• Title/Summary/Keyword: Spinal Cord Injury Patients

Search Result 199, Processing Time 0.028 seconds

Comparison of clinical efficacy in epidural steroid injections through transforaminal or parasagittal approaches

  • Hong, Ji Hee;Park, Eun Kyul;Park, Ki Bum;Park, Ji Hoon;Jung, Sung Won
    • The Korean Journal of Pain
    • /
    • v.30 no.3
    • /
    • pp.220-228
    • /
    • 2017
  • Background: The transforaminal (TF) epidural steroid injection (ESI) is suggested as more effective than the interlaminar (IL) route due to higher delivery of medication at the anterior epidural space. However, serious complications such as spinal cord injury and permanent neural injury have been reported. The purpose of this study is to evaluate and compare the clinical effectiveness, technical ease, and safety of the TF and parasagittal IL (PIL) ESI. Methods: A total of 72 patients were randomized to either the PIL group (n = 41) or the TF group (n = 31) under fluoroscopic guidance. Patients were evaluated for effective pain relief by the numerical rating scale (NRS) and Oswestry Disability Index (ODI) (%) before and 2 weeks after the ESI. The presence of concordant paresthesia, anterior epidural spread, total procedure time, and exposed radiation dose were also evaluated. Results: Both the PIL and TF approach produced similar clinically significant improvements in pain and level of disability. Among the 72 patients, 27 PIL (66%) and 20 TF (64%) patients showed concordant paresthesia while 14 (34%) and 11 (36%) patients in the same respective order showed disconcordant or no paresthesia. Radiation dose and total procedure time required were compared; the PIL group showed a significantly lower radiation dose ($30.2{\pm}12$ vs. $80.8{\pm}26.8$ [$Cgy/cm^2$]) and shorter procedure time ($96.2{\pm}31$ vs. $141.6{\pm}30$ seconds). Conclusions: ESI under fluoroscopic guidance with PIL or TF approach were effective in reducing the NRS and ODI. PIL ESI was a technically easier and simple method compared to TF ESI.

Anterior Decompression and Internal Fixation with Anterior Instrument and Surgical Titanium Mesh in Thoracolumbar Unstable Spine Injuries (Long-term Follow-up Results) (흉·요추 불안정성 척추 손상 환자에서 전방 감압술과 전방기기 및 Surgical Titanium Mesh를 이용한 내고정술 (장기적 추적 검사 결과))

  • Park, Hwan Min;Lee, Seung Myung;Cho, Ha Young;Shin, Ho;Jeong, Seong Heon;Song, Jin Kyu;Jang, Seok Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.58-65
    • /
    • 2000
  • Objective : Thoracolumbar junction is second most common level of injury next to cervical spine. The object of this study is to study the usefulness of surgical titanium mesh instead of bone graft, as well as to evaluate the correction of spinal deformity and safety of early ambulation in patients with injury at thoracolumbar junction. Patients and Methods : This review included 51 patients who were operated from July 1994 to December 1997. The injured spine is considered to be unstable, if it shows involvement of two or more columns, translatory displacement more than 3.5mm, decrease more than 35% in height of vertebral body and progression of malalignment in serial X-ray. The decision to operate was determined by (1) compression of spinal cord or cauda eguina, (2) unstable fracture, (3) malalignment and (4) fracture dislocation. The procedure consisted of anterior decompression through corpectomy and internal fixation with anterior instrument and surgical titanium mesh which was impacted with gathered bone chip from corpectomy. Results : Fifty-one patients were followed up for at least 12 months. The main causes of injury were fall and vehicle accident. The twelfth thoracic and the first and the second lumbar vertebrae were frequently involved. Complete neural decompression was possible under direct vision in all cases. Kyphotic angulation occurred in a patient. Radiologic evaluation showed correction of deformity and no distortion or loosening of surgical titanium mesh with satisfactory fixation postoperatively. Conclusions : We could obtain neurological improvement, relief of pain, immediate stabilization and early return to normal activities postoperatively. Based on these results, authors recommend anterior decompression and internal fixation with surgical titanium mesh in thoracolumbar unstable spine injuries.

