• 제목/요약/키워드: Speed Variable

검색결과 2,059건 처리시간 0.033초

Alleviating the Tower Mechanical Load of Multi-MW Wind Turbines with LQR Control

  • Nam, Yoonsu;Kien, Pham Trung;La, Yo-Han
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1024-1031
    • /
    • 2013
  • This paper addresses linear quadratic regulation (LQR) for variable speed variable pitch wind turbines. Because of the inherent nonlinearity of wind turbines, a set of operating conditions is identified and then a LQR controller is designed for each of the operating points. The feedback controller gains are then interpolated linearly to get a control law for the entire operating region. In addition, the aerodynamic torque and effective wind speed are estimated online to get the gain-scheduling variable for implementing the controller. The potential of this method is verified through simulation with the help of MATLAB/Simulink and GH Bladed. The performance and mechanical load when using LQR are also compared with those obtained when using a PI controller.

Study on seismic performance of exterior reinforced concrete beam-column joint under variable loading speeds or axial forces

  • Guoxi Fan;Wantong Xiang;Debin Wang;Zichen Dou;Xiaocheng Tang
    • Earthquakes and Structures
    • /
    • 제26권1호
    • /
    • pp.31-48
    • /
    • 2024
  • In order to get a better understanding of seismic performance of exterior beam-column joint, reciprocating loading tests with variable loading speeds or axial forces were carried out. The main findings indicate that only few cracks exist on the surface of the joint core area, while the plastic hinge region at the beam end is seriously damaged. The damage of the specimen is more serious with the increase of the upper limit of variable axial force. The deflection ductility coefficient of specimen decreases to various degrees after the upper limit of variable axial force increases. In addition, the higher the loading speed is, the lower the deflection ductility coefficient of the specimen is. The stiffness of the specimen decreases as the upper limit of variable axial force or the loading speed increase. Compared to the influence of variable axial force, the influence of the loading speed on the stiffness degradation of the specimen is more obvious. The cumulative energy dissipation and the equivalent viscous damping coefficient of specimen decrease with the increase of loading speed. The influence of variable axial force on the energy dissipation of specimen varies under different loading speeds. Based on the truss model, the biaxial stress criterion, the Rankine criterion, the Kent-Scott-Park model, the equivalent theorem of shearing stress, the softened strut-and-tie model, the controlled slip theory and the proposed equations, a calculation method for the shear capacity is proposed with satisfactory prediction results.

스윙펌프를 내장한 가변속 스크롤 압축기의 오일공급시스템에 관한 CFD 시뮬레이션 (CFD Simulation on the Oil Pumping System of a Variable Speed Scroll Compressor with a Swing Pump)

  • 조홍현;김용찬;유병길
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.50-58
    • /
    • 2003
  • An analytical study was carried out to investigate the performance of an oil pumping system of a variable speed compressor using a commercial CFD program. The simulations for the oil supplying system with the oil and air mixture were performed by varying compressor speed from 40 Hz to 90 Hz. Comparing the predicted with the measured data on the modified scroll compressor validated the simulation model. The predicted results were consistent with the test data with a maximum deviation of 12.8%. The oil flow rate significantly increased with a rise of compressor speed due to a higher oil flow rate from the swing pump and a greater centrifugal force on oil gallery.

입력측 고조파 저감을 고려한 새로운 직류전동기 속도제어 (A Study on the DC Motor Speed Control with Reduced Hamonics)

  • 유철로;이공희;이성룡;강석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.102-104
    • /
    • 1988
  • This paper is studied the new speed control system of the DC motor which can drive constant speed at variable load as well as reduce the homonics. System is used thyristor-Leonard circuit with 2-tap in order to reduce the homonics problems due to chopping dc input voltage in chopper system and semiconductor devices in thyristor-Leonard system. There is added to the PLL system to drive the constant speed in variable Load, which has controlled of variable speed in DC motor. Thereby, we have proved its through experiment.

  • PDF

가변속 열펌프의 냉매 유량제어에 의한 난방성능 변화에 관한 실험적 연구 (An Experimental Investigation on the Variation of Heating Performance Due to the Refrigerant Flow Control in a Variable-Speed Heat Pump)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.746-756
    • /
    • 2001
  • An experimental study was conducted to investigated the effect of refrigerant flow control on the performance of a variable-speed heat pump operating in both cooling and heating mode. For this purpose, cooling and heating capacity, EER and refrigerant mass flow rate corresponding to an electronic valve as well as a capillary tube were measured as functions of compressor speed, length of capillary tube (or valve opening of the electronic valve), refrigerant charge, and outdoor temperature. From the comparison of experimental results, it was found that the performance variation due to the electronic valve opening became significant as the operating conditions(outdoor temperature and compressor speed) deviated from the standard condition at which heating capacity and EER were rated for the indicated capillary tube.

