• Title/Summary/Keyword: Spherical Aberration

Search Result 110, Processing Time 0.021 seconds

Optimization of optical design for Eye Glass Display

  • Moon, H.C.;Kim, T.H.;Park, K.B.;Park, Y.S.;Seok, J.M.;Kim, H.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1603-1606
    • /
    • 2005
  • Eye Glass Display (EGD) with microdisplay to realize the virtual display can make the large screen, so virtual image has been developed by using microdisplay panel. This paper shows study of low cost lens design and simulation for microdisplay system with 0.6" Liquid Crystal on Silicon (LCoS) panel. Lens design optimized consider to spherical aberration, astigmatism, distortion, and chromatic aberration. Code V is used and it designed an aspheric lens about exit pupil 6mm, eye relief 20mm and 35 degree of field of view (FOV). With the application this aspheric lens to LCOS type's microdisplay, virtual image showed 50 inch at 2m. One side of the aspheric lens was constituted from diffractive optical element (DOE) for the improvement in a performance. It had less than ${\pm}2%$ of distortion value and modulation transfer function in axial had 20% of resolution with 30 lp/mm spatial frequency. The optical system is suitable for display of 0.6"-diagonal with SVGA.

  • PDF

Analysis on Phase and Amplitude Apodization in SIL Based Near-Field Recording Optics (SIL 응용 광 기록계에서 발생하는 위상 및 진폭 Apodization 해석)

  • Kim Wan-Chin;Choe Hyeon;Song TaeSun;Park No-Cheol;Park Young-Pil
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.14-15
    • /
    • 2005
  • In near-field recording (NFR) optics using solid immersion lens (SIL), near-field air gap induces unwanted spherical aberration, defocus and astigmatism. This phenomenon can be explained with the apodization of phase and amplitude between each linearly polarized light. In this paper, we analyzed the effect of phase and amplitude apodization with the fundamental multiple beam interference theory, and we compared resultant diffracted patterns on the image plane for the Si-disk first surface media structure and cover-layer incident media structure.

  • PDF

Wavefront Aberration Measurement with Shack-Hartmann Sensor and Point Source (Shack-Hartmann 파면분석기와 점광원을 이용한 광학부품의 수차 측정)

  • Lee, Jin-Seok;Kim, Hak-Young;Park, Yong-Pil;Park, No-Cheol;Hahn, Jae-Won
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.160-161
    • /
    • 2005
  • Using a Shack-Hartmann sensor, we construct an optical testing system measuring the wavefront error of small optical components. The systematic error of the sensor is compensated with a reference plane-wave system that produces almost perfect plane waves. Several types of lenses are tested using a point source that generates spherical waves emitted from a pinhole. The results of the optical testing obtained with the Shack- Hartman sensor are compared with those measured with Zygo interferometer.

  • PDF

Design of the Finite Schematic Eye with the Crystalline Lens with GRIN Index (실안의 수정체 굴절률 분포를 갖는 정밀모형안 설계)

  • Kim, Bong-Hwan
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.167-170
    • /
    • 2007
  • In this study, clinical data for emmetopia in young Koreans was taken in order to design the finite schematic eye, which had optical properties of real eyes including spherical aberration, astigmatism, field curvature and distortion. Furthermore, the crystalline lens with GRIN medium was optically analyzed, and the finite schematic eye with the GRIN crystalline lens was designed.

Amplitude Filter와 Phase Filter가 결합된 광학계의 결상특성

  • 박성종;이종진;정창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 1993
  • We chose Bessel beamu[$J_o(ar)}$)l in order to investigate image forming property of the optical system with combined filter of amplitude and phase(CFAP). This paper investigated numerically the influence of number of nodes of these beams on the PSF, encircled energy(E), transmission ratio(TR), gain((;) for an aberrated(1aberration-free) optical system. These results showed that the property of PSF differ considerably from the one of the existing amplitude filter and that Bessel beam has super compensating effect for an optical system with spherical aberration. Particularly, the Bessel beam has less the size of central spot than the radius of Airy disk, this result can therefore be applied to the fabrication of semiconductor device.