  • PDF

Targeting a Safe Entry Point for C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability

  • Chun, Hyoung-Joon;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.351-354
    • /
    • 2011
  • Objective : This investigation was conducted to evaluate a new, safe entry point for the C2 pedicle screw, determined using the anatomical landmarks of the C2 lateral mass, the lamina, and the isthmus of the pars interarticularis. Methods : Fifteen patients underwent bilateral C1 lateral mass-C2 pedicle screw fixation, combined with posterior wiring. The C2 pedicle screw was inserted at the entry point determined using the following method : 4 mm lateral to and 4 mm inferior to the transitional point (from the superior end line of the lamina to the isthmus of the pars interarticularis). After a small hole was made with a high-speed drill, the taper was inserted with a 30 degree convergence in the cephalad direction. Other surgical procedures were performed according to Harm's description. Preoperatively, careful evaluation was performed with a cervical X-ray for C1-C2 alignment, magnetic resonance imaging for spinal cord and ligamentous structures, and a contrast-enhanced 3-dimensional computed tomogram (3-D CT) for bony anatomy and the course of the vertebral artery. A 3-D CT was checked postoperatively to evaluate screw placement Results : Bone fusion was achieved in all 15 patients (100%) without screw violation into the spinal canal, vertebral artery injury, or hardware failure. Occipital neuralgia developed in one patient, but this subsided after a C2 ganglion block. Conclusion : C2 transpedicular screw fixation can be easily and safely performed using the entry point of the present study. However, careful preoperative radiographic evaluation, regardless of methods, is mandatory.

A Gunshot Wounds to the Cervical Spine and the Cervical Spinal Cord: A Case Report (총상으로 인한 경추부 및 척수손상: 증례 보고)

  • Paeng, Sung Hwa
    • Journal of Trauma and Injury
    • /
    • v.25 no.2
    • /
    • pp.57-62
    • /
    • 2012
  • Gunshot wounds are rare in Korea, but they have tended to increase recently. We experienced an interesting case of penetrating gunshot injuries to the cervical spine with migration the fragments of the bullet within the dural sac of the cervical spine, so discuss the pathomechanics, treatment and complications of gunshot wounds to the spine and present a review of the literature. A 38-year-old man who had tried to commit suicide with a gun was admitted to our hospital with a penetrating injury to the anterior neck. the patient had quadriplegia. A Computed tomography (CT) scan and 3-dimensional CT of the spine showed destruction of the left lateral mass and lamina of the 5th cervical vertebra; the bullet and fragments were found at the level of the 5th cervical vertebra. The posterior approach was done. A total laminectomy and removal of the lateral mass of the 5th cervical vertebrae were performed, and bone fragments and pellets were removed from the spinal canal, but an intradurally retained pellets were not totally removed. A dural laceration was noted intraoperatively, and CSF leakage was observed, so dura repair was done watertightly with prolene 6-0. The dura repair site was covered with fibrin glue and Tachocomb$^{(R)}$. Immediately, a lumbar drain was done. Radiographs included a postoperative CT scan and X-rays. The postoperative neurological status of the patient was improved compared with the preoperative neurological status. however, the patients developed symptoms of menigitis. He received lumbar drainage(200~250 cc/day) and ventilator care. After two weeks, panperitonitis due to duodenal ulcer perforation was identified. Finally, the patient died because of sepsis.

Can the Zero-Profile Implant Be Used for Anterior Cervical Discectomy and Fusion in Traumatic Subaxial Disc Injury? A Preliminary, Retrospective Study

  • Kim, Tae Hun;Kim, Dae Hyun;Kim, Ki Hong;Kwak, Young Seok;Kwak, Sang Gyu;Choi, Man Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.574-581
    • /
    • 2018
  • Objective : The zero-profile implant (Zero-P) is accepted for use in anterior cervical fusion for the treatment of degenerative cervical disease. However, evidence pertaining to its efficiency and safety in traumatic cervical injury is largely insufficient. This study aimed to compare the overall outcomes of patients who underwent Zero-P for traumatic cervical disc injury. Methods : Data from a total of 53 consecutive patients who underwent surgery for traumatic or degenerative cervical disc disease using the Zero-P were reviewed. Seventeen patients (group A) had traumatic cervical disc injury and the remaining 36 (group B) had degenerative cervical disc herniation. The fusion and subsidence rates and Cobb angle were measured retrospectively from plain radiographs. The patients' clinical outcomes were evaluated using the Japanese Orthopedic Association (JOA) score and Odom's criteria. Results : The C2-7 Cobb and operative segmental angles increased by $3.45{\pm}7.61$ and $2.94{\pm}4.59$ in group A; and $2.46{\pm}7.31$ and $2.88{\pm}5.49$ in group B over 12 postoperative months, respectively. The subsidence and fusion rate was 35.0% and 95.0% in group A; and 36.6% and 95.1% in group B, respectively. None of the parameters differed significantly between groups. The clinical outcomes were similar in both groups in terms of increasing the JOA score and producing a grade higher than "good" using Odom's criteria. Conclusion : The application of Zero-P in patients with traumatic cervical disc injury was found to be acceptable when compared with the clinical and radiological outcomes of degenerative cervical spondylosis.