  • PDF

발전소 통풍계통의 가변속 운전을 위한 최적 설계조건에 관한 연구 (Study on Optimum Design Condition for Variable Speed Control of Rated Speed Fans used in a Power Plant)

  • 조철환;양경현;정남근;김봉진
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.30-35
    • /
    • 2010
  • Recently, the large capacity draft fans in power plants had been changed to variable speed type to educe the power consumption. But the fan experienced the unexpected vibration at specific speed regions. In this study, the high vibration frequency of the fan was confirmed and the natural frequency of the rotor were measured and analyzed by FEM programs. It was analyzed that the vibration was caused by the resonance at the frequency, 30.7Hz. So, the rotor vibration characteristic was changed by adjusting the distance between the shaft bearings. It was conformed the high vibration was disappeared over the all operation speeds.

가변 링크전압에 의한 센서리스 PMSM의 저속운전 성능개선 (Improved Performance of Sensorless PMSM in Low Speed Range Using Variable Link Voltage)

  • 이동희;권영안
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권10호
    • /
    • pp.708-711
    • /
    • 2000
  • Sensorless PMSM is much studied for the industrial applications and home appliances because a mechanical sensor reduce reliability and increase cost. Most of sensorless algorithms are based on motor equations, and so the magnitude of phase voltage and current should be exactly obtained. However, the inverter output voltage applied to PMSM has relatively large error in the low speed range, and a relatively poor response is shown in the low speed range. This paper investigates the improved performance of sensorless PMSM in the low speed range. This paper proposes the error reduction of inverter output voltage which is realized through the variable link voltage. The proposed algorithm is verified through simulation and experiment.

  • PDF

Power Regulation of Variable Speed Wind Turbines using Pitch Control based on Disturbance Observer

  • Joo, Young-Jun;Back, Ju-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.273-280
    • /
    • 2012
  • Most variable speed wind turbines have pitch control mechanisms and one of their objectives is to protect turbines when the wind speed is too high. By adjusting pitch angles of wind turbine, the inlet power and the torque developed by the turbine are regulated. In this paper, the difference between the real wind speed and its rated value is regarded as a disturbance, and a component called disturbance observer (DOB) is added to the pre-designed control loop. The additional DOB based controller estimates the disturbance and generates a compensating signal to suppress the effect of disturbance on the system. As a result, the stability and the performance of the closed loop system guaranteed by an outer-loop controller (designed for a nominal system without taking into account of disturbances) are approximately recovered in the steady state. Simulation results are presented to verify the performance of the proposed control scheme.

직류배전용 가변속 디젤발전기 개발에 관한 연구 (A Study on the Development of a Variable Speed Diesel Generator for DC Distribution)

  • 박기도;김종수
    • 해양환경안전학회지
    • /
    • 제25권1호
    • /
    • pp.117-121
    • /
    • 2019
  • 본 연구에서는 국내외적으로 환경문제 및 에너지절감의 일환으로 직류배전시스템을 선박에 적용하려는 연구 및 실증이 활발히 수행되고 있으며, 발전기를 직류배전시스템에 적용하기 위해서는 가변속 엔진을 적용하여 저부하 영역에서 발전기의 엔진 회전수를 줄여 연료소모량을 절감할 수 있는 방안이 제시되고 있다. 본 논문에서는 기존의 디젤발전기를 이용하여 발전기 컨트롤러, 가버너, AVR을 이용하여 직류배전용 가변속발전기를 구성하였으며, 발전기의 시스템 구성 방법, 가변속 발전에 따른 전력품질 시험(전압 및 주파수 변동특성, 부하변동 특성)을 통해 가변속 발전기의 전력특성을 분석 하였다. 가변속 발전기의 전압(250 ~ 440 VAC) 및 주파수(34 ~ 60 Hz)는 정격의 60 ~ 100 %로 구성하였으며, 엔진은 1100 ~ 1800 rpm 범위에서 운전되도록 설정 하였다. 부하변동에 따라 발전기의 엔진속도를 변경시켜서 발전기 출력의 전압, 전류, 주파수가 전력량에 따라 안정적으로 변동되는 것을 확인하였다.

Advanced Control of a PWM Converter with a Variable-Speed Induction Generator

  • Ahmedt, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo;Tanaka, Toshihiko
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.97-108
    • /
    • 2007
  • This paper describes simple control structures for a vector controlled stand-alone induction generator (IG) for use under variable speeds. Different control principles, indirect vector control and deadbeat current control, are developed for a voltage source PWM converter and the three-phase variable speed squirrel-cage IG to regulate DC-link and generator voltages with a newly designed phase locked loop circuit. The required reactive power for the variable speed IG is supplied by means of a PWM converter and a capacitor bank to buildup the voltage of the IG without the need for a battery, to reduce the rating of the PWM converter while using only three sensors and to eliminate the harmonics generated by the PWM converter. These proposed schemes can be used efficiently for variable speed wind energy conversion systems. The measurements of the IG systems at various speeds and loads are given and show that these systems are capable of good AC and DC voltage regulation.