• Title/Summary/Keyword: Spherical equivalent refractive power

Search Result 28, Processing Time 0.026 seconds

A Study on the Refractive Power of School Children Who are Classified in Low Income Family (저소득층 분류에 따른 학동기 아동의 굴절력에 관한 연구)

  • Lee, Wan-Seok;Ye, Ki-Hun;Shin, Bum-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.373-383
    • /
    • 2013
  • Purpose: In this study, we analyzed refractive power of school children in low income family. Methods: We have done a comparative analysis with 112 subjects of low-income of 17 elementary schools in the Yeongcheon area and low-income children less than -6 D of refractive errors from the Korean National Health and Nutrition Examination Survey Report 2010. Results: Spherical equivalent (SE) with low-income group of nation was -1.99 D for right eye and -1.81 D for left eye, while high income group of nation showed -1.26 D and -1.21 D for right eye and left eye respectively. The SE with low income group in Yeongcheon area was -1.85 D for right eye and -1.81 D for left eye. The SE with orphan was -2.75 D and -2.42 D. Single parent family was -2.10 D and -1.96 D, and two parent family was -1.75 D and -1.73. Conclusions: The lack of attention to children eye care may be one of cause for myopia, so the role of the parents and teacher is very important. However, limited role of parents to children due to low income, it is necessary to provide an institutional strategy and social interest to prevent children vision' in low income family.

Correlation between Corneal Ablation Amount and Intraocular Pressure after Corneal Refractive Surgery (각막굴절교정수술 후 각막절삭량과 안압변화의 상관관계)

  • Jung, Mi-A;Lee, Eun-Hee
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.543-551
    • /
    • 2018
  • Purpose : The purposes of this study were to evaluate the changes of intraocular pressure according to corneal ablation amount after corneal refractive surgery and the changes of intraocular pressure according to refractive errors before corneal refractive surgery. Methods : The mean age of adults who underwent LASIK corneal refractive surgery were $37.34{\pm}7.42years$, and 108 adults(48 males, 60 females) were participated in this study. Refractive errors, intraocular pressure, and corneal ablation amount were measured using an autorefractor, a noncontact tonometer, and an excimer laser. All test values were considered statistically significant when p<0.05. Results : The mean intraocular pressure before corneal refractive surgery was $15.08{\pm}2.60mmHg$ in males and $14.16{\pm}2.67mmHg$ in females. The decrease of intraocular pressure after corneal refractive surgery were 4.22mmHg in males and 3.61mmHg in females. Spherical equivalent power were $-3.89{\pm}2.17D$ in males and $-4.45{\pm}2.92D$ in females before corneal refractive surgery, and $-0.10{\pm}0.46D$ in males and $-0.04{\pm}0.46D$ in females after corneal refractive surgery. The corneal ablation amount after corneal refractive surgery were statistically significant, with $53.95{\mu}m$ in males and $61.26{\mu}m$ in females. There was significant correlation between corneal ablation amount and decrease of intaocluar pressure(r=0.2299, p<0.001). As the growth of corneal ablation amount in males, the decrease of intraocular pressure was significantly increased. As the growth of refractive error, the amount of decrease in intraocular pressure was also significant. The decrease of intraocualr pressure were $3.04{\pm}2.18mmHg$ in low refractive error, $4.10{\pm}2.16mmHg$ in middle refractive error, and $4.65{\pm}3.29mmHg$ in high refractive error. Conclusion : We found that intraocular pressure decreased after corneal refractive surgery by noncontact tonometer and the change of intraocular pressure which is an important index for glaucoma diagnosis, may affect the judgment of eye disease. We think that a preliminary questionnaire whether corneal refractive surgery is necessary for the measurement of intraocular pressure.

Predicting Powers of Spherical Rigid Gas-permeable Lenses Prescription (구면 RGP 렌즈의 처방 굴절력 예측)

  • Yu, Dong-Sik;Yoo, Jong-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.219-225
    • /
    • 2010
  • Purpose: Usefulness in predicting the power of spherical rigid gas-pearmeable (RGP) lenses prescription using dioptric power matrices and arithmetic calculations was evaluated in this study. Noncycloplegic refractive errors and over-refractions were performed on 110 eyes of 55 subjects (36 males and 19 females, aged $24.60{\pm}1.55$years) in twenties objectively with an auto-refractometer (with keratometer) and subjectively. Tear lenses were calculated from keratometric readings and base curves of RGP lenses, and the power of RGP lenses were computed by a dioptric power matrix and an arithmetic calculation from the manifest refraction and the tear lens, and were compared with those by over-refractions in terms of spherical (Sph), spherical quivalent (SE) and astigmatic power. Results: The mean difference (MD) and 95% limits of agreement (LOA=$MD{\pm}1.96SD$) were better for SE (0.26D, $0.26{\pm}0.70D$) than for Sph (0.61D, $0.61{\pm}0.86D$). The mean difference and agreement of the cylindrical power between matrix and arithmetic calculation (-0.13D, $-0.13{\pm}0.53D$) were better than between the others (-0.24D, $0.24{\pm}0.84D$ between matrix and over-refraction; -0.12D, $0.12{\pm}1.00D$ between arithmetic calculation and over-refraction). The fitness of spherical RGP lenses were 54.5% for matrix, 66.4% for arithmetic calculation and 91.8% for over-refraction. Arithmetic calculation was close to the over-refraction. Conclusions: In predicting indications and powers of spherical RGP lens fitting, although there are the differences of axis between total (spectacle) astigmatism and corneal astigmatism, Spherical equivalent using an arithmetic calculation provides a more useful application than using a dioptric power matrix.

