• Title/Summary/Keyword: Spherical aberration

Search Result 110, Processing Time 0.034 seconds

Aspherical Lens Design and Development of Spherical Aberration Measuring System by use of Spherical Aberration (구면 수차를 이용한 비구면 렌즈의 설계와 수차 측정 장치 개발)

  • Park, Kyu-Yeol;Kim, Han-Seob
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.175-180
    • /
    • 2007
  • In this paper, an aberration free aspherical lens is designed and machined by new design method and the spherical aberration measuring system is developed. It confirmed the propriety of new design method by measuring optical characteristics of machined lens with the new measuring system. The system could measure a spherical aberration quantitatively by using CCD camera, laser, collimator and so on.

Design of Aspherical Lens Shape by Modification of Spherical Aberration (구연수차 보정을 이용한 비구면 렌즈의 형상설계)

  • 김한섭;박규열;전종업
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.52-55
    • /
    • 2002
  • In this research, the modification method of spherical aberration, and aspherical lens shape design method were investigated. Spherical aberration affects lens's performance directly. Many studies have attempted to remove spherical aberration with a lot of methods in order to reduce the bad effect of spherical aberration. The approach to lens shape design was base on the ray tracing method. From the result, it was confirmed that ray reverse-tracing method was convenient to remove spherical aberration, and could be used very effectively and usefully for aberration-free aspherical lens design.

  • PDF

Analysis of anterior and posterior corneal spherical aberration with age in the korean (한국 성인의 연령에 따른 각막 전후면 구면수차에 관한 분석)

  • Song, Yun-Young;Jung, Mi-A;Kang, In-San;Choi, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.315-320
    • /
    • 2013
  • We have investigated the variation of spherical aberration of the anterior and posterior surface in a Korean sample population with various age between 20 to 71 years old. We used Pentacam (Oculus Inc., Germany) to measure the corneal radius, asphericity, and spherical aberration of 290 patients with normal cornea. There were negative correlation between corneal anterior radius and spherical aberration(r = -0.22, p<0.0001), and, there were negative correlation between corneal posterior radius and spherical aberration(r=-0.27, p < 0.0001). There were positive correlation between anterior asphericity and spherical aberration(r = 0.24, p < 0.0001), however there were negative correlation between posterior asphericity and spherical aberration(r = -0.17, p=0.00288).The average of anterior spherical aberration and posterior spherical aberration was $0.482{\pm}0.099{\mu}m$ and $-0.098{\pm}0.029{\mu}m$. The average of spherical aberration was $0.385{\pm}0.097{\mu}m$. There were significant positive correlations between anterior spherical aberration and age(r = 0.227, p<0.0001), and there were positive correlations between posterior aberration and age(r = 0.349, p<0.0001). It is considered that this data can be used as basic information for furture studies for improving the quality of vision of modern human and, through the analysis of the spherical aberration of cornea was to provide a better understanding of the optical part of the Korean's eye.

Measurement of Spherical Aberration and Light Concentrating Efficiency of Lens by Using Thermocouple (열전대를 이용한 광학렌즈의 구면수차와 집광성능 측정)

  • Kim, Han-Seob;Park, Kyu-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.172-177
    • /
    • 2007
  • In this paper, spherical aberration and light concentrating efficiency of lens was measured. The measuring system is applying spherical aberration occurrence principal and could measure a temperature at focal plane by using the thermocouple. The sun which is located in infinite distance and could makes parallel ray is used as a illuminant or heat source in experiments. It is confirmed that light concentrating efficiency of optical lens is in inverse proportion to spherical aberration and.

Simulation of Lens Aberration Correction for Polygon Mirror Scanning (PMS) (Polygon Mirror Scanning (OMS)을 위한 렌즈의 구면 수차 보정 시뮬레이션)

  • 신승연
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1999.08a
    • /
    • pp.128-129
    • /
    • 1999
  • Polygon Mirror Scanning(PMS) is composed of LED array, magnifying lens, polygon mirror and motor. It is important to correct the lens aberrations to gain the image we want to show. In this paper, we have simulated the lens aberration correction to reduce the spherical aberration . We have obtained a aspherical lens which is corrected the spherical aberration.

