• Title/Summary/Keyword: Sphere

Search Result 2,234, Processing Time 0.025 seconds

An Extendable Fixed-Complexity Sphere Decoder for Downlink Multi-User MIMO Communication System (하향링크 다중 사용자 MIMO 통신 시스템을 위한 확장형 고정복잡도 스피어 복호기)

  • Koo, Jihun;Kim, Yongsuk;Kim, Jaeseok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.4
    • /
    • pp.180-187
    • /
    • 2014
  • In this paper, a extension of a fixed-complexity sphere decoder (FSD) to perform interference signal detection and cancelling is proposed for downlink multiuser multiple input-multiple output (MIMO) communication system. It is based on the application of channel matrix expansion on generalized sphere decoder (GSD), and modification of the channel matrix ordering scheme to a FSD algorithm for interference detection. A Monte Carlo simulation shows that the proposed algorithm improves the receiver performance by 3 dB as compared to maximum likelihood detection without interference cancelling at 10% packet error rate in configuration of 702 Mbit/s datarate for four users respectively on IEEE802.11ac.

Stress and Electric Potential Fields in Piezoelectric Smart Spheres

  • Ghorbanpour, A.;Golabi, S.;Saadatfar, M.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.11
    • /
    • pp.1920-1933
    • /
    • 2006
  • Piezoelectric materials produce an electric field by deformation, and deform when subjected to an electric field. The coupling nature of piezoelectric materials has acquired wide applications in electric-mechanical and electric devices, including electric-mechanical actuators, sensors and structures. In this paper, a hollow sphere composed of a radially polarized spherically anisotropic piezoelectric material, e.g., PZT_5 or (Pb) (CoW) $TiO_3$ under internal or external uniform pressure and a constant potential difference between its inner and outer surfaces or combination of these loadings has been studied. Electrodes attached to the inner and outer surfaces of the sphere induce the potential difference. The governing equilibrium equations in radially polarized form are shown to reduce to a coupled system of second-order ordinary differential equations for the radial displacement and electric potential field. These differential equations are solved analytically for seven different sets of boundary conditions. The stress and the electric potential distributions in the sphere are discussed in detail for two piezoceramics, namely PZT _5 and (Pb) (CoW) $TiO_3$. It is shown that the hoop stresses in hollow sphere composed of these materials can be made virtually uniform across the thickness of the sphere by applying an appropriate set of boundary conditions.

Increased SOX2 expression in three-dimensional sphere culture of dental pulp stem cells

  • Seo, Eun Jin;Jang, Il Ho
    • International Journal of Oral Biology
    • /
    • v.45 no.4
    • /
    • pp.197-203
    • /
    • 2020
  • Mesenchymal stem cells in the dental pulp exhibit a tendency for differentiation into various dental lineages and hold great potential as a major conduit for regenerative treatment in dentistry. Although they can be readily isolated from teeth, the exact characteristics of these stem cells have not been fully understood so far. When compared to two-dimensional (2D) cultures, three-dimensional (3D) cultures have the advantage of enriching the stem cell population. Hence, 3D-organoid culture and 3D-sphere culture were applied to dental pulp cells in the current study. Although the establishment of the organoid culture proved unsuccessful, the 3D-sphere culture readily initiated the stable generation of cell aggregates, which continued to grow and could be passaged to the second round. Interestingly, a significant increase in SOX2 expression was detected in the 3D-spheroid culture compared to the 2D culture. These results indicate the enrichment of the stemness-high population in the 3D-sphere culture. Thus, 3D-sphere culture may act as a link between the conventional and 3D-organoid cultures and aid in understanding the characteristics of dental pulp stem cells.

Sparkover Voltage Estimation of Standard Sphere Gaps for Negative Polarity by Calculation of Ionization Index

  • Nishikori, Yasuo;Kojima, Soji;Kouno, Teruya
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.2
    • /
    • pp.45-50
    • /
    • 2004
  • The field utilization factor (equation omitted) (the mean electric field / the maximum electric field) of standard sphere gaps was calculated by the charge simulation method, taking into account the ground plane and shanks. n changes mainly with g/r and slightly with 1$_1$, 1$_2$ and 1, where D=2r is the sphere diameter, g is the gap length, 1$_1$ and 1$_2$, respectively, are the lengths of the upper and lower shank, and t is the shank diameter. Generally, (equation omitted) increases as 1$_1$,1$_2$ and t each becomes larger. IEC standard 60052(2002) limits t$\leq$0.2D 1$_1$$\geq$1D and prescribes A=1$_2$+D+g where A is the height of the spark point on the upper sphere. Therefore, (equation omitted) is the largest when A=9D and the smallest when A=3D. The simple equation of a straight line, (equation omitted)=1- (g/3r), can generally be used as a representative value of (equation omitted) for a wide variety of sphere diameters that are permitted by the IEC standard. The maximum electric field E$_{m}$ at sparkover of standard air gaps has also been calculated by the relation E$_{m}$=V/(equation omitted)g). E$_{m}$ describes a U-curve for g/r, up to the sphere diameter of 1 m. Moreover, for 1.5-m and 2-m diameters and especially .for negative polarity, sparkover voltages have been calculated by integration of the ionization index.index.