A Study on the Effect of Time Lapse After Position Change and Abdominal Band on Pulmonary Function in the Cervical Cord Injuries (척수손상 환자의 자세 변화 후 시간경과와 복대사용이 폐기능에 미치는 영향)

  • Lee, Jae-Ho;Park, Chang-Il;Chon, Joong-Sun
    • Physical Therapy Korea
    • /
    • v.4 no.3
    • /
    • pp.17-33
    • /
    • 1997
  • The objective of this study was to identify pulmonary functional variations in relation to postural changes, lapse after changing position, and the use of abdominal band in the cervical cord injured. The subjects of this study were 19 quadriplegic patients who had been admitted to the department of the Rehabilitation Hospital, College of Medicine, Yousei University, from April, 1997 through May 3, 1997. A spiroanalyzer was used to measure pulmonary function in supine, standing, time after changing position, and recording to the position, application method, and tightness of the abdominal band. The data were analyzed by the repeated measure one-way ANOVA, and Wilcoxon signed rank test. The findings were as follows: 1. All phase of the patients' pulmonary function improved significantly in supine posture in contrast to standing (vital capacity by $0.46{\ell}$ and expiratory reserve volume by $0.09{\ell}$). 2. The longer the time lapsed from supine posture to standing, the patient's expiratory reserve volume, maximum ventilation volume, vital capacity, and forced expiratory volume increased. 3. When the patient lay in supine position, the maximum ventilation volume, vital capacity, and the forced vital capacity increased then the center line of the abdominal band was placed along iliac crest; on the other hand, when the patient was standing, placing the bottom line of the abdominal band along iliac crest increased the maximum ventilation volume, vital capacity, and forced expiratory volume. 4. In placing the abdominal band in the patients, leaving space between the top and bottom lines of the band helped increased in maximum ventilation volume, vital capacity, and forced vital capacity for patient in supine as well as in standing. 5. When placing the abdominal band to patients in supine posture, reducing the length of the band by 2.5% along the patient's waist line increased the patients' vital capacity, while reducing the length by 10% to patients in standing increased the maximum ventilation volume. The abdominal band should be placed in such a way that the bottom part of the band should be more tightly fastened while leaving enough room for a hand to be placed in between the body and the band for the top part of the hand. It should also be noted that in a supine position, the bottom line of the band should be placed along the iliac crest, while in standing, the center line should be placed along the iliac crest. The length of the band should also be reduced by 2.5% of the waist line in supine position, and in standing, the length should be reduced by 10%. It should also be noted that the pulmonary function of the patients should be measured at least 10 minutes after one position change.

  • PDF

Upper Extremity Biomechanics of Manual Wheelchair Propulsion at Different Speeds (수동 휠체어 추진 속도에 따른 상지 관절 생체역학적 영향 분석)

  • Hwang, Seonhong
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.241-250
    • /
    • 2022
  • It is known that chronic pain and injury of upper limb joint tissue in manual wheelchair users is usually caused by muscle imbalance, and the propulsion speed is reported to increase this muscle imbalance. In this study, kinematic variables, electromyography, and ultrasonographic images of the upper limb were measured and analyzed at two different propulsion speeds to provide a quantitative basis for the risk of upper extremity joint injury. Eleven patients with spinal cord injury for the experimental group (GE) and 27 healthy adults for the control group (GC) participated in this study. Joint angles and electromyography were measured while subjects performed self-selected comfortable and fast-speed wheelchair propulsion. Ultrasound images were recorded before and after each propulsion task to measure the acromiohumeral distance (AHD). The range of motion of the shoulder (14.35 deg in GE; 20.24 deg in GC) and elbow (5.25 deg in GE; 2.57 deg in GC) joints were significantly decreased (p<0.001). Muscle activation levels of the anterior deltoid, posterior deltoid, biceps brachii, and triceps brachii increased at fast propulsion. Specifically, triceps brachii showed a significant increase in muscle activation at fast propulsion. AHD decreased at fast propulsion. Moreover, the AHD of GE was already narrowed by about 60% compared to the GC from the pre-tests. Increased load on wheelchair propulsion, such as fast propulsion, is considered to cause upper limb joint impingement and soft tissue injury due to overuse of the extensor muscles in a narrow joint space. It is expected that the results of this study can be a quantitative and objective basis for training and rehabilitation for manual wheelchair users to prevent joint pain and damage.

Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.237-247
    • /
    • 2020
  • Objective : Fixation of the C1-2 segment is challenging because of the complex anatomy in the region and the need for a high degree of accuracy to avoid complications. Preoperative 3D-computed tomography (CT) scans can help reduce the risk of complications in the vertebral artery, spinal cord, and nerve roots. However, the patient may be susceptible to injury if the patient's anatomy does not match the preoperative CT scans. The intraoperative 3D image-based navigation systems have reduced complications in instrument-assisted techniques due to greater accuracy. This study aimed to compare the radiologic outcomes of C1-2 fusion surgery between intraoperative CT image-guided operation and fluoroscopy-guided operation. Methods : We retrospectively reviewed the radiologic images of 34 patients who underwent C1-2 fusion spine surgery from January 2009 to November 2018 at our hospital. We assessed 17 cases each of degenerative cervical disease and trauma in a study population of 18 males and 16 females. The mean age was 54.8 years. A total of 139 screws were used and the surgical procedures included 68 screws in the C1 lateral mass, 58 screws in C2 pedicle, nine screws in C2 lamina and C2 pars screws, four lateral mass screws in sub-axial level. Of the 34 patients, 19 patients underwent screw insertion using intraoperative mobile CT. Other patients underwent atlantoaxial fusion with a standard fluoroscopy-guided device. Results : A total of 139 screws were correctly positioned. We analyzed the positions of 135 screws except for the four screws that performed the lateral mass screws in C3 vertebra. Minor screw penetration was observed in seven cases (5.2%), and major pedicle screw penetration was observed in three cases (2.2%). In one case, the malposition of a C2 pedicle screw was confirmed, which was subsequently corrected. There were no complications regarding vertebral artery injury or onset of new neurologic deficits. The screw malposition rate was lower (5.3%) in patients who underwent intraoperative CT-based navigation than that for fluoroscopy-guided cases (10.2%). And we confirmed that the operation time can be significantly reduced by surgery using intraoperative O-arm device. Conclusion : Spinal navigation using intraoperative cone-beam CT scans is reliable for posterior fixation in unstable C1-2 pathologies and can be reduced the operative time.

Mid-Term Results of Using the Seal Thoracic Stent Graft in Cases of Aortopathy: A Single-Institution Experience

  • Cho, Jun Woo;Jang, Jae Seok;Lee, Chul Ho;Hwang, Sun Hyun
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.335-341
    • /
    • 2019
  • Background: The endovascular approach to aortic disease treatment has been increasingly utilized in the past 2 decades. This study aimed to determine the long-term results of using the Seal thoracic stent graft. Methods: We retrospectively reviewed the outcomes of patients who underwent thoracic endovascular aortic repair or a hybrid procedure using the Seal thoracic stent graft (S&G Biotech, Seongnam, Korea) from January 2008 to July 2018 at a single institution. We investigated in-hospital mortality and the incidence of postoperative complications. We also investigated the mid-term survival rate and incidence of aorta-related complications. Results: Among 72 patients with stent grafts, 15 patients underwent the hybrid procedure and 21 underwent emergency surgery. The mean follow-up period was $37.86{\pm}30.73$ months (range, 0-124 months). Five patients (6.9%) died within 30 days. Two patients developed cerebrovascular accidents. Spinal cord injury occurred in 2 patients. Postoperative renal failure, postoperative extracorporeal membrane oxygenation support, and pneumonia were reported in 3, 1, and 6 patients, respectively. Stent-related aortic complications were observed in 5 patients (6.8%). The 1- and 5-year survival and freedom from stent-induced aortic event rates were 81.5% and 58.7%, and 97.0% and 89.1%, respectively. Conclusion: The use of the Seal thoracic stent graft yielded good mid-term results. Further studies are needed to examine the long-term outcomes of this device.

Latissimus dorsi detrusor myoplasty for bladder acontractility: a systematic review

  • Forte, Antonio Jorge;Boczar, Daniel;Huayllani, Maria Tereza;Moran, Steven;Okanlami, Oluwaferanmi O.;Ninkovic, Milomir;Broer, Peter N.
    • Archives of Plastic Surgery
    • /
    • v.48 no.5
    • /
    • pp.528-533
    • /
    • 2021
  • Bladder acontractility affects several thousand patients in the United States, but the available therapies are limited. Latissimus dorsi detrusor myoplasty (LDDM) is a therapeutic option that allows patients with bladder acontractility to void voluntarily. Our goal was to conduct a systematic review of the literature to determine whether LDDM is a better option than clean intermittent catheterization (CIC) (standard treatment) in patients with bladder acontractility. On January 17, 2020, we conducted a systematic review of the PubMed/MEDLINE, Cochrane Clinical Answers, Cochrane Central Register of Controlled Trials, Embase, and ClinicalTrials.gov databases, without time frame limitations, to identify articles on the use of LDDM for bladder acontractility. Of 75 potential articles, 4 fulfilled the eligibility criteria. The use of LDDM to treat patients with bladder acontractility was reported in four case series by the same group in Europe. Fifty-eight patients were included, and no comparison groups were included. The most common cause of bladder acontractility was spinal cord injury (n=36). The mean (±standard deviation) operative time was 536 (±22) minutes, postoperative length of hospital stay ranged from 10 to 13 days, and follow-up ranged from 9 to 68 months. Most patients had complete response, were able to void voluntarily, and had post-void residual volume less than 100 mL. Although promising outcomes have been obtained, evidence is still weak regarding whether LDDM is better than CIC to avoid impairment of the urinary tract among patients with bladder acontractility. Further prospective studies with control groups are necessary.