  • PDF

Development of Spherical Aberration Simulation Program for Education using Visual Basic.net (Visual Basic.net을 이용한 구면수차 시뮬레이션 교육 프로그램 개발)

  • Seo, Jeung-Ik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.83-86
    • /
    • 2007
  • In this study, a program has been developed to enable a simulation of spherical aberration - originated from a spherical surface and an aspheric surface - via ray tracing and calculation of the degree of spherical aberration. This process has been verified for the variation of spherical aberration generated from ray tracing for aspheric surfaces such as an oval, a parabola, and a hyperbola. By comparing it with the spherical surface, the principle and necessity of the aspheric surface lens design have been understood. In addition, it allows confirming the accuracy of the simulation by developing a ray tracing program in relation to the mirror plane of a parabola.

  • PDF

Changes in Spherical Aberration and Coma Aberration after Wearing Aspheric Soft Contact Lens in Young Myopes (젊은 성인 근시안에서 비구면 소프트 콘택트렌즈 착용 후 구면수차와 코마수차의 변화)

  • Lim, Dong-Kyu;Kwon, Hyeok;Lee, Koon-Ja
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.469-482
    • /
    • 2018
  • Purpose : We investigated the change of spherical and comma aberrations after wearing aspheric soft contact lens (ASCL) in young myopes. Methods : Fifty young myopes ($23.15{\pm}1.70years$, spherical equivalent: $-2.90{\pm}1.75D$) were recruited and refractive errors were corrected using ASCL (Biotrue, Bausch+Lomb, USA). High order aberrations were measured in the 4 mm pupil size using the wavefront analyze and pupil sizes were measured with a pupillometer at the modes of scotopic condition (light off) at 3.5 m in the 100 lx illuminance condition. Results : Spherical aberrations and coma aberration of the 20s myopes were $0.026{\pm}0.031{\mu}m$ and $0.078{\pm}0.039{\mu}m$ respectively, and $0.019{\pm}0.026{\mu}m$ and $0.082{\pm}0.038{\mu}m$ after ASCL wear that spherical aberration was decreased and coma aberration was increased. However, spherical aberration was decreased in the 68% of the subject have positive spherical aberration, and increased in the 11% of the subject have negative spherical aberration. Coma aberration was increased in the 53% of the subject, did not change in the 19% of the subjects, and decreased in the 28% of the subject. Spherical aberration was not different with the refractive errors in low and moderate myopies, however, coma aberrations was higher in the higher myopes. Conclusion : In a scotopic condition without accommodation stimuli, spherical aberration is decreased after wearing ASCL, however in the subject have negative spherical aberration spherical aberration could be increased, and which is thought to be the influence of contact lens design and pupil size.

A Study on Actuator Design for SA Compensation (구면 수차 보상을 위한 엑츄에이터 설계에 대한 연구)

  • 이성훈;박관우;김진아;최인호;김진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.346-350
    • /
    • 2004
  • In Blu-ray(BD) optical system, as a short laser wavelength of laser diode and thin cover layer thickness of' disc, the proper adjustment of spherical aberration should be performed. Considering thin cover layer' thickness and tolerance variation of disc in BD optical system, spherical aberration in BD format is mort: serious than CDㆍDVD format Especially, in dual-layer disc, to compensate the aberration at each layer, optical component should be moved finely in the way of optical path. In this study, 1 -axis moving actuator was introduced as the method of compensating the spherical aberration, and the mechanism of the system was described. Finally, its effect on optical system will be mentioned.

  • PDF

Design of Spherical Aberration Free Aspherical Lens by Use of Ray Reverse Tracing Method (광선 역추적 방식을 이용한 구면수차 제거 비구면 렌즈의 설계)

  • 김한섭;박규열;이원규;전종업
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.191-198
    • /
    • 2003
  • In this study, aberration free aspherical lens design method named ray reverse tracing method is introduced. Differently from the traditional design method, the ray reverse tracing method traces the shape and location of a real object by use of its virtual image. From the result, especially spherical aberration free aspherical lens could be designed by use of the ray reverse tracing method. Furthermore, it could reduce the degree of dependence of optical characteristics on designer's ability, because deformation terms and optimization can be eliminated, which has been performed in conventional lens design process.

Design and Aberration Analysis of Four-Spherical Mirror System Corrected for 4 Aberrations (4개의 수차가 보정된 유한 물체점을 갖는 4-구면 반사경계의 설계 및 수차해석)

  • 김종태;공홍진;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.127-132
    • /
    • 1991
  • We have obtained the analytic solutions of the four spherical mirror system free from the Seidel third order aberratios which are spherical aberration, coma, astigmatism, and distortion, Vignetting. Petzval field curvature, and optical properties according to the design parameters are numerically investigated and optimized. The numerical aperture of this system is 0.2 and the half field angle is $1.5^{\circ}$.

  • PDF