Influence of the Combustion Flames on the Flashover Characteristics of the Sphere-Sphere Air Gap (구-구갭의 섬락 특성에 미치는 연소화염의 영향)

  • Kim, In-Sik;Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.44-51
    • /
    • 2005
  • In this paper, reduction characteristics of the AC and DC flashover voltage in the horizontal air gap of sphere-sphere electrode system were investigated when the combustion flame was present near the high voltage electrode. The voltage and current waveforms were measured, when the flashover is occurred, in order to examine the flashover polarity by flame. The reduction characteristics of AC flashover voltage were discussed with the thermal ionization process, the relative air density and the deflection phenomena in the shape of flames that caused by the coulomb's force. As the results of an experimental investigation, It was found that the reduction of flashover voltages in sphere-sphere system, in comparison with the no flame case, are $79.9[\%]$ for k=0, $82.9[\%]$ for k=0.5, $87.5[\%]$ for k=1.0, $85.0[\%]$ for h=0[cm], $40.8[\%]$ for h=5[cm] and $28.2[\%]$ for h=9[cm] when ac voltage is applied. The influence for thermal ionization process of the combustion flame in small scale no particular change is recognized.

Complexity Limited Sphere Decoder and Its SER Performance Analysis (스피어 디코더에서 최대 복잡도 감소 기법 및 SER 성능 분석)

  • Jeon, Eun-Sung;Yang, Jang-Hoon;Kim, Bong-Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.6A
    • /
    • pp.577-582
    • /
    • 2008
  • In this paper, we present a scheme to overcome the worst case complexity of the sphere decoder. If the number of visited nodes reaches the threshold, the detected symbol vector is determined between two candidate symbol vectors. One candidate symbol vector is obtained from the demodulated output of ZF receiver which is initial stage of the sphere decoder. The other candidate symbol vector consists of two sub-symbol vectors. The first sub-symbol vector consists of lately visited nodes running from the most upper layer. The second one contains corresponding demodulated outputs of ZF receiver. Between these two candidate symbol vectors, the one with smaller euclidean distance to the received symbol vector is chosen as detected symbol vector. In addition, we show the upper bound of symbol error rate performance for the sphere decoder using the proposed scheme. In the simulation, the proposed scheme shows the significant reduction of the worst case complexity while having negligible SER performance degradation.

Association between mandibular occlusal morphology and occlusal curvature (교합면의 해부학적 형태와 교합만곡의 연관성에 대한 연구)

  • Nam, Shin-Eun;Lee, Heekyung
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.217-224
    • /
    • 2016
  • Purpose: This study aimed to generate 3-D occlusal curvatures and evaluate the relationship between the occlusal curvatures and mandibular occlusal morphology factors. Methods: Mandibular dental casts from 25 young adult Korean were scanned as a virtual dental models with a 3-D scanner(Scanner S600, Zirkonzahn, Italy). The curve of Spee, curve of Wilson, and Monson's sphere were generated by fitting a circle/sphere to the cusp tips using a least-squares method. The mandibular mesiodistal cusp inclination, buccolingual cusp inclination, and tooth wear parameters were measured on the prepared virtual models using RapidForm2004(INUS technology INC, Seoul, Korea). Wilcoxon signed-rank test was performed to test side difference, and Spearman's rank correlation coefficients were investigated to verify the correlation between occlusal curvatures and correlated factors (a=0.05). Results: The mean radii of curve of Spee were $83.09{\pm}33.94$ in the left side and $79.00{\pm}28.12mm$ in the right side. The mean radii of curve of Wilson were $66.82{\pm}15.87mm$ in the mesial side and $47.87{\pm}9.40mm$ in the distal side with significantly difference between mesiodistal sides(p<0.001). The mean radius of Monson's sphere was $121.85{\pm}47.11mm$. Most of the cusp inclination parameters showed negative correlation for the radius of Monson' sphere(p<0.05). Especially, the buccolingual cusp inclinations in mesial side of molar showed high correlation coefficients among the factors(p<0.05). Conclusion: The radius of Monson's sphere was greater than the classical 4-inch values, and the buccolingual cusp inclinations in mesial side of molar can be considered as one of the main factors correlating with the radius of Monson's sphere.

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.