Determination Factors Affecting the High Order Aberrations in Preoperative and Postoperative LASEK (라섹 수술 전과 후의 고위수차에 영향을 미치는 결정변수)

  • Kim, Tae-Heung;Lee, Hyun;Rhee, Kang-Oh;Lee, Tae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5621-5627
    • /
    • 2014
  • To specify the standard of LASEK surgery, this study examined the determination factors affecting the high order aberrations (HOAs) in preoperative and postoperative LASEK. 51 adult patients (102 eyes) were evaluated at the baseline and 2 months after LASEK surgery from Nov 2011 to Jul 2012. The postoperative HOAs ($0.538{\mu}m$) were higher than the preoperative ($0.341{\mu}m$). In linear regression analysis, the refractive components that affected the postoperative HOAs were $J_0$ of corneal astigmatism (CA, 0.400), $J_0$ of refractive astigmatism (RA, 0.389), corneal astigmatism (CA, 0.282), spherical equivalent (SE, 0.239), refractive astigmatism (RA, 0.213), and pupil size (PS, 0.194) with a high R. In multiple regression, $J_0$ of CA, PS and SE were significant factors with the postoperative HOAs. In conclusion, both HOAs and $J_0$ of CA should be considered when determining the suitable factors for LASEK surgery.

Study on the Correlation between Refractive error and Components of Eye's Optical system in Children and Teenagers in an Optometric Practice (안과 병원을 내원한 소아 청소년의 굴절이상과 안광학 성분간의 상관관계 연구)

  • Ha, Na-Ri;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.67-74
    • /
    • 2012
  • Purpose: The purpose of this study to evaluate visual acuity and refractive state and measure and analyze the components of eye's optical system in children and teenagers. Methods: With subjects of 124 (230 eyes) children and teenagers who had no eye diseases, correlation between the correlation between refractive errors and component's of eye's optical system was investigated. The spherical equivalent power of cycloplegic clinical refraction or manifest clinical refraction(SE), corneal power(CP), corneal radius(CR), axial length(AL), anterior chamber depth(ACD) and axial length to corneal radius (AL/CR) ratio were measured and analysed. Results: the SE was negatively correlated with the AL(r = -0.80, p = 0.00), the ACD(r = -0.35, p = 0.00) and the CR(r = -0.11, p=0.00) and positively correlated with the CP(r = +0.11, p=0.00). The AL was positively correlated with the AL/CR ratio (r = +0.84, p = 0.00), the ACD(r = +0.47, p=0.00) and the CR(r = +0.38, p = 0.00) and negatively correlated with the CP(r = -0.38, p=0.00). The CR was negatively correlated with CP(r = -1.00, p = 0.00), the AL/CR ratio(r = -0.19, p = 0.00) and the ACD(r = -0.06, p = 0.39). The CP was positively correlated with the AL/CR ratio(r = +0.19, p = 0.00) and the ACD(r = +0.06, p = 0.39). The ACD was positively correlated with the AL/CR ratio(r = 0.53, p = 0.00). Conclusions: the highest change of refractive errors was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive errors of the children and teenagers.

Analysis of the Eyeglasses Supply System for Ametropes in ROK Military (한국군 비정시자용 안경의 보급체계 분석)