  • PDF

The Effect of Myopic Degree on the Change of Higher-order Aberrations Induced by Aging (근시도가 나이에 따라 유발되는 고위수차의 변화에 미치는 영향)

  • Ryu, Nam-Yul;Park, Kyoung-Hee;Kim, So-Ra;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.353-362
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the change of higher-order aberrations induced by aging and the effect of myopic degree on the correlation between age and higher-order aberrations. Methods: The higher-order aberrations in 931 eyes aged from 20 to 60 were measured by using a LADARWave device employing Hartmann-Shack system to analyze the effect of myopic degree measured by manifest refraction test on higher-order aberrations. Results: Coma and vertical coma aberrations were significantly decreased by the increase of myopic degree while vertical astigmatic aberration was significantly increased. The correlations of age and coma, vertical coma, spherical, vertical trefoil, horizontal trefoil, vertical astigmatic, horizontal astigmatic and vertical tetrafoil aberrations depended on the myopic degree, except for horizontal coma and horizontal tetrafoil aberrations. Conclusions: It is suggested to consider the myopic degree for the refractive correction including the laser surgery based on the present result that higher-order aberrations are affected by the myopic degree.

Glass selection Condition for Spherically Corrected Achromatic Doublet Lens (구면 및 색수차 보정 접합 렌즈의 광학유리 선정조건)

  • 이계훈;김민정;김재순;이재형
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.270-271
    • /
    • 2003
  • lens를 통과하는 두 광선(paraxial ray, marginal ray)이 lens의 축이나 focal plane과 만나는 지점이 서로 일치하지 않을 때, 두 개의 서로 다른 교차점 사이의 거리나 높이를 종, 횡 구면수차 (Lateral, Longitudinal Spherical aberration)이라 한다. 수차의 크기는 lens의 굽어짐 (bending)형태에 따라 달라지는데 3차 근사 lens 공식으로 유도한 식은 다음과 같으며, 그 결과의 그래프는 그림.1 과 같다. (중략)

  • PDF

Atomically sculptured heart in oxide film using convergent electron beam

  • Gwangyeob Lee;Seung-Hyub Baek;Hye Jung Chang
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.1.1-1.2
    • /
    • 2021
  • We demonstrate a fabrication of an atomically controlled single-crystal heart-shaped nanostructure using a convergent electron beam in a scanning transmission electron microscope. The delicately controlled e-beam enable epitaxial crystallization of perovskite oxide LaAlO3 grown out of the relative conductive interface (i.e. 2 dimensional electron gas) between amorphous LaAlO3/crystalline SrTiO3.

On-Machine Measurement of an Optical Surface by Hartmann Test (하트만 방법에 의한 광학면의 기상측정)

  • 김용관;오창진;이응석;김옥현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.474-480
    • /
    • 2002
  • Aspheric optical lenses and mirrors are widely used in recent. It is more difficult to manufacture and measure the aspherical optics compared to conventional spherical ones. The interferometric optical test is common for the measurement of spherical optical surface. But the application of the interferometry to the measurement of aspheric surface is difficult because it needs a precise null corrector and very careful environmental conditions such as keeping constant temperature, humidity, atmospheric pressure and vibrations. To enhance productivity of optics manufacturing on-machine measurement and correction has been developed in this study. For practical applications, robustness of the measurement method to environments is more important. For the purpose an optical OMM(On-Machine Measurement) system has been developed using Shack-Hartmann test which has robustness to the environment. The wavefront has been reconstructed from the measured data using the primary aberration polynomial function by least square fitting. The measured result of the developed only system gives the maximum deviation only in 200 nm from the result measured by a commercial Fizeau interferometer Wyko 6000.

  • PDF