmental lordotic angle were similar between two groups. In the group A, there was no significant difference between the pre- and post-operative imaging in terms of the sagittal balance and disc height. Both groups showed significant improvement in the clinical outcomes. In addition, there was significantly less low-back pain in the group A than in the group B at the last follow up, while the clinical improvement of the leg pain and MacNab outcome scale showed no significant difference in the two groups. There were no major complications or DIAM associated complications. Conclusion : ULBD with DIAM is a safe and efficacious treatment for selective elderly patients with DLSS, particularly for relieving low back pain comparing to ULBD. ULBD with DIAM did not alter the disc height or sagittal alignment at the mean 21 months follow-up interval.

The Influence of Fixation Rigidity on Intervertebral Joints - An Experimental Comparison between a Rigid and a Flexible System

  • Kim, Won-Joong;Lee, Sang-Ho;Shin, Song-Woo;Rivard, Charles H.;Coillard, Christine;Rhalmi, Souad
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권5호
    • /
    • pp.364-369
    • /
    • 2005
  • Objective: Spinal instrumentation without fusion often fails due to biological failure of intervertebral joints (spontaneous fusion, degeneration, etc). The purpose of this study is to investigate the influence of fixation rigidity on viability of intervertebral joints. Methods: Twenty pigs in growing period were subjected to posterior segmental fixation. Twelve were fixed with a rigid fixation system(RF) while eight were fixed with a flexible unconstrained implant(FF). At the time of the surgery, a scoliosis was created to monitor fixation adequacy. The pigs were subjected to periodic radiological examinations and 12pigs (six in RF, six in FF) were euthanized at 12-18months postoperatively for analysis. Results: The initial scoliotic curve was reduced from $31{\pm}5^{\circ}$ to $27{\pm}8^{\circ}$ in RF group (p=0.37) and from $19{\pm}4^{\circ}$ to $17{\pm}5^{\circ}$ in FF group (p=0.21). Although severe disc degeneration and spontaneous fusion of facet joints were observed in RF group, disc heights of FF group were well maintained without major signs of degeneration. Conclusion: The viability of the intervertebral joints depends on motion spinal fixation. Systems allowing intervertebral micromotion may preserve the viability of intervertebral discs and the facet joint articular cartilages while maintaining a reasonably stable fixation.

Functional Outcomes of Subaxial Spine Injuries Managed With 2-Level Anterior Cervical Corpectomy and Fusion: A Prospective Study

  • Jain, Vaibhav;Madan, Ankit;Thakur, Manoj;Thakur, Amit
    • Neurospine
    • /
    • 제15권4호
    • /
    • pp.368-375
    • /
    • 2018
  • Objective: To evaluate the results of operative management of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion with a cervical locking plate and autologous bone-filled titanium mesh cage. Methods: This study included 23 patients with a subaxial spine injury who matched the inclusion criteria, underwent 2-level anterior cervical corpectomy and fusion at our institution between 2013 and 2016, and were followed up for neurological recovery, axial pain, fusion, pseudarthrosis, and implant failure. Results: According to Allen and Ferguson classification, there were 9 cases of distractive extension; 4 of compressive extension; 3 each of compressive flexion, vertical compression, and distractive flexion; and 1 of lateral flexion. Sixteen patients had a score of 6 on the Subaxial Injury Classification system, and the rest had a score of more than 6. The mean follow-up period was 19 months (range, 12-48 months). Neurological recovery was observed in most of the patients (78.21%). All patients experienced relief of axial pain. None of the patients received a blood transfusion. Twenty-one patients (91.3%) showed solid fusion and 2 (8.69%) showed possible pseudarthrosis, with no complications related to the cage or plate. Conclusion: Two-level anterior cervical corpectomy and fusion, along with stabilization with a cervical locking plate and autologous bone graft-filled titanium mesh cage, can be considered a feasible and safe method for treating specific subaxial spine injuries, with the benefits of high primary stability, anatomical reduction, and direct decompression of the spinal cord.

Radicular Pain due to Subsidence of the Nitinol Shape Memory Loop for Stabilization after Lumbar Decompressive Laminectomy

  • Son, Byung-Chul;Kim, Deog-Ryeong
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권1호
    • /
    • pp.61-64
    • /
    • 2015
  • A number of dynamic stabilization systems have been used to overcome the problems associated with spinal fusion with rigid fixation recently and the demand for an ideal dynamic stabilization system is greater for younger patients with multisegment disc degeneration. Nitinol, a shape memory alloy of nickel and titanium, is flexible at low temperatures and regains its original shape when heated, and the Nitinol shape memory loop (SML) implant has been used as a posterior tension band mostly in decompressive laminectomy cases because the Nitinol implant has various characteristics such as high elasticity and a tensile force, flexibility, and biological compatibility. The reported short-term outcomes of the application of SMLs as posterior column supporters in cervical and lumbar decompressive laminectomies seem to be positive, and complications are minimal except for the rare occurrence of pullout and fracture of the SML. However, there was no report of neurological complications related to neural compression in spite of the use of the loop of SML in the epidural space. The authors report a case of delayed development of radiating pain caused by subsidence of the SML resulting epidural compression.

최근 척수손상 백서에서 인체지방조직유래 중간엽 줄기세포 이식 및 성장호르몬의 투여가 신경회복에 미치는 영향 (The Effect of Human Adipose Tissue Derived Mesenchymal Stem Cells and Growth Hormone on the Recovery of Neurological Deficits due to Experimental Spinal Cord Injury in Rat)

  • 이근철;문인선;허정;권용석;김석권;손희동
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.13-19
    • /
    • 2008
  • Purpose: Human adipose tissue-derived mesenchymal stem cells(hATSCs) can be differentiated into multiple mesenchymal lineages, including bone, cartilage, and muscle. And growth hormone play important roles in the normal growth and development of the CNS. In this study, we explored whether the transplanted hATSCs and growth hormones could improve functional recoveries from rats with contusive spinal cord injury. Methods: We divided 30 female rats, which were subjected to a weight driven implant spinal cord injury, into 3 groups with 10 rats each; Group A as a control group, group B with hATSCs transplantation on injured region, and group C with hATSCs transplantation and GH administration for 7 days. Then, we researched their neurologic functional recoveries before and 2, 4, and 8 weeks after transplantation using Basso-Beattie-Bresnahan (BBB) locomotor rating scale. And we checked Y-chromosome positive cells by FISH(Fluorescent in situ hybridization) to identify the survival of transplanted mesenchymal stem cells. Results: After 4 weeks of transplantation, the group B and group C showed significant improvement of neurologic function on BBB locomotor rating scale in comparison with the group A(Group A: $13.1{\pm}0.58$, Group B: $14.6{\pm}0.69$, Group C: $14.9{\pm}0.56$). Moreover, the group C displayed meaningful recovery of neurologic function after 8 weeks in comparison with group B (Group B: $15.7{\pm}0.63$, Group C: $16.5{\pm}1.14$). The group A, the control one, improved for 5 weeks after injury, and had no more recovery. On the other hand, Group B and C showed the improvement of neurologic function continuously for 9 weeks after injury. Conclusion: In this study, we found out that hATSCs transplantation have an effect on neurologic functional recovery of spinal cord injured rat and GH injection seems to bring the synergistic results on this good tendency.