  • Jin, Yong-Gab;Koo, Bon-Yeop;Lee, Woo-Chul;Yoon, Moon-Soo;Park, Jin-Tae;Lee, Hang-Seok;Lee, Kyo-Eun;Leem, Hyun-Sung;Jang, Jae-Young;Mah, Ki-Choong
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.579-588
    • /
    • 2018
  • Purpose : To analyze the eyeglasses supply system for ametropic soldiers in ROK military. Methods : We investigated and analyzed the supply system of eyeglasses for the ametropic soldiers provided by the Korean military. The refractive powers and corrected visual acuity were measured for 37 ametropic soldiers who wear insert glasses for ballistic protective and gas-masks supplied by the military based on their habitual prescriptions. Full correction of refractive error was prescribed for subjects having less than 1.0 of distance visual acuity, and comparison was held for inspecting the changes in corrected visual acuity. Suggestions were provided for solving the issues regarding current supplying system, and this study investigated the applicabilities for utilizing professional optometric manpower. Results : The new glasses supplied by army for ametropic soldiers were duplicated from the glasses they worn when entering the army. The spherical equivalent refractive powers of the conventional, ballistic protective and gas-mask insert glasses supplied for 37 ametropic soldiers were $-3.47{\pm}1.69D$, $-3.52{\pm}1.66D$ and $-3.55{\pm}1.63D$, respectively, and the spherical equivalent refractive power of full corrected glasses was $-3.79{\pm}1.66D$, which showed a significant difference(p<0.05). The distant corrected visual acuity measured at high and low contrast(logMAR) of conventional, ballistic protective and gas-mask insert glasses were $0.06{\pm}0.80$, $0.21{\pm}0.82$, $0.15{\pm}0.74$, $0.34{\pm}0.89$, $0.10{\pm}0.70$ and $0.22{\pm}0.27$, respectively, while the corrected visual acuity by full corrected glasses were increased to $0.02{\pm}1.05$, $0.10{\pm}0.07$, $0.09{\pm}0.92$, $0.26{\pm}0.10$, $0.04{\pm}1.00$ and $0.19{\pm}1.00$, respectively. There was a significant difference(p<0.05) except for the case of the low contrast corrected visual acuity of the conventional and gas-mask insert glasses. The procedure for ordering, dispensing, and supplying military glasses consists of 5 steps, and it was found that approximately two weeks or more are required to supply from the initial examination. Conclusion : The procedure of supplying the military glasses showed three issues: 1) a lack of refraction for prescription system, 2) relatively long length of time required for supplying the glasses, 3) an inaccurate power of supplied glasses. In order to solve those issues, in the short term, education is necessarily required for soldiers on the measurement of the refractive powers, and in the near future, further standard procedures for prescription of glasses as well as the securement of optometric manpower are expected.

Comparison of Stereopsis by Influence Factors in Induced Aniseikonia (유발 부등상시에서 영향인자에 따른 입체시의 비교)

  • Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.465-471
    • /
    • 2013
  • Purpose: This study was conducted to research effects of influence factors on stereopsis of induced aniseikonia in emmetropia. Methods: 20 college students (a mean age of $22.50{\pm}2.72$ years, 14 males, 6 females) were selected as subjects and all of them had no ocular disease or systemic disease, the refractive correction of spherical equivalent within ${\pm}0.50$ D, the corrected visual acuity of 1.0 or better and the aniseikonia values less than 1% by AWAYA. Subject's dominant eye was checked by Hole in card method and contact lenses of -7.00 ~ +7.00D were fitted to cause anisometropia in dominant eye or non-dominant eye, respectively. And then aniseikonia was induced with spectacles to correct refractive error by contact lenses. Stereopsis was measured by Random Dot Stereo Acuity Test with LEA symbols$^{(R)}$ (Vision Assessment Corporation$^{TM}$, USA). Results: Stereopsis was remarkably reduced by inducing aniseikonia, with induced aniseikonia in dominant eye, with higher diopter of wearing contact lenses to induce anisometropia, with spectacles lenses correction of minus power after fitting contact lenses with plus power and in case of men. Conclusions: It should be considered to correct anisometropia that aniseikonia could cause reduction of stereopsis.

A Study for the Refractive Error in Middle and High School Pupils on the Basis of Their Glasses Power (안경도수를 근거로 한 중·고등학생의 굴절이상에 관한 연구)

  • Sung, Duk-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.169-175
    • /
    • 2003
  • This research reviewed that 83 male subjects. 89 female subjects of middle and high school visited D Optical shop at the downtown of Daegu more than twice from January, 1999 to January, 2003 and obtained the following results by using the visual acuity prescription of them for which D Optical shop was keeping. 1. The classification of correction power for 190 myopia eyes was examined (87 male eyes, 103 female eyes) showed 89 eyes(46.82%) between $0.25D{\leq}3.00D$, 86 eyes(45.26%) between $3.25D{\leq}6.00D$, 15 eyes(7.89%) for over 6.25D. 2. The kind of 154 astigmatism subjects(79 male eyes, 75 female eyes) was direct astigmatism 83.77%, reverse astigmatism 11.69%, oblique astigmatism 4.55%. The cylindrical correction power for astigmatic eyes was 61 eyes(39.61%) between $0.25D{\leq}0.50D$, 60 eyes(38.96%) between 0.50D<1.00D, 121 eyes(78.57%) for less than 1.06D, 6 eyes(0.65%) for over 3.00D. 3. The variation of spherical power showed 161 eyes(46.80%) between $0.00D{\leq}0.50D$, 109 eyes(31.69%) between $0.51D{\leq}1.00D$, 17 eyes(4.94%) for over 2.01D variation. 4. The variation of astigmatic power showed 92 eyes(59.74%) between $0.00D{\leq}0.50D$, 39 eyes(25.32%) between $0.26D{\leq}0.50D$, 10eyes (6.49%) between $0.51D{\leq}0.75D$, 13 eyes(8.44 %) for over 0.76D astigmatic variation. 5. The variation of equivalent spherical power showed 137 eyes(39.83%) between $0.00D{\leq}0.50D$, 126 eyes(36.63%) between $0.51D{\leq}1.00D$, 40 eyes(11.63%) between $1.01D{\leq}1.50D$, 21 eyes(6.10%) between $1.51D{\leq}2.00D$, 20 eyes(5.81%) for over 2.01D variation.

  